• Title/Summary/Keyword: Non-injection

Search Result 1,053, Processing Time 0.038 seconds

Analysis of the Characteristics of the Change in the Moisture Rate of Landfill with Recirculation Water Injection (재순환수 주입에 따른 매립장 함수율 변화특성 분석)

  • Kim, Young-Kyu;Choi, Won-Young;Chun, Seung-Kyu
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.5
    • /
    • pp.39-48
    • /
    • 2021
  • Analysis of the change in water content and distribution was conducted according to the supply of recirculation water to a landfill. An excavation sample analysis showed that the recirculation water injection zone had water content 8.8% point higher than that of the non-injection zone, after 8 months of operation. And due to the influence of recirculation water supply by vertical wells in injection zones, the water content increases along with depth more clearly than non-injection zone. According to an electrical specific-resistivity survey after 13 months of operation, the water content got higher towards the bottom of the landfill. The water transmission coefficient is 8.72×10-4 cm/sec for injection zones and 3.36×10-5 cm/sec for the intermediate cover layer; analysis shows that the intermediate cover layer may affect the penetration velocity of water supplied by the horizontal injection tube. For the scientific design and operation of re-injection facilities, it was deemed necessary to follow-up research on the residence time and behavior of re-injection water considering the ratio of recirculation water supply in horizontal and vertical tubes, and pitcher coefficient of intermediate and waste layers.

Anesthetic efficacy of buffered 4% articaine for mandibular first molar infiltration: a crossover clinical trial

  • Kalliopi Manta;Nikolaos Dabarakis;Theodoros Lillis;Ioannis Fotopoulos
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.23 no.3
    • /
    • pp.135-141
    • /
    • 2023
  • Background: The limited studies on the effect of buffering on the clinical efficacy of articaine have reported controversial results. The purpose of this study was to clinically compare the pain of injection, anesthetic success, onset, and duration of pulpal anesthesia of buffered 4% articaine with epinephrine 1:100000 versus a non-buffered 4% articaine with epinephrine 1:100000 formulation for buccal infiltration of the mandibular first molar. Methods: Sixty-three volunteers were enrolled in the study. All volunteers received two injections consisting of a single mandibular first molar buccal infiltration with 1.8 ml of 4% articaine with epinephrine 1:100000 and 1.8 ml of 4% articaine with epinephrine 1:100000 buffered with 8.4% sodium bicarbonate. The infiltrations were applied in two separate appointments spaced at least one week apart. After injection of the anesthetic solution at the examined site, the first molar was pulp-tested every 2 min for the next 60 min. Results: Successful pulpal anesthesia was recorded in 69.8% of cases using non-buffered articaine solution and 76.2% of cases using buffered articaine solution, with no significant difference between the formulations (P = 0.219). The mean time of anesthesia onset for the volunteers with successful anesthetic outcome in both formulations (n = 43) was 6.6 ± 1.6 min for the non-buffered articaine solution and 4.5 ± 1.6 min for the buffered solution, which differed significantly (P = 0.001). In the same volunteers, the mean duration of pulpal anesthesia was 28.4 ± 7.1 min for non-buffered articaine solution and 30.2 ± 8.5 min for buffered articaine solution, with no significant difference between the formulations (P = 0.231). Considering the pain of injection, regardless of the anesthetic success, the mean values of VAS were 11.3 ± 8.2 mm for the non-buffered articaine solution and 7.8 ±6.5 mm for the buffered articaine solution, which differed significantly (P = 0.001 < 0.05). Conclusion: According to the present study, 4% articaine with epinephrine can benefit from buffering and provide better anesthetic behavior, with improved onset and less pain during injection.

Experimental Study on the Spray Behavior of Non-Esterification Biodiesel Fuel (비에스테르화 바이오디젤유의 분무거동에 대한 실험적 연구)

  • Choi, S.H.;Oh, Y.T.
    • Journal of ILASS-Korea
    • /
    • v.14 no.3
    • /
    • pp.117-121
    • /
    • 2009
  • Biodiesel fuel has different spray patterns, because viscosity and surface tension of biodiesel fuel are higher than that of diesel fuel. The diesel combustion is strongly controlled by the fuel spray behavior in combustion chamber. So, it was needed to understand the spay characteristics of non-esterification biodiesel fuel. In this study, the spray characteristics of non-esterification biodiesel fuel was investigated to confirm of an effect of WDP. The characteristics of fuel atomization was analyzed with SMD and span factor through laser diffraction particle analyzer (LDPA), and the process of spray injection was visualized through the visualization system composed of a halogen lamp and high speed camera. It was found that injection delay time and SMD of blended fuel with WDP get shoter and smaller than that of non-esterification biodiesel fuel.

  • PDF

An experimental study on initial dispersion process of diesel fuel spray (디젤유분무의 초기분산과정에 관한 실험적 연구)

  • 허종철;구자왕;양옥룡
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.13 no.2
    • /
    • pp.42-49
    • /
    • 1991
  • This study is to investigate the dispersion characteristics of diesel fuel spray in the initial stage of the beginning of the injection under the condition of room temperature and atmospheric pressure. It is difficult to analyse that the diesel fuel spray in diesel engine has unsteady intermittent spray. So author installed a fuel accumulator and an electromagnetic controller in order to keep the constant fuel injection rate with the time variation. With this modified fuel injection system, spray tip penetration, spray angle and initial spray development process are investigated by instantaneous photographic method. The results obtained in this study are as follows : 1) The initial shape of injection of diesel fuel spray shows the form of non-disintegrated intact core, but the formation of ligaments increasingly grows as the time increases. It can also be shown that fine droplets become disintegrated out from the ligaments. 2) The slope of spray tip penetration was changed to two different tendencies with time. The transition point of the slope is shown at the time of around between 0.09 msec and 0.4 msec from the beginning of injection. This is transition time from non-disintegrated intact core to formation of ligaments.

  • PDF

The Aerodynamic & Respiratory Muscle Pressure Aspects of Patients with Adductor Spasmodic Dysphonia (내전형 경련성발성장애의 호흡압력과 공기역학적 특징)

  • Nam, Do-Hyun;Choi, Seong-Hee;Choi, Jae-Nam;Choi, Hong-Shik
    • Speech Sciences
    • /
    • v.12 no.4
    • /
    • pp.203-213
    • /
    • 2005
  • This study was conducted to investigate the respiratory and aerodynamic function of adductor spasmodic dysphonia (ADSD) patients. Participants were (1) 18 females SD patients with non- Botulinum toxin injection (2) 14 females SD patients who had taken treatment of Botulinum toxin injection. (3) 14 age- and sex- matched normal female controls. Spirometer and phonatory function analyzer were used for respiratory muscle pressure (MIP: Maximum inspiratory pressure), MEP: Maximum expiratory pressure)& MPT(Maximum phonation time) and aerodynamic(F0:Fundamental frequency, intensity, MFR: Mean flow late, Psub: Subglottal pressure) measurement. The results were as follows: (1) Normal group was significantly higher in MIP, MEP, MPT than two SD groups (p < .05); (2) MPT was significantly lower in SD with non-Botulinum toxin injection group than SD with the treatment experience of Botulinum toxin injection (p < .05); (3) All aerodynamic parameters, F0, intensity, MFR, Psub, were not significantly different among three groups(p > .05).The reason of short MPT in ADSD may use lower respiratory pressure than normal group as strategy to decrease their tremulous voice quality. Moreover respiratory muscle pressure was lower than normal group regardless of botulinum toxin injection treatment.

  • PDF

A Study on the Improvement of Double Injection-molding Keypad Process (이중 사출 키패드 성형 공정 개선에 관한 연구)

  • Hong, Min-Sung;Lee, Ji-Hoon;Shin, Soo-Hyun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.5
    • /
    • pp.659-665
    • /
    • 2011
  • Recently, the plastic resin such as PC, ABS are widely used in IT market. Especially, in most cases the keypads mounted on the mobile phone are the dual-injection-plated type. Environmental regulation is based on the quality of injection-molded products and the minimum process steps are required to avoid the plating defects. Various parameters to produce the injection-molded plastic products make it difficult to obtain the desired stability. However, the past experience and the use of CAE analysis make it possible to predict the problems occurred in injection molding process. Especially, the problems of the weld lines such as runner balancing, bending, deformation and forming defects can be solved systematically and minimized by CAE analysis. Through this study, the non-uniform volumetric shrinkage and the difference in temperature distribution induce the deformation and the high value of stress causes the problems such as crack.

A Case of Vocal Cord Abscess after Injection Laryngoplasty (성대주입술 후 발생한 성대 내 농양 1례)

  • Yi, Jong-Sook;Kim, Ji-Won;Choi, Seung-Ho
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.21 no.2
    • /
    • pp.142-144
    • /
    • 2010
  • Unilateral vocal cord paralysis occurs from a dysfunction of the recurrent laryngeal nerve. It causes a characteristic hoarseness, shortness of breath and swallowing disability. Prompt injection laryngoplasty is a treatment options that aims to improve these symptoms less invasively and easily than any other procedures. Cross-linked hyaluronic acid (HA) is widely used injection material. It is non-mammalian polysaccharides derived from streptococcus strain and well known for its duration in vocal cord about 3-6 months after injection. However, there were no complication reports such as infection or rejection after HA injection laryngoplasty in previous report. We present a case of patient with laryngeal abscess after transcricothyroid membrane percutaneous HA injection laryngoplasty.

  • PDF

Effects of warmed carrier fluid on nefopam injection-induced pain

  • Cho, Hyung Rae;Kim, Seon Hwan;Kim, Jin A;Min, Jin Hye;Lee, Yong Kyung
    • The Korean Journal of Pain
    • /
    • v.31 no.2
    • /
    • pp.102-108
    • /
    • 2018
  • Background: Nefopam is a non-opioid, non-steroidal analgesic drug with fewer adverse effects than narcotic analgesics and nonsteroidal anti-inflammatory drugs, and is widely used for postoperative pain control. Because nefopam sometimes causes side effects such as nausea, vomiting, somnolence, hyperhidrosis and injection-related pain, manufacturers are advised to infuse it slowly, over a duration of 15 minutes. Nevertheless, pain at the injection site is very common. Therefore, we investigated the effect of warmed carrier fluid on nefopam injection-induced pain. Methods: A total of 48 patients were randomly selected and allocated to either a control or a warming group. Warming was performed by diluting 40 mg of nefopam in 100 ml of normal saline heated to $31-32^{\circ}C$ using two fluid warmers. The control group was administered 40 mg of nefopam dissolved in 100 ml of normal saline stored at room temperature ($21-22^{\circ}C$) through the fluid warmers, but the fluid warmers were not activated. Results: The pain intensity was lower in the warming group than in the control group (P < 0.001). The pain severity and tolerance measurements also showed statistically significant differences between groups (P < 0.001). In the analysis of vital signs before and after the injection, the mean blood pressure after the injection differed significantly between the groups (P = 0.005), but the heart rate did not. The incidence of hypertension also showed a significant difference between groups (P = 0.017). Conclusions: Use of warmed carrier fluid for nefopam injection decreased injection-induced pain compared to mildly cool carrier fluid.

The Numerical multi-phase analysis of ventilating flow around vehicle (환기 공동을 이용한 수중운동체 주위의 초월 공동 다상유동장 해석)

  • Park, Wam-Gyu;Kim, Dong-Hyun;Jung, Chul-Min
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.252-255
    • /
    • 2011
  • Supercavitating torpedo uses the supercavitation technology that can reduce dramatically the skin friction drag. The present work focuses on the numerical analysis of the non-condensable cavitating flow around the supercavitating torpedo. The governing equations are the Navier-Stokes equations based on the homogeneous mixture model. The cavitation model uses a new cavitation model which was developed by Merkle(2006). The multiphase flow solver uses an implicit preconditioning scheme in curvilinear coordinates. The ventilated cavitation is implemented by non-condensable gas injection on backward of cavitator cone and the base of the torpedo. The comparison between the without and with ventilated cavitation numerical results, with ventilated cavitation using non-condensable gas injection is more efficient method.

  • PDF

Evolution of particle acceleration and instabilities in galaxy cluster shocks

  • van Marle, Allard Jan;Ryu, Dongsu;Kang, Hyesung;Ha, Ji-Hoon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.42.2-43
    • /
    • 2018
  • When galaxy clusters interact, the intergalactic gas collides, forming shocks that are characterized by a low sonic Mach number (~3) but a comparatively high Alfvenic Mach number (~30). Such shocks behave differently from the more common astrophysical shocks, which tend to have higher sonic Mach numbers. We wish to determine whether these shocks, despite their low sonic Mach number, are capable of accelerating particles and thereby contributing to the cosmic ray spectrum. Using the PIC-MHD method, which separates the gas into a thermal and a non-thermal component to increase computational efficiency, and relying on existing PIC simulations to determine the rate at which non-thermal particles are injected in the shock, we investigate the evolution of galaxy cluster shocks and their ability to accelerate particles. Depending on the chosen injection fraction of non-thermal particles into the shock, we find that even low-Mach shocks are capable of accelerating particles. However, the interaction between supra-thermal particles and the local magnetic field triggers instabilities and turbulence in the magnetic field. This causes the shock to weaken, which in turn reduces the effectiveness of the supra-thermal particle injection. We investigate how this influences the shock evolution by reducing the particle injection rate and energy and find that a reduction of the particle injection fraction at this stage causes an immediate reduction of both upstream and downstream instabilities. This inhibits particle acceleration. Over time, as the instabilities fade, the shock surface straightens, allowing the shock to recover. Eventually, we would expect this to increase the efficiency of the particle injection and acceleration to previous levels, starting the same series of events in an ongoing cycle of increasing and decreasing particle acceleration.

  • PDF