• Title/Summary/Keyword: Non-point pollution source (NPS)

Search Result 70, Processing Time 0.021 seconds

Long-term changes of water quality with regard to main Pollutant Sourses in Agricultural Reservoirs (주오염원별 농업용저수지의 장기 수질특성변화)

  • Choi, Sun-Hwa;Kim, Ho-Il;Yoon, Kyung-Seup;Park, Jong-Min
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.425-428
    • /
    • 2002
  • This study has been carried out to analized of long term changes of water quality with regard to main pollutant sources in agricultural reservoirs on the basis of data during 1996-2001. The major source was domestic wastewater(DWW) and water pollution by non-point sources(NPS) is increasing as time goes. It was determined that Seasonly average values of DWW were pH $7.6{\sim}8.7$, COD $7.0{\sim}9.4$, T-N $0.74{\sim}2.07$, T-P $0.05{\sim}0.62$, Live-stock wastewater(LWW) were pH $7.5{\sim}8.9$, COD $5.5{\sim}9.8$, T-N $0.57{\sim}1.91$, T-P $0.04{\sim}0.13$, NPS were pH $7.1{\sim}8.3$, COD $3.1{\sim}5.2$, T-N $0.29{\sim}1.44$, T-P $0.02{\sim}0.07$. Fluctuation of DWW and LWW were very wide and variable long term patterns of them were similar. Trophic states by Carlson Index of DWW and LWW was classified as eutrophic to hypretrophic from chl-a, T-P concentration.

  • PDF

Analysis of NPS Pollution Loads over Rainfall-Runoff Events from the Silica Mine Site (규사광산 지역의 강우시 비점오염원의 유출분석)

  • Choi, Yong-hun;Won, Chul-hee;Seo, Ji-yeon;Shin, Min-Hwan;Yang, Hee-Jeong;Choi, Joong-dae
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.3
    • /
    • pp.413-419
    • /
    • 2010
  • A silica mine monitoring was conducted from March to December in 2008 to measure rainfall, runoff amounts and pollution loads. A total of 13 rainfall-runoff events were measured and analyzed with respect to runoff ratio, pollutant concentration and load, and initial flush. Over rainfall-runoff events, 95% confidence range of SS concentration was 942.5~2,056.2 mg/L. Other measured water quality indices also showed relatively large variation. This wide concentration variation was thought to be caused by the bare working ground of the mine that was used to store, process and transport the mined silica. Total pollution load of the 13 rainfall-runoff events was SS 17,901 kg/ha, $COD_{Cr}$ 160.9 kg/ha, $COD_{Mn}$ 111.24 kg/ha, BOD 79.6 kg/ha, T-N 13.8 kg/ha, T-P 3.5 kg/ha, and TOC 39.3 kg/ha. Initial flush was not well observed except SS. Very high SS concentration and load was occurred when rainfall was large. Therefore, it was recommended to manage the bare ground not to discharge excessive pollutants during wet days by covering the ground or constructing runoff treatment systems such as a sediment basin.

Selection of Appropiate Plant Species of VFS (Vegetative Filter Strip) for Reducing NPS Pollution of Uplands (밭 비점오염저감을 위한 초생대 적정 초종 선정)

  • Choi, Kyung-Sook;Jang, Jeong-Ryeol
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.10
    • /
    • pp.973-983
    • /
    • 2014
  • This study focused on the selection of appropriate plant species of VFS (vegetative fiter strips) and the assessment of VFS effects for reducing NPS (non-point source) pollution from uplands. The experimental field was constructed with 1 control and 6 treated plots in the upland area of $1,500m^2$ with 5% slope which is located in Gunwi-gun, Gyeongbuk province. Six vegetation including Chufa, Common crabgrass, Barnyard grass, Turf grass, Tall fescue, Kenturky bluegrass, were applied to install VFS systems during the study period from June 2011 to Dec. 2012. The results of this study showed that 6.1~77.8% in runoff and 15.6~90.3% in TS, 49.9~96.6% in T-P, and 6.7~91.1% in T-N were reduced from the VFS treated plots. Generally high reduction effects were observed from TS, T-P, T-N, and SS, while BOD, TOC, and $NO_3^-$ showed low reductions. The best vegetation type was Turf grass showing higher reduction effects of NPS pollutions and having relatively easier maintenance efforts compared to other vegetations selected in this study. Based on these results, VFS technique found to be an effective management practice for reducing agricultural NPS pollutions in Korean upland conditions. Further study needs to be performed through various field experiments with long term monitoring in order to develop a design manual of VFS system for practical applications.

Runoff Characteristics of Non-point Source Pollutant Loads Generated on Golf Course (골프장에서 발생하는 비점오염원 유출특성)

  • Shin, Minhwan;Choi, Jaewan;Choi, Younghun;Park, Woonji;Won, Chulhee;Shin, Dongsuk;Lim, Kyoung Jae;Choi, Joongdae
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.6
    • /
    • pp.784-793
    • /
    • 2011
  • Activities on golf courses are believed to contribute to the degradation of water quality in receiving waters due to the excessive use of farm chemicals including fertilizers and pesticides. The objective of this study was to collect basic data that could explain the characteristics of non-point source (NPS) pollution discharged from a golf course. Twenty seven water quality monitoring was conducted at a golf course during the rainy season of 2008 and 2009. The results indicated that the ranges of the Event Mean Concentration (EMC) at the golf course were $BOD_5$ 1.8~11.3 (ave. 5.6) mg/L, $COD_{Mn}$ 19.2~51.4 (ave. 39.6) mg/L, TOC 11.0~31.0 (ave. 16.8) mg/L, TN 1.545~16.098 (ave. 5.623) mg/L, TP 0.230~4.528 (ave. 1.525) mg/L, and SS 2.2~57.3 (ave. 10.1) mg/L. The unit loads of the golf course estimated were $BOD_5$ $3.35kg/km^2/day$, SS $6.43kg/km^2/day$, $COD_{Mn}$ $30.00kg/km^2/day$, TN $4.04kg/km^2/day$, TP $1.14kg/km^2/day$, and TOC $12.16kg/km^2/day$. Golf courses are currently classified as a grass field in which the unit loads are different from golf courses. Therefore, it was recommended that golf courses need to be separated from the grass field when the surveys and modelings for Total Maximum Daily Load (TMDL) development and the evaluation of TMDL implementation were performed.

A Review of Research Trend Related to NPS and Suggestion for Research Direction in the Future (국내 비점오염 관련 연구 동향 및 향후 연구방향 제언)

  • Jeon, Jechan;Jung, Jeho;Kim, Yongseok;Kim, Lee-hyung
    • Journal of Wetlands Research
    • /
    • v.20 no.1
    • /
    • pp.80-93
    • /
    • 2018
  • Research trend about nonpoint pollution source(NPS) that have studied since 1980 was divided into 4 categories: 1) runoff characteristics of NPS, 2) treatment technique, 3) LID and green infrastructure(GI), 4) management practices and policy. This study reviews them and recommends the future research direction. The research on runoff characteristics of NPS until 2010 was mainly carried out. But recently, many researchers has been conducting studies on technology development, effect evaluation and field application. Providing best measures on NPS should be tried to conduct studies that many fields such as society, geography, meteorology and environment are fused. But it has not been enough yet. Because the cause material and optimum measures of NPS are different from each other regionally, it is considered that it needs studies to prepare measures and guidelines with regional characteristics rather than a uniform measures and guidelines by the central government. In addition, more comprehensive studies must be carried out to establish rules and regulations to manage NPS not only by government sector but also the private sector.

A Study on Development of Management Targets and Evaluation of Target Achievement for Non-point Source Pollution Management in Saemangeum Watershed (새만금 비점오염원 관리지역에서의 목표설정 및 달성도 평가방법론 연구)

  • Kim, Eun-Jung;Park, Bae-Kyung;Kim, Yong-Seok;Rhew, Doug-Hee;Jung, Kwang-Wook
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.8
    • /
    • pp.480-491
    • /
    • 2015
  • In this study, methods using LDC (Load Duration Curve) and watershed model were suggested to develope management targets and evaluate target achievement for non-point source pollution management considering watershed and runoff characteristics and possibility for achievement of target. These methods were applied for Saemangeum watershed which was designated as nonpoint source pollution management area recently. Flow duration interval of 5 to 40% was selected as flow range for management considering runoff characteristics and TP was selected as indicator for management. Management targets were developed based on scenarios for non-point source pollutant reduction of management priority areas using LDC method and HSPF model which was calibrated using 4 years data (2009~2012). In the scenario of LID, road sweeping and 50% reduction in CSOs and untreated sewage at Jeonju A20 and 30% reduction in fertilizer and 50% in livestock NPS at Mankyung C03, Dongjin A14 and KobuA14, management targets for Mangyung bridge, Dongjin bridge, Jeonju stream and Gunpo bridge were developed as TP 0.38, 0.18, 0.64 and 0.16 mg/L respectively. When TP loads at the target stations were assumed to have been reduced by a certain percentage (10%), management targets for those target stations were developed as TP 0.35, 0.17, 0.60 and 0.15 mg/L respectively. The result of this study is expected to be used as reference material for management master plan, implementation plan and implementation assessment for non-point source management area.

Water Quality Monitoring by Snowmelt in Songcheon, Doam Lake Watershed (도암호 유역의 융설에 의한 수질 변화 모니터링)

  • Kwon, Hyeokjoon;Hong, Dahye;Byeon, Sangdon;Lim, Kyoungjae;Kim, Jonggun;Nam, Changdong;Hong, Eunmi
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.3
    • /
    • pp.87-95
    • /
    • 2021
  • The Doam Lake Watershed is one of Gangwon-do's non-point source management areas. This area has a lot of snowfall in winter, and it is expected that there will be a lot of soil erosion in early spring due to snow melting. In this study, snow melting was monitored in the Doam Lake watershed from February to 3, 2020. It was conducted to analyze the water quality changes by calculating the concentration of non-point source pollution caused by snowmelt, and to compare the concentration of water quality during snowmelt event with rainfall and non-rainfall event. As a result of water quality analysis, Event Mean Concentration (EMC) at the first monitoring was SS 33.9 mg/L, TP 0.13 mg/L, TN 4.33 mg/L, BOD 1.35 mg/L, TOC 1.84 mg/L. At the second monitoring, EMC were SS 81.3 mg/L, TP 0.15 mg/L, TN 3.12 mg/L, BOD 1.32 mg/L, TOC 3.46 mg/L. In parameter except SS, it showed good water quality. It is necessary to establish management measures through continuous monitoring.

Assessment of Climate Change Impact on Best Management Practices of Highland Agricultural Watershed under RCP Scenarios using SWAT (SWAT모형을 이용한 RCP 기후변화 시나리오에 따른 고랭지농업유역의 최적관리기법 평가)

  • Jang, Sun-Sook;Kim, Seong-Joon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.4
    • /
    • pp.123-132
    • /
    • 2018
  • The purpose of this study was to evaluate the reduction effect of non point source (NPS) pollution in Haean highland agricultural catchment ($62.8km^2$) for 13 BMP scenarios under RCP (Representative Concentration Pathway) 4.5 and 8.5 scenarios. Under the present climate condition, the BMP (best management practices) reduction efficiency of SS (suspended solid), T-N (total nitrogen), and T-P (total phosphorus) showed +25.7%, +4.2%, and +16.1% for VFS (vegetative filter strip), +0.1%, +15.6%, and +5.7% for FC (fertilizer control), and +6.3%, -2.9%, and +3.9% for RSM (rice straw mulching) respectively. In general, effective was the best for SS and T-P reductions, and the FC was the best for T-N reduction. The negative effect of T-N on RSM was induced by increase in infiltration and solute transport to baseflow. Under the future climate change scenarios, the SS, T-N, and T-P reduction efficiency showed the range of +1.9~+11.6%, -1.9~+0.2%, and +5.3~+11.9% respectively. The 3 BMPs (VFS, FC, and RSM) application in the future showed negative and little differences (-0.5~+1.6%) for SS and T-N reduction efficiencies while T-P reduction efficiency showed +0.3~+7.6% comparing with the baseline period. To achieve an increase in the reduction efficiency of future SS and T-N by +2~+10%, the combined application of more than two BMPs is necessary.

Nitrogen Budget of South Korea in 2008: Evaluation of Non-point Source Pollution and $N_2O$ Emission (2008년도 대한민국 질소수지 연구: 비점오염증가 및 $N_2O$발생량산정)

  • Nam, Yock-Hyoun;An, Sang-Woo;Park, Jae-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.2
    • /
    • pp.103-112
    • /
    • 2011
  • The main objective of this research was to estimate Nitrogen budget of South Korea in 2008. Input-output budgets for nitrogen fluxes were categorized into three sections: cities, agricultural area, and forest. Chemical and biological fixation, dry and wet deposition, imported food and feed were used as the nitrogen input. Crop uptake, volatilization, denitrification, leaching, runoff, and forest consumption were used as the nitrogen outputs. Annual total nitrogen input was 1,294,155 ton/yr, and output was 632,228 ton/yr. Comparison with a previous research in 2005 indicates that nitrogen input was decreased by 1.9% due to the decrease in nitrogen fertilizer while nitrogen output was decreased by 6.3%. Non-point source (NPS) pollution was also estimated by mass balance approach, which increased by 22% than the previous research in 2005. The emission of nitrous oxide ($N_2O$) caused by denitrification was newly examined in this research. About 8,289 ton/yr of $N_2O$ was released from agriculture area and domestic wastewater treatment plant.

The Application of Nature-Based Technologies for Addressing Urban Environmental Problems (도시 환경 문제를 해결하기 위한 자연 기반해법의 적용)

  • Haque, Md Tashdedul;Reyes, Nash Jett DG.;Lee, Jung-min;Guerra, Heidi B.;Jeon, Minsu;Choi, Hyeseon;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.24 no.4
    • /
    • pp.367-376
    • /
    • 2022
  • LID technologies are capable of mitigating the negative impacts of non-point source (NPS) pollution generated in different land uses. Apart from the increase in point and non-point pollutant generation, highly developed and paved areas generally affect microclimate conditions. This study evaluated both the efficiency of Low Impact Development (LID) facilities in treating NPS pollutant loads as well as the unit pollutant loads (UPL) generated in various urban features (such as parking lots and highways). This investigation also looked at how LID technology helped to alleviate Urban Heat Island (UHI) conditions. As compared to the typical unit pollutant loads in South Korea, the unit pollutant loads at Kongju National University were relatively low, because of no classes, limited vehicular transmission, and low anthropogenic activities during vacation. After receiving treatment from the LID facilities, the effluent pollutant loads were significantly decreased. The sedimentation in filtration mechanisms considerably reduced the pollutant fractions in the influent. Additionally, it was shown that LID facilities' mean surface temperatures are up to 7.2℃ lower than the nearby paved environment, demonstrating the LID systems reducing the UHI impact on an urban area.