• Title/Summary/Keyword: Non-uniform irradiance

Search Result 7, Processing Time 0.019 seconds

The Influence of Changing PV Array Interconnections under a Non-uniform Irradiance

  • Ding, Kun;Feng, Li;Qin, Si-Yu;Mao, Jing;Zhang, Jing-Wei;Wang, Xiang;Peng, Tao;Zhai, Quan-Xin
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.631-642
    • /
    • 2016
  • Usually, the output characteristics of a photovoltaic (PV) array are significantly affected by non-uniform irradiance which is caused by ambient obstacles, clouds, orientations, tilts, etc. Some local maximum power points (LMPP) in the current-voltage (I-V) curves of a PV array can result in power losses of the array. However, the output power at the global maximum power point (GMPP) is different in different interconnection schemes in a PV array. Therefore, based on the theoretical analysis and mathematical derivation of different topological structures of a PV array, this paper investigated the output characteristics of dual series PV arrays with different interconnections. The proposed mathematical models were also validated by experimental results. Finally, this paper also concluded that in terms of performance, the total cross tied (TCT) interconnection was not always the optimal structure, especially in a dual series PV array. When one of the PV modules was severely mismatched, the TCT worked worse than the series parallel (SP) structure. This research can provide guidance for switching the interconnection to gain the greatest energy yield in a changeable- structure PV system.

ANALYSIS OF IRSIGNAL CHARACTERISTICS OF A SHIP FOR NON-UNIFORM ATMOSPHERIC CONDITIONS (비균일 대기상태를 고려한 함정의 적외선 신호 특성 분석)

  • Choi, J.H.;Kim, D.H.;Han, K.I.;Ha, N.K.;Jang, H.S.;Lee, S.H.;Kim, D.G.;Kim, T.K.
    • Journal of computational fluids engineering
    • /
    • v.22 no.1
    • /
    • pp.88-94
    • /
    • 2017
  • The IR signal entering into a sensor is composed of the following components: the self-emitted component directly from the object surface, the reflected components of the solar and sky irradiance at the object surface, and the scattered component by the atmosphere without reference to any object surfaces. The self-emitted and reflected components from the object can be lowered by the atmospheric layer between the object and the IR sensor. The principle factors influencing the atmospheric transmittance are the air temperature, the relative humidity and the observation distance. Previous studies on IR signal transmission through the atmosphere are focused on uniform atmospheric conditions and the non-uniform nature of the atmosphere was not properly treated in modeling. In this study, we use the local atmospheric transmittance to simulate the non-uniform atmosphere in analyzing the IR signal from the object surface. The results show that the nonuniform analysis of the atmosphere becomes more important as the wavelength of IR signal increases.

Performance of Photovoltaic Module according to Non-Uniform Azimuth (비동일한 방위각에 의한 PV모듈의 발전성능)

  • Kim, Hyun-Il;Park, Kyung-Eun;Lee, Ki-Ok;Kang, Gi-Hwan;Yu, Gwon-Jong;Suh, Sung-Jik
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.303-308
    • /
    • 2009
  • In 2008, the global photovoltaic(PV) market reached 5.6GW and the cumulative PV power installed totalled almost 15GW compared to 9GW in 2007. Due to a favourable feed-in-tariff, Korea emerged in 2008 as the 4th largest PV market worldwide. PV power installation rose 495.5 percent to 268MW in 2008 compare to 45MW in 2007. However many PV systems are not installed in suitable part which is concerned about geometrical factor. It is generally recognized that the actual output of PV system in field is a function of orientation, tilt angle, irradiance, temperature, soiling and various system-related losses. Thus this paper shows that a experimental result of PV modules(A group) with uniform azimuth angle and PV modules(B group) with non-uniform azimuth angle. As a result, the electrical output of B group is decreased 48.8% as compared with electrical output of A group.

  • PDF

Improved Model for Maximum Power Point Tracking (MPPT) of Solar System (태양광 시스템의 최대 전력지점 추적(MPPT) 정확도 향상을 위한 모델링)

  • Lee, YoungHyun;Lee, Jonghwan
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.1
    • /
    • pp.114-118
    • /
    • 2022
  • The photovoltaic system is affected by various conditions such as temperature and irradiance. Because non-uniform irradiation and partial shading conditions affect the entire string of cells connected in series, a bypass diode is used to bypass the current flow normally. In order to find the maximum power point in partial shade conditions, it is necessary to estimate various methods of maximum power point tracking. In this paper, the hybrid method of MPPT using Lambert W function and perturbation & observation algorithm is proposed under partial shading conditions. The simulation results are obtained using MATLAB/Simulink and shows the improvement of the accuracy of MPPT.

MEASUREMENT OF SPECTRAL-ANGULAR RADIANCES OF COASTAL WATERS IN THE KOREAN SOUTH SEA

  • Ahn, Yu-Hwan;Shanmugam, Palanisamy;Ryu, Joo-Hyung;Moon, Jeong-Eon
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.156-158
    • /
    • 2007
  • The radiance observed from the ocean depends on the illumination and viewing geometry along with the water properties, and this variation is called the bidirectional effect which is important to be considered in ocean color remote sensing. In the present study, as a preliminary step, the spectral-angular radiances in coastal water were investigated with experiments for a range of viewing geometric conditions $(0-70^{\circ})$. Over a phytoplankton-dominated water surface the upward radiance for visible and near-infrared wavelengths (example, SeaWiFS and GOCI) increased at nadir and decreased toward the near-horizon, becoming dependent of viewing angles (with higher radiance at nadir view angle and lower radiance at near-horizon viewing angle). This variations were better expressed by the Q-factor, which relates upwelling radiance to the upwelling irradiance (i.e., $Q=E_u/L_u$, also dependent on Sun's position). The Q-factor for this case was more non-uniform with the considered wavelengths and was dependent on viewing geometric conditions. These experimental results confirm the previous similar findings in other coastal waters.

  • PDF

Obtaining 3-D Depth from a Monochrome Shaded Image (단시안 명암강도를 이용한 물체의 3차원 거리측정)

  • Byung Il Kim
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.29B no.7
    • /
    • pp.52-61
    • /
    • 1992
  • An iterative scheme for computing the three-dimensional position and the surface orientation of an opaque object from a singel shaded image is proposed. This method demonstrates that calculating the depth(distance) between the camera and the object from one shaded video image is possible. Most previous research works on $'Shape from Shading$' problem, even in the $'Photometric Stereo Method$', invoved the determination of surface orientation only. To measure the depth of an object, depth of the object, and the reflectance properties of the surface. Assuming that the object surface is uniform Lambertian the measured intensity level at a given image pixel*x,y0becomes a function of surface orientation and depth component of the object. Derived Image Irradiance Equation can`t be solved without further informations since three unknown variables(p,q and D) are in one nonlinear equation. As an additional constraints we assume that surface satisfy smoothness conditions. Then equation can be solved relaxatively using standard methods of TEX>$'Calculus of VariationTEX>$'. After checking the sensitivity of the algorithm to the errors ininput parameters, the theoretical results is tested by experiments. Three objects (plane, cylinder, and sphere)are used. Thees initial results are very encouraging since they match the theoretical calculations within 20$\%$ error in simple experiments.> error in simple experiments.

  • PDF

Analysis of Hydrodynamics in a Directly-Irradiated Fluidized Bed Solar Receiver Using CPFD Simulation (CPFD를 이용한 태양열 유동층 흡열기의 수력학적 특성 해석)

  • Kim, Suyoung;Won, Geunhye;Lee, Min Ji;Kim, Sung Won
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.535-543
    • /
    • 2022
  • A CPFD (Computational particle fluid dynamics) model of solar fluidized bed receiver of silicon carbide (SiC: average dp=123 ㎛) particles was established, and the model was verified by comparing the simulation and experimental results to analyze the effect of particle behavior on the performance of the receiver. The relationship between the heat-absorbing performance and the particles behavior in the receiver was analyzed by simulating their behavior near bed surface, which is difficult to access experimentally. The CPFD simulation results showed good agreement with the experimental values on the solids holdup and its standard deviation under experimental condition in bed and freeboard regions. The local solid holdups near the bed surface, where particles primarily absorb solar heat energy and transfer it to the inside of the bed, showed a non-uniform distribution with a relatively low value at the center related with the bubble behavior in the bed. The local solid holdup increased the axial and radial non-uniformity in the freeboard region with the gas velocity, which explains well that the increase in the RSD (Relative standard deviation) of pressure drop across the freeboard region is responsible for the loss of solar energy reflected by the entrained particles in the particle receiver. The simulation results of local gas and particle velocities with gas velocity confirmed that the local particle behavior in the fluidized bed are closely related to the bubble behavior characterized by the properties of the Geldart B particles. The temperature difference of the fluidizing gas passing through the receiver per irradiance (∆T/IDNI) was highly correlated with the RSD of the pressure drop across the bed surface and the freeboard regions. The CPFD simulation results can be used to improve the performance of the particle receiver through local particle behavior analysis.