• 제목/요약/키워드: Non-rigid fixation

검색결과 16건 처리시간 0.028초

골격성 III급 부정교합 환자의 악교정 수술 후 하악 과두의 위치 변화에 관한 연구 (THE CHANCES OF CONDYLAR POSITION AFTER ORTHOGNATHIC SURGERY IN PATIENTS WITH SKELETAL CLASS III MALOCCLUSION)

  • 윤형상;백형선
    • 대한치과교정학회지
    • /
    • 제22권4호
    • /
    • pp.837-853
    • /
    • 1992
  • The purpose of this study was to investigate the positional changes of the mandibular condyles after orthognathic surgery In patients with severe skeletal Class III malocclusion. This study was based on 21 patients who had received bilateral sagittal split osteotomy for mandibular setback. Among them 14 were fixated non - rigidly (W group), and 7 were fixated rigidly (R group). After submental vertex view analysis, each subject was given the T.M.J. Tomogram in both centric occlusion and centric relation immediate before, $4\~6$ weeks after and more than 6 months after surgery. The anteroposterior and vertical changes between each time interval were measured and analyzed statistically. Following results were obtained. 1. There was no significant difference between right and left condyles in their anteroposterior and vertical changes of the condylar position. 2. In anteroposterior changes of condylar position of the wire fixation group, the condyles were moved anteriorly 4-6 weeks after surgery, and then the pattern of reestablishment to their preoperative position was observed more than 6 months after surgery. In the rigid fixation group, there was no significant difference in any observation periods of centric occlusion and centric relation. 3. In vertical changes of condylar position of the wire fixation group. the condyles were moved inferiorly 4-6 weeks after surgery, and then the pattern of reestablishment to their preoperative position was observed more than 6 months after surgery. In the rigid fixation group, the condyles were moved inferiorly 4-6 weeks after surgery, and then the pattern of reestablishment to their preoperative position was observed more than 6 months after surgery in centric occlusion only.

  • PDF

TightRope$^{TM}$ Device를 이용한 족근 중족 관절 손상의 치료(1예 보고) (Lisfranc Injury Repair with the TightRope$^{TM}$ Device (A Case Report))

  • 조재호;오인석
    • 대한족부족관절학회지
    • /
    • 제15권4호
    • /
    • pp.243-246
    • /
    • 2011
  • Lisfranc injury is complex and difficult to treat. Making the correct diagnosis and achieving an anatomical reduction are important factors in regard to achieving a favorable outcome with this injury. We describe a new technique that we have found to be useful for stabilizing Lisfranc injury. This method is relatively fast and simple, and it provides non-rigid fixation. Also, it eliminates the need for implant removal. To date, we have achieved predictable results for stabilizing and treating this injury with the use of a $TightRope^{TM}$ Device, instead of traditional interfragmental screw fixation. In this report, we describe a case in which this method was used with satisfactory short-term results.

흡수성 망상판과 나사를 이용한 안면골절의 견고정법 (Rigid Fixation using Bioabsorbable Mesh and Screws in Facial Bone Fracture)

  • 신동혁;김덕중;김수영;황은아;최현곤;김순흠;엄기일
    • Archives of Plastic Surgery
    • /
    • 제37권5호
    • /
    • pp.717-720
    • /
    • 2010
  • Purpose: Absorbable plate and screw fixation is widely used technique for internal rigid fixation in craniomaxillofacial surgery. However, there are some potential problems associated with the use of plate. The purpose of this study is to evaluate the feasibility of bone fixation in facial fracture using absorbable mesh in place of absorbable plate. Methods: The records of 55 patients with zygomaticomaxilla fractures treated by open reduction, performed by the author from February 2008 to May 2009, were retrospectively reviewed. Patients were selected to receive absorbable mesh fixation. The incidence of all complications including infection, hypoesthesia, and deformity was examined. Analysis with postoperative computed tomography follow-up demonstrates degree of reduction. Results: Forty-six patients met criteria for inclusion in the study. All patients went on to satisfactory healing without complication. Postoperative computed tomography revealed good bony alignment similarly non affected side. Conclusion: This study demonstrates that the rigid internal fixation of fractured bone fragments using absorbable mesh is more effective than absorbable plate, especially in comminuted fracture of maxilla.

비고정 방법을 사용한 관골 체부 골절 정복술 (Open Reduction and Non-fixation Method for the Zygoma Body Fracture)

  • 박보영;김양우;강소라
    • 대한두개안면성형외과학회지
    • /
    • 제10권2호
    • /
    • pp.76-80
    • /
    • 2009
  • Purpose: Zygoma is a major portion of the midfacial skeleton, forms the malar prominence and the three adjacent bony articulations. Zygoma fracture is a very common in facial trauma. Open reduction and rigid fixation of displaced zygoma fractures are necessary to avoid immediate and delayed facial asymmetry and depression. However, it is possible to happen the complications related to the plates and screws. So, we planned to treat the 24 patients of Group II, III, IV zygoma fractures with precise reduction and non-fixation method via intraoral approach. Methods: From August, 2006, to August, 2009, we treated 24 cases of zygoma fracture with reduction and non-fixation methods. Before the surgery, we choose the patients who could be treated with this method among the Group II, III, IV patients. Results: No patients in this study had postoperative complications such as displacement of bony fragments, facial depression and asymmetry, malocclusion, hypoesthesia. Satisfactory aesthetic and functional results can be obtained. Conclusion: In the treatment of the zygoma fracture, it is possible to treat with precise reduction and non-fixation method. The greatest advantage is to decrease the operative time, no need to wide dissection, no complications related to the plates and screws. For the using of this method, it is necessary to choose the adequate patients through the preoperative planning.

악교정 골성형술후 약관절 장애의 변화 (CHANGES IN TEMPORO-MANDIBULAR DISORDERS FOLLOWING THE ORTHOGNATHIC SURGERIES)

  • 김명래;성만호;박창환
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제15권3호
    • /
    • pp.178-181
    • /
    • 1993
  • Sixty four patients were followed-up for over 6 months following the orthognathic surgeries and were examined for the Temporo-mandibular joint dysfunction. The results are as follows: 1. Of 64 patients, 9(14.1%) had been suffered from TMD preoperatively : 4.7% in the prognathism and 46.2% in the laterognathism. 2. Following the orthognathic surgeries, 7 of 64 patients(10.9%) complained TMD, and 55.6% of the TMD patients resulted in significant improvement. 3. By the type of deformities, laterognathism with TMD could be expected to be improved in 30.8%, while 7.7% in the prognathism. 4. Non-rigid fixation resulted in higher incidence of TMD than the Rigid fixation after the SSRO ; 4 of 15(26.5%) and 2 of 25(8.0%) respectively.

  • PDF

Treatment of Mandibular Angle Fractures

  • Lee, Jung-Ho
    • 대한두개안면성형외과학회지
    • /
    • 제18권2호
    • /
    • pp.73-75
    • /
    • 2017
  • The management of mandibular angle fractures is often challenging and results in the highest complication rate among fractures of the mandible. In addition, the optimal treatment modality for angle fractures remains controversial. Traditional treatment protocols for angle fractures have involved rigid fixation with intraoperative maxillomandibular fixation (MMF) to ensure absolute stability. However, more recently, non-compression miniplates have gained in popularity and the use of absolute intraoperative MMF as an adjunct to internal fixation has become controversial. In this article, the history of, and current trends in, the treatment of mandibular angle fractures will be briefly reviewed. In addition, issues regarding the management of the third molar tooth will be discussed.

A Review of Subbrow Approach in the Management of Non-Complicated Anterior Table Frontal Sinus Fracture

  • Kim, Jeenam;Choi, Hyungon
    • 대한두개안면성형외과학회지
    • /
    • 제17권4호
    • /
    • pp.186-189
    • /
    • 2016
  • Frontal sinus fractures, particularly anterior sinus fractures, are relatively common facial fractures. Many agree on the general principles of frontal fracture management; however, the optimal methods of reduction are controversial. The subbrow approach enables accurate reduction and internal fixation of the fractures in the anterior table of the frontal sinus by allowing direct visualization of the fracture. Given the surgical success in reduction and rigid fixation, patient satisfaction, and aesthetic benefits, the transcutaneous approach through a subbrow incision is superior to other reduction techniques used in the management of an anterior table frontal sinus fracture.

당뇨환자의 불안정 족관절에 있어서의 전방 T자형 금속판을 이용한 족관절 고정술 (Ankle Arthrodesis Using an Anterior T Plate in treating the Charcot joint of Ankle in a diabetic patient - A Case Report -)

  • 황건성;성일훈;조수현
    • 대한족부족관절학회지
    • /
    • 제5권1호
    • /
    • pp.23-27
    • /
    • 2001
  • It has been known that the ankle arthrodesis is a common surgical procedure for treating the ankle arthrosis and deformity that do not respond to the non-operative treatment. To date, various surgical techniques for the ankle arthrodesis have been reported. Clinical and biomechanical trials have shown that the rigid internal fixation leads the increased rate of the union. The ankle arthrodesis may be complicated with the nonunion, delayed union, malunion, and infection. In cases of the Charcot joint of the ankle in diabetic patients, however, arthrodesis could reduce the disadvantage of the nonoperative treatment, such as the loss of the reduction, progressive collapse, multiple ulcerations and infection. The object of this case report is to report our experience of a successful ankle arthrodesis using an anterior T plate in treating the unstable ankle of a diabetic patient, associated with the ankle fracture and the neuropathy. The surgical approach of this technique is simple so that it would allow less soft tissue injury, and this procedure would be regarded as one alternative to provide the rigid internal fixation in the ankle arthrodesis.

  • PDF

하악골 골절환자에서 술후 자가통증조절장치와 근주용 진통제의 효과에 관한 비교 (A COMPARATIVE STUDY ON POST-OPERATIVE ANALGESIC EFFECT FOR PATIENT-CONTROLLED AND INTRAMUSCULAR ANALGESIA IN MANDIBULAR FRACTURE PATIENTS)

  • 이석재;김경욱;김철환
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제28권1호
    • /
    • pp.42-48
    • /
    • 2006
  • Open reduction and rigid internal fixation is the most popular treatment method for maxillofacial fracture patients, and it is unevitable that postoperative pain can be developed. Many surgeons including oral & maxillofacial surgeons have made constant efforts to decrease postoperative pain. This study is a comparison of postoperative analgesia and intramuscular analgesia in patients with mandibular fractures. In this study, twenty-one patients (Experimental group) were randomly selected and they were injected with IV patient-controlled analgesia (PCA; Walkmed$^{(R)}$, USA). For control group another twenty-one patients were injected with intramusclar non-steroid anti-inflammatory drugs (Rheoma$^{(R)}$, Samsung Pharm. Co.). And then, we measured visual analogue scale (VAS) scores from first postoperative day to second day at regular time interval. The following results were uptained; 1. In patient group who with open reduction and rigid internal fixation, there was significant difference of postoperative analgesic effect during the first postoperative day(p<0.05). 2. In patient group with over 90 minutes surgery time, there was significant difference of postoperative analgesic effect during the first and second postoperative day when compared between experimental group and control group(p<0.05). 3. In patient group with less than 90 minutes surgery time, there was no significant difference of postoperative analgesic effect during the first and second postoperative day when compared between experimental group and control group(p>0.05). 4. In patient group with surgery of open reduction using rigid internal fixation at single fractured site, there was no significant difference of postoperative analgesic effect during the first and second postoperative day when compared between experimental group and control group(p>0.05). 5. In patient group with surgery at two fractured sites, there was significant difference of postoperative analgesic effect during the first postoperative day when compared between experimental group and control group(p<0.05). As mentioned above, it suggest that patient-controlled analgesia is more effective for postoperative pain relief than intramuscular injection in patients with rigid internal fixation by open reduction after mandibular fracture occurred. Especially, it is considered that in patient with more than 90 minutes surgery time or in cases with multiple fractured sites had more effective results with PCA therapy than conventional intramuscular analgesics.

The Mechanical Effect of Rod Contouring on Rod-Screw System Strength in Spine Fixation

  • Acar, Nihat;Karakasli, Ahmet;Karaarslan, Ahmet A.;Ozcanhan, Mehmet Hilal;Ertem, Fatih;Erduran, Mehmet
    • Journal of Korean Neurosurgical Society
    • /
    • 제59권5호
    • /
    • pp.425-429
    • /
    • 2016
  • Objective : Rod-screw fixation systems are widely used for spinal instrumentation. Although many biomechanical studies on rod-screw systems have been carried out, but the effects of rod contouring on the construct strength is still not very well defined in the literature. This work examines the mechanical impact of straight, $20^{\circ}$ kyphotic, and $20^{\circ}$ lordotic rod contouring on rod-screw fixation systems, by forming a corpectomy model. Methods : The corpectomy groups were prepared using ultra-high molecular weight polyethylene samples. Non-destructive loads were applied during flexion/extension and torsion testing. Spine-loading conditions were simulated by load subjections of 100 N with a velocity of $5mm\;min^{-1}$, to ensure 8.4-Nm moment. For torsional loading, the corpectomy models were subjected to rotational displacement of $0.5^{\circ}\;s^{-1}$ to an end point of $5.0^{\circ}$, in a torsion testing machine. Results : Under both flexion and extension loading conditions the stiffness values for the lordotic rod-screw system were the highest. Under torsional loading conditions, the lordotic rod-screw system exhibited the highest torsional rigidity. Conclusion : We concluded that the lordotic rod-screw system was the most rigid among the systems tested and the risk of rod and screw failure is much higher in the kyphotic rod-screw systems. Further biomechanical studies should be attempted to compare between different rod kyphotic angles to minimize the kyphotic rod failure rate and to offer a more stable and rigid rod-screw construct models for surgical application in the kyphotic vertebrae.