• 제목/요약/키워드: Normal force

검색결과 1,322건 처리시간 0.031초

3축 그라인딩 로봇을 이용한 자동 경로 생성 및 능동 컴플라이언스 힘 제어 (Auto Path Generation and Active Compliance Force Control Using 3-axis Grinding Robot)

  • 추정훈;김수호;이상범;김정민
    • 제어로봇시스템학회논문지
    • /
    • 제12권11호
    • /
    • pp.1088-1094
    • /
    • 2006
  • In this paper, an auto path generation and an active compliance grinding control using 3-axis farce sensor are presented. These control algorithms enable the grinding robot to follow unknown path of various workpiece shape pattern. The robot is able to go grinding along unknown paths by position controller managing tangential direction angle and cutting speed, with only information about the start position and the end position. Magnitude and direction of normal force are calculated using force data that go through low pass filter. Moreover, normal and tangential directions are separated for force control and velocity control, respectively.

엔드밀 공정에서 공구 동력계를 이용한 절삭상태 감시 (Cutting Process Monitoring Using Tool Dynamometer in End-Milling Process)

  • 김홍겸;양호석;이건복
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 추계학술대회(한국공작기계학회)
    • /
    • pp.14-18
    • /
    • 2001
  • Rise in cutting force causes tool damage and worsens product quality resulting in machining accuracy deterioration. Especially, fragile material cutting brings about breakage of material and worsens product surface quality. In this study, we trace the locus of cutting force and examine the machined surface corresponding to the cutting force loci. and build up a monitoring system for deciding normal operation or not of cutting process.

  • PDF

영구자석 배열에 따른 PMLSM의 진동 및 효율 특성에 관한 연구 (A Study on the Vibration and Efficiency Characteristics of PMLSM According to Permanent Magnet Arrangement)

  • 이동엽;이승훈;장기봉;김규탁
    • 전기학회논문지
    • /
    • 제58권2호
    • /
    • pp.270-277
    • /
    • 2009
  • This paper deals with a vibration and efficiency characteristics of Permanent Magnet Linear Synchronous Motor according to the PM arrangement. The generated force such as the thrust, detent force, normal force and lateral force are compared with analysis values and experimental ones. Furthermore characteristics of vibration and efficiency are estimated by experiments.

Comparison analysis of psychological and biochemical indices of chronic life stress

  • Kim, Dongsoo;Park, Se-kwon;Chung, Yeon-Soo;Moon, Soo-Jong
    • 한국독성학회:학술대회논문집
    • /
    • 한국독성학회 2003년도 추계학술대회
    • /
    • pp.162-162
    • /
    • 2003
  • The psychological and biochemical stress responses of healthy men and women were measured under the normal situation. Experimental subjects, who were cadets of the Korea Air Force Academy, were selected by the random sampling. Quantitative scaling of the psychological stress was obtained by life stress test(Cheon et al, 2000) and Minnesota Multiphasic Personality Inventory(MMPI).(omitted)

  • PDF

하중판을 이용한 미끄러짐 측정기의 동력학적 특성 평가 (Evaluation of Dynamic Characteristics of Slipmeters with Force Platform)

  • 김정수
    • 한국안전학회지
    • /
    • 제27권5호
    • /
    • pp.1-8
    • /
    • 2012
  • The purpose of this study were to evaluate the dynamic characteristics of the portable slipmeters with respect to actual slipping and to compare their output with those of force platform. The selected slipmeters were commonly used devices for slipperiness measurement in situ floors. Their output quantity represented force (BOT-3000), loss of energy(British pendulum striker) and angle of inclination(English XL). The validity of these devices was studied with respect to actual slipping using a force platform. The precision of these devices was also evaluated with force platform. Based on dynamics of human subject behavior when slipping during normal walking, the all devices tested in this study showed poor performances: low built up ratio, low normal pressure, and long contact time prior to slip. Nevertheless, their results reasonably correlated with those calculated from the ground reaction forces generated by the operation of the selected slipmeters on the force platform although the absolute values of COF from these three devices could be quite different. Also the results showed good repeatability under the some test conditions.

One-dimensional modeling of flat sheet casting or rectangular Fiber spinning process and the effect of normal stresses

  • Kwon, Youngdon
    • Korea-Australia Rheology Journal
    • /
    • 제11권3호
    • /
    • pp.225-232
    • /
    • 1999
  • This study presents 1-dimensional simple model for sheet casting or rectangular fiber spinning process. In order to achieve this goal, we introduce the concept of force flux balance at the die exit, which assigns for the extensional flow outside the die the initial condition containing the information of shear flow history inside the die. With the Leonov constitutive equation that predicts non-vanishing second normal stress difference in shear flow, we are able to describe the anisotropic swelling behavior of the extrudate at least qualitatively. In other words, the negative value of the second normal stress difference causes thickness swelling much higher than width of extrudate. This result implies the importance of choosing the rheological model in the analysis of polymer processing operations, since the constitutive equation with the vanishing second normal stress difference is shown to exhibit the characteristic of isotropic swelling, that is, the thickness swell ratio always equal to the ratio in width direction.

  • PDF

Vibrational Assignment of S$_8$ from Normal Coordinatie Analysis

  • Chang, Man-Chai;Kim, Hyun-Yong;Jhon, Mu-Shik
    • Bulletin of the Korean Chemical Society
    • /
    • 제6권1호
    • /
    • pp.29-32
    • /
    • 1985
  • Normal modes of crystalline orthorhombic sulfur belonging to the space group $D_{2h}$-Fddd, have been evaluated by taking the lowest temperature phase in the solid. Normal modes are obtained by the valence force field with modified force constants and a quantitative description of the mode is adjusted by the potential energy distribution. Since the full crystal system of orthorhombic sulfur is so large, we intended to calculate the normal modes simply by constructing the imaginary box made by the infinite mass boundary. And the Raman experiment is done by using the more powerful Ar-Kr gas laser with lowering the temperature to ${\sim}10^{\circ}K$.

자기 체결 마찰 클러치의 전달 토크에 관한 연구 (A Study on the Transmitted Torque of Self Clamping Friction Clutch)

  • 왕지석;김종도;윤희종
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권8호
    • /
    • pp.1149-1156
    • /
    • 2008
  • The principle of self clamping friction clutch is presented in this paper and the transmitted torque capacity is also calculated. In order to enlarge the friction force, a part of rotating force of driving side is converted to normal force of friction materials by clamping arm. The increased normal force of friction materials assures the large friction force and the transmitted torque capacity of clutch becomes large. The self clamping friction clutch is adopted in the tube type air pressure clutch and the condition of stability is investigated. It is proven that the inclined angle of clamping arm and the friction factor of friction materials are the essential elements in stability and torque capacity of self clamping friction clutch. The transmitted torque capacity of self clamping friction clutch is compared with air pressure clutch. The normal force of friction lining is magnified by 1/(1-k) and the transmitted torque capacity is also magnified with same proportion comparing with air pressure clutch. The larger the friction factor of friction lining, the larger the magnification factor. The longer the clamping arm, the smaller the magnification factor. It must be also noted that the value of k=${\mu}Y/X$ is the criterion of stability. If the value of k=${\mu}Y/X$ is greater than or equal to 1, the self clamping friction clutch is unstable and it can not be used as clutch.

백서구치의 실험적 치아이동후 치수조직 변화에 관한 조직학적 연구 (A HISTOLOGIC STUDY OF PULPAL REACTION AFTER EXPERIMENTAL TOOTH MOVEMENT IN RATS)

  • 진근호;홍성준
    • 대한치과교정학회지
    • /
    • 제21권3호
    • /
    • pp.635-656
    • /
    • 1991
  • It was the aim of this investigation to evaluate some histologic aspect of rat pulp tissue after it had been compromised by an experimental orthodontic force. Experimental animals of thirty five Spraque-Dawley rats were employed. The first upper molars had been successively mesial moved (initial load 100 gr.) with a closed coil spring during 21 days. The experimental periods were set on immediate, 1 day, 1 week, 2 weeks, 3 weeks, 4 weeks following retention time. On each experimental period, the rats were killed and prepared for the light microscopy. After prepared with H/E stain and Gomori's one-step trichrome stain, the specimens were analyzed with evaluation criteria which were adopted in this study. The result may be summarized as follows; 1. The main pulp changes due to experimental orthodontic force included vacuolization of odontoblastic layer, circulation disturbance, root resorption, reduced pulp collagenous fiber density and mean cell count of pulp fibroblast in the immediate group. 2. The pulp tissue changes were revealed reversible because the relieved pulp tissues from experimental orthodontic force were recovered rapidly in each evaluation criteria during retention periods. 3. Compared with normal control group, pulp collagenous fiber density were decreased in immediated group (p < 0.01), but increased in each retention groups. These seem to suggest that the pulp tissues were aged after experimental orthodontic force conditions. 4. Compared with normal control group, mean cell counts of pulp fibroblasts were decreased in immediate group (p < 0.05), but increased continuous in each retention groups. These seem to indicate that the pulp tissues were highly regenerative after experimental orthodontic force conditions. 5. Compared with normal control group, root resorptions occurred in all immediate specimens (p < 0.01) and they were healed in each retention periods, but often observed in 4 weeks retention group. These seem to indicate that root resorptions were recovered slowly after experimental orthodontic force conditions.

  • PDF

폴리머 재료를 이용한 유연 수직/수평 힘 센서 어레이 개발 및 응용 (Development and Application of Polymer-based Flexible Force Sensor Array)

  • 황은수;윤영로;윤형로;신태민;김용준
    • 한국정밀공학회지
    • /
    • 제26권5호
    • /
    • pp.142-149
    • /
    • 2009
  • This paper proposes and demonstrates novel flexible contact force sensing devices for 3-dimensional force measurement. To realize the sensor, polyimide and polydimethylsiloxane are used as a substrate, which makes it flexible. Thin-film metal strain gauges, which are incorporated into the polymer, are used for measuring the three-dimensional contact forces. The force sensor characteristics are evaluated against normal and shear load. The fabricated force sensor can measure normal loads up to 4N. The sensor output signals are saturated against load over 4N. Shear loads can be detected by different voltage drops in strain gauges. The device has no fragile structures; therefore, it can be used as a ground reaction force sensor for balance control in humanoid robots. Four force sensors are assembled and placed in the four corners of the robot's sole. By increasing bump dimensions, the force sensor can measure load up to 20N. When loads are exerted on the sole, the ground reaction force can be measured by these four sensors. The measured forces can be used in the balance control of biped locomotion system.