• Title/Summary/Keyword: Non-standard difference method

Search Result 123, Processing Time 0.031 seconds

The Influence of Field Compaction Method on the Efficiency of Compaction and the C. B. R. Value (전압방법(轉壓方法)이 전압효과((轉壓效果) 및 C. B. R. 값에 미치는 영향(影響))

  • Chung, Sang;Kang, Yea Mook
    • Korean Journal of Agricultural Science
    • /
    • v.10 no.2
    • /
    • pp.292-309
    • /
    • 1983
  • This study is intended to find out the degree of compaction in field compaction, with soil type, the thickness of soil layer and the number of roller passing through the field density test and the field C. B. R. test by comparing vibration and non-vibration compactions. The results in this study are summarized as follows. 1. When the number of roller passing is few, it shows that the efficiency of the compaction by vibratory compaction is greater than that by non-vibratory compaction, the difference of the compaction ratio between vibratory and non-vibratory compaction is decreased according as the number of roller passing is more frequent. 2. Mechanizing on a large scale it is possible for a large equipment to be able to reach the point of A-1 compact ion method with three to five times of roller passing. To provide for mechanizing on a larger scale it is advisable to fix the standard by the D-2 compaction method. 3. As dry-density increases, the C. B. R. value increases, but the increasing ratio of C. B. R. value showed greater in vibrating compacting. 4. According as the number of roller passing increases, the increasing tendency of the C. B. R. Value is slow and the difference of the C. B. R. value between vibration and non-vibration compaction is large, the C. B. R. value showed greater about 20% in vibration compaction than in non-vibration compaction. 5. In C-5 soil type, with increasing the thickness of compaction, the degree of compaction is decreased. When the thickness of compaction is increased from 20cm to 30cm, the degree of compaction is decreased slowly, while the thickness of the compaction is increased from 30cm to 40cm the degree of compaction is decreased remarkably. Therefore it is advisable to compact the ground under the thickness of 30cm.

  • PDF

The effects of noise reduction, sharpening, enhancement, and image magnification on diagnostic accuracy of a photostimulable phosphor system in the detection of non-cavitated approximal dental caries

  • Kajan, Zahra Dalili;Davalloo, Reza Tayefeh;Tavangar, Mayam;Valizade, Fatemeh
    • Imaging Science in Dentistry
    • /
    • v.45 no.2
    • /
    • pp.81-87
    • /
    • 2015
  • Purpose: Contrast, sharpness, enhancement, and density can be changed in digital systems. The important question is to what extent the changes in these variables affect the accuracy of caries detection. Materials and Methods: Forty eight extracted human posterior teeth with healthy or proximal caries surfaces were imaged using a photostimulable phosphor (PSP) sensor. All original images were processed using a six-step method: (1) applying "Sharpening 2" and "Noise Reduction" processing options to the original images; (2) applying the "Magnification 1:3" option to the image obtained in the first step; (3) enhancing the original images by using the "Diagonal/"option; (4) reviewing the changes brought about by the third step of image processing and then, applying "Magnification 1:3"; (5) applying "Sharpening UM" to the original images; and (6) analyzing the changes brought about by the fifth step of image processing, and finally, applying "Magnification 1:3." Three observers evaluated the images. The tooth sections were evaluated histologically as the gold standard. The diagnostic accuracy of the observers was compared using a chi-squared test. Results: The accuracy levels irrespective of the image processing method ranged from weak (18.8%) to intermediate (54.2%), but the highest accuracy was achieved at the sixth image processing step. The overall diagnostic accuracy level showed a statistically significant difference (p=0.0001). Conclusion: This study shows that the application of "Sharpening UM" along with the "Magnification 1:3" processing option improved the diagnostic accuracy and the observer agreement more effectively than the other processing procedures.

Noncontact Sleep Efficiency and Stage Estimation for Sleep Apnea Patients Using an Ultra-Wideband Radar (UWB 레이더를 사용한 수면무호흡환자에 대한 비접촉방식 수면효율 및 수면 단계 추정)

  • Park, Sang-Bae;Kim, Jung-Ha
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.3
    • /
    • pp.433-444
    • /
    • 2020
  • This study proposes a method to improve the sleep stage and efficiency estimation of sleep apnea patients using a UWB (Ultra-Wideband) radar. Motion and respiration extracted from the radar signal were used. Respiratory signal disturbances by motion artifacts and irregular respiration patterns of sleep apnea patients are compensated for in the preprocessing stage. Preprocessing calculates the standard deviation of the respiration signal for a shift window of 15 seconds to estimate thresholds for compensation and applies it to the breathing signal. The method for estimating the sleep stage is based on the difference in amplitude of two kinds of smoothed respirations signals. In smoothing, the window size is set to 10 seconds and 34 seconds, respectively. The estimated feature was processed by the k-nearest neighbor classifier and the feature filtering model to discriminate between the sleep periods of the rapid eye movement (REM) and non-rapid eye movement (NREM). The feature filtering model reflects the characteristics of the REM sleep that occur continuously and the characteristics that mainly occur in the latter part of this stage. The sleep efficiency is estimated by using the sleep onset time and motion events. Sleep onset time uses estimated features from the gradient changes of the breathing signal. A motion event was applied based on the estimated energy change in the UWB signal. Sleep efficiency and sleep stage accuracy were assessed with polysomnography. The average sleep efficiency and sleep stage accuracy were estimated respectively to be about 96.3% and 88.8% in 18 sleep apnea subjects.

The Allocation Methods for Economical Efficiency Using an Optimized Model (최적화 모델을 이용한 경제적인 총량관리 할당기법 연구)

  • Choi, In Uk;Shin, Dong Seok;Kim, Hong Tae;Park, Jae Hong;Ahn, Ki Hong;Kim, Yong Seok
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.3
    • /
    • pp.295-303
    • /
    • 2015
  • In Korea, Total Maximum Daily Loads(TMDLs) has been enforced to restore and manage water quality in the watersheds. However, some assesment of implementation plan of TMDLs showed that the achievement of the target water quality is not related to the proper allocation loads because difference of flow duration interval. In the United States, the discharge loads are determined by water quality modeling considering standard flow conditions according to purpose. Therefore, this study tried to develop the allocation method considering economical efficiency using water quality model. For this purpose, several allocation methods being used in the management of TMDLs is investigated and develope an allocation criteria considering regional equality and uniformity. Since WARMF(Watershed Analysis Risk Management Framework) model can simulate the time varying behavior of a system and the various water quality variables, it was selected for a decision support system in this study. This model showed fairly good performance by adequately simulating observed discharge and water quality in Miho watershed. Furthermore, the scenario simulation results showed that the effect of annual average water quality improvement to remove 1kg BOD is more than 25 times, even if point pollutants treatment facility is six times more expensive to operate than non-point pollutants treatment facility.

The In-Core Fuel Management by Variational Method (변분법에 의한 노심 핵연료 관리)

  • Kyung-Eung Kim
    • Nuclear Engineering and Technology
    • /
    • v.16 no.4
    • /
    • pp.181-194
    • /
    • 1984
  • The in-core fuel management problem was studied by use of the calculus of variations. Two functions of interest to a public power utility, the profit function and the cost function, were subjected to the constraints of criticality, the reactor turnup equations and an inequality constraint on the maximum allowable power density. The variational solution of the initial profit rate demonstrated that there are two distinct regions of the reactor, a constant power region and a minimum inventory or flat thermal flux region. The transition point between these regions is dependent on the relative importance of the profit for generating power and the interest charges for the fuel. The fuel cycle cost function was then used to optimize a three equal volume region reactor with a constant fuel enrichment. The inequality constraint on the maximum allowable power density requires that the inequality become an equality constraint at some points in the reactor. and at all times throughout the core cycle. The finite difference equations for reactor criticality and fuel burnup in conjunction with the equality constraint on power density were solved, and the method of gradients was used to locate an optimum enrichment. The results of this calculation showed that standard non-linear optimization techniques can be used to optimize a reactor when the inequality constraints are properly applied.

  • PDF

Morphometric Characteristics and Fin Dimorphism between Male and Female on the Marine Medaka, Oryzias dancena

  • Im, Jae Hyun;Gil, Hyun Woo;Lee, Tae Ho;Kong, Hee Jeong;Ahn, Cheol Min;Kim, Bong Seok;Kim, Dong Soo;Zhang, Chang Ik;Park, In-Seok
    • Development and Reproduction
    • /
    • v.20 no.4
    • /
    • pp.331-347
    • /
    • 2016
  • Sexual dimorphism is the most conspicuous difference between the sexes. This study examines possible sexual dimorphism and the relative growth patterns of morphometric characteristics in the marine medaka, Oryzias dancena for their potential to help differentiate between males and females of this species. The von Bertalanffy growth parameters estimated by a non-linear regression method were $L_{\infty}=30.2mm$, K=3.22/year, and ${\tau}_0=-0.05$. All 18 characteristics measured showed a difference between males and females from 70 days after hatching. Each of these characteristics were significantly different between sexes (ANCOVA, P<0.05), and the ratio of standard length between sexes showed that males were larger than females for all five morphometric measurements. Fin length measurements were taken for 21 distances of anal fin and 7 distances of dorsal fin between landmarks. There were all differences for all dorsal fin rays between the males and the females and there is significant difference in 70 days after their hatch when the sexual dimorphism is presented. The significant difference (P<0.05) in fin ray for male and female was more greatly seen as they grow. Male marine medaka showed more rapid growth than females, with longer length, dorsal fins and anal fins. Differences in these characteristics will be useful during experiments when it is necessary to differentiate between sexes of marine medaka.

Effect of Whole Body Irradiation on Spontaneous Motility and Oxygen Consumption Rate of Mouse Isolated Duodenum and Its Response to Glucose and 5-hydrocytryptamine (X-선(線) 전신조사(全身照射)가 적출(摘出)마우스 십이지장(十二指腸)의 자동성운동(自動性運動) 및 산소(酸素) 소비량(消費量)에 미치는 영향(影響)과 Glucose 및 5-hydroxytryptamine 이 이들에 미치는 효과(效果))

  • Kwon, Yong-Ju;Choo, Young-Eun
    • The Korean Journal of Physiology
    • /
    • v.4 no.2
    • /
    • pp.45-51
    • /
    • 1970
  • In an attempt to better understand the effect of whole body irradiation on the spontaneous motility and oxygen consumption rate of the isolated mouse duodenum, a whole body X-irradiation of 1,000r. was given to albino mouse, and 1) the total length of contraction of isolated duodenum was recorded on kymograph every five minutes for 60 minutes, 2) glucose and 5-hydroxytryptamine(5-HT) were added to the reaction medium of Kreb's-Ringer-bicarbonate buffer(KRB) and response of the isolated duodenum to the drugs was observed, and 3) the oxygen consumption rate $(QO_2)$ of the isolated duodenum as well as the effect of glucose and 5-HT on $QO_2$ were measured by Warburg's standard manometric method and the comparison was made with the control(i.e. normal) group. The results thus obtained are summarized as follows. 1. The spontaneous motility of the isolated duodenum in the irradiated groups showed a significantly elevated pattern for the first 15 minutes comparing with the control. The motility, however, decreased after 15 minutes and remained so in the irradiated groups to the level of the nonirradiated control, but 24 hours post-irradiation group showed a tendency of an increased motility while one hour post-irradiation group showed no difference comparing with the control. 2. Addition of glucose produced generally elevated motility of the isolated duodenum in both irradiated and non-irradiated groups comparing with the control throughout the experiment, but no difference was observed in contractile amplitude between the irradiated and non·irradiated groups. 3. When 5-HT was added to the irradiated group, the contractile amplitude of isolated duodenum was similar to that of the control, and 5-HT alone caused a slight increase of the motility comparing with the control. 4. The oxygen consumption rate $(QO_2)$ of the isolated duodenum was found to be ,slightly increased in one hour post·irradiated group, but similar in 24 hour post·irradiated group comparing with the control. Glucose produced a significant increase of $QO_2$ in all the groups, but 5-HT produced a tendency of decrease of $QO_2$ in all the groups.

  • PDF

Discrimination of cows from heifers by antemortem and postmortem inspection in slaughter house (도축장의 생.해체검사를 통한 경산우 및 미경산우 감별법(I))

  • Choi, Im-Yong;Choi, Tae-Suk;Lee, Dal-Ju;Lee, Hae-Yeong;Rho, Chang-Sik;Kim, Kyu-Hiun;Kim, Eun;Kweon, Taek-Boo;Lee, Jung-Hark
    • Korean Journal of Veterinary Service
    • /
    • v.30 no.3
    • /
    • pp.429-436
    • /
    • 2007
  • This study was performed to make helpful standard for discrimination of cows from heifers by uterine and ovarian section inspection. A total of 3,736 heifers and 249 cows were inspected from January to November 2006 in Karak Market Slaughter house. Firstly, it was obvious that non-corpus albicans were observed in almost heifers(3,597/3,736, 96.3%), but there were distinctive corpus albicans in all cows (249/249 100%). Secondly, another evident was that the length and diameter of the horn in uterus was below 30mm in 94.5% (3,267/3,736) heifers, but above 30mm in 90.4% (225/245) cows, and it was easy to distinguish between right and left horn by difference of size in 87.6% (218/249) cows. Thirdly the diameters of pelvic cavity was below 220mm in 96.8% (3,615/3,736) heifers, but was over 200mm in 85.1% (212/249) cows. Fourthly another difference was found in second sacrum union condition and 13th thoracic vertebral process's states. In case of heifers, it was distinctive five lines in each second sacrum, but it was non-distinctive or united in the same each lines of the sacrum in cows. Fifthly in the results of 13th thoracic vertebral colors, the ratio between red color and white color was 7 : 3 in heifers (3,385/3,736, 90.6%), but that was 2 : 8 in cows (199/249, 79.9%). Consequently, it was possible to use the method which discriminated cows from heifers by uterine and ovarian section inspection in large scaled field slaughter house.

A Study on the Improvement of HACCP Evaluation Items in Small Scale Meat Packaging Plant (소규모 식육포장처리업 HACCP 평가항목 개선 연구)

  • Jung, Sung-Won;Cho, Seok-Hyun;Back, Seung-Hee;Kong, Hong-Sik;Nam, In-Sik
    • Korean Journal of Organic Agriculture
    • /
    • v.27 no.4
    • /
    • pp.437-452
    • /
    • 2019
  • The HACCP evaluation standards for the meat packaging plant are divided into general scale HACCP evaluation standard and small scale HACCP evaluation standard. There are 69 evaluation items in the general scale HACCP evaluation criteria, of which 54 items in the prerequisite management and 15 items in the HACCP management are included. The number of small scale HACCP evaluation items are 20 and about 29% of the general scale HACCP evaluation items. This may not be enough to produce a safety livestock products for the purpose of implementing the HACCP system due to the nature of the meat packaging plant, which does not show much difference in the production process or method of product depending on the scale. To improve the small scale HACCP evaluation standard, the importance of each item was compared with the small scale HACCP evaluation based on the rate of non-compliance and the severity levels in the general scale HACCP evaluation items. As a result of the study, 8 items were derived from the prerequisites management, 2 items were derived from the HACCP management, and some similar evaluation items were grouped together. Finally, 10 items were added to the 20 items of the existing small scale HACCP evaluation items. In this study, study on the safety management of domestic livestock products are continuously carried out, so that it is possible to provide safety livestock products to consumers and contributes to securing competitiveness of domestic livestock industry.

The characteristics on dose distribution of a large field (넓은 광자선 조사면($40{\times}40cm^2$ 이상)의 선량분포 특성)

  • Lee Sang Rok;Jeong Deok Yang;Lee Byoung Koo;Kwon Young Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.19-27
    • /
    • 2003
  • I. Purpose In special cases of Total Body Irradiation(TBI), Half Body Irradiation(HBI), Non-Hodgkin's lymphoma, E-Wing's sarcoma, lymphosarcoma and neuroblastoma a large field can be used clinically. The dose distribution of a large field can use the measurement result which gets from dose distribution of a small field (standard SSD 100cm, size of field under $40{\times}40cm2$) in the substitution which always measures in practice and it will be able to calibrate. With only the method of simple calculation, it is difficult to know the dose and its uniformity of actual body region by various factor of scatter radiation. II. Method & Materials In this study, using Multidata Water Phantom from standard SSD 100cm according to the size change of field, it measures the basic parameter (PDD,TMR,Output,Sc,Sp) From SSD 180cm (phantom is to the bottom vertically) according to increasing of a field, it measures a basic parameter. From SSD 350cm (phantom is to the surface of a wall, using small water phantom. which includes mylar capable of horizontal beam's measurement) it measured with the same method and compared with each other. III. Results & Conclusion In comparison with the standard dose data, parameter which measures between SSD 180cm and 350cm, it turned out there was little difference. The error range is not up to extent of the experimental error. In order to get the accurate data, it dose measures from anthropomorphous phantom or for this objective the dose measurement which is the possibility of getting the absolute value which uses the unlimited phantom that is devised especially is demanded. Additionally, it needs to consider ionization chamber use of small volume and stem effect of cable by a large field.

  • PDF