• Title/Summary/Keyword: Non-point source pollution management

Search Result 185, Processing Time 0.029 seconds

Characteristics of EMCs for Roof Runoff (강우시 지붕유출수의 EMCs 및 특성비교)

  • Hong, Jung Sun;Geronimo, Franz Kevin F.;Mercado, Jean Margaret R.;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.14 no.4
    • /
    • pp.657-665
    • /
    • 2012
  • The development projects distort the natural water circulation system and increase the non-point source pollution by changing the natural cover type. The low impact development (LID) techniques are considering as new development approach to decrease the ecological- and hydrological impacts from high imperviousness rate. The high imperviousness rate is because of the construction of building, parking lot and road for human activities. Knowing the basic characteristics of rood runoff can give the direction for setting up the water management strategy. The monitoring results show the pollutant EMCs of roof runoff are 3~13 times lower than EMCs of the road and parking lot. The pollutant sources from roof runoff are mainly from leafs, cigarette butts, atmospheric deposition and materials of the roof. The EMC is occurred around 15minutes later after starting runoff and more than 8 storm events are needed to have the average EMCs.

Development of Infiltration System for Stormwater Management from Paved Area (포장지역 강우유출수 관리를 위한 침투도랑 기술개발)

  • Lee, Jeong-Yong;Maniquiz, Marla C.;Lee, So-Young;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.12 no.3
    • /
    • pp.165-175
    • /
    • 2010
  • Recently, various development projects have occurred due to rapid industrialization and urbanization. Both industry and population grew rapidly which causes a corresponding rise in pollution. The accumulated pollutants are washed-off during rainy days, highly degrading the water quality of the receiving water body. This is because a lot of non point source (NPS) pollutants were accumulated on the surface during dry periods. This research focuses on the development of Eco-Bio Filter (EBF) system that treats NPS pollutants. It is constructed at Kongju National University campus. The EBF is a type of a structured infiltration system that falls under the category of Low Impact Development (LID) hydrologic design practices. The monitoring of rain events was performed. It includes the development of design, the lessons learned from the post-construction testing and the improvements in the renovation made. After a series of monitoring, the MOE will use the results to apply the design to other areas in the country.

Performance Evaluation of Combined Sewer Overflow Treatment using Filtration Pilot Device (파일럿 여과장치를 이용한 합류식하수관 월류수 처리성능 평가)

  • Lee, Jun Ho;Shin, Young Gyun
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.5
    • /
    • pp.409-417
    • /
    • 2019
  • In this study, a $480m^3/day$ pilot device was constructed through laboratory experiments based on the Ministry of Environment manual. The purpose of this study was to analyze the characteristics of CSO treatment and backwashing characteristics by applying the pilot device to the field. The purpose of this study was to acquire the basic data necessary for the design and operation management of the real scale filtration type non-point pollution control system. The filtration was conducted while maintaining the linear velocity of 20m/hour. The CSO treatment efficiencies of the pilot devices were 0.4-76.1%(mean 49.0 %), SS 51.4-91.6%(mean 77.8%), COD 22.2-59.4% (mean 38.3%) and TP 14.5-52.6%(mean 38.1%),respectively. The correlation coefficient between SS and the turbidity of influent water was 0.90, higher than that of CSO. To operate the treatment system effectively, the turbidity can be easily measured in real time as the monitoring item is the most appropriate because SS is the main target substance of the non-point source. As a result of analyzing the adsorbent treatment characteristics of PP filter material applied to this pilot device, the average particle diameter range of influent was $4.6-40.1{\mu}m$(mean $21.2{\mu}m$) and the treated water was $0.9-24.5{\mu}m$(mean $6.4{\mu}m$), respectively. Particles of approximately 10m or less are leached out, and so it is necessary to compensate for the raw water containing micro particulate matter.

Evaluation of Nonpoint Pollutant Management Effect by Application of Organic Soil Ameliorant Based on Renewable Resources in Urban Watershed (도시유역에서 재생자원기반 유기성 토량개량제 적용에 따른 비점오염물질 관리 효과 평가)

  • Yoonkyung Park;Chang Hyuk Ahn
    • Journal of Korean Society on Water Environment
    • /
    • v.40 no.3
    • /
    • pp.131-139
    • /
    • 2024
  • This study investigated the chemical properties of Organic Soil Amendments (OSAs) made from organic waste. It also assessed the effectiveness of using these OSAs in the soil layer of Green Infrastructure (GI) to reduce stormwater runoff and non-point source pollutants. The goal was to improve the national environmental value through resource recycling and contribute to the circular economy transformation and carbon neutrality of urban GI. The OSAs used in this study consisted of spent coffee grounds and food waste compost. They were found to be nutrient-rich and stable as artificial soils, indicating their potential use in the soil layer of GI facilities. Applying OSAs to bio-retention cells and permeable pavement resulted in a reduction of approximately 11-17% in stormwater runoff and a decrease of about 16-18% in Total Phosphorus (TP) discharge in the target area. Increasing the proportion of food waste compost in the OSAs had a positive impact on reducing stormwater runoff and pollutant emissions. This study highlights the importance of utilizing recycled resources and can serve as a foundation for future research, such as establishing parameters for assessing the effectiveness of GI facilities through experiments. To enable more accurate analysis, it is recommended to conduct studies that consider both the chemical and biological aspects of substance transfer in OSAs.

Characteristics of NPS Pollutants and Treatment of Stormwater Runoff in Paved Area during a Storm (강우시 포장지역의 비점오염물질 유출 및 저감특성)

  • Son, Hyun-Geun;Lee, So-Young;Maniquiz, Marla C.;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.11 no.2
    • /
    • pp.55-66
    • /
    • 2009
  • The increase of pollutant loadings from nonpoint sources affect the water quality of the major rivers in Korea. Consequently, the need for managing the nonpoint source (NPS) pollution becomes the main concern of the Korean Ministry of Environment (MOE). Recently, the policy was changed from pollutant concentration-restricting approach to the total maximum daily load (TMDL) approach to improve the water quality and protect the aquatic ecosystem. Part of the program is the construction of Best Management Practice (BMP) pilot facilities basically to control NPS. Most of the BMPs adopted were foreign technologies which could not be properly employed in the country due to some limitations such as climate, watershed characteristics, etc. In other words, to be able to apply the BMPs, research on its applicability is necessary. In this study, a three-year monitoring has been conducted to assess the treatment performance of the BMP installed in highway toll plaza and parking lot. The data gathered aid in the characterization of NPS pollutants in runoff and estimation of the pollutant removal efficiency of the BMP. The results will be used for the future implementation of BMP in different land uses as well as for the determination of optimum operation and maintenance.

  • PDF

A Production Method of Landslide Hazard Map by Combining Logistic Regression Analysis and AHP(Analytical Hierarchy Process) Approach Selecting Target Sites for Non-point Source Pollution Management Using Analytic Hierarchy Process

  • Lee, Yong-Joon;Park, Geun-Ae;Kim, Seong-Joon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.3
    • /
    • pp.63-68
    • /
    • 2007
  • The LRA(Logistic Regression Analysis) conducts a quantitative analysis by collecting a lot of samples and the AHP(Analytic Hierarchy Program) makes use of expert decision influenced by subjective judgment to a certain degree. This study is to suggest a combination method in mapping landslide hazard by giving equal weight for the result of LRA and AHP. Topographic factors(slope, aspect, elevation), soil dram, soil depth and land use were adopted to classify landslide hazard areas. The three methods(LRA, AHP, the combined approach) was applied to a $520km^2$ region located in the middle of South Korea which have occurred 39 landslides during 1999 and 2003. The suggested method showed 58.9% matching rate for the real landslide sites comparing with the classified areas of high-risk landslide While LRA and AHP Showed 46.1% and 48.7% matching rates respectively. Further studies are recommended to find the optimal combining weight of LRA and AHP with more landslide data.

Impacts of Impevious Cove Change on Pollutant Loads from the Daejeon-Stream Watershed Using AnnAGNPS (논문 - AnnAGNPS를 이용한 대전천 유역의 불투수면 변화에 따른 배출부하량 평가)

  • Chang, Seung-Woo;Kang, Moon-Seong;Song, In-Hong;Chung, Se-Woong
    • KCID journal
    • /
    • v.18 no.2
    • /
    • pp.3-14
    • /
    • 2011
  • Increased impervious surfaces alter stream hydrology resulting in lower flows during droughts and higher peak flows during floods. Not only urban area but also rural area has been expanded impervious surfaces because of increasing of greenhouses. The main objective of this study was to evaluate the performance of the AnnAGNPS (Annualized Non-Point Source Pollution Model) on the surface runoff characteristics of the Daejeon-Stream watershed, and to predict the hydrological effects due to increasing of impervious surfaces. The model parameters were obtained from the geographical information system (GIS) databases, and additional parameters calibrated with the observed data. The model was calibrated by using 2004 of the runoff data and validated by using 2002 data obtained from WAMIS (Water Management Information System) to compare the simulated results for the study watershed. R2 values and efficiency index (EI) between observed and simulated runoff were 0.78 and 0.80, respectively at the calibration period. In this study, expanding of impervious surfaces such as greenhouses caused increasing of surface runoff, but caused decreasing of total nitrogen and total phosphorus loads.

  • PDF

Selecting Target Sites for Non-point Source Pollution Management Using Analytic Hierarchy Process (계층분석적 의사결정기법을 이용한 비점원오염 관리지역의 선정)

  • Shin, Jung-Bum;Park, Seung-Woo;Kim, Hak-Kwan;Choi, Ra-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.976-980
    • /
    • 2007
  • 본 논문에서는 비점원오염 관리를 위한 지역선정을 위하여 계층분석적 의사결정기법에 의한 접근 방법을 제시하였다. 주어진 유역 내에서의 비점원오염의 중요기여 인자간의 관계를 반영한 것이 본 연구의 특징이다. 주요인자로는 경사도, 유달거리, 유효강우비, 불투수면적비, 토양유실량이다. 각 인자의 가중치는 계층분석적 의사결정기법(AHP)으로 구하였으며 각 인자의 가중값과 속성 값의 단순 부가가중 합으로 표현되는 비점원오염 영향지수를 정의하였다. 높은 영향지수를 가지는 지역을 비점원오염 관리지역으로 제안하였으며, 시험유역으로 발안HP#6유역을 선정하여 적용해보았다. 관리지역 결과를 비교하기 위하여 AGNPS 모의를 통한 비점원오염 부하량간의 분석을 시도하였다. 비교 및 분석을 위해 Moran's I를 이용하였으며, T-N은 $0.38{\sim}0.45$, T-P는 $0.15{\sim}0.22$의 범위를 보였다. 이는 두 접근 방법이 상이함에도 공간적으로 유사한 경향을 보인다는 것을 말한다. 본 연구에서 제시하는 방법은 비점원오염 관리지역 선정에 있어서 적용가능 함을 의미한다.

  • PDF

Evaluating the Modular Facility of Non-point Source Pollution Management for Improving Lake Water Quality (상수원 수질개선을 위한 비점관리 모듈화 시설의 적용성 평가)

  • Park, Jong-Yoon;Rhee, Han-Pil;Son, Jang-Won;Lee, Seung-Jae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.48-48
    • /
    • 2022
  • 본 연구에서는 상수원 수질개선을 위한 물환경관리 종합대책의 일환으로 장치형과 자연형 물환경관리시설을 복합 구성하여 강우 및 비강우 시 비점오염물질을 집중 저감 할 수 있는 맞춤형 비점관리 모듈화 시설을 제안하고, 그 적용성을 평가하고자 하였다. 이는 습지, 생태수로, 저류지 등으로 정형화된 기존의 수질개선 대책에서 탈피하여 대규모 댐유역에서 구조적 대책의 실효성과 효과성을 도모하기 위한 목적성을 지니고 있다. 이를 위해, 영천댐 유역을 대상으로 수질모형(HSPF, AEM3D)을 구축하고 목표수질 설정에 따른 수질개선 대책을 마련하였다. 여기서 수질개선 대책은 호내와 유역으로 공간적 범위를 구분하여 효과분석을 위한 단일 및 복합 모의 시나리오를 작성했으며, 평년 강우량과 가장 유사한 최근(2017년)의 영천호 수질과 비교하여 개선 효과를 평가하였다. 맞춤형 비점관리 모듈화 시설은 영천호 유입부에 기 조성된 인공습지(평시)와 연계하여 강우 시에는 모듈형(다기능 저류조, 스크린, 고효율여과) 장치를 통해 침강지로 최종 방류하는 것으로 구성하였다. 모듈화 시설의 연중 삭감량 추정 결과는 T-P 유달부하량을 기준으로 평시 32%, 강우 시 11%로 분석되었다. 자세한 모듈화 시설의 구성과 저감효율, 수질개선 대책 시나리오 적용에 따른 영천호 수질변화 분석 결과 등은 발표를 통해 제시될 예정이다.

  • PDF

Small-Scale Pond Effects on Reducing Pollutants Load from a Paddy Field (논의 양분유출 저감을 위한 저류지 효과)

  • Kim, Min-Kyeong;Kwon, Soon-Ik;Jung, Goo-Bok;Hong, Seong-Chang;Chae, Mi-Jin;Yun, Sun-Gang;So, Kyu-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.32 no.4
    • /
    • pp.355-358
    • /
    • 2013
  • BACKGROUND: Water-born pollution loads by agricultural non-point source (NPS) pollution are expected to become intensified due to ongoing precipitation change. Therefore, it is essential to develop a best management practice (BMP) that is suitable to agricultural environments in Korea. This study aimed to develop an environmental-friendly BMP to reduce NPS pollution load by agricultural activities. An eco-friendly way, small drainage pond, was suggested in this study to avoid direct drainage of agricultural runoffs and eventually reduce the amount of pollutants discharged into the surrounding aqua-environment. METHODS AND RESULTS: A small pond ($12m^2$) was constructed at the corner of a rice paddy field ($1,715m^2$) located in Suwon, Korea. Water was allowed to drain only via a small drainage pond. Sampling was repeatedly made at two locations, one from an entrance and the other from an exit of a pond, during the rice cultivation period (May to October, 2012). Generally, sampling was made only when runoff water drained through a pond, such as during and/or after rain (irrigation). The water quality analysis showed that all quality parameters (SS, $COD_{Mn}$, T-N, and T-P) were improved as water passed through the pond. The amount of runoff water was reduced by 96~100%. Suspended solids and COD concentrations was reduced by 79.3% and 45.6%, respectively. In case of T-N and T-P concentrations, the reduction rates were 52.2% and 60.5%, respectively and the amount of T-N and T-P were reduced by 16.3~73.0% and 15.4~70.1%, respectively. CONCLUSION(S): Our data implies that agricultural NPS pollution from rice paddy fields can be effectively managed when an appropriate drainage water management practice is imposed. In this paper, it was suggested that an installation of a small drainage pond can be effective to prevent not only the nutrient loss from rice fields but also pollutant discharge to surrounding water environments.