• Title/Summary/Keyword: Non-standard Condition

Search Result 215, Processing Time 0.027 seconds

A Development of Test Method on the Energy Consumption Efficiency of Domestic Gas Boiler below 70 kW (70 kW 이하 가정용 가스보일러 에너지소비효율 실험방법 개발)

  • Park, Chanil;Kim, Laehyun
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.73-82
    • /
    • 2016
  • The energy consumption efficiency in a variety of operational test mode was considered for domestic gas boiler below 70 kW. The energy efficiency test carried out in the experimental conditions similar to the actual operation status was analyzed and compared with the current Korean efficiency test method. Four types of test modes for each boiler(Non-condensing and condensing boiler) were carried out in the condition of laboratory mode(full load, steady state) and actual operating mode. Futhermore divided into two operational status for each of these, it was applied by maximum gas consumption and consumer sales conditions. Test equipment has the function referred to gas boiler standards, such as KS or European standard EN. The equipment should be continuously measured and record the measuring factors which are the flow volume of gas and water, laboratory temperature, water flow volume for heating, return water volume after heating and quantity of the exhaust gases(CO, NO, $NO_2$). The experimental results were found that non-condensing boiler efficiency of laboratory mode is about 10% higher than that of actual mode. In case of condensing boiler, the efficiency of laboratory condition is about 20% higher than that of the actual using conditions. I suggest that the government will gradually take the efficiency test method considering the actual conditions.

A Study on Creep Effect of Synthetic Fiber Rope Mooring System on Motion Response of Vessel and Tension of Mooring Line (섬유로프 계류시스템의 크리프 효과가 부유체의 운동응답 및 계류선의 장력 변화에 미치는 영향에 관한 연구)

  • Park, Sung Min;Lee, Seung Jae;Kang, Soo Won
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.2
    • /
    • pp.151-160
    • /
    • 2017
  • Growing demand and rapid development of the synthetic fiber rope in mooring system have taken place since it has been used in deep water platform lately. Unlike a chain mooring, synthetic fiber rope composed of lightweight materials such as Polyester(polyethylene terephthalate), HMPE(high modulus polyethylene) and Aramid(aromatic polyamide). Non-linear stiffness and another failure mode are distinct characteristics of synthetic fiber rope when compared to mooring chain. When these ropes are exposed to environmental load for a long time, the length of rope will be increased permanently. This is called 'the creep phenomenon'. Due to the phenomenon, The initial characteristics of mooring systems would be changed because the length and stiffness of the rope have been changed as time goes on. The changed characteristics of fiber rope cause different mooring tension and vessel offset compared to the initial design condition. Commercial mooring analysis software that widely used in industries is unable to take into account this phenomenon automatically. Even though the American Petroleum Institute (API) or other classification rules present some standard or criteria with respect to length and stiffness of a mooring line, simulation guide considers the mechanical properties that is not mentioned in such rules. In this paper, the effect of creep phenomenon in the fiber rope mooring system under specific environment condition is investigated. Desiged mooring system for a Mobile Offshore Drilling Unit(MODU) with HMPE rope which has the highest creep is analyzed in a time domain in order to investigate the effects creep phenomenon to vessel offset and mooring tension. We have developed a new procedure to an analysis of mooring system reflecting the creep phenomenon and it is validated through a time domain simulation using non-linear mooring analysis software, OrcaFlex. The result shows that the creep phenomenon should be considered in analysis procedure because it affects the length and stiffness of synthetic fiber rope in case of high water temperature and permanent mooring system.

Design of an Improved Anti-Collision Unit for an RFID Reader System Based on Gen2 (Gen2 리더 시스템의 개선된 충돌방지 유닛 설계)

  • Sim, Jae-Hee;Lee, Yong-Joo;Lee, Yong-Surk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.2A
    • /
    • pp.177-183
    • /
    • 2009
  • In this paper, we propose an improved anti-collision algorithm. We have designed an anti-collision unit using this algorithm for the 18000-6 Type C Class 1 Generation 2 standard (Gen2). The Gen2 standard uses a Q-algorithm for incremental method on the Dynamic Slot-Aloha algorithm. It has basically enhanced performance over the Slot-Aloha algorithm. Unfortunately, there are several non-clarified parts: initial $Q_{fp}$ value, weighted C, and the ending point of the algorithm. If an incorrect value is selected, it causes degradation in performance. Thus we propose an improved anti-collision algorithm by clearly defining the vague parts of the existing algorithm. Simulation results showed an improved performance of up to 34.8% using an optimized value of C and the initial $Q_{fp}$ value. With the ending condition, performance is 34.7%. The anti-collision unit is designed using the Verilog HDL. The module was synthesized using Synopsys' Design Compiler and the TSMC $0.2{\mu}m$ standard cell library. The synthesized result yielded 3,847 gates, and was guaranteed under the proposed working frequency of 19.2MHz.

DEVELOPMENT OF THREE DIMENSIONAL MEASURING PROGRAM WITH FRONTAL AND LATERAL CEPHALOMETRIC RADIOGRAPHS -PART 1. COMPUTATION OF THE THREE-DIMENSIONAL COORDINATES BY COMPENSATION OF THE ERROR OF THE HEAD POSITION IN ORDINARY NON-BIPLANAR CEPHALOSTAT- (정모 및 측모 두부 방사선 규격사진을 이용한 3차원 계측 프로그램의 개발 -1. 단일 방사선원으로 촬영된 두부 방사선사진의 두부 위치 보정을 이용한 3차원 좌표의 산출-)

  • Lee, Geun-Ho;Lee, Sang-Han;Jang, Hyon-Joong;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.3
    • /
    • pp.214-220
    • /
    • 2001
  • The clinical application of the three-dimensional radiographic technique had been limited to standard Broadbent-Bolton cephalometer with biplanar stereoradiography. We developed a new method for compensating the error of head position in ordinary non-biplanar cephalostat. It became to possible to use the three dimensional cephalogram commonly in clinical bases. 1. The method of methemetical compensation of head positioning error in non-biplanar condition was evaluated with dry skull. The error of the method of first and the second trial was $0.46{\pm}1.21$, $0.33{\pm}0.90mm$, which means the error of the head positioning correction in conventional cephalogram was within clinical acceptance. 2. The reproducibility of this system for clinical application was 0.54 mm ($-2.99{\sim}2.26mm$) which defines the absolute mean difference of the first and second trial. Compare to the The landmark identification error $1.2{\pm}1.6mm$, the error of the measurement was within the range of landmark identification error. The result indicates the adequate clinical accuracy of the computation of three-dimensional coordinates by compensation of the error of the head position in ordinary non-biplanar cephalostat.

  • PDF

Characteristics of Sewage Flow in Sewer Pipes Deposited with Cohesive and Non-cohesive Solids (점착성 및 비점착성 고형물이 퇴적된 관로 내 하수흐름의 특성 조사)

  • Lee, Taehoon;Kang, Byongjun;Park, Kyoohong
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.7
    • /
    • pp.153-159
    • /
    • 2020
  • In order to find out the condition of flow in sewer pipes, this study investigated the characteristics of tractive force of sewage flow estimated using actual measured values of water level, velocity, and flowrate in sewers located at uppermost portion in a treatment area during dry weather periods. When the scene of sewage flow was taken by CCTV after cohesive and non-cohesive solids (tofu and sand) were put on the sewer invert, it was found that the solids could be flushed without significant interruption. In sewer with slope of 0.00319, the frequency exceeding the minimum tractive force of sewage during a weekday was zero, while it was 10 per day with slope of 0.00603. During the week of the field observation, the event to exceed the minimum tractive force occurred once, suggesting that sewer odor would potentially increase. Maximum tractive force in sewer with steep slope was 2.9-3.1 N/㎡, but with gentle slope it decreased to 1.6-1.7N/㎡. It was also observed that the interval of time maintained below the criterion of minimum tractive force increased, during weekends compared to weekdays and for the sewage including non-cohesive particles which could enter combined sewers during a storm period. This study found that the sewer sediments formed by direct feces input into sewers, through sewer pipes which were designed meeting the standard sewer design criteria, could be flushed without staying as deposited solids state for a long time.

A Comparative Analysis According to a Presence or Absence of Metal Artifacts when a Dose Change and QAC Technique are Applied in PET/CT Tests (PET/CT 검사에서 선량변화와 QAC기법 적용 시 Metal Artifact 유무에 따른 SUV 비교분석)

  • Yun, Sun-Hee;Kim, Yang-Jung;Kang, Young-Jik;Park, Su-Young;Kim, Ho-Sin;Ryu, Hyoung-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.51-56
    • /
    • 2015
  • Purpose As medical radiation exposures on patients are being social issues an interest in a relief of radiation exposures on patients is increasing. Further, there are many cases where some patients among who are getting PET/CT tests choose to get implanted with metal artifacts in their bodies. This study is to find out effects of presence or absence of metal artifacts when dose change or CT attenuation correction for the relief of radiation exposures are applied using phantoms through changes in standard uptake value (SUV). Materials and Methods GE company's Discovery 710 machine was used for PET/CT test equipments. We used NEMA IEC body phantoms. We also used screw and mesh cage made of titanium which are used in real clinical processes for the metal artifacts. Two experiments were conducted: One is to test and measure repeatedly about SUV about differences in CT attenuation corrections according to dose changes and another is to do the same procedure for SUV about the presence and absence of the metal artifacts. We injected $^{18}F-FDG$ into NEMA IEC body phantoms with a TBR ratio of 4:1 and then put the metal material into the transformation phantoms. Once a scanning for the metal artifacts was done we eliminated the metal artifacts and went on non-metal artifacts. For the each two experiments, we scanned repeatedly with CT kVp (140, 120, 100, 80) and mA (120, 80, 40, 20, 10) for an experimental condition. For PET, we reconstructed each with standard AC (STD) technique and quantitation achieved cnsistently QAC) technique among CT attenuation correction methods. We conducted a comparative analysis on measured average values and variations which were measured through repeated measure of SUV of region 1, 2, 3 spheres for each conditions of non-metal /metal scan. Results For each kVp, 120, 80, 40 (mA) of non/metal (screw, mesh cage) showed low frequency of fluctuation rates of above 2%. In 20, 10 mA above 2% of fluctuation rates appeared in high frequency. Also, when we compared the fluctuation rates of STD and QAC techniques in non/metal (screw, mesh cage) tests QAC technique showed about 1-10% of differences for each conditions compared to STD technique. In addition, metal types did not have significant effects on fluctuation rates. Conclusion We confirmed that SUV fluctuation rates for both STD and QAC techniques increase as dosage is lower. We also found that the SUV of PET data was maintained steadily in a low dosage for QAC technique when compared with STD technique. Hence, when the low dosage is used for the relief of radiation exposures on patients QAC technique may be exploited helpfully and this could be applied in the same way for patients with metal artifacts implanted in their bodies.

  • PDF

Strength and Deformation Characteristics on Stabilized Pavement Geomaterials (II) : Numerical Analysis (안정처리된 도로하부 지반재료의 강도 및 변형특성 (II) : 수치해석)

  • Park, Seong-Wan;Ji, Jong-Keun
    • International Journal of Highway Engineering
    • /
    • v.11 no.2
    • /
    • pp.205-216
    • /
    • 2009
  • As a subsequent study, this paper presents a comparative evaluation of structural responses in asphalt pavements with stabilized foundations. The approach based on a finite element analysis which incorporates non-linear behaviors of pavement geomaterials is used to estimate each performance indicator under standard single axle loading condition. In addition, results from laboratory tests are used to provide physical and mechanical properties of stabilized geomaterials for analyzing various pavement structures. Changes in pavement responses with varying layer thickness and stabilizer contents were investigated. It is found that the effect of layer thickness and stabilizer content is a critical factor in structural response of stabilized pavements. Moreover, a design criterion is proposed for selecting minimum contents of stabilizer of coarse-grained geomaterials based on a result of unconfined compressive strength and proper layer thickness of foundations.

  • PDF

Application Load Duration Curve for Evaluation of Impaired Watershed at TMDL Unit Watershed in Korea (수질오염총량 단위유역의 유량조건별 수체 손상 평가를 위한 부하지속곡선 적용성 연구)

  • Hwang, Ha-Sun;Yoon, Chun-Gyeong;Kim, Ji-Tae
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.6
    • /
    • pp.903-909
    • /
    • 2010
  • The purpose of this study was evaluated on the applicability of Load Duration Curve Method (LDC Method) using HSPF watershed model and sampling data for efficient TMDLs in Korea. The LDC Method was used for assessment pollutant characteristics in watershed and water quality variation in each water flow level. Load Duration Curve is applied for judge the level of impaired water-body and can be estimated the impaired level by pollutant, such as BOD, T-N, and T-P in this study depending on variation of stream flow. As a result, BOD, T-P was usually exceed the standard value at low flow and dry hydrologic period. Improvement of effluent concentration from WWTP and riparian buffer protection zone are effective to improve the water quality. T-N showed the worst condition at mid-range hydrologic period and moist hydrologic period. Therefore, soil erosion control program and BMPs for non-point source pollution control is effective for recovery the water quality, which can be useful method for management of water quality in the plan of recovery water quality spontaneously. Applicability of LDC Method was evaluated in the Nakbon A watershed. However, we need to consider more detailed and accumulated data set such as accurate GIS data and detail pollution data, and WWTP discharge water quality data for accurate evaluation of watershed. Overall, The LDC Method is adequate for evaluation of watersheds characteristics, and its application is recommended for watershed management and TMDL Implementation.

Application of Near Infrared Spectroscopy for Nondestructive Evaluation of Nitrogen Content in Ginseng

  • Lin, Gou-lin;Sohn, Mi-Ryeong;Kim, Eun-Ok;Kwon, Young-Kil;Cho, Rae-Kwang
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1528-1528
    • /
    • 2001
  • Ginseng cultivated in different country or growing condition has generally different components such as saponin and protein, and it relates to efficacy and action. Protein content assumes by nitrogen content in ginseng radix. Nitrogen content could be determined by chemical analysis such as kjeldahl or extraction methods. However, these methods require long analysis time and result environmental pollution and sample damage. In this work we investigated possibility of non-destructive determination of nitrogen content in ginseng radix using near-infrared spectroscopy. Ginseng radix, root of Panax ginseng C. A. Meyer, was studied. Total 120 samples were used in this study and it was consisted of 6 sample sets, 4, 5 and 6-year-old Korea ginseng and 7, 8 and 9-year-old China ginseng, respectively. Each sample set has 20 sample. Nigrogen content was measured by electronic analysis. NIR reflectance spectra were collected over the 1100 to 2500 nm spectral region with a InfraAlyzer 500C (Bran+Luebbe, Germany) equipped with a halogen lapmp and PbS detector and data were collected every 2 nm data point intervals. The calibration models were carried out by multiple linear regression (MLR) and partial least squares (PLS) analysis using IDAS and SESAME software. Result of electronic analysis, Korean ginseng were different mean value in nitrogen content of China ginseng. Ginseng tend to generally decrease the nitrogen content according as cultivation year is over 6 years. The MLR calibration model with 8 wavelengths using IDAS software accurately predicted nitrogen contents with correlation coefficient (R) and standard error of prediction of 0.985 and 0.855%, respectively. In case of SESAME software, the MLR calibration with 9 wavelength was selected the best calibration, R and SEP were 0.972 and 0.596%, respectively. The PLSR calibration model result in 0.969 of R and 0.630 of RMSEP. This study shows the NIR spectroscopy could be applied to determine the nitrogen content in ginseng radix with high accuracy.

  • PDF

The Behavior of Particulate-Bound logic Components and Their Relationships with Meteorological Parameters: Air-Sea Geochemistry of Inorganic and Organic tons in Cheiu Island (이온성분의 환경거동과 기상인자와의 관계: 제주지역을 중심으로 한 유.무기성 이온성분의 대기-해양지화학)

  • 김기현;이강웅
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.5
    • /
    • pp.479-490
    • /
    • 1998
  • The concentrations of ten inorganic (sodium, chloride, sulfate, ammonia, etc.) and three organic (acetate, formate, and MSA) ions associated with airborne particulate matter were measured from Cheju Island, Korea during the three field intensive campaigns conducted in (1) Sept./oct. 1997 (fall), (2) Dec. 1997 (winter), and (3) April 1998 (spring). The results of our measurements indicated that the concentration levels of most ionic species were decreasing significantly across the three experimental periods. The patterns of concentration reduction were clear as the sum of all cation and anion species changed dramatically across those periods such as 294> 144 > 65 and 193 >96>74 nequiv/m3, respectively. The changes were best explained in terms of the wind rose patterns of the study site. Since our sampling spot is located on the western-end point of Cheju Island, it is likely to reflect the effects of diverse sources such as natural, marine processes during NW and local non-maritime ones during SE winds. .Hence, the periodical changes in ionic concentrations may be accounted for by the comparable changes in wind direction. To further investigate environmental characteristics of these ionic components, correlation analysis was conducted not only between meteorological and ion data but between different ion-pairs. The results of these analyses confirm that the concentration levels of ionic species are strongly affected by wind speed and temperature and that there are certain patterns between ion species to which such effects apply. In light of the significance of the wind rose patterns in the area, we further extended these analyses into four data groups that were divided on the basis of wind direction. The results of these analyses showed that the strength of correlations between important pairs (e.g.:. between windspeed and most of major inorganic species including sodium and chloride) can be ranked on the distribution of major ions are very diverse, depending on data grouping scheme for such analysis. The results of this study thus suggest that environmental behavior of chemical components be analyzed in various respects, rather than simple standard, especially if measurements are made in complex environmental condition under which both natural and anthropogenic effects are competing each other.

  • PDF