• Title/Summary/Keyword: Nonlinear Distortion

Search Result 387, Processing Time 0.024 seconds

Analysis on the Effect of Arcing Fault and CT Saturation on Distance Algorithms (아크고장 및 CT포화가 거리계전 알고리즘에 미치는 영향분석)

  • Son, Chun-Myung;Kang, Sang-Hee;Kang, Yong-Choel;Rebizant, Waldemar
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.50-52
    • /
    • 2002
  • Distance relays need accurate current and voltage for determining the trip ignition. Therefore we must analyze nonlinear phenomena which cause distortion in signals first of all. This paper presents the effect of some distortion(arcing fault and current transformer saturation) in power system. The saturation of a current transformer distorts input current of a distance relay and arcing faults make current and voltage to be changed. This paper describes modeling methods of a current transformer and arcing faults, and describes the simulation result of two distance relay algorithms (discrete fourier transform and modified differential equation methods)

  • PDF

Output LC Filter Design of Voltage Source Inverter Considering the Performance of Controller (제어기응답을 고려한 전압형 인버터의 출력 LC필터 설계)

  • Kim, Jae-Sig;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1077-1079
    • /
    • 2000
  • In this paper. the design procedure of the inverter output filter is described. The transfer function of the filter output voltage to the load current is described with the capacitor value and the system time constant including the controller. This means that the relation between the filter capacitor value and the system time constant is given as the closed form. By using the above closed form. the capacitor value can be calculated with the system time constant which can be implemented practically not using the try and error method. And as the effect of the load current to the voltage distortion can be calculated from the closed form, it can be verified how much the voltage distortion is effected when the nonlinear load is connected.

  • PDF

A Study on the two phase sinusoidal voltage Controlled Oscillator with Low Distortion (저왜율을 갖는 2상정현파 전압제어 발진기에 관한 연구)

  • 이성백;이윤종
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.12 no.5
    • /
    • pp.527-534
    • /
    • 1987
  • Two phase voltage controlled oscillation was realized by using the Electronic analog simulation of nonlinear simultaneous 2st order equation in terms of vibration and it's usefullness was sustined. Sinde it is complex and expensive to implement the circuits actually which composits and multiplicate the two phase signal squared respectively, this paper is obtained the simplificotion and switching circuit. The circuit introducced in this paper had propotionality of frequency to control input voltage, rapid response time, and little phase error, also this circuit operated with very low THD(Total Harmonic Distortion) and constant amplitude at higher than 10 :1 of frequency ratio.

  • PDF

A Study on Linearization of Intermodulation Distortion for WCDMA

  • Jeon, Joong-Sung;Kim, Dong-il
    • Journal of Navigation and Port Research
    • /
    • v.28 no.2
    • /
    • pp.149-154
    • /
    • 2004
  • A linear power amplifier is particularly emphasized on the system using a linear modulations, such as 16QAM and QPSK with pulse shaping, because intermodulation distortion which causes adjacent channel interference and co-channel interference is mostly generated in a nonlinear power amplifier. In this paper, parameters of a linearization loop, such as an amplitude imbalance, a phase imbalance and a delay mismatch, are briefly analyzed to get a specific cancellation performance and linearization bandwidth Experimental results are presented for IMT-2000 frequency band The center frequency of the feedforward amplifier is 2140MHz with 60MHz bandwidth When the average output power of feedforward amplifier is 20 Watt, the intermodulation cancellation performance is more than 28dB. In this case, the output power of feedforward amplifier reduced 3.5dB because of extra delay line loss and coupling loss. The feedforward amplifier efficiency is more than 7% for multicarrier signals.

A Study on Measurement and Analysis of Harmonics in Substation (변전소 고조파 측정 및 분석에 관한 연구)

  • Han Mu-Ho;Park Tae-Joon;Lee Seung-Hee;Lee Chi-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.438-441
    • /
    • 2001
  • Nonlinear loads change the sinusoidal nature of the ac power current, thereby resulting in the flow of harmonic currents in the ac power system that can cause interference with communication circuits and other type of equipment. To minimize the damage, it is needed to limit harmonics current and voltage. Harmonic measurement system was developed to measure individual voltage and current harmonic continuously and save harmonic data on computer. We measured all 154kV feeders in a steel making company substation. Voltage and current distortion limits for general transmission systems was suggested We found some feeders exceeded current distortion limits. As result voltage harmonic exceeded standard limits.

  • PDF

Learning the nonlinearity of a camera calibration model using GMDH algorithm (GMDH 알고리즘에 의한 카메라 보정 모델의 비선형성 학습)

  • Kim, Myoung-Hwan;Do, Yong-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.109-115
    • /
    • 2005
  • Calibration is a prerequisite procedure for employing a camera as a 3D sensor in an automated machines like robots. As accurate sensing is possible only when the vision sensor is calibrated accurately, many different approaches and models have been proposed for increasing calibration accuracy. Particularly an important factor which greatly affects the calibration accuracy is the nonlinearity in the mapping between 3D world and corresponding 2D image. In this paper GMDH algorithm is used to learn the nonlinearity without physical modelling. The technique proposed can be effective in various situations where the levels of noises and characteristics of nonlinear distortion are different. In simulations and an experiment, the proposed technique showed good and reliable results.

Quantification of nonlinear seismic response of rectangular liquid tank

  • Nayak, Santosh Kumar;Biswal, Kishore Chandra
    • Structural Engineering and Mechanics
    • /
    • v.47 no.5
    • /
    • pp.599-622
    • /
    • 2013
  • Seismic response of two dimensional liquid tanks is numerically simulated using fully nonlinear velocity potential theory. Galerkin-weighted-residual based finite element method is used for solving the governing Laplace equation with fully nonlinear free surface boundary conditions and also for velocity recovery. Based on mixed Eulerian-Lagrangian (MEL) method, fourth order explicit Runge-Kutta scheme is used for time integration of free surface boundary conditions. A cubic-spline fitted regridding technique is used at every time step to eliminate possible numerical instabilities on account of Lagrangian node induced mesh distortion. An artificial surface damping term is used which mimics the viscosity induced damping and brings in numerical stability. Four earthquake motions have been suitably selected to study the effect of frequency content on the dynamic response of tank-liquid system. The nonlinear seismic response vis-a-vis linear response of rectangular liquid tank has been studied. The impulsive and convective components of hydrodynamic forces, e.g., base shear, overturning base moment and pressure distribution on tank-wall are quantified. It is observed that the convective response of tank-liquid system is very much sensitive to the frequency content of the ground motion. Such sensitivity is more pronounced in shallow tanks.

A Study on the Series and Parallel Resonant Filters for Harmonic Currents Reduction of Nonlinear Loads (비선형부하의 고조파전류 저감을 위한 직렬 및 병렬 동조필터에 관한 연구)

  • 김경철;강윤모;백승현;김종욱
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.113-118
    • /
    • 2003
  • This paper characterizes typical nonlinear loads into two types of harmonic sources, i.e., harmonic voltage source and harmonic current source. A series resonant filter is very effective in harmonic reduction for harmonic voltage source type of nonlinear loads such as personal computer loads with smoothing dc capacitors. A parallel resonant filter is suited for current source type of nonlinear loads such as ac drives with smoothing dc reactors. General compensation characteristics and comparison of series and parallel resonant filters are given analytically and experimentally. Compliance with IEC Std 1000-3-2 has been evaluated for limiting harmonic distortion.

Image Recovery Using Nonlinear Modeling of Industrial Radiography (산업용방사선영상의 비선형모델링에 의한 영상복구)

  • Hwang, Jung-Won;Hwang, Jae-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.4
    • /
    • pp.71-77
    • /
    • 2008
  • This paper presents a methodology for recovering the industrial radiographic images from the effects of nonlinear distortion. Analytical approach based on the inverse square law and Beer's law is developed in order to improve a mathematic model of nonlinear type. The geometric effect due to dimensions of the radioactive source appeals on the digitized images. The relation that expresses parameters values(angle, position, absorption coefficient, length, width and pixel account) is defined in this model, matching with the sample image. To perform the search for image recovery most similar to the model, a correction procedure is designed. The application of this method on the radiographic images of steel tubes is shown and recovered results are discussed.

Adaptive Digital Predistorter Using the NLMS Algorithm for the Nonlinear Compensation of the OFDM Communication System (OFDM통신시스템의 비선형 왜곡 보상을 위한 NLMS 알고리즘 방식의 디지털 적응 전치 왜곡기)

  • Kim Sang-Woo;Hieu Nguyen Thanh;Kang Byoung-Moo;Ryu Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.4 s.95
    • /
    • pp.389-396
    • /
    • 2005
  • In this paper, we propose a pre-distortion method using the NLMS(Normalized Least Mean Square) algorithm to cope with hish PAPR(Peak to Average Power Ratio) problem in OFDM communication system. This proposed scheme estimates the distortion characteristics of HPA, and changes the characteristic against the distortion. Therefore, it can be shown that the adaptive characteristic of the NLMS pre-distorter is good to track the various nonlinear characteristic of HPA, even though HPA characteristic is changed by temperature variation or aging. From the performance analysis, SNR efficiency of NLMS pre-distorter is about $0.5\;\cal{dB}$ less than that of common numerical non-adaptive pre-distorter, when IBO(Input Back Off) is $0\;\cal{dB}$. However, the NLMS pre-distorter is better than the common numerical pre-distorter, because these two pre-distorters have similar performance in higher than $3\;\cal{dB}$ IBO, and the NLMS pre-distorter maintains the constant performance even though characteristic of HPA is changed.