• Title/Summary/Keyword: Non-injection

Search Result 1,058, Processing Time 0.029 seconds

Mechanism of Combustion Instability in Supersonic Combustor (초음속 연소기 내의 연소 불안정 메커니즘)

  • 최정열
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.191-194
    • /
    • 2003
  • A series of computational simulations have been carried out for non-reacting and reacting flows in a supersonic combustor configuration with and without a cavity. Transverse injection of hydrogen, a simplest form of fuel supply, is considered in the present study with the injection pressure of 0.5 and 1.0 ㎫. The corresponding equivalence ratios are 0.17 and 0.33. The work features detailed resolution of the flow and flame dynamics in the combustor, which was not typically available in most of the previous studies. In particular, oscillatory flow characteristics are captured at a scale sufficient to identify the underlying physical mechanisms. Much of the flow unsteadiness is related not only to the cavity, but also to the intrinsic unsteadiness in the flowfield. The interactions between the unsteady flow and flame evolution may cause a large excursion of flow oscillation. The role of the cavity, injection pressure, and amount of heat addition are examined systematically.

  • PDF

The Improvement of Weldline and Flow mark Defection by using Injection Molding Analysis (사출성형 해석을 통한 Weldline 및 Flow mark 개선사례)

  • Lee, Yeong Chang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.12
    • /
    • pp.1295-1301
    • /
    • 2013
  • The cause of flow mark defect is known as non-uniform temperature of mold surface when the flow front meets the cold cavity. The exact definition and classification of Flow mark is not clear because the mechanism of flow mark is not figured out till now. Any injection molding analysis software can not predict the flow mark phenomena. To solve weldline and flow mark defects, the gate thickness is reduced to increase the melt front velocity and the melt front velocity of the flow mark area is increased from 82.3mm/s to 104.7mm/s. In addition, the bulk temperature of the flow mark area is increased from $178.3^{\circ}C$to $215.2^{\circ}C$ by adding a cold slug well. The flow mark phenomena can be greatly reduced by increasing the flow front velocity and elevating the bulk temperature.

Experimental Investigation on Key Parameters in Air-powered Needle-free Injection System for Skin Treatment (피부 치료를 위한 공압식 무침 주사 시스템의 주요 인자에 관한 실험적 연구)

  • Kim, Jung Kyung;Mohizin, Abdul;Lee, Seung Ku
    • Journal of the Korean Society of Visualization
    • /
    • v.16 no.1
    • /
    • pp.42-47
    • /
    • 2018
  • A needle-free injector is one of the new non-invasive players in impregnating the biological barriers. It is considered as the next phase in drug delivery and therapeutic applications. One of the major fields of application is in skin remodeling procedures. Although many studies were carried out in understanding the principle in the needle-free injection procedure, fewer studies were done with the aim of therapeutic applications. In the present study, we tried to identify key parameters that affect the jet divergence and peak stagnation pressure on the skin surface in a conventional needle-free injector for skin treatment. A summary of the working principle and effect of the key parameters are presented.

Effect of Botulinum Toxin Injection on the Stuttering Patients (말더듬(Stuttering) 환자에 대한 보툴리눔독소의 주입 효과)

  • 최홍식;김영호;표화영;홍원표
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.8 no.2
    • /
    • pp.193-198
    • /
    • 1997
  • Stuttering is a movement disorder of speech-motor control characterized by inappropriate timing of lingual, labial, laryngeal, and respiratory muscles. Treatment for adult stutterers have included traditional and non-traditional behavioral and psychiatric modalities, many with good initial success but all with limited long-term benefit. Recent trials of botulinum toxin injection was somewhat favorable. In this study, the authors injected 5-8 U of botulinum toxin into the thyroarytenoid muscle bilaterally in cases of disabling stutterers. Evaluation after 4 weeks of injection, 80% of the patients was improved more than one positive scale. However, no one was improved to almostly normal range.

  • PDF

Localized Induction-Heating Method by the Use of Selective Mold Material (재료의 선택적 사용에 의한 금형의 국부적 유도가열기법)

  • Park, Keun;Do, Bum-Suk;Park, Jung-Min;Lee, Sang-Ik
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.168-171
    • /
    • 2009
  • High-frequency induction is an efficient way to heat mold surface by electromagnetic induction in a non-contact procedure. Though the induction heating has an advantage in terms of its rapid-heating capacity on the mold surface, it still has a restriction on mold temperature control due to geometric restriction of an induction coil according to the mold shape. It has been recently applied to the injection molding of thin-walled parts or micro/nano structures. For localized induction heating, an injection mold composed of ferromagnetic material and paramagnetic material is used. The electromagnetic induction concentrates on the ferromagnetic material, from which we can selectively heat for the local mold elements. The present study proposed a localized induction heating method by means of selective use of mold material. The feasibility of the proposed heating method is investigated through the comparison of experimental observations according to the mold material.

  • PDF

A Case of Nonthrombotic Pulmonary Embolism after Facial Injection of Hyaluronic Acid in an Illegal Cosmetic Procedure

  • Jang, Jong Geol;Hong, Kyung Soo;Choi, Eun Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.77 no.2
    • /
    • pp.90-93
    • /
    • 2014
  • Hyaluronic acid is widely used in medical procedures, particularly in cosmetic procedures administered by physicians or nonmedical personnel. The materials used for cosmetic procedures by physicians as well as illegally by non-medical personnel can cause nonthrombotic pulmonary embolism (NTPE). We report the case of a woman with acute respiratory failure, neurologic symptoms and petechiae after an illegal procedure of hyaluronic acid dermal filler performed by an unlicensed medical practitioner 3 days before symptom onset. Although a few cases of NTPE after injection of hyaluronic acid have been reported yet, this is the first typical case showing a NTPE manifestation after the facial injection of hyaluronic acid.

Simulation Study of Injection-Molded Light Guide Plates for Improving Luminance Uniformity Based on the Measured Replication Quality of Micro-Patterns for LED TV Backlight

  • Joo, Byung-Yun;Ko, Jae-Hyeon
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.2
    • /
    • pp.159-164
    • /
    • 2015
  • In the injection-molded light guide plate the replication quality, i.e. the reproduction accuracy, of micro-patterns should be high and uniform over the entire surface area. However technical difficulty in meeting the necessary replication quality arises as the plate size becomes large for TV applications. We propose a simulation technique to optimize the distribution of micro-patterns on a 55-inch injection molded light guide plate considering non-ideal replication quality of micro-patterns. The luminance uniformity could be improved by more than 16% by optimizing the pattern distribution in spite of the same replication quality.

Prediction of Weight of Spiral Molding Using Injection Molding Analysis and Machine Learning (사출성형 CAE와 머신러닝을 이용한 스파이럴 성형품의 중량 예측)

  • Bum-Soo Kim;Seong-Yeol Han
    • Design & Manufacturing
    • /
    • v.17 no.1
    • /
    • pp.27-32
    • /
    • 2023
  • In this paper, we intend to predict the mass of the spiral using CAE and machine learning. First, We generated 125 data for the experiment through a complete factor design of 3 factors and 5 levels. Next, the data were derived by performing a molding analysis through CAE, and the machine learning process was performed using a machine learning tool. To select the optimal model among the models learned using the learning data, accuracy was evaluated using RMSE. The evaluation results confirmed that the Support Vector Machine had a good predictive performance. To evaluate the predictive performance of the predictive model, We randomly generated 10 non-overlapping data within the existing injection molding condition level. We compared the CAE and support vector machine results by applying random data. As a result, good performance was confirmed with a MAPE value of 0.48%.

  • PDF

Effect of Abdominal Massage before In Vitro Fertilization Injection on Alleviating Pain among Infertile Women (난임여성의 주사 전 복부 마사지가 통증경감에 미치는 효과)

  • Ku, Ja Ock;Park, Young Joo;Kim, Jeong Wook;Jeon, Eun Joung;Jang, Jeong Hee;Cho, Young Hee;Cho, Hwa Yeun;Park, Jum Mi;Lee, Seung Shin
    • Women's Health Nursing
    • /
    • v.22 no.2
    • /
    • pp.78-85
    • /
    • 2016
  • Purpose: The purpose of this study was to evaluate the effect of abdominal massage on alleviating pain caused by the injection of recombinant gonadotropin for In Vitro Fertilization (IVF) among infertile women. Methods: This study employed a nonequivalent control group non-synchronized design. A total sample of 149 infertile women who never experienced in vitro fertilization was recruited at C fertility center. Seventy women were assigned into experimental group and 79 into controls. The experimental group had been informed to do abdominal massage prior to the injection and to record their subjective pain using visual analogue scale. The control group had been informed to record their subjective pain in the same way just after the injection. Results: Compared to the pre-tested pain scores, the pain scores in experimental group were significantly reduced by 0.7 points, whereas the control group increased by 0.9 points (t=-4.55, p=.001). Conclusion: This study confirms that the use of abdominal massage prior to the injection is an effective way to alleviate pain on injection site. This massage may be a useful intervention for infertile women about pain alleviation.

A Study on the Warpage in Injection Molded Part for Various Part Designs and Non Reinforced Resins (비 보강 수지의 종류와 사출성형품의 설계에 따른 휨의 연구)

  • Lee, M.;Kim, J.H.;Park, S.R.;Lyu, M.Y.
    • Elastomers and Composites
    • /
    • v.44 no.4
    • /
    • pp.373-377
    • /
    • 2009
  • Most of the plastics products are being manufactured by injection molding. Warpage in injection molded affects the product dimension and it causes assembling problem. In this study, warpages in the injection molded part been studied. Specimens are rectangular flat shapes with and without ribs. Amorphous polymers (PC and ABS) and crystalline polymers (PP and PA66) were used for material. Flat shape with ribs showed higher warpage than flat shape without ribs by 6 to 9%. The specimens with ribs that are located parallel to the flow direction has higher warpage than specimens with ribs that are located perpendicular to the flow direction by 25 to 39%. Crystalline polymers have higher warpage than amorphous polymers by 23 to 67%. Warpage decreases as packing time increases and it increases as injection temperature increases.