• 제목/요약/키워드: Normal stiffness

검색결과 404건 처리시간 0.026초

The Effect of Calf Stiffness on Gait, Foot Pressure and Balance in Adults

  • Lee, JeonHyeong;Chang, JongSung
    • The Journal of Korean Physical Therapy
    • /
    • 제31권6호
    • /
    • pp.346-350
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate the effects of calf tightness on gait, plantar pressure, and balance in adults. Methods: A total of 60 participants were divided into a normal group of 30 subjects with normal dorsiflexion angle (20-25 degrees) and an experimental group of 30 subjects with limited dorsiflexion angle (0-15 degrees) due to calf tightness. Gait ability and foot pressure of the subjects was measured with a treadmill, and the balance ability was measured by PROKIN system. Results: A significant difference in COP length, loading response, and single limb support was observed between groups. The COP length and single limb support ratio in the normal group was greater than in the experimental group, but the experimental group showed a higher ratio for loading response in the gait ratio. Conclusion: Our results indicated that calf tightness was negative effects on balance and gait ability, so assessment of the muscle tightness should be considered during exercise and treatment.

단실단면을 갖는 강박스 거더교의 다이아프램의 강성과 간격에 관한 설계 최적화 (Design Optimization on Diaphragm Stiffness and Spacing of Steel-Box Girder Bridges with a Single-Cell Section)

  • 임다수;박남회;한택희;강영종
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.133-144
    • /
    • 2003
  • Generally, diaphragms are installed in the box girder to prevent or decrease the distortion of tile cross section. In engineering practice, diaphragms are spaced in 5m intervals without reasonable basis. ANd the usual diaphragm type is solid-plate type. It is considered to be noneconomical design to the almost design engineers. In this paper, the parametric study was performed to present the design proposal about the diaphragm stiffness and spacing only in tire single cell box girder. For that, the distortional warping normal stress, bending normal stress and transverse bending normal stress were analyzed using finite element program 'SMB' for the accurate structural analysis.

  • PDF

개설된 직접전단시험기(CNS)를 이용한 보강재의 인발력 추정 (Estimation of Pull-out force by using modified Direct Shear Apparatus)

  • 유병선;이학무;장기태;한희수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 사면안정학술발표회
    • /
    • pp.145-154
    • /
    • 2003
  • When a nail pulled out in dense, granular soil, the soil in the vicinity of the nail tends to dilate, but its dilatancy results in a normal stress concentration at the soil/nail interface, thereby increasing the pull-out resistance of the inclusion. It is thought to be occurring within the resistance zone where the soil mass is at stationary state and the reinforcement are held in position by the soil, due to the friction or bond. In this paper, A series of direct shear and interface tests were conducted by using so called‘Constant Normal Stiffness Test Apparatus’which was modified and improved from the conventional direct shear box test rig. Unlikely the normal shear box test, this enables to simulate the different constraint effects of surrounding soil during shear under the conditions of constant stress and volume, constant normal stiffness. The aim of the research programme is to get better understanding of pull-out bond mechanism, thus to explore the possibility of evaluating the pull-out bond capacity of soil/reinforcement at the preliminary design stage from the laboratory test.

  • PDF

Effect of stud corrosion on stiffness in negative bending moment region of steel-concrete composite beams

  • Yulin Zhan;Wenfeng Huang;Shuoshuo Zhao;Junhu Shao;Dong Shen;Guoqiang Jin
    • Steel and Composite Structures
    • /
    • 제48권1호
    • /
    • pp.59-71
    • /
    • 2023
  • Corrosion of the headed studs shear connectors is an important factor in the reduction of the durability and mechanical properties of the steel-concrete composite structure. In order to study the effect of stud corrosion on the mechanical properties in the negative moment region of steel-concrete composite beams, the corrosion of stud was carried out by accelerating corrosion method with constant current. Static monotonic loading was adopted to evaluate the cracking load, interface slip, mid-span deflection, and ultimate bearing capacity of four composite beams with varying corrosion rates of headed studs. The effect of stud corrosion on the stiffness of the composite beam's hogging moment zone during normal service stage was thoroughly examined. The results indicate that the cracking load decreased by 50% as the corrosion rate of headed studs increase to 10%. Meanwhile, due to the increase of interface slip and mid-span deflection, the bending stiffness dropped significantly with the same load. In comparison to uncorroded specimens, the secant stiffness of specimens with 0.5 times ultimate load was reduced by 25.9%. However, corrosion of shear studs had no obvious effect on ultimate bending capacity. Based on the experimental results and the theory of steel-concrete interface slip, a method was developed to calculate the bending stiffness in the negative bending moment region of composite beams during normal service stage while taking corrosion of headed studs into account. The validity of the calculation method was demonstrated by data analysis.

유연도 영향계수법을 이용한 접촉결합부가 있는 복합구조물의 동적 해석 (Structural Dynamics Analysis of a Clamp Jointed Complex Ream by Using the Flexibility Influence Coefficient Method)

  • 조재혁;김현욱;최영휴
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.528-533
    • /
    • 1995
  • An analyical method is proposed to construct a clamp jointed structure as an equivalent stiffness matrix element in the finite element modal analysis of a complex beam structure. Static structural analysis was first made for the detail finite element model of the clamp joint. Utilizing the results of this analysis, the equivalent stiffness matrix element was buildup by using the flexibility influence coefficient method and Guyan condensation. The proposed method was applied to finite element modal analysis of a clamp jointed cantilever beam. And the finite element analysis results were compared to those experimental modal analysis. Comparison shows doog agreement each other Furthermore the effects of normal contact(or clamping) load on the equivalent stiffness matrix was also examined. The equivalent stiffness matrix showed little change in spite of the remakable increase in the contact load on the clamp joint.

  • PDF

Equivalent stiffness method for nonlinear analysis of stay cables

  • Xia, G.Y.;Cai, C.S.
    • Structural Engineering and Mechanics
    • /
    • 제39권5호
    • /
    • pp.661-667
    • /
    • 2011
  • In the famous equivalent elasticity modulus method proposed by Ernst for the geometrical nonlinear analysis of stay cables, the cable shape was assumed as a parabolic curve, and only a part of the gravity load normal to the chord was taken into account with the other part of gravity load parallel to the chord being ignored. Using the actual catenary curve and considering the entire gravity load of stay cables, the present study has derived the equivalent stiffness method to analyze the sag effect of stay cables in cable-stayed bridges. The derived equivalent stiffness can be degenerated into Ernst's equivalent elasticity modulus method with some approximations. Therefore, the Ernst's method is a special and approximate formulation of the present method. The derived equivalent stiffness provides a theoretical explanation for the famous Ernst's formula.

절리면에서의 전단거동 특성과 역학적 파라미터들 간의 상관성 (Relationship between shear behavior characteristics and mechanical parameters of fractures)

  • 이종욱;이찬구;황신일;장천중;최원학
    • 지질공학
    • /
    • 제3권1호
    • /
    • pp.1-20
    • /
    • 1993
  • 본 연구에서는 절리면에서의 전단거동 특성을 규명하기 위해 총 37개의 편마암종 코아 시편들을 대상으로 Portable Direct Shear Box를 이용하여 실내 직접전단시험을 수행하였다. 시편들에 가해진 최대 수직응력의 범위는 $5.60~25.67kg/\textrm{cm}^2$이었으며, 전단하중을 점진적으로 가중시키는 다단계 전단시험법에 준하여 실험하였다. 이러한 방법에 의한 실험결과들을 분석하여 절리면의 전단강도에 관한 경험식들을 제시하였으며, 전단거동에 영향을 미치는 역학적 파라미터들을 도출하여 상호 비교 분석하였다. 절리조도계수에 따른 전단강성의 변화는 수직응력이 증가함에 따라 시편의 절리조도계수가 클수록 전단강성의 값도 급증하는 경향을 보이며, 본 실험에 적용한 최대 수직응력 하에서 구한 평균 할선 전단강성은 약 $110.68kg/\textrm{cm}^3$였다. 또한 수직응력이 증가함에 따라 시편의 깅이와 전단강성 사이에는 크기효과(size effect)에 의한 반비례 관계를 나타내어, 동일한 절리조도계수를 지닌 시편일지라도 길이가 긴 시편의 경우에 전단강성이 감소함을 알 수 있었다.

  • PDF

The Association of Body Fat and Arterial Stiffness Using the Brachial-Ankle Pulse Wave Velocity

  • Kim, Gyu Lee;Hwang, Hye Rim;Kim, Yun Jin;Lee, Sang Yeoup;Lee, Jeong Gyu;Jeong, Dong Wook;Yi, Yu Hyeon;Tak, Young Jin;Lee, Seung Hun;Park, A Rum
    • 가정의학회지
    • /
    • 제39권6호
    • /
    • pp.347-354
    • /
    • 2018
  • Background: BMI alone may not serve as an index of obesity because it does not reflect body composition. The present study aimed to compare arterial stiffness as assessed by the brachial-ankle pulse wave velocity (ba-PWV) among groups defined by body fat percentage (pBF) and BMI. Methods: This cross-sectional study was based on 1,700 participants (1,044 men and 656 women) who completed a health screening examination at a national hospital between January 2011 and February 2016. Participants were divided into four groups according to BMI and pBF: normal fat and normal weight (NFNW); excessive fat and normal weight (EFNW); normal fat and obese (NFO); and excessive fat and obese (EFO). The ba-PWV and other cardiometabolic factors were compared among the four groups in men and women separately. Results: For both sexes, the NFNW group had a lower metabolic risk compared to that in the other groups (EFNW, NFO, and EFO). After adjusting for multiple variables, the NFO males had a significantly lower ba-PWV compared to those in the other groups, including NFNW males. The NFO group had significantly more skeletal muscle mass and muscle mass compared the other groups (P<0.05). Among women, the NFNW group had a significantly lower ba-PWV compared the other groups, even after adjusting for multiple variables. Conclusion: Lower pBF in obese men may be associated with improved cardiovascular risk.

거칠기와 수직응력에 따른 암석 절리면의 전단거동 (The Influence of Rock Joint Roughness and Normal Stress on Shear Behaviour)

  • 이명호;김종우;장광택
    • 터널과지하공간
    • /
    • 제17권3호
    • /
    • pp.186-196
    • /
    • 2007
  • 본 연구에서는 거칠기와 수직응력이 절리면의 전단거동에 미치는 영향을 검토하기 위하여 30개의 자연암반 절리 시료를 대상으로 실험을 실시하였다. 3차원 레이저 거칠기 측정장치를 이용하여 절리면의 거칠기 정보를 측정하였으며, 시료들의 거칠기에 따라 10개씩 세 가지 그룹으로 분류하였다. 다음으로 수직응력을 다섯 단계로 변화시켜가며 전단실험을 실시함으로써 최대전단강도, 잔류전단강도, 전단강성, 팽창특성 등을 조사하였다. 절리면의 거칠기가 증가함에 따라 최대전단강도는 증가하였으며, 거칠기가 최대전단강도에 미치는 영향은 수직응력이 작은 경우에 더욱 크게 나타났다. 또한 절리면의 거칠기가 증가할수록 잔류전단강도도 점차 증가하였다. 전단강성은 거칠기 및 수직응력이 커짐에 따라 증가하는 것으로 나타났으나, 팽창각은 수직응력이 증가할수록 감소하였고, 동일한 수직응력하에서는 절리면의 거칠기가 커질수록 증가하였다.

Interfacial properties of composite shotcrete containing sprayed waterproofing membrane

  • Park, Byungkwan;Lee, Chulho;Choi, Soon-Wook;Kang, Tae-Ho;Kim, Jintae;Choi, Myung-Sik;Jeon, Seokwon;Chang, Soo-Ho
    • Geomechanics and Engineering
    • /
    • 제16권4호
    • /
    • pp.385-397
    • /
    • 2018
  • This study evaluates the interfacial properties of composite specimens consisting of shotcrete and sprayed waterproofing membrane. Two different membrane prototypes were first produced and tested for their waterproofing ability. Then composite specimens were prepared and their interfacial properties assessed in direct shear and uniaxial compression tests. The direct shear test showed the peak shear strength and shear stiffness of the composites' interface decreased as the membrane layer became thicker. The shear stiffness, a key input parameter for numerical analysis, was estimated to be 0.32-1.74 GPa/m. Shear stress transfer at the interface between the shotcrete and membrane clearly emerged when measuring peak shear strengths (1-3 MPa) under given normal stress conditions of 0.3-1.5 MPa. The failure mechanism was predominantly shear failure at the interface in most composite specimens, and shear failure in the membranes. The uniaxial compression test yielded normal stiffness values for the composite specimens of 5-24 GPa/m. The composite specimens appeared to fail by the compressive force forming transverse tension cracks, mainly around the shotcrete surface perpendicular to the membrane layer. Even though the composite specimens had strength and stiffness values sufficient for shear stress transfer at the interfaces of the two shotcrete layers and the membrane, the sprayed waterproofing membrane should be as thin as possible whilst ensuring waterproofing so as to obtain higher strength and stiffness at the interface.