• 제목/요약/키워드: Nonlinear Load Current

검색결과 288건 처리시간 0.037초

Single-phase Active Power Filter Based on Rotating Reference Frame Method for Harmonics Compensation

  • Kim, Jin-Sun;Kim, Young-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권1호
    • /
    • pp.94-100
    • /
    • 2008
  • This paper presents a new control method of single-phase active power filter (APF) for the compensation of harmonic current components in nonlinear loads. To facilitate the possibility of complex calculation for harmonic current detection of the single phase, a single-phase system that has two phases was constructed by including an imaginary second-phase giving time delay to the load current. The imaginary phase, which lagged the load current T/4 (Here T is the fundamental cycle) is used in the conventional method. But in this proposed method, the new signal as the second phase is delayed by the filter. Because this control method is applied to a single-phase system, an instantaneous calculation was developed by using the rotating reference frames synchronized to source-frequency rather than by applying instantaneous reactive power theory that uses the conventional fixed reference frames. The control scheme of single-phase APF for the current source with R-L loads is applied to a laboratory prototype to verify the proposed control method.

A Current Sharing Circuit for the Parallel Inverter

  • Lee, Chang-Seok;Kim, Si-Kyung
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.176-181
    • /
    • 1998
  • The parallel inverter is popularly used because of its fault-tolerance capability, high-current outputs at constant voltages and system modularity. The conventional parallel inverter usually employs active and reactive power control of frequency and voltage droop control. However, these approaches have the disadvantages that the response time of parallel inverter control is slow against load and system parameter variation to calculate active, reactive power, frequency and voltage. This paper describes a novel control scheme for power equalization in parallel-connected inverter. The proposed scheme has a fast power balance control response, a simplicity of implementation, and inherent peak current limiting capability since it employees an instantaneous current/voltage control with output voltage and current balance and output voltage regulation. A design procedure for the proposed parallel inverter controller is presented. Furthermore, the proposed control scheme is verified through the experiment in various cases such as the system parameter variation, the control parameter variation and the nonlinear load condition.

  • PDF

100kV급 비상발전기용 통합제어기 (Unified Controller for 100kVA Emergency Generator)

  • 정창용;조정구;백주원;이종주;김용주;유동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2801-2803
    • /
    • 1999
  • An unified controller for emergency generator is presented to control AVR and Governor and l00kVA power conditioner. This controller is operated to compensate current harmonics and asymmetries caused by nonlinear load and unbalance loads. The power conditioner shapes the source current sinusoidal in phase with source voltage and allows the generator to maximum power even to the single phase load. Also this power conditioner allows that three phase generator synchronizes with single phase main source and load sharing. An l00kVA generator system was built and the unified controller is realized with DSP(TMS320C32PCMA). Experimental results for many load conditions are presented to verify the performance of the unified controller.

  • PDF

A NEW INSTANTANEOUS VOLTAGE COMPENSATOR WITH FUNCTION OF ACTIVE POWER FILTERING

  • Lee, Seung-Yo;Lee, Jeong-Min;Lee, Sang-Yong;Mok, Hyung-Soo;Choe, Gyu-Ha
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.780-784
    • /
    • 1998
  • A novel active input unbalance voltage compensator with harmonic current compensating capability is proposed and the operating principle of the proposed system is presented in the 3-phase power system. The proposed system performs both the voltage regulation of the load and the compensation of the harmonic currents generated due to nonlinear load such as diode rectifier. The system to compensate unbalanced voltage and hramonic currents is composed of a 3-phase voltage source inverter, LC filter, series transformer and passive devices at the load side of the line. The compensating voltage to regulate the load voltage and to remove the harmonic current components is transmitted to the line by the series transformer. The validity of the line by the series transformer. The validity of the proposed system is proved by the results of computer simulation.

  • PDF

직접토크제어에 의한 리럭턴스 동기전동기의 고성능 제어시스템 (A High-Performance Control System of Reluctance Synchronous Motor with Direct Torque Control)

  • 김민회
    • 전기학회논문지P
    • /
    • 제51권2호
    • /
    • pp.68-76
    • /
    • 2002
  • This paper presents an implementation of high-dynamic performance control system of Reluctance Synchronous Motor (RSM) drives for an industrial servo system with direct torque control (DTC). The problems of DTC for high-dynamic performance and maximum efficiency RSM drives are the nonlinear variable flux and inductance due to a saturated stator linkage flux and nonlinear inductance curve with various load currents. The accurate estimation of the stator flux and torque are obtained using stator flux observer of which a saturated inductance Ld and Lq can be compensated by using the adapted neural network from measuring the modulus and angle of the stator current. To obtain fast torque response and maximum torque/current with varying load current, the reference command flux is ensured by imposing Ids=Iqs. This control strategy is proposed to fast response and optimal efficiency for RSM drive. In order to prove rightness of the suggested control algorithm, we have some actual experimental system using 6000 pulse/rev encoder at ${\pm}10$ and ${\pm}1500rpm$. The developed digitally high-performance control system are shown some good response characteristics of control results and high performance features using 1.0kW RSM of which has 2.57 Ld/Lq salient ratio.

Co3O4 첨가량 변화에 따른 ZnO Varistor의 전기적 특성 (Electrical Properties of ZnO Varistors with Variation of Co3O4)

  • 조현무;이성갑
    • 한국전기전자재료학회논문지
    • /
    • 제17권11호
    • /
    • pp.1186-1191
    • /
    • 2004
  • ZnO varistor ceramics which were fabricated with variation of added of 0.5~1.0 mol% Co$_3$O$_4$, were sintered at 1150 $^{\circ}C$. In the specimen added 0.7 mol% Co$_3$O$_4$, sintered density was 6.03 g/㎤ and electrical properties were superior to any other compositions. The nonlinear coefficient a and clamping voltage ratio were 83 and 1.35, respectively. But, endurance surge current in the specimen added 0.5 mol% Co$_3$O$_4$ was 7000 A/$\textrm{cm}^2$, and deviation of varistor voltage was Δ-3.23 %. As P.C.T and T.C.T environmental test were succeed in all specimens, and deviation of varistor voltage in the specimen added 0.6 mol% Co$_3$O$_4$ was Δ-0.81 %. All specimens showed good leakage current property on the High Temperature Continuous Load Test(HTCLT) for 1000 hr at 85 $^{\circ}C$ and variation rate of the varistor voltage below Δ-2.0 %.

회전좌표계를 이용한 단상능동전력필터의 제어이론 (A Control Algorithm of Single Phase Active Power Filter based on Rotating Reference Frame)

  • 김진선;김영석;신재화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1480-1482
    • /
    • 2005
  • The major causes of power quality deterioration are harmonic current through semiconductor switching device, due to use of nonlinear loads such as diodes rectifier or thyristor rectifiers. In response to this concerns, this paper presents a new control method of single-phase active power filter(APF) for the compensation of harmonic current components in nonlinear loads. In order to make the complex calculation to be possible, the single-phase system that has two phases was made by constructing a imaginary second-phase giving time delay to load currents. In the conventional method, a imaginary-phase lagged to the load current T/4(here T is the fundamental cycle) was made. But in this proposed method, the new signal, which has the delayed phase through the filter, using the phase-delay property of low-pass filter, was used as the second phase. As this control method is applied to the system of single phase, an instantaneous calculation was done rather by using the rotating reference frames that synchronizes with source-frequency than by applying instantaneous reactive power theory that uses the conventional fixed reference frames.

  • PDF

부하전류 추정기법에 의한 단상능동전력필터 제어 (A Single-Phase Active Power Filter Control with Load Current Estimation Method)

  • 곽상신;이무영;최연호;임성운;권우현
    • 전력전자학회논문지
    • /
    • 제5권4호
    • /
    • pp.335-342
    • /
    • 2000
  • 단상 능동전력필터에 있어서 비선형 부하전류를 직접 검출하지 않고 능통전력필터의 직류측 커패시터 전압을 이용해 추정하여 제어하는 방법을 제안한다. 이는 부하전류와 능동전택필터의 직류측 커패시터 전압을 봉사에 검출하는 기존의 방식에 비해 부하전류 검출단을 제거할 수 있음으로써 설치가 간편할 뿐만 아니라 가격을 낮출 수 있으면서도 동일한 성능의 능동전력필터의 구현을 가능하게 한다. 또한 직류측 커패시터 전압제어를 위해 샘플-흘드와 비례제어빙식을 사용하므로 기존의 저역통괴필터와 PI 제어시 적분기로 인한 지연을 없앨 수 있어 빠르고 우수한 과도응답특성을 나타낸다. 전원전압과 보상전류, 스위치 상태에 따라 8개의 모드로 나누어 능동전력필터의 동작을 설명하였으며, 제안한 방법의 성능을 실험을 통해 확인하였다.

  • PDF

인가전압의 특성을 고려한 주거용 부하의 전류성분 추정기법 개발 (Development of Current Harmonics Estimation Method by Considering the Characteristics of Input Voltage)

  • 지평식
    • 전기학회논문지P
    • /
    • 제60권4호
    • /
    • pp.181-185
    • /
    • 2011
  • Due to the increasing of nonlinear loads such as converters and inverters connected to the electric power distribution system, and extensive application of harmonic generation sources with power electronic devices, disturbance of the electric power system and its influences on industries have been continuously increasing. Thus, it is difficult to construct accurate load model for active and reactive power in environments with harmonics. In this research, we develop current harmonics estimation method based on Extreme Learning Machine (ELM) with fast learning procedure for residential loads. Using data sets acquired from various residential loads, the proposed method has been intensively tested. As the experimental results, we confirm that the proposed method makes it possible to effective estimate current harmonics for various input voltage.

가변 전류루프이득을 가지는 Power Conditioner (Power Conditioner with Variable Current Loop Gain)

  • 정창용;이영운;백주원;유동욱;안창모;조기연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1101-1104
    • /
    • 2001
  • This paper describes a newly developed power conditioner with variable current loop gain. The power conditioner consists of a do-link capacitor and three phase inverter with coupled inductor. This system is very well operated to compensate current harmonics and asymmetries caused by nonlinear load and unbalance loads. The power conditioner shapes the source current sinusoidal in phase with source voltage. A 100kVA power conditioner was built and the controller is realized with DSP Experimental results for many load conditions are presented to verify the performance of the controller.

  • PDF