• Title/Summary/Keyword: Non-standard difference method

Search Result 122, Processing Time 0.031 seconds

Feasibility of Using the Clamp Meter in Measuring X-Ray Tube Current

  • Kim, Sung-Chul
    • International Journal of Contents
    • /
    • v.9 no.1
    • /
    • pp.38-41
    • /
    • 2013
  • The clamp meter maintains electric safety as a non-invasive method while measuring the absolute value of tube current with it has been recently developed for an X-ray high-tension cable. Especially this can show high accuracy at short X-ray exposure time. Considering such a condition, this study is to evaluate the feasibility of a clamp meter in measuring X-ray tube current by taking the measurements and comparing with those of the Dynalyzer III which has been considered as a standard measuring device. From measuring the tube current accuracy depending on changes in tube voltage and exposure time, the clamp meter showed higher accuracy rate which was -1.3~4.2% difference. Thus clamp meter can be used for clinical radiologists who are not familiar electric circuit to manage X-ray devices easily and correctly in the future.

Icing Recovery Method Effect on Blood Lactate and Heart Rate after Sports Climbing

  • KIM, Myung Gyun;LEE, Dong Geun;MOON, Hwang Woon
    • Journal of Sport and Applied Science
    • /
    • v.4 no.1
    • /
    • pp.9-14
    • /
    • 2020
  • The purpose of this study is to investigate the effect of ICING recovery method after sports climbing to blood lactate concentration and heart rate. The subjects were 12 male 20s undergraduate students (ICING group of 6, Control group of 6). Blood lactate concentration and heart rate were measured before climbing, after climbing, 5-minute recovery and 10minute recovery. Heart rate were also measured during the climbing. The subjects performed climbing 3 times. Data were analysed by SPSS 20.0. To compare blood lactate concentration and heart rate among groups, the independent samples t-test was employed using an alpha level of .05. Mean and standard deviations were computed. Results show that there is no significant difference between the icing group and non-icing group. Yet, the differences of blood lactate concentration were observed between groups. Blood lactate concentration of icing group was significantly higher than non-icing group in the condition of 1st climbing. Blood lactate concentration of non-icing group was significantly higher than icing group in 2nd 10-minute recovery. ICING recovery method is shown to be not significantly effective to blood lactate concentration and heart rate. This could be comprehended that long-term high-intensity (70% of 1RM) exercise can be prepared for the further research.

Investigation of Standard Error Range of Non-Contact Thermometer by Environment (외부 환경 변화에 의한 비 접촉 체온계의 오차 범위 측정)

  • Kim, Jeongeun;Park, Sangwoong;Choi, Heakyung
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.4
    • /
    • pp.307-321
    • /
    • 2020
  • Purpose : A person infected by SARS-CoV2 may present various symptoms such as fever, pain in lower respiratory tract, and pneumonia. Measuring body temperature is a simple method to screen patients. However, changes in the surrounding environment may cause errors in infrared measurement. Hence, a non-contact thermometer controls this error by setting a correction value, but it is difficult to correct it for all environments. Therefore, we investigate device error values according to changes in the surrounding environment (temperature and humidity) and propose guidelines for reliable patient detection. Methods : For this study, the temperature was measured using three types of non-contact thermometers. For accurate temperature measurement, we used a water bath kept at a constant temperature. During temperature measurement, we ensured that the temperature and humidity were maintained using a thermo-hygrometer. The conditions of the surrounding environment were changed by an air conditioner, humidifier, warmer, and dehumidifier. Results : The temperature of the water bath was measured using a non-contact thermometer kept at various distances ranging from 3~10 cm. The value measured by the non-contact thermometer was then verified using a mercury thermometer, and the difference between the measured temperatures was compared. It was observed that at normal surrounding temperature (24 ℃), there was no difference between the values when the non-contact thermometer was kept at 3 cm. However, as the distance of the non-contact thermometer was increased from the water bath, the recorded temperature was significantly different compared with that of mercury thermometer. Moreover, temperature measurements were conducted at different surrounding temperatures and the results obtained significantly varied from when the thermometer was kept at 3 cm. Additionally, it was observed that the effect on temperature decreases with an increase in humidity Conclusion : In conclusion, non-contact thermometers are lower in lower temperature and dry weather in winter.

Damage identification for high-speed railway truss arch bridge using fuzzy clustering analysis

  • Cao, Bao-Ya;Ding, You-Liang;Zhao, Han-Wei;Song, Yong-Sheng
    • Structural Monitoring and Maintenance
    • /
    • v.3 no.4
    • /
    • pp.315-333
    • /
    • 2016
  • This study aims to perform damage identification for Da-Sheng-Guan (DSG) high-speed railway truss arch bridge using fuzzy clustering analysis. Firstly, structural health monitoring (SHM) system is established for the DSG Bridge. Long-term field monitoring strain data in 8 different cases caused by high-speed trains are taken as classification reference for other unknown cases. And finite element model (FEM) of DSG Bridge is established to simulate damage cases of the bridge. Then, effectiveness of one fuzzy clustering analysis method named transitive closure method and FEM results are verified using the monitoring strain data. Three standardization methods at the first step of fuzzy clustering transitive closure method are compared: extreme difference method, maximum method and non-standard method. At last, the fuzzy clustering method is taken to identify damage with different degrees and different locations. The results show that: non-standard method is the best for the data with the same dimension at the first step of fuzzy clustering analysis. Clustering result is the best when 8 carriage and 16 carriage train in the same line are in a category. For DSG Bridge, the damage is identified when the strain mode change caused by damage is more significant than it caused by different carriages. The corresponding critical damage degree called damage threshold varies with damage location and reduces with the increase of damage locations.

On-Site Evaluation Technique of Linearity for Ratio Error and Phase Angle Error of Current Transformer Comparison Measurement Equipment (전류변성기 비교 측정 장치의 비오차 및 위상각 오차의 직선성 현장 평가기술)

  • Jung, Jae-Kap;Kwon, Sung-Won;Lee, Sang-Hwa;Kang, Jeon-Hong;Kim, Myung-Soo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.6
    • /
    • pp.313-316
    • /
    • 2006
  • A method for evaluation of the linearity of both the ratio error and phase angle error in the current transformer(CT) comparison measurement equipment has been developed by employing the standard resistors with negligible AC-DC resistance difference less than $10^{-5}$. The non-reactive standard resistors for the linearity check of the system are used as the external burden connected with the secondary of CT under test. These burdens consist of nine standard resistors, with the nominal resistance of $0.01{\Omega},\;0.1{\Omega},\;0.2{\Omega},\;0.4{\Omega},\;0.6{\Omega},\;1{\Omega},\;2{\Omega},\;4{\Omega}$, and $10{\Omega}$. For linearity check, the developed method has been applied in the CT comparison measurement equipment belonging to the industry.

Usefulness of Panoramic Radiography in the Detection of Maxillary Sinus Pathosis (상악동 병변의 인지시 파노라마 방사선사진의 유용성)

  • Lee Eun-Sook;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.223-239
    • /
    • 1999
  • Purpose: to evaluate the usefulness of the panoramic radiography, generally used in dental clinic, for the detection of the maxillary sinus pathosis due to the inflammation and tumor, through the comparison with CT findings as the absolute standard. Materials & Methods: 150 maxillary sinuses of 75 patients with or without particular signs and symptoms and showing soft tissue lesions or destruction of maxillary sinus walls in at least one sinus in CT, were selected as subject samples, and the panoramic radiography of the same patients were interpretated by 3 dental radiologists and 3 non dental radiologist given no previous informations. Using the CT findings as the absolute standard, the diagnostic ability of panoraimc radiography in the mucosal thickening, maxillary sinus haziness, inferior wall destruction, medial wall destruction, posterolateral wall destruction and the superior wall destruction was evaluated using the ROC curve and the difference between dental radiologist group and non dental radiologist group was also evaluated. Results: 1. When dental radiologist group interpretated the destruction of inferior wall and posterolateral wall, the kappa value which shows interobserver's coincidence was above 0.75. 2. The diagnostic ability according to site of interpretation was the highest when the inferior wall was interpretated in both observer groups and there was a statistically significant difference between the dental radiologist group and non dental radiologist group in interpretating the mucosal thickening, haziness, destruction of the inferior and medial wall(p<0.05). 3. The diagnostic ability in detecting the destruction of the sinus walls was better than in soft tissue lesions in both groups and between the groups there was a statistically significant difference(p<0.05). Conclusion: When detecting the destruction of inferior and posterolateral wall of the maxillary sinus there was coincident with that of CT findings, and so it is considered that diagnostic ability of panoramic radiography is high in this point. But in interpretating the destruction of medial wall and soft tissue lesions, diagnostic ability of the panoramic radiography was relatively low and there was a significant difference between the dental radiologist group and non dental radiologist group. Therefore CT or other auxiliary diagnostic method will be necessary when evaluating thorough pathosis of maxillary sinus objectively.

  • PDF

Estimation of Denominators- a New Approach for Calculating of Various Rates in Cancer Registries

  • Haroon, A.S.;Gupta, S.M.;Tyagi, B.B.;Farhat, J.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.7
    • /
    • pp.3229-3232
    • /
    • 2012
  • In this study, cancer incidence data were assessed to provide various rates of five year age groups for a given year, lying between two census years. The individual exponential growth rate method is most useful in both population-based and non-population cased cancer registries in India to estimate the population by five yearly age groups and also find the rates of crude rates, age standard rates and cumulative rates. This method has been shown to endure from bias and often results sacrificing the overall growth rate and correction factor must be needful in five year age group population to maintain it. A second method, the difference distribution method is also able to maintain the overall growth rate and overcome the bias in estimation of five yearly age group populations. From this point of view these methods serving a new technique for population estimation by five yearly age groups for inter census years.

The Development of the Components of the Length Measurement Concept in the Procedure of Measurement Using a Ruler

  • Antic, Milica D.;Dokic, Olivera J.
    • Research in Mathematical Education
    • /
    • v.22 no.4
    • /
    • pp.261-282
    • /
    • 2019
  • The research related to testing pupils' achievement in the field of Measurement and Measure in initial teaching of geometry points to an insufficient adoption of the basic components of the length measurement concept among pupils. In order to discover the cause, we looked at the basic components on which the procedure of measuring length using a ruler is based, highlighted the possibilities of introducing the procedure in measuring length, and determined pupils' achievement during the procedure of measuring length using a ruler. The research sample consisted of 145 pupils, out of which 72 were the 2nd grade pupils and 73 were the 4th grade pupils. A descriptive method was applied in the research. The technique we used was testing, and for the statistical data processing we used a χ2 test. The results of the research show that, when drawing a straight line of a given length using a ruler, there is no statistical difference in achievement between the 2nd and 4th grade pupils, nor in the pupils' knowledge regarding drawing a ruler independently, while drawing a straight line of a given length using a "broken" ruler 4th grade pupils are statistically better. The results of the research indicate that pupils' achievement is better in doing standard tasks than in non-standard ones, given that the latter require conceptual knowledge. The components of the concept of length measurement using ruler have not been sufficiently developed yet, and these include: zero-point, partitioning a measured object in a series of consecutive measurement units and their iteration. We shed more light on the critical stage in the procedure of length measurement - the transition from non-standard to standard units and the formation of the length measurement scale. For further research, we propose to look at the formation of the concept of length measurement using the ruler through all its components and their inclusion in the mathematics curriculum, as well as examining the correlation of pupils' achievement in the procedure of measuring length with their achievement in measuring area (and volume).

Assessment of vitamin $B_6$ status in Korean patients with newly diagnosed type 2 diabetes

  • Ahn, Hee-Jung;Min, Kyung-Wan;Cho, Youn-Ok
    • Nutrition Research and Practice
    • /
    • v.5 no.1
    • /
    • pp.34-39
    • /
    • 2011
  • The purpose of this study was to assess vitamin $B_6$ intake and status in Korean patients with newly diagnosed type 2 diabetes. Sixty-four patients with newly diagnosed type 2 diabetes and 8-11% glycated hemoglobin (A1C), along with 28 age-matched non-diabetic subjects, participated. Dietary vitamin $B_6$ intake was estimated by the 24 hour recall method and plasma pyridoxal 5'-phosphate (PLP) was measured. There was a significant difference in daily total calorie intake between the diabetic and non-diabetic groups ($1,917{\pm}376$ vs $2,093{\pm}311\;kcal$). There were no differences in intake of total vitamin $B_6$ ($2.51{\pm}0.91$ vs $2.53{\pm}0.81\;mg/d$) or vitamin $B_6$/1,000 kcal ($1.31{\pm}0.42$ vs $1.20{\pm}0.32\;mg$) between the diabetic and non-diabetic groups, and I intakes of total vitamin $B_6$ were above the Korean RDA in both groups ($180.0{\pm}57.9$ vs $179.0{\pm}65.4$). There was a higher percentage of diabetic subjects whose plasma PLP concentration was < 30 nmol/L compared to non-diabetic group. Plasma PLP levels tended to be lower in the diabetic subjects than in the non-diabetic subjects, although the difference was not statistically significant due to a large standard deviation ($80.0{\pm}61.2\;nmol/L$ vs $68.2{\pm}38.5\;nmol/L$). Nevertheless, plasma PLP levels should be monitored in pre-diabetic patients with diabetic risk factors as well as in newly diagnosed diabetic patients for long-term management of diabetes, even though this factor is not a major risk factor that contributes to the development of degenerative complications in certain patients.

Proteomic Analysis of Bovine Pregnancy-specific Serum Proteins by 2D Fluorescence Difference Gel Electrophoresis

  • Lee, Jae Eun;Lee, Jae Young;Kim, Hong Rye;Shin, Hyun Young;Lin, Tao;Jin, Dong Il
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.28 no.6
    • /
    • pp.788-795
    • /
    • 2015
  • Two dimensional-fluorescence difference gel electrophoresis (2D DIGE) is an emerging technique for comparative proteomics, which improves the reproducibility and reliability of differential protein expression analysis between samples. The purpose of this study was to investigate bovine pregnancy-specific proteins in the proteome between bovine pregnant and non-pregnant serum using DIGE technique. Serums of 2 pregnant Holstein dairy cattle at day 21 after artificial insemination and those of 2 non-pregnant were used in this study. The pre-electrophoretic labeling of pregnant and non-pregnant serum proteins were mixed with Cy3 and Cy5 fluorescent dyes, respectively, and an internal standard was labeled with Cy2. Labeled proteins with Cy2, Cy3, and Cy5 were separated together in a single gel, and then were detected by fluorescence image analyzer. The 2D DIGE method using fluorescence CyDye DIGE flour had higher sensitivity than conventional 2D gel electrophoresis, and showed reproducible results. Approximately 1,500 protein spots were detected by 2D DIGE. Several proteins showed a more than 1.5-fold up and down regulation between non-pregnant and pregnant serum proteins. The differentially expressed proteins were identified by MALDI-TOF mass spectrometer. A total 16 protein spots were detected to regulate differentially in the pregnant serum, among which 7 spots were up-regulated proteins such as conglutinin precursor, modified bovine fibrinogen and IgG1, and 6 spots were down-regulated proteins such as hemoglobin, complement component 3, bovine fibrinogen and IgG2a three spots were not identified. The identified proteins demonstrate that early pregnant bovine serum may have several pregnancy-specific proteins, and these could be a valuable information for the development of pregnancy-diagnostic markers in early pregnancy bovine serum.