• Title/Summary/Keyword: Non-invasive analysis

Search Result 291, Processing Time 0.033 seconds

A TOF-SIMS Study of Artificially Photoaged Silk Fabrics

  • Lee, Boyoung;Ryu, Hyoseon;Park, Sohyun
    • Journal of Conservation Science
    • /
    • v.34 no.2
    • /
    • pp.129-135
    • /
    • 2018
  • Scientific investigation of cultural heritage can provide important information to understand the context of the object. To know the characteristics of the material is also an essential part of objects management and conservation. However, the identification and characterization of organic dyes used in archaeological and historical textiles are often limited by the restrictions in sampling. To cope with the difficulties, applications of high-performance techniques of surface analysis, such as Time of Flight-Secondary Ion Mass Spectra (TOF-SIMS) could be considered as a non or micro-destructive option. This study aims to examine the applicability of TOF-SIMS analysis to the detection of organic dyes from historical textiles. A group of silk fabrics dyed with vegetable dyes were artificially photo-aged to different degrees and analyzed with TOF-SIMS. Molecular and fragment ions from indigo were successfully detected from the aged samples; however, only some fragment ions were observed from gardenia and safflower dyed fabrics. Further studies with actual historical samples with extended examination scope would be necessary to assess the validity of this technique.

Crop Growth Measurements by Image Processing in Greenhouse - for Lettuce Growth - (화상처리를 이용한 온실에서의 식물성장도 측정 -상추 성장을 중심으로-)

  • 김기영;류관희
    • Journal of Biosystems Engineering
    • /
    • v.23 no.3
    • /
    • pp.285-290
    • /
    • 1998
  • Growth information of crops is essential for efficient control of greenhouse environment. However, a few non-invasive and continuous monitoring methods of crop growth has been developed. A computer vision system with a CCD camera and a frame grabber was developed to conduct non-destructive and intact plant growth analyses. The developed system was evaluated by conducting the growth analysis of lettuce. A linear model that explains the relationship between the relative crop coverage by the crop canopy and dry weight of a lettuce was presented. It was shown that this measurement method could estimate the dry weight from the relative crop coverage by the crop canopy. The result also showed that there was a high correlation between the projected top leaf area and the dry weight of the lettuce.

  • PDF

Problems in the Pathologic Diagnosis of Suspected Lung Cancer

  • Soo Han Kim;Mi-Hyun Kim;Min Ki Lee;Jung Seop Eom
    • Tuberculosis and Respiratory Diseases
    • /
    • v.86 no.3
    • /
    • pp.176-182
    • /
    • 2023
  • Since the introduction of low-dose computed tomography (CT) screening for patients at high risk of lung cancer, the detection rate of suspicious lung cancer has increased. In addition, there have been many advances in therapeutics targeting oncogenic drivers in non-small cell lung cancer. Therefore, accurate pathological diagnosis of lung cancer, including molecular diagnosis, is increasingly important. This review examines the problems in the pathological diagnosis of suspected lung cancer. For successful pathological diagnosis of lung cancer, clinicians should determine the appropriate modality of the diagnostic procedure, considering individual patient characteristics, CT findings, and the possibility of complications. Furthermore, clinicians should make efforts to obtain a sufficient amount of tissue sample using non- or less-invasive procedures for pathological diagnosis and biomarker analysis.

A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS (공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구)

  • Park Cheol;Lim Ju-Hwan;Cho In-Ho;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.

Performance analysis of EIT bladder monitoring system according to input current patterns (주입전류 패턴에 따른 EIT 방광 모니터링 시스템의 성능분석)

  • Han, You-Jung;Khambampati, Anil Kumar;Kim, Kyung-Youn
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.164-172
    • /
    • 2019
  • Current clinical methods for diagnosing urination disorder are invasive, expensive, and very inconvenient to perform continuous monitoring. EIT is a non-invasive technique that injects electrical current through an external electrodes and measures the induced voltage to visualize the internal electrical (impedance) characteristics, which makes it possible to monitor bladder conditions with low cost. The signal characteristics of the measured voltage data changes according to the current pattern injected through the electrode and affects reconstruction performance. In this paper, image reconstruction performance is compared and analyzed according to the injected current patterns to maximize the sensitivity to the variation of bladder size.

A Study of Skin Biophysical Parameters and Biomarkers related to the Anatomical Site and Age in Korean Women (한국 여성의 피부 부위 및 연령에 따른 피부 측정 인자와 생물 인자 연구)

  • Cho, Seok-Cheol;Nam, Gaewon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.41 no.4
    • /
    • pp.413-420
    • /
    • 2015
  • The skin is one of the largest organs in our body and participates in many of the human organism's physiological and pathological events. Skin function were known for self-maintenance and self-repair, mechanical and chemical stress protection, protection against UV and environmental pathogenic micro-organisms, production of vitamin D, and social and psychological function through the physical aspect. The aim of this study was to evaluate the variation of biophysical parameters and to find relation with skin biomarkers in different anatomical site and age in Korean women. About 70 healthy volunteers in age range 20 to 49 were participated in this test. Test areas were the forearms and the cheek. Investigation to determine biophysical parameters on human skin, was carried out using various non-invasive methods. For analysis to skin biomarkers, we studied to examine various biomarkers for the quantitative determination of cortisol, fibronectin, keratin-1, 10, and 11, involucrin, and keratin-6 in human face and forearm. And we measured to skin biophysical parameters for skin anatomical site and age difference with non-invasive methods. As results of measuring site, some parameters were have following significant difference, stratum corneum hydration, trans epidermal water loss and skin color (L and a value). As results of age difference, skin colors were had only significant difference with age. For cortisol, keratin-6, fibronectin, keratin-1, 10, 11 contents, there were no significant difference in age and site. However, involucrin level in the cheeks were the highest for age group 30 ~ 39 compared to other age groups. These results suggest that in individual skin condition may explain detailed skin state variation.

Reliability of Non-invasive Sonic Tomography for the Detection of Internal Defects in Old, Large Trees of Pinus densiflora Siebold & Zucc. and Ginkgo biloba L. (노거수 내부결함 탐지를 위한 비파괴 음파단층촬영의 신뢰성 분석(소나무·은행나무를 중심으로))

  • Son, Ji-Won;Lee, Gwang-Gyu;An, Yoo-Jin;Shin, Jin-Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.36 no.5
    • /
    • pp.535-549
    • /
    • 2022
  • Damage to forests, such as broken or falling trees, has increased due to the increased intensity and frequency of abnormal climate events, such as strong winds and heavy rains. However, it is difficult to respond to them in advance based on prediction since structural defects such as cavities and bumps inside trees are difficult to identify with a visual inspection. Non-invasive sonic tomography (SoT) is a method of estimating internal defects while minimizing physical damage to trees. Although SoT is effective in diagnosing internal defects, its accuracy varies depending on the species. Therefore, it is necessary to analyze the reliability of its measurement results before applying it in the field. In this study, we measured internal defects in wood by cross-applying destructive resistance micro drilling on old Pinus densifloraSiebold & Zucc. and Ginkgo bilobaL., which are representative tree species in Korea, to verify the reliability of SoT and compared the evaluation results. The t-test for the mean values of the defect measurement between the two groups showed no statistically significant difference in pine trees and some difference in ginkgo trees. Linear regression analysis results showed a positive correlation with an increase in defects in SoT images when the defects in the drill resistance graph increased in both species.

Development of Computer Vision System for Individual Recognition and Feature Information of Cow (II) - Analysis of body parameters using stereo image - (젖소의 개체인식 및 형상 정보화를 위한 컴퓨터 시각 시스템 개발(II) - 스테레오 영상을 이용한 체위 분석 -)

  • 이종환
    • Journal of Biosystems Engineering
    • /
    • v.28 no.1
    • /
    • pp.65-76
    • /
    • 2003
  • The analysis of cow body parameters is important to provide some useful information fur cow management and cow evaluation. Present methods give many stresses to cows because they are invasive and constrain cow postures during measurement of body parameters. This study was conducted to develop the stereo vision system fur non-invasive analysis of cow body features. Body feature parameters of 16 heads at two farms(A, B) were measured using scales and nineteen stereo images of them with walking postures were captured under outdoor illumination. In this study, the camera calibration and inverse perspective transformation technique was established fer the stereo vision system. Two calibration results were presented for farm A and fm B, respectively because setup distances from camera to cow were 510 cm at farm A and 630cm at farm B. Calibration error values fer the stereo vision system were within 2 cm for farm A and less than 4.9 cm for farm B. Eleven feature points of cow body were extracted on stereo images interactively and five assistant points were determined by computer program. 3D world coordinates for these 15 points were calculated by computer program and also used for calculation of cow body parameters such as withers height. pelvic arch height. body length. slope body length. chest depth and chest width. Measured errors for body parameters were less than 10% for most cows. For a few cow. measured errors for slope body length and chest width were more than 10% due to searching errors fer their feature points at inside-body positions. Equation for chest girth estimated by chest depth and chest width was presented. Maximum of estimated error fur chest girth was within 10% of real values and mean value of estimated error was 8.2cm. The analysis of cow body parameters using stereo vision system were successful although body shape on the binocular stereo image was distorted due to cow movements.

Association of Uric Acid Levels with Arterial Stiffness in Korean Women and Non-smoking Men

  • Sull, Jae Woong;Koh, Eun Na;Cho, Sung Kweon;Bae, Hyung-Joon;Jee, Sun Ha
    • Biomedical Science Letters
    • /
    • v.23 no.3
    • /
    • pp.201-207
    • /
    • 2017
  • Measuring the pulse wave velocity (PWV) is a non-invasive method for evaluating the stiffness of the vessel wall. While previous studies investigated the association of uric acid level with arterial stiffness, most did not consider smoking status and obesity as covariates. The objective of this study was to investigate the relationship between uric acid levels and arterial stiffness, considering smoking status and obesity. We studied 3390 subjects (1940 males and 1450 females). Abnormal PWV was also defined as the highest quartile of values in the subjects. Data were analyzed using Pearson correlation, t-test, and multiple regression analysis. Approximately 41.9% of men and 3.7% of women were current smokers. Prevalence of hypertension was 11.4% in men and 7.0% in women. In women, hyperuricemia was associated with abnormal PWV (OR 1.58; 95% CI 1.03~2.43). Hyperuricemia was also associated with abnormal PWV (OR 2.37; 95% CI 1.01~5.59) in non- or light male smokers with normal blood pressure. This study suggests that uric acid is associated with arterial stiffness in women and non-smoking men.

Serum Periplakin as a Potential Biomarker for Urothelial Carcinoma of the Urinary Bladder

  • Matsumoto, Kazumasa;Ikeda, Masaomi;Matsumoto, Toshihide;Nagashio, Ryo;Nishimori, Takanori;Tomonaga, Takeshi;Nomura, Fumio;Sato, Yuichi;Kitasato, Hidero;Iwamura, Masatsugu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.22
    • /
    • pp.9927-9931
    • /
    • 2014
  • The objectives of this study were to examine serum periplakin expression in patients with urothelial carcinoma of the urinary bladder and in normal controls, and to examine relationships with clinicopathological findings. Detection of serum periplakin was performed in 50 patients and 30 normal controls with anti-periplakin antibodies using the automatic dot blot system, and a micro-dot blot array with a 256 solid-pin system. Levels in patients with urothelial carcinoma of the urinary bladder were significantly lower than those in normal controls (0.31 and 5.68, respectively; p<0.0001). The area under the receiver-operator curve level for urothelial carcinoma of the urinary bladder was 0.845. The sensitivity and specificity, using a cut-off point of 4.045, were 83.7% and 73.3%, respectively. In addition, serum periplakin levels were significantly higher in patients with muscle-invasive cancer than in those with nonmuscle-invasive cancer (P = 0.03). In multivariate Cox proportional hazards regression analysis, none of the clinicopathological factors was associated with an increased risk for progression and cancer-specific survival. Examination of the serum periplakin level may play a role as a non-invasive diagnostic modality to aid urine cytology and cystoscopy.