• Title/Summary/Keyword: Non-ionizing radiation

Search Result 87, Processing Time 0.026 seconds

Evaluation of Chromosomal Alteration in Electrical Workers Occupationally Exposed to Low Frequency of Electro Magnetic Field (EMFs) in Coimbatore Population, India

  • Balamuralikrishnan, Balasubramanian;Balachandar, Vellingiri;Kumar, Shanmugam Suresh;Stalin, Nattan;Varsha, Prakash;Devi, Subramaniam Mohana;Arun, Meyyazhagan;Manikantan, Pappuswamy;Venkatesan, Chinnakulandhai;Sasikala, Keshavarao;Dharwadkar, Shahnaz N.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.6
    • /
    • pp.2961-2966
    • /
    • 2012
  • Extremely low frequency electro magnetic fields (EMFs) have been classified as possibly carcinogenic to humans by the International Agency for Research on Cancer. An increased number of chromosomal alterations in peripheral lymphocytes are correlated with elevated incidence of cancer. The aim of the present study was to assess occupationally induced chromosomal damage in EMF workers exposed to low levels of radiation. We used conventional metaphase chromosome aberration (CA) analysis and the micronucleus (MN) assay as biological indicators of non ionizing radiation exposure. In the present study totally 70 subjects were selected including 50 exposed and 20 controls. Informed written consent was obtained from all participants and the study was performed in accordance with the Declaration of Helsinki and the approval of the local ethical committee. A higher degree of CA and MN was observed in exposed subjects compared to controls, the frequency of CA being significantly enhanced with long years of exposure (P<0.05). Moreover increase in CA and MN with age was noted in both exposed subjects and controls, but was significantly greater in the former. The results of this study demonstrated that a significant induction of cytogenetic damage in peripheral lymphocytes of workers occupationally exposed to EMFs in electric transformer and distribution stations. In conclusion, our findings suggest that EMFs possess genotoxic capability, as measured by CA and MN assays; CA analysis appeared more sensitive than other cytogenetic end-points. It can be concluded that chronic occupational exposure to EMFs may lead to an increased risk of genetic damage among electrical workers.

Discussion of Exposure Evaluation Associated with Extremely Low Frequency-magnetic Field in the Case of Portable Hand-held Fans (휴대용 손 선풍기의 극저주파 자기장 발생 수준 평가와 쟁점 고찰)

  • Park, Dong-Uk;Yi, Seongjin;Kim, So-Youn;Bae, Seo-Youn;Choi, Sangjun;Kim, Won;Min, Sung Hyon;Park, Jihoon;Ahn, Jongju
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.5
    • /
    • pp.480-490
    • /
    • 2018
  • Objective: This study aimed to report the level of extremely low frequency-magnetic field (ELF-MF) emitted by portable hand-held fans (HHF) and to discuss the methodologies for determining the health risk of ELF-MF for HHF products. Method: ELF-MF was monitored at eight locations by distances in the vicinity of HHFs. A total of 13 HHF brands on the market were randomly selected. A portable ELF-MF monitor MDEX II was used to measure the ELF-MF level in the range of 40-800 Hz with a resolution of $0.01{\mu}T$. This study also examined the frequency results of a total of 45 HHF products investigated by the Korean Ministry of Science and ICT (KMSICT). Results: ELF-MF higher than $0.3{\mu}T$ was found to be emitted at a distance of less than 20 cm from 12 HHF. ELF-MF emitted from four products was found to exceed the reference level ($83.3{\mu}T$ based on 60 Hz) recommended by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). KMSIT reported that the principle frequency emitted from the HHFs ranged from 54 Hz to 284 kHz, without the level of LEF-MF. Unscientifically, the KMSICT used the reference level by ICNIRP as the chronic level and concluded that all HHFs are safe with a basis of 1.2-36.0% less than the reference level. Conclusion: The HHF emitted much higher levels of ELF-MF than $0.3-0.4{\mu}T$, which is regarded as the reference level for childhood leukemia. The risk of HHF should be examined in terms of whether they can be used by the general public, including children and pregnant woman.

Endonuclease G is Upregulated and Required in Testicular Germ Cell Apoptosis after Exposure to 60 Hz at 200 μT

  • Park, Sungman;Kim, Min-Woo;Kim, Ji-Hoon;Lee, Yena;Kim, Min Soo;Lee, Yong-Jun;Kim, Young-Jin;Kim, Hee-Sung;Kim, Yoon-Won
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.3
    • /
    • pp.142-150
    • /
    • 2015
  • Several reports supported that continuous exposure to 60 Hz magnetic field (MF) induces testicular germ cell apoptosis in vivo. We recently evaluated duration- and dose-dependent effects of continuous exposure to a 60 Hz MF on the testes in mice. BALB/c male mice were exposed to a 60 Hz MF at $100{\mu}T$ for 24 hours a day for 2, 4, 6, or 8 weeks, and at 2, 20 or $200{\mu}T$ for 24 hours a day for 8 weeks. To induce the apoptosis of testicular germ cell in mice, the minimum dose is $20{\mu}T$ at continuous exposure to a 60 Hz MF for 8 weeks, and the minimum duration is 6 weeks at continuous exposure of $100{\mu}T$. Continuous exposure to a 60 Hz MF might affect duration- and dose-dependent biological processes including apoptotic cell death and spermatogenesis in the male reproductive system of mice. The safety guideline of the International Commission on Non-Ionizing Radiation Protection (ICNIRP) indicates that the permissible maximum magnetic flux density for general public exposure is $200{\mu}T$ at 60 Hz EMF (ICNIRP Guidelines, 2010). In the present study, we aimed to examine the expression of pro- and anti-apoptotic genes regulated by the continuous exposure to 60 Hz at $200{\mu}T$ in Sprague-Dawley rats for 20 weeks. The continuous exposure to 60 Hz at $200{\mu}T$ does not affect the body and testicular weight in rats. However, exposure to 60 Hz MF significantly affects testicular germ cell apoptosis and sperm count. Further, the apoptosis-related gene was scrutinized after exposure to 60 Hz at $200{\mu}T$ for 20 weeks. We found that the message level of endonuclease G (EndoG) was greatly increased following the exposure to 60 Hz at $200{\mu}T$ compared with sham control. These data suggested that 60 Hz magnetic field induced testicular germ cell apoptosis through mitochondrial protein Endo G.

Early caries detection using optical coherence tomography: a review of the literature (광간섭단층촬영술을 이용한 치아우식증의 발견)

  • Park, Young-Seok;Cho, Byeong-Hoon;Lee, Seung-Pyo;Shon, Won-Jun
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.5
    • /
    • pp.367-376
    • /
    • 2011
  • Early detection of carious lesions increases the possibility of treatment without the need for surgical intervention. Optical coherence tomography (OCT) is an emerging three-dimensional imaging technique that has been successfully used in other medical fields, such as ophthalmology for optical biopsy, and is a prospective candidate for early caries detection. The technique is based on low coherence interferometry and is advantageous in that it is non-invasive, does not use ionizing radiation, and can render threedimensional images. A brief history of the development of this technique and its principles are discussed in this paper. There have been numerous studies on caries detection, which were mostly in vitro or ex vivo experiments. Through these studies, the feasibility of OCT for caries detection was confirmed. However, further research should be performed, including in vivo studies of OCT applications, in order to prove the clinical usefulness of this technique. In addition, some technological problems must be resolved in the near future to allow for the use of OCT in everyday practice.

Anti-Ionizing Radiation Effect of Selenium on Osteoporosis Model during Bone Repair Process (골다공증 모델의 뼈 재생기에 있어 셀레늄(Selenium)의 방사선 보호작용)

  • Kim, Hyun;Cho, Sang-Rae;Choe, Changyong;Seong, Hwan-Hoo
    • Journal of Embryo Transfer
    • /
    • v.30 no.3
    • /
    • pp.201-206
    • /
    • 2015
  • Selenium (Se) is an essential trace element for humans and animals, and several findings suggest that dietary Se intake may be necessary for bone health. Accumulating evidence indicates that Se compounds possess anticancer properties. Se is specifically incorporated into proteins in the form of selenocysteine and non-specifically incorporated as selenomethionine in place of methionine. This study evaluated protection by Se in the bone repair process in ovariectomized rats after irradiation. For such purpose, 80 ovariectomized female Sprague-Dawley rats were randomly divided into 4 experimental groups: ovariectomized (Ov), Ov/Se, Ov/irradiated (Irr) and Ov/ Se/Irr. A bone defect was created on the tibia of all animals 40 days after ovariectomy. Two days after surgery, only the Ov/Se and Ov/Se/Irr rats received 0.8 mg Se/kg. Three days after surgery, only the Ov/Irr and Ov/Se/Irr rats received 10 Gy of X-rays on the lower limb region. The animals were euthanized at 7, 15, 22 and 29 days after surgery to assess the repair process, which was evaluated by analysis of trabecular bone number (Masson Trichrome) and birefringence analysis (Picrosirius). It was possible to observe a delay in the bone repair process in the ovariectomized/irradiated group and similarity between the ovariectomized, Ov/ Se and Ov/Se/Irr groups. Our findings suggest that sodium selenite may influence a radioprotective effect in the bone repair of tibia of ovariectomized rats without toxicity.

Korean Clinical Imaging Guidelines for the Appropriate Use of Chest MRI (한국형 흉부 MRI 영상 진단 정당성 권고안)

  • Jiyoung Song;Bo Da Nam;Soon Ho Yoon;Jin Young Yoo;Yeon Joo Jeong;Chang Dong Yeo;Seong Yong Lim;Sung Yong Lee;Hyun Koo Kim;Byoung Hyuck Kim;Kwang Nam Jin;Hwan Seok Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.562-574
    • /
    • 2021
  • MRI has the advantages of having excellent soft-tissue contrast and providing functional information without any harmful ionizing radiation. Although previous technical limitations restricted the use of chest MRI, recent technological advances and expansion of insurance coverage are increasing the demand for chest MRI. Recognizing the need for guidelines on appropriate use of chest MRI in Korean clinical settings, the Korean Society of Radiology has composed a development committee, working committee, and advisory committee to develop Korean chest MRI justification guidelines. Five key questions were selected and recommendations have been made with the evidence-based clinical imaging guideline adaptation methodology. Recommendations are as follows. Chest MRI can be considered in the following circumstances: for patients with incidentally found anterior mediastinal masses to exclude non-neoplastic conditions, for pneumoconiosis patients with lung masses to differentiate progressive massive fibrosis from lung cancer, and when invasion of the chest wall, vertebrae, diaphragm, or major vessels by malignant pleural mesothelioma or non-small cell lung cancer is suspected. Chest MRI without contrast enhancement or with minimal dose low-risk contrast media can be considered for pregnant women with suspected pulmonary embolism. Lastly, chest MRI is recommended for patients with pancoast tumors planned for radical surgery.

A Study on Applied to Optimal Diagnostic Device in Portal Vein Visualization: Focused on MRI and CT (간문맥 묘출을 위한 최적의 영상진단 장치에 관한 연구: MRI, CT 중심으로)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.217-225
    • /
    • 2019
  • The purpose of this study was to quantitate signal to noise ratio and contrast to noise ratio of the portal vein using CT and 3.0T MRI and to investigate the optimal imaging device. Twenty patients who inspective CT and 3.0T MRI between February 2018 and April 2018 were randomly assigned to receive data from the picture archiving communication system. The SNR and CNR values were evaluated by measuring the mean and standard deviation of the region of interest of the four regions of the portal vein (the main portal vein, the right vein, the left vein, and the middle vein). The results showed that SNR was 9.180.72 in the right context, 9.410.84 in the left context, 9.540.59 in the middle context, 9.550.75 in the order context, and 22.292.03 in the right context and 25.893 in the 3.0T MRI. 19, median context: 24.392.87, and order Mac: 26.642.30 (p<0.05). CNR was 3.790.68 in the CT context, 3.740.65 in the left context, 3.710.39 in the middle context, 3.790.68 in the order context, 9.490.65 in the right context, and 11.0001.90 in the 3.0T MRI, Intermediate context: 12.701.75, order Mac: 10.010.98, 3.0T MRI was higher than CT (p<0.05). In conclusion, SNR and CNR values were higher in the 3.0T MRI than CT in the 4 portal regions. Therefore, 3.0T MRI using non-ionizing radiation was the most superior imaging equipment than CT.