• 제목/요약/키워드: Noncontact

검색결과 253건 처리시간 0.026초

시설물 모니터링을 위한 비접촉식 진동측정시스템의 개발 (Development of the Noncontact Vibrometer for the Monitering System of Infrastructures)

  • 정요찬;곽종원;최은석;진원종;이정우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.563-566
    • /
    • 2005
  • This study deals with the development of noncontact vibration measuring system for monitoring the safety of structures as bridges, buildings, stadiums, tall chimneys, and dams where vibration measurements are very difficult because of various restrictions. Final object is to develope the system and be commercial by theoretical and experimental studies using IT technology for three years.

  • PDF

Rail Inspection Using Noncontact Laser Ultrasonics

  • Kim, Nak-Hyeon;Sohn, Hoon;Han, Soon-Woo
    • 비파괴검사학회지
    • /
    • 제32권6호
    • /
    • pp.696-702
    • /
    • 2012
  • In this study, a noncontact laser ultrasonic system is proposed for rail defect detection. An Nd-Yag pulse laser is used for generation of ultrasonic waves, and the corresponding ultrasonic responses are measured by a laser Doppler vibrometer. For the detection of rail surface damages, the shape of the excitation laser beam is transformed into a line. On the other hand, a point source laser beam is used for the inspection of defects inside a rail head. Then, the interactions of propagating ultrasonic waves with defects are examined using actual rail specimens. Amplitude attenuation was mainly observed for a surface crack, and reflections were most noticeable from an internal damage. Finally, opportunities and challenges associated with real-time rail inspection from a high-speed train are discussed.

Noncontact Fatigue Crack Evaluation Using Thermoelastic Images

  • Kim, Ji-Min;An, Yun-Kyu;Sohn, Hoon
    • 비파괴검사학회지
    • /
    • 제32권6호
    • /
    • pp.686-695
    • /
    • 2012
  • This paper proposes a noncontact thermography technique for fatigue crack evaluation under a cyclic tensile loading. The proposed technique identifies and localizes an invisible fatigue crack without scanning, thus making it possible to instantaneously evaluate an incipient fatigue crack. Based on a thermoelastic theory, a new fatigue crack evaluation algorithm is proposed for the fatigue crack-tip localization. The performance of the proposed algorithm is experimentally validated. To achieve this, the cyclic tensile loading is applied to a dog-bone shape aluminum specimen using a universal testing machine, and the corresponding thermal responses induced by thermoelastic effects are captured by an infrared camera. The test results confirm that the fatigue crack is well identified and localized by comparing with its microscopic images.

MR 센서와 PIC를 이용한 비접촉식 정밀 유량계 개발에 관한 연구 (A Study on Development of a Noncontact Precision Flow-meter Using MR Sensor and PIC)

  • 이승희;이민철;고석조;장용석;최문호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1063-1066
    • /
    • 2003
  • A flow-meter and its measurement controller was developed for a hydraulic system. This study, for development of positive displacement flow-meter, consist of PIC(Peripheral Interface Controller) controller with MR(Magneto-resistive) sensors. This flow-meter is used valve position indicator for valve control system by hydraulic. The MR sensors are used for the rotation of OVAL gear that detecting device. In the ship environments, consideration that necessary explosive proof. Thus electro device or electro flow-meter needs explosion design for electric circuit. We designed noncontact type flow-meter and evaluated the safety and measuring abilities.

  • PDF

자력을 이용한 비접촉식 박판 가진장치 개발에 관한 연구 (Study on the Development of Noncontact Vibration Exciter for Thin Plates Using Magnetism)

  • 허관도;손인수
    • 한국소음진동공학회논문집
    • /
    • 제26권1호
    • /
    • pp.104-109
    • /
    • 2016
  • The noncontact vibration exciter system using the electro-magnet for a thin plate is studied in this paper. Based on the Euler-Bernoulli beam theory, the equation of motion of thin plate is derived. The main purpose of this experiment is to match the input-frequency and response frequency of thin plate. The test equipment is configured to vibrate on both sides of the thin plate using the electro-magnet. Two frequencies(input frequency and response frequency) in our experiments show very good agreement. This study results will contribute to basic investigate of an alternative air-knife system for the steel industry.

Performance Comparison of the Railway Traction IPM Motors between Concentrated Winding and Distributed Winding

  • Park, Chan-Bae;Lee, Byung-Song;Lee, Hyung-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.118-123
    • /
    • 2013
  • This paper presents performance comparison between concentrated winding and distributed winding of IPMSM (Interior Permanent Magnet Synchronous Motors) which is recently used for light-weight railway applications. Motors are designed on various schemes and analyzed by using FEM (Finite Element Method) instead of EMCNM (Equivalent Magnetic Circuit Network Method) in order to take into account saturation and non-linear magnetic property. The overall performance such as torque, torque ripple, losses, demagnetization, efficiency, power density and so on are investigated in detail at the rated and maximum operating speed. The results of the analysis found that both concentrated and distributed winding IPMSMs are promising candidates for high power railway traction motor.

Rectus Sheath Hematoma Caused by Noncontact Strenuous Exercise

  • Kim, Gil Hwan;Kim, Jae Hun;Kim, Ho Hyun
    • Journal of Trauma and Injury
    • /
    • 제30권4호
    • /
    • pp.227-230
    • /
    • 2017
  • Rectus sheath hematoma (RSH) is an uncommon but well-documented clinical condition. It is usually caused by direct trauma or anticoagulation, although there are many other causes. However, RSH after noncontact strenuous exercise is very rare. We present a rare case of RSH after playing volleyball without direct trauma that was successfully treated by angiographic embolization.

적외선 투과 광섬유를 이용한 비접촉식 온도 센서 개발을 위한 기초 연구 (Feasibility study on the development of noncontact temperature sensor using infrared optical fiber)

  • 유욱재;조동현;정순철;탁계래;전재훈;이봉수;손상희;조승현
    • 센서학회지
    • /
    • 제15권3호
    • /
    • pp.179-185
    • /
    • 2006
  • We have developed a noncontact temperature sensor using a silver halides infrared optical fiber. An infrared radiation from a heat source is transferred by a silver halides infrared optical fiber and measured by infrared sensors such as a thermopile and a thermal optical power-meter. The relationships between the temperature of a heat source and the output voltage of the thermopile and the optical power of a thermal optical power-meter are determined. The measurable temperature range using a thermopile and a thermal optical power-meter are from 100 to $750^{\circ}C$ and from 30 to $750^{\circ}C$ respectively. It is expected that a noncontact temperature sensor using infrared optical fiber can be developed for medical and industrial usages based on the results of this study.

비접촉식 초음파 수신기를 이용한 초음파 비선형성 측정 (Measurement of Ultrasonic Nonlinear Parameter by Using Non-Contact Ultrasonic Receiver)

  • 김종범;장경영
    • 대한기계학회논문집A
    • /
    • 제38권10호
    • /
    • pp.1133-1137
    • /
    • 2014
  • 초음파 비선형 파라미터 ${\beta}$는 재료의 미세한 변질을 평가하는데 효과적인 인자로 알려져있다. 그런데 지금까지 대부분의 연구는 접촉식 방법을 이용하여 측정하는 연구가 수행되어왔다. 그러나, 접촉식 방법은 탐촉자와 시편사이의 접촉상태가 측정결과에 큰 영향을 미치기 때문에 측정의 재현성을 보장하기 위해 탐촉자의 접촉상태를 일정하게 유지시키기 위한 부수적인 장치가 필요하다. 이러한 불편함을 해소할 목적으로 본 연구에서는 비접촉식 기법을 도입하였다. 다만 초음파의 송신은 접촉식으로 하고 수신만 비접촉식을 적용함으로써 동일한 조건에서 접촉식으로 수신한 경우와 비접촉식으로 수신한 경우를 비교하고자 하였다. 시편은 시효 처리된 알루미늄 합금을 사용하였고, 두 방식의 측정결과 비선형 파라미터 ${\beta}$의 변화는 유사하게 나타났다. 이로부터 초음파 비선형 특성의 변화를 비접촉식 수신방법으로 용이하게 평가할 수 있음을 확인하였다.

Silver Halide 광섬유를 이용한 의료용 비접촉식 온도 센서 개발 (Development of Noncontact Temperature Sensor Using Silver Halide Optical Fiber for Medical Usages)

  • 유욱재;조동현;장경원;정순철;탁계래;이봉수
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권6호
    • /
    • pp.337-342
    • /
    • 2006
  • We have developed a noncontact temperature sensor using a silver halide optical fiber. The infrared collimator and focus head are connected both ends of a silver halide optical fiber with SMA connectors and used to collimate radiations of a heat source and to focus them to infrared sensors such as a pyroelectric sensor and a thermopile sensor, respectively. The relation ships between the temperatures of a heat source and the output signals of the infrared sensors are determined to measure the surface temperature of a heat source. The measurable temperature range is from 25 to $60^{\circ}C$. It is expected that a noncontact temperature sensor using a silver halide optical fiber can be developed for medical usages such as temperature monitoring during hyperthermia, cryosurgery, laser surgery and diagnostic procedure based on the results of this study.