• Title/Summary/Keyword: Noninvasive diagnosis

Search Result 166, Processing Time 0.031 seconds

Development of a Prototype Patient Monitoring System with Module-Based Bedside Units and Central Stations: Overall Architecture and Specifications (모듈형 환자감시기와 중앙 환자감시기로 구성되는 환자감시시스템 시제품의 개발: 전체구조 및 사양)

  • Woo, E.J.;Park, S.H.;Jun, B.M.;Moon, C.W.;Lee, H.C.;Kim, S.T.;Kim, H.J.;Seo, J.J.;Chae, K.M.;Park, J.C.;Choi, K.H.;Lee, W.J.;Kim, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.315-319
    • /
    • 1996
  • We have developed a prototype patient monitoring system including module-based bedside units, interbed network, and central stations. A bedside unit consists of a color monitor and a main CPU unit with peripherals including a module controller. It can also include up to 3 module cases and 21 different modules. In addition to the 3-channel recorder module, six different physiological parameters of ECG, respiration, invasive blood pressure, noninvasive blood pressure, body temperature, and arterial pulse oximetry with plethysmogaph are provided as parameter modules. Modules and a module controller communicate with up to 1Mbps data rate through an intrabed network based on RS-485 and HDLC protocol. Bedside units can display up to 12 channels of waveforms with any related numeric informations simultaneously. At the same time, it communicates with other bedside units and central stations through interbed network based on 10Mbps Ethernet and TCP/IP protocol. Software far bedside units and central stations fully utilizes gaphical user interface techniques and all functions are controlled by a rotate/push button on bedside unit and a mouse on central station. The entire system satisfies the requirements of AAMI and ANSI standards in terms of electrical safety and performances. In order to accommodate more advanced data management capabilities such as 24-hour full disclosure, we are developing a relational database server dedicated to the patient monitoring system. We are also developing a clinical workstation with which physicians can review and examine the data from patients through various kinds of computer networks far diagnosis and report generation. Portable bedside units with LCD display and wired or wireless data communication capability will be developed in the near future. New parameter modules including cardiac output, capnograph, and other gas analysis functions will be added.

  • PDF

Added Value of Chemical Exchange-Dependent Saturation Transfer MRI for the Diagnosis of Dementia

  • Jang-Hoon Oh;Bo Guem Choi;Hak Young Rhee;Jin San Lee;Kyung Mi Lee;Soonchan Park;Ah Rang Cho;Chang-Woo Ryu;Key Chung Park;Eui Jong Kim;Geon-Ho Jahng
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.770-781
    • /
    • 2021
  • Objective: Chemical exchange-dependent saturation transfer (CEST) MRI is sensitive for detecting solid-like proteins and may detect changes in the levels of mobile proteins and peptides in tissues. The objective of this study was to evaluate the characteristics of chemical exchange proton pools using the CEST MRI technique in patients with dementia. Materials and Methods: Our institutional review board approved this cross-sectional prospective study and informed consent was obtained from all participants. This study included 41 subjects (19 with dementia and 22 without dementia). Complete CEST data of the brain were obtained using a three-dimensional gradient and spin-echo sequence to map CEST indices, such as amide, amine, hydroxyl, and magnetization transfer ratio asymmetry (MTRasym) values, using six-pool Lorentzian fitting. Statistical analyses of CEST indices were performed to evaluate group comparisons, their correlations with gray matter volume (GMV) and Mini-Mental State Examination (MMSE) scores, and receiver operating characteristic (ROC) curves. Results: Amine signals (0.029 for non-dementia, 0.046 for dementia, p = 0.011 at hippocampus) and MTRasym values at 3 ppm (0.748 for non-dementia, 1.138 for dementia, p = 0.022 at hippocampus), and 3.5 ppm (0.463 for non-dementia, 0.875 for dementia, p = 0.029 at hippocampus) were significantly higher in the dementia group than in the non-dementia group. Most CEST indices were not significantly correlated with GMV; however, except amide, most indices were significantly correlated with the MMSE scores. The classification power of most CEST indices was lower than that of GMV but adding one of the CEST indices in GMV improved the classification between the subject groups. The largest improvement was seen in the MTRasym values at 2 ppm in the anterior cingulate (area under the ROC curve = 0.981), with a sensitivity of 100 and a specificity of 90.91. Conclusion: CEST MRI potentially allows noninvasive image alterations in the Alzheimer's disease brain without injecting isotopes for monitoring different disease states and may provide a new imaging biomarker in the future.

Technical Feasibility of Quantitative Measurement of Various Degrees of Small Bowel Motility Using Cine Magnetic Resonance Imaging

  • Ji Young Choi;Jihye Yun;Subin Heo;Dong Wook Kim;Sang Hyun Choi;Jiyoung Yoon;Kyuwon Kim;Kee Wook Jung;Seung-Jae Myung
    • Korean Journal of Radiology
    • /
    • v.24 no.11
    • /
    • pp.1093-1101
    • /
    • 2023
  • Objective: Cine magnetic resonance imaging (MRI) has emerged as a noninvasive method to quantitatively assess bowel motility. However, its accuracy in measuring various degrees of small bowel motility has not been extensively evaluated. We aimed to draw a quantitative small bowel motility score from cine MRI and evaluate its performance in a population with varying degrees of small bowel motility. Materials and Methods: A total of 174 participants (28.5 ± 7.6 years; 135 males) underwent a 22-second-long cine MRI sequence (2-dimensional balanced turbo-field echo; 0.5 seconds per image) approximately 5 minutes after being intravenously administered 10 mg of scopolamine-N-butyl bromide to deliberately create diverse degrees of small bowel motility. In a manually segmented area of the small bowel, motility was automatically quantified using a nonrigid registration and calculated as a quantitative motility score. The mean value (MV) of motility grades visually assessed by two radiologists was used as a reference standard. The quantitative motility score's correlation (Spearman's ρ) with the reference standard and performance (area under the receiver operating characteristics curve [AUROC], sensitivity, and specificity) for diagnosing adynamic small bowel (MV of 1) were evaluated. Results: For the MV of the quantitative motility scores at grades 1, 1.5, 2, 2.5, and 3, the mean ± standard deviation values were 0.019 ± 0.003, 0.027 ± 0.010, 0.033 ± 0.008, 0.032 ± 0.009, and 0.043 ± 0.013, respectively. There was a significant positive correlation between the quantitative motility score and the MV (ρ = 0.531, P < 0.001). The AUROC value for diagnosing a MV of 1 (i.e., adynamic small bowel) was 0.953 (95% confidence interval, 0.923-0.984). Moreover, the optimal cutoff for the quantitative motility score was 0.024, with a sensitivity of 100% (15/15) and specificity of 89.9% (143/159). Conclusion: The quantitative motility score calculated from a cine MRI enables diagnosis of an adynamic small bowel, and potentially discerns various degrees of bowel motility.

The Utility of Immunological Markers and Pulmonary Function Test in the Early Diagnosis of Pulmonary Involvement in the Patients with Rheumatoid Arthritis (류마티스 관절염환자에서 폐침범의 진단에 있어서 면역학적 지표와 폐기능 검사의 유용성)

  • Lee, Dong-Suk;Lee, Chang-Beam;Koh, Hee-Kwan;Moon, Doo-Seop;Lee, Jae-Young;Lee, Kyung-Sang;Yang, Suck-Chul;Yoon, Ho-Joo;Bae, Sang-Cheol;Shin, Dong-Ho;Kim, Seong-Yoon;Park, Sung-Soo;Lee, Jung-Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.878-887
    • /
    • 1995
  • Background: It is reported that frequency of pulmonary involvement in the patients with rheumatoid arthritis reaches 10 to 50% and pulmonary involvement is a principal cause of death. As immunology and radiology has developed, interest for the early diagnosis of pulmonary involvement is increasing. Method: Among the patients at Hanyang University Hospital from March, 1990 to July, 1995, we compared the 29 patients having pulmonary involvement with the 18 patients controls in clinical and chest high resolution computed tomography(HRCT) findings by immunological markers and findings of pulmonary function test. We sought useful markers for early diagnosis of pulmonary involvement with noninvasive investigations. Results: The ratio of males to females was 14 : 15 in the group of pulmonary involvement, and all of the 18 patients were females in the control group. Smoking history was 31%(9/29) in the former group and none in the latter group. Rheumatoid factor(RF) was positive in 95.5%(28/29) of the pulmonary involvement group and in 100%(18/18) of the control group(p=0.12). Antiperinuclear factor(APF) showed a significant difference: 86.9%(20/23, average value: 2.0) was positive in the pulmonary involvement group and 50%(8/16, average value: 1.1) in the control group(p=0.04). Antinuclear antibody(ANA) was positive in 60.7%(17/28) of the pulmonary involvement group and in 72.2%(13/18) of the control group(p=0.33). Cryoglobulin also showed a significant difference: 72%(18/25) in the pulmonary involvement group was positive and 56.2%(9/16) in the control group was positive(p=0.02). Bony erosion was positive in 61.5%(16/26) of the pulmonary involvement group and in 77.7%(14/18) of the control group(p=0.8). On the pulmonary function test, the average value of alveolar volume corrected diffusion capacity and residual volume in the pulmonary involvement group and in the control group were 1.07mmol/rnin/KPa(predicted value: 64.2%), 1.32L(predicted value: 70%) and 1.44mmol/min/KPa, 3.75L(predicted value: 86.6%), respectively(p=0.003, p=0.004), showing a significant difference. Conclusion: APF or cryoglobulin on the serological test, the measurement of residual volume and alveolar volume corrected diffusion capacity may be used as effective markers in the diagnosis of pulmonary involvement of the patients with rheumatoid arthritis.

  • PDF

Usefulness of a Alvarado Scoring System for the Diagnosis of Acute Appendicitis in Children (소아 충수돌기염 진단에서 Alvarado Scoring System의 유용성)

  • Yang, Eun Seok;Yoon, Sung Kwan;Kim, Eun Young;Rho, Young Il;Park, Sang Kee;Park, Yeong Bong;Mun, Gyeong-Rae
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 2004
  • Purpose: Alvarado scoring system was evaluated regarding its usefulness for the early diagnosis of acute appendicitis in adult and in reduction of the incidence of negative appendicectomies. To evaluate the accuracy of diagnosing appendicitis using the Alvarado score in children. Methods: Prospectively, we surveyed 122 patients (male 67, female 55) suffering from abdominal pain, who had visited to the emergency department of Chosun University Hospital from June 2002 to May 2003. The Alvarado score has been computed from the white blood cell count, neutrophil count, body temperature, resistance in the right lower quadrant, length of symptoms, nausea and vomiting. Each patient was evaluated by a pediatric resident and then by a general surgeon independently. Results: Out of 170 total children who visited to the emergency department due to abdominal pain, 122 patients were associated with appendicitis. A total of 122 patients (67 male and 55 female) were visited to the emergency room with suspected appendicitis. From 105 operated patients, 92 (87.6%) were diagnosed acute appendicitis and erronous diagnostic rate was 12.4%, pathologically. Mean alvarado score of appendicitis group was $5.40{\pm}1.24$ whereas those of non-appendicitis group was $3.73{\pm}1.82$ (p<0.05). From 6 Alvarado score high sensitivity (86.4%) and high specificity (80.0%) were observed. Sensitivity of ultrasonography or computed tomography was 92.5%. Conclusion: We found that Alvarado score system is a noninvasive, safe diagnostic method, which is simple, reliable and repeatable. Alvarado score is useful system for a first, rapid and economic evaluation for the appendicitis in children.

  • PDF

Echocardiographic Diagnosis of Pulmonary Arterial Hypertension in Chronic Lung Disease with Hypoxemia (만성 저산소성 폐질환의 폐동맥 고혈압에 대한 심초음파 검사)

  • Chang, Jung-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.846-855
    • /
    • 1999
  • Background : Secondary pulmonary hypertension is an important final endpoint in patients with chronic hypoxic lung disease, accompanied by deterioration of pulmonary hemodynamics. The clinical diagnosis of pulmonary hypertension and/or cor pulmonale could be difficult, and simple noninvasive evaluation of pulmonary artery pressures has been an relevant clinical challenge for many years. Doppler echocardiography might to be a more reliable method for evaluating pulmonary hemodynamics in such patients in terms of the accuracy, reproducibility and easiness for obtaining an appropriate echocardiographic window than M-mode echocardiography. The aim of this study was to assess echocardiographic parameters associated with pulmonary arterial hypertension, defined by increasing right ventricular systolic pressure(RVSP), calculated from trans-tricuspid gradient in patients with chronic hypoxic lungs. Method : We examined 19 patients with chronic hypoxic lung disease, suspected pulmonary hypertension under the clinical guidelines by two dimensional echocardiography via the left parasternal and subcostal approach in a supine position. Doppler echocardiography measured RVSP from tricuspid regurgitant velocity in continuous wave with 2.5MHz transducer and acceleration time(AT) on right ventricular outflow tract in pulsed wave for the estimation of pulmonary arterial pressure. Results : On echocardiography, moderate to severe degree of pulmonary arterial hypertension was defined as RVSP more than 40mmHg, presenting tricuspid regurgitation. Increased right ventricular endsystolic diameter and shortened AT were noted in the increased RVSP group. Increased RVSP was correlated negatively with the shortening of AT. Other clinical data, including pulmonary functional parameters, arterial blood gas analysis and M mode echocardiographic parameters were not changed significantly with the increased RVSP. Conclusion : These findings suggest that shortened AT on pulsed doppler can be useful when quantifying pulmonary arterial pressure with increased RVSP in patients with chronic lung disease with hypoxemia. Doppler echocardiography in pulmonary hypertension of chronic hypoxic lungs is an useful option, based on noninvasiveness under routine clinical practice.

  • PDF

Diagnostic Efficacy of FDG-PET in Solitary Pulmonary Nodule (고립성폐결절에서 FDG-PET의 진단적 유용성)

  • Kim, Woo-Jin;Yim, Jae-Joon;Yoo, Chul-Gyu;Kim, Young-Whan;Shim, Young-Soo;Han, Sung-Koo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.6
    • /
    • pp.1263-1270
    • /
    • 1997
  • Background : Differentiation of malignity and benignity is crucial for management of solitary pulmonary nodule(SPN). Clinical parameters such as patient's age, nodule size, smoking history, doubling time, typical calcification in X-ray and CT findings have been reported as helpful in this purpose. However, in most cases, these parameters are not conclusive. Glucose metabolism is increased in cancer tissues including lung cancer tissues. After uptake of 2-[F-18]-fluoro-2-deoxy-D-glucose(FDG), the glucose analogue, by cancer cell, FDG is trapped in the cell without further metabolism after phosphorylation. Thus, hypermetabolic focus in FDG-positron emission tomography (PET) imaging suggest malignancy. We evaluated the diagnostic efficacy of FDG-PET imaging in distinguishing malignant and benign SPN. Methods : We evaluated 28 patients with SPN from Jan. 1995 to Jan. 1997. CT scan of chest and whole-body FDG-PET imaging were performed in all patients. Histologic diagnosis was confirmed by transthoracic fine needle aspiration and biopsy, bronchoscopic biopsy and open thoracotomy. Results : Of the 28 SPN's, 22 nodules were malignant and 6 nodules were benign. FDG-PET imaging diagnosed all malignant nodules correctly as positive, and diagnosed 4 of 6 benign nodules correctly as negative. One tuberculous granuloma and one aspergilloma showed hypennetabolic focus and were diagnosed falsely positve with FDG-PET imaging. In the diagnosis of SPN with FDG-PET, sensitivity and specificity were 100% and 66.7%, positive predictive value and negative predictive value were 92% and 100%. Conclusion : FDG-PET imaging is highly useful noninvasive diagnostic tool in distinguishing between malignant SPN and benign SPN.

  • PDF

The Clinical Usefulness of Transbronchial Lung Biopsy in Critically III Patients with Pulmonary Infiltrates of Uncertain Etiology (폐 침윤과 호흡부전을 동반한 중환자에서 경기관지폐생검의 임상적 유용성에 관한 연구)

  • Jang, Eun-Ha;Koh, Youn-Suck;Shim, Tae-Sun;Lim, Chae-Man;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Go, Yun-Seok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.2
    • /
    • pp.236-245
    • /
    • 2000
  • Background: Transbronchial lung biopsy(TBLB) has known to yield useful information for pulmonary infiltrates of uncertain etiology, However, its safety and usefulness have not been conclusive in the critically ill patients with respiratory failure. Moreover, TBLB has not been recommended for patients with mechanical ventilation. This study was conducted to investigate the diagnostic values and risks of Will performed on critically ill patients at bedside to obtain information on the pulmonary infiltrate of unknown etiology. Methods: Twenty patients(21 admissions with 23 cases) with diffuse pulmonary infiltrates who were treated in a medical intensive care unit of a tertiary referral hospital from January 1994 to May 1998, were enrolled for the study. Their medical records were retrospectively reviewed. TBLB was opted when a noninvasive diagnostic work-up failed to reveal the cause for the pulmonary infiltrate. The procedure was performed at patients' bedside without assistance of fluoroscopy. Bronchial washing or bronchoalveolar lavage was performed on the same pulmonary segment before performing TBLB. Results: Adequate specimens were obtained in 18 cases(78%). TBLB provided a specific diagnosis in two cases. The results of TBLB suggested the underlying etiology in 9 cases; bacterial pneumonitis(4), hypersensitivity pneumonitis(1), polymyositis(1), radiation fibrosis(1), idiopathic pulmonary fibrosis(1), and BOOP(1). Therapeutic decisions were altered in 11 cases(47.8%) based on the TBLB results. Pneumocystis carinii was found in the BAL fluid of another case. Ten patients with a therapeutic change and ten patients without a management change had mortality rates of 40% and 80%, respectively. The APACHE III scores were significantly higher in patients with complications($72.8{\pm}21.8$) compared with those without complications ($48.3{\pm}18.9$)(p<0.05). The complication rates were higher in those with mechanical ventilation(50%) than in those without Mechanical ventilation(33%), but the difference was not statistically significant(p=0.3). Conclusions: TBLB may be a useful diagnostic option for critically ill patients with unknown cause of pulmonary infiltrates. However, it should be cautious be used with care for patients with mechanical ventilation or for severely ill patients.

  • PDF

Comparison of Thallium-201 Scan and Tc-99m Sestamibi Scan in the Differential Diagnosis of Breast Mass (유방암 진단에 있어서 탈륨스캔과 Tc-99m MIBI 스캔의 비교)

  • Cho, Ihn-Ho;Won, Kyu-Jang;Lee, Hyung-Woo;Lee, Soo-Jung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.76-83
    • /
    • 1999
  • Purpose: We performed this study to compare T1-201 and Tc-99m MIBI scans for the differentiation of malignant from benign breast mass. Materials and Methods: Thirty-eight female patients underwent T1-201 breast scan and thirty-two of them also underwent Tc-99m MIBI scan of the breast. After intravenous injection of 74-111 MBq of T1-201, early (10 minutes) and delayed (3 hours) images were obtained. Then, 555-740 MBq of Tc-99m MIBI was injected and images after 30 minutes were obtained. We compared T1-201 and Tc-99m MIBI scans with pathologic results. Results: Twenty-three patients were confirmed to have infiltrating duct carcinoma and fifteen patients to have benign breast mass by excisonal biopsy. The sensitivity of early and delayed T1-201 scan and Tc-99m MIBI scan in the detection of malignant breast lesion were 100% (23/23), 82% (18/22), and 90% (18120), respectively. The sensitivity of early T1-201 scan was significantly higher than that of delayed T1-201 scan (p<0.05). The specificity of early and delayed T1-201 scan and Tc-99m MIBI scan were 73% (l1/15), 73% (l1/15) and 83% (10/12), respectively (p: not significant). Three patients out of nine with fibroadenoma and one patient with atypical duct hyperplasia were false positive in both early and delayed T1-201 scans. The size of fibroadenoma with false positive in early and delayed T1-201 scan (4 cases) was larger than that of 11 fibroadenoma with true negative scan (p<0.01). Metastatic axillary lymph node involvement was present in fifteen patients. The sensitivity to detect metastatic nodes was 38% (5/13) for early T1-201 images, 15% (2/13) for delayed T1-201 images, 58% (7/12) for Tc-99m MIBI planar images and 67% (4/6) for Tc-99m MIBI SPECT. The sensitivity of Tc-99m MIBI planar or SPECT was significantly higher than that of delayed T1-201 images (p<0.05). Conclusion: Early T1-201 and Tc-99m MIBI scan are useful noninvasive methods to differentiate malignant from benign mass of breast Tc-99m MIBI scan was sensitive in detecting axillary lymph node metastasis in patients with breast cancer.

  • PDF

Canine MR Images from 3T Active-Shield MRI System (3T 능동차폐형 자기공명영상 장비로부터 얻어진 개의 자기공명영상)

  • Choe, Bo-Young;Park, Chi-Bong;Kang, Sei-Kwon;Chu, Myoung-Ja;Kim, Euy-Neyng;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.113-124
    • /
    • 2001
  • For veterinary imaging diagnosis, we obtained MR images of the canine brain, spine, kidney and pelvis from 3T MRI system which was equipped with the world first 3T active shield magnet. Spin echo (SE) and fast Spin Echo (FSE) images were obtained from the canine brain, spine, kidney and pelvis of normal and sick dogs using a homemade birdcage and transverse electromagnetic (TEM) resonators operating in quadrature and tuned to 128 MHz. In addition, we employed a homemade saddle shaped RF coil. Typical common acquisition parameters were as follows: matrix=512$\times$512, field of view (FOV)=20cm, slice thickness=3 w, number of excitations (NEX)=1. For T1-weighted MR images, we used TR=500 ms, TE=10 or 17.4 ms. For T2-weighted MR images, we used TR=4000 ms, TE=108 ms. Signal to noise ratio (SNR) of 3T system was measured 2.7 times greater than that of prevalent 1.57 system. The high resolution images acquired in this study represent more than a 4-fold increase in in-plane resolution relative to conventional images obtained with a 20 cm field of view and a 5 mm slice thickness. MR images obtained from 3T system revealed numerous small venous structures throughout the image plane and provided reasonable delineation between gray and white matter The present results demonstrate that the MR images from 3T system could provide better diagnostic quality of resolution and sensitivity than those of 1.5T system. The elevated SNR observed in the 3T high field magnetic resonance imaging can be utilized to acquire images with a level of resolution approaching the microscopic structural level under in vivo conditions. These images represent a significant advance in our ability to examine small anatomical features with noninvasive imaging methods. Moreover, MRI technique could begin to apply for veterinary medicine in Korea.

  • PDF