• Title/Summary/Keyword: Normal operation

Search Result 2,149, Processing Time 0.031 seconds

The Accelerated Life Test of 2.5 Inch Hard Disk In The Environment of PC using (PC 사용 환경의 2.5 인치 하드디스크의 가속 수명 시험)

  • Cho, Euy-Hyun;Park, Jeong-Kyu;Seo, Hui-Don
    • Journal of Digital Contents Society
    • /
    • v.15 no.1
    • /
    • pp.19-27
    • /
    • 2014
  • In order to estimate the life of 2,5 inch HDD which is adopted by PC environment, make the test plan which reflect the failure mode of market, make the test model of accelerated life test which reflect the stress of temperature. after an analysis of the environment of PC using, test procedure was decided that operation was write 50 % and read 50 %, and then access method was sequential 50 % and random 50%. The acceleration life test was executed on condition that temperature was $50^{\circ}C$ and $60^{\circ}C$, performance was 95 % in max performance, test time was 1000 hours. by the test of goodness of fit of anderson-darling of the failure data during test, it was confirmed that the distribution of failure fellow weibull. test for shape and scale was equal, and shape parameter was 0.7177, characteristic life was 429434 hours at normal user condition($30^{\circ}C$) by the analysis of weibull-arrhenius modeling. It made no difference about the statistics when equality test was executed. The activation energy was 0.2775eV. In analyzing between the failure samples of acceleration test and the samples of market return even though there is detail difference about the share of failure mode, the rank of share was almost same. This study suggest the test procedure of acceleration test of 2.5 inch HDD in PC using environment, and help the life estimation at manufacture and user.

A Study of Facial Deformity in the Patient with Bilateral Cleft Lip before the Primary Cheiolplasty (양측성 구순열 환자의 안모 변형에 대한 연구)

  • Yoon Bo-Keun;Soh Byung-Soo;Baik Jin-Ah;Shin Hyo-Keun
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.4 no.2
    • /
    • pp.51-68
    • /
    • 2001
  • Midfacial hypoplasia in patients with clefts of the lip and palate is considered to be the result of congenital dysmorphogenesis. And cleft lip and palate developes facial deformity, jaw abnormality, speech problem, which is most frequent hereditary deformity in maxillofacial region. So cleft lip and palate is characterized by midface deformity which shaws maxillary anterior nasal septal deviation and deformity. Our study describes congenital correlates of midfacial hypoplasia by examining the displacement of a normal complement of parts, a triangular tissue deficiency low on the lip border on the columellar side, and a linear deficiency and displacement in the line of the bilateral cleft lip. 15 patients with bilateral cleft lip and palate were taken impression before operation, but the patient who had other abnormalities and complications were excluded. Average age is 3.4 months and they were classified into both complete, both incomplete and complete & incomplete group. The obtained results were as follows 1. There were no differences on intercanthal width and canthal width between each of the groups. 2. Both complete group had longer lateral ala length than both incomplete group, but there were no differences between both complete group and complete side of com. & incom. group and both incomplete group and incomplete side of com. & incom. group. 3. Columella length was greater in both incomplete group than in both complete group, but there was no difference between both complete group and complete side of com. & incom. group and both incomplete group and incomplete side of com. & incom. group. 4. Both complete group had longer ala width & ala base width than both incomplete group had. But there were no differences between both complete group and complete side of com. & incom. group and both incomplete group and incomplete side of com. & incom. group. 5. There were no differences between each of the groups on upper lip length, but nose/mouth width ratio was greater in both complete group than in both incomplete group. 6. Pronasale(pm), subnasle(sn), la~rale superioris(ls), stomion(sto) points were located around the central vertical line of face but deviated to incomplete side in com. & incom. group. 7. Nasal tip protrusion was greater in both incomplete group and com. & incom. group than both complete group, but there was no difference between both incomplete group and com. & incom. group.

  • PDF

A Case of Primary Choriocarcinoma of the Lung (원발성 폐 융모막암종 1예)

  • Cho, Young-Jae;Lee, Sei Won;Lee, Sang Min;Yim, Jae-Joon;Yoo, Chul-Gyu;Han, Sung Koo;Shim, Young-Soo;Kim, Young Whan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.6
    • /
    • pp.578-584
    • /
    • 2006
  • A primary choriocarcinoma of the lung is extremely rare, and difficult to distinguish from a metastatic choriocarcinoma considering that the lung is also one of the most frequent sites of metastasis. We report a 28-year-old woman patient who was initially misdiagnosed with an ectopic pregnancy and was operated on under the impression of an unidentified malignancy of the lung, which was finally proven to be a choriocarcinoma of the lung. A pelvic examination by a gynecologist, pelvic magnetic resonance imaging and whole body fluorodeoxyglucose positron emission tomography-computed tomography was performed in order to rule out a metastatic choriocarcinoma of the lung. After a curative operation, her serum ${\beta}$-human chorionic gonadotropin (HCG) level, which was highly elevated in the initial evaluation, had decreased dramatically to the normal range. She is currently being followed up regularly without any evidence of recurrence or elevation of her ${\beta}$-HCG level.

Development of FURA Code and Application for Load Follow Operation (FURA 코드 개발과 부하 추종 운전에 대한 적용)

  • Park, Young-Seob;Lee, Byong-Whi
    • Nuclear Engineering and Technology
    • /
    • v.20 no.2
    • /
    • pp.88-104
    • /
    • 1988
  • The FUel Rod Analysis(FURA) code is developed using two-dimensional finite element methods for axisymmetric and plane stress analysis of fuel rod. It predicts the thermal and mechanical behavior of fuel rod during normal and load follow operations. To evaluate the exact temperature distribution and the inner gas pressure, the radial deformation of pellet and clad, the fission gas release are considered over the full-length of fuel rod. The thermal element equation is derived using Galerkin's techniques. The displacement element equation is derived using the principle of virtual works. The mechanical analysis can accommodate various components of strain: elastic, plastic, creep and thermal strain as well as strain due to swelling, relocation and densification. The 4-node quadratic isoparametric elements are adopted, and the geometric model is confined to a half-pellet-height region with the assumption that pellet-pellet interaction is symmetrical. The pellet cracking and crack healing, pellet-cladding interaction are modelled. The Newton-Raphson iteration with an implicit algorithm is applied to perform the analysis of non-linear material behavior accurately and stably. The pellet and cladding model has been compared with both analytical solutions and experimental results. The observed and predicted results are in good agreement. The general behavior of fuel rod is calculated by axisymmetric system and the cladding behavior against radial crack is used by plane stress system. The sensitivity of strain aging of PWR fuel cladding tube due to load following is evaluated in terms of linear power, load cycle frequency and amplitude.

  • PDF

Clinical and Bacteriological Observation of 128 Cases of Chronic Otitis Media (중이수술 128례에 대한 임상적 세균학적 고찰)

  • 김광수;김정중;이계실;차인숙
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1983.05a
    • /
    • pp.19.2-19
    • /
    • 1983
  • A Clinical and bacteriologcal observation was performed 128 cases of chronic otitis media who had taken middle ear surgery at Dept. of otolaryngology of St. Benedict Hospital during the period of Feb. 1981 to Feb. 1983. The following results were obtained. 1) Among total 128 cases, male were 60 cases (46.9%) and female were 68 cases (53.1 %) and age distribution showed 48 cases (37.5 %) in 3rd decade, 37 cases (28.9 %) in 2nd decade and 27 cases (21.1 %) in 4th decade. 2) Site distribution were 71 cases (55.5%) in right, 57 cases (44.5 %) in left. 3) Degree of preoperative hearing loss were 64 cases (50%) in moderate, 32 cases (25% ) in mild, 27 cases (21.1 %) in severe and 5 cases (3.9%) were normal. 4) Central perforation were observed in 65 cases (50.8 %), total perforation in 44 cases (34.4 %), attic perforation in 12 cases (9.4 %) and marginal perforation in 7 cases (5.4 %). 5) Pathologic changes of middle ear and mastoid antrum showed granulation in 81 cases (63.3 %), cholesteatoma in 47 cases (36.7%). 6) The route of approach were 123 cases (96.1%) in postauricular, 3 cases (2.3%) in transmeatal and 2 cases (1.6 %) in endaural. 7) Type of operation were 53 cases (41.4 %) in intact canal wall tympanoplasty with mastoidectomy, 42 cases (32.8 %) in tympanoplasty without mastoidectomy, 23 cases (18%) in modified radical mastoidectomy and 10 cases (7.8%) in radical mastoidectomy. 8) Type of anesthesia were 95 cases (74.2 %) by local anesthesia, 33 cases (25.8 %) were by general anesthesia. 9) Among 93 specimens of culture, proteus (31.2%), staphylococcus (28.7%), pseudomonas (23.7 %), streptococcus (7.5 %) and etc. (8.7%) in order of frequency.

  • PDF

Correlationship Between Degree of Displacement and Range of Motion of the Subtalar joint after Calcaneal fracture (종골 골절 후 거골하 관절면의 전위 정도와 운동 범위의 상관 관계)

  • Park, In-Heon;Lee, Kee-Byung;Song, Kyung-Won;Lee, Jin-Young;Lee, Eung-Joo;Park, Rae-Seong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.2 no.1
    • /
    • pp.19-29
    • /
    • 1998
  • The characteristics of the patients after the calcaneal fracture that were associated with an unsatisfactory outcome were subtalar incongruity, decreased Bohler angle ratio of the fractured to the normal side, an age of more than fifty years, work involving strenuous labor, and increased time missed from work due to the injury. The purpose of this study was to examine the reliability of measurements of the range of motion of the subtalar joint. To determine reliability, evaluates of the correlatioinship between the degree of the displacement of the subtalar joint and Circle draw test after the calcaneal fracture. Fifty patients who had had fifty five calcaneal fractures were managed with open reduction and internal fixation. The results were reviewed retrospectively, between 4months and three years after the operation, with use of an evaluation system for the subtalar joint and with plain radiographs. At follow up evaluation, the result was assessed on the basis of restoration of anatomy and function of the subtalar joint. We evaluated the subtalar joint with plain films that consist of anteroposterior projection, lateral projection, calcaneal axial view, and Broden's view, and the measurements of the displacement of the subtalar joint surface after the calcaneal fracture. And we evaluated the range of motion of the subtalar joint with Circle draw test for physical evaluation. Circle draw test was evaluated and demonstrated the motion of flexion-supination-adduction and extension-pronation-abduction of the subtalar joint. And there are correlationship between the degree of the displacement and range of motion of the subtalar joint after the calcaneal fracture. The report critically reviews methords used to measure Circle draw test for physical examination of the follow up after the calcaneal fracture.

  • PDF

A Frame Stress and Integration Monitoring System based on Continuous Track Type for Multipurpose Application of Electric Wheelchair (전동휠체어의 다목적 활용을 위한 무한궤도형 기반의 프레임 응력 및 통합 모니터링 시스템)

  • Jo, Kyeong-Ho;Jung, Se-Hoon;Park, Jae-Sung;Yoo, Seung-Hyun;Sim, Chun-Bo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.5
    • /
    • pp.1135-1144
    • /
    • 2018
  • An electric wheelchair used to be utilized as a piece of equipment for the disabled and the elderly in the past, but the recent changes to its functions and forms have made it available across various fields and purposes. In this paper, we propose a continuous track type of electric wheelchair prototype to be used in various fields and environments and a monitoring system to control it. A frame stress design was applied to improve its stability during driving compared with the previous wheelchairs. In addition, we provide a convenience for free and easy operation of them using the App. based on android. A monitoring system based on C# was also added to control a large number of electric wheelchairs. As a result of the implementation and performance evaluation, the von Mises stress value was measured 4.401% within the normal range through five times of stress interpretations, and its accuracy of communication for system manipulation was recorded about 98.75%, which means that it has been proven to be safer than the previous wheelchairs.

A Study on the Test Results and Wideband Observing of the Korean VLBI Network (KVN의 광대역 관측 시험 및 결과고찰)

  • Oh, Se-Jin;Oyama, Tomoaki;Yeom, Jae-Hwan;Nishikawa, Takashi;Roh, Duk-Gyoo;Kim, Seung-Rae;Lee, Eui-Gyeom;Je, Do-Heung;Byun, Do-Young;Lee, Seong-Mo;Chung, Hyun-Soo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.17 no.2
    • /
    • pp.83-92
    • /
    • 2016
  • In this paper, we introduce the results of the testing and observation systems for performance wideband expansion in the Korean VLBI Network(KVN). The KVN performs VLBI observations to 1024 Mbps data rate, and 8192 Mbps observing for four simultaneous observation is now evaluating for normal operation. The VLBI stations in several world countries developed their own wideband observing systems to observe the celestial objects with high precision and high resolution or are working with several countries. The KVN is planning to introduce a high-speed sampler, OCTAD, for sampling directly up to 2048 MHz bandwidth for RF signal of K/Q/W/D band in the frequency band without conversion. Therefore, as a preliminary study for the performance scalability of the KVN then through the close cooperation with National Astronomical Observatory of Japan (NAOJ), the OCTAD high-speed sampler and OCTADISK2 high-speed recorder were installed in the KVN Yonsei station, and verify the performance through a wideband.

Application of Modified Mupit for the Recurrent Vulva Cancer in Brachytherapy

  • Kim, Jong-Sik;Jung, Chun-Young;Oh, Dong-Gyoon;Song, Ki-Won;Park, Young-Hwan
    • 대한방사선치료학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.23-26
    • /
    • 2005
  • Introduction: To evaluate whether modified MUPIT applicator can effectively eradicate recurrent tumor in uterine cervix cancer and reduce rectal complication after complete radiation treatment. Methods and Materials: Modified MUPIT applicator basically consists of an acrylic cylinder with flexible brain applicator , an acrylic template with a predrilled array of holes that serve as guides for interstitial needles and interstitial needles. CT scan was performed to determine tumor volume and the position of interstitial needles. Modified MUPIT applicator was applied to patient in operation room and the accuracy for position of interstitial needles in tumor volume was confirmed by CTscan. Brachytherapy was delivered using modified MUPIT applicator and RALS (192-Ir HDR) after calculated computer planning by orthogonal film. The daily dose was 600cGy and the total dose was delivered 3000cGy in tumor volume by BID. Rectal dose was measured by TLD at 5 points so that evaluated the risk of rectal complication. Result: The application of modified MUPIT applicator improved dramatically dose distributions in tumor volume and follow-up of 3 month for this patient was clinically partial response without normal tissue complication, Rectal dose was measured 34.1cGy, 57.1cGy, 103.8cGy, 162.7cGy, 165.7cGy at each points, especially the rectal dose including previous EBRT and ICR was 34.1cGy, 57.1cGy Conclusion: Patients with locally recurrent tumor in uterine cervix cancer treated with modified MIUPIT applicator can expect reasonable rates of local control. The advantages of the system are the fixed geometry Provided by the template and cylinders, and improved dose distributions in irregular tumor volume without rectal complication

  • PDF

Technical Trends of Hydrogen Manufacture, Storage and Transportation System for Fuel Cell Vehicle (연료전지자동차용 수소제조와 저장·운반기술동향)

  • Kil, Sang-Cheol;Hwang, Young-Gil
    • Resources Recycling
    • /
    • v.25 no.1
    • /
    • pp.48-59
    • /
    • 2016
  • The earth has been warming due to $CO_2$ gas emissions from fossil fuel cars and a ship. So the hydrogen fuel cell vehicle(FCV) using hydrogen as a fossil fuel alternative energy is in the spotlight. Hyundai Motor Company of Korea and a car companies of the US, Japan, Germany is developing a FCV a competitive. Obtained hydrogen as a by-product of the coke plant, oil refineries, chemical plants of steel mill, coal is reacted with steam at high temperatures, methane gas, manufacture of high purity hydrogen Methane Steam Reforming and hydrogen detachable reforming method using the Pressure Swing Adsorption or Membrane Reforming technical or decomposition of water to produce electricity. Hydrogen is the electronic industry, metal and chemical industries, which are used as rocket fuel, etc. are used in factories, hospitals, home of the fuel Ene.Farm system or FCV. And a method of storing hydrogen is to store liquid hydrogen and a method for compressing normal hydrogen to the hydrogen container, by storing the latest hydride or Organic chemical hydride method is used to carry the hydrogen station. Korea is currently 13 hydrogen stations in place and in operation, plans to install a further 43 places.