• 제목/요약/키워드: Non-fickian

검색결과 24건 처리시간 0.017초

Modeling Dynamics of Nonconservative Pollutants in Streams with Pools and Riffles

  • Seo, Il-Won;Yu, Dae-Young
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 1993년도 수공학연구발표회논문집
    • /
    • pp.175-182
    • /
    • 1993
  • The complex nature of low flow transport and tranformation of nonconservative pollutants in natural streams with pools and riffles has been investigated using a numerical solution of a proposed mathematical model that is based on a set of mass balance equations describing hydrodynamic processes (advection, dispersion, and mass exchange mechanicms in streams and in storage zones) and chemical processes (reaction or decay). In this study, a mathematical model (named "Storage-Transformation Model") has been developed to predict adequately the non-Fickian nature of mixing and transformation mechanisms for decaying substances in natural streams under low flow conditions. Comparisons between the concentration-time curves predicted usingthe proposed model and the measured stream data shows that the Storage-Transformation Model yields better agreements in the goneral shape, peak concentration and time to peak than the 1-D dispersion model. The result of this study also demonstrates the differences between transport in pool-and-riffle streams versus transport in more uniform channels. The proposed model shows significant improvement over the conventional 1-D disperision model in predicting natural mixing and stroage processes in streams through pools and riffles.

  • PDF

자연하천에서 비보존성 오염물질의 이동 및 변환 모의: 저장-변환 모형 (Simulation of Transport and Transformation of Nonconservative Pollutants in Natural Streams: Storage-Transformation Model)

  • 서일원;유대영
    • 대한토목학회논문집
    • /
    • 제14권4호
    • /
    • pp.867-874
    • /
    • 1994
  • 유량이 매우 작은 갈수기(渴水期)에 자연하천으로 방류된 비보존성 오염물질의 이동 및 화학적, 생화학적 변환과정의 복잡성을 구명하기 위해서 이송, 확산, 변환 그리고 하천수로에 존재하는 저장대(貯藏帶)에서 오염물질의 저장 및 교환과정을 규정하는 한 쌍의 방정식으로 이루어진 수학적 모형을 개발하고 이의 해를 수치해석적인 방법에 의해 구하였다. "저장-변환 모형"이라 명명된 본 수화적 모형은 갈수기(渴水期) 하천에서의 비보존성 오염물질의 혼합 및 변환 메카니즘의 비정규분포적인 특성을 보다 정확하게 예측할 수 있도록 개발되었다. 모형의 모의결과, 농도-시간곡선의 전체적인 형태, 첨두농도, 그리고 첨두농도에 도달하는 시간 등에 있어서 저장-변환 모형이 종래의 1차원 확산모형보다 실측자료에 더욱 정확하게 일치한다는 사실이 밝혀졌다. 본 연구에서 개발된 저장-변환 모형은 웅덩이-급여울 연속구조로 이루어진 하천에서의 오염물질의 이동 및 변환거동을 예측하는 모형으로서 1차원 확산모형에 비해 월등히 개선된 모형으로 밝혀졌다.

  • PDF

Monitoring the water absorption in GFRE pipes via an electrical capacitance sensors

  • Altabey, Wael A.;Noori, Mohammad
    • Advances in aircraft and spacecraft science
    • /
    • 제5권4호
    • /
    • pp.499-513
    • /
    • 2018
  • One of the major problems in glass fiber reinforced epoxy (GFRE) composite pipes is the durability under water absorption. This condition is generally recognized to cause degradations in strength and mechanical properties. Therefore, there is a need for an intelligent system for detecting the absorption rate and computing the mass of water absorption (M%) as a function of absorption time (t). The present work represents a new non-destructive evaluation (NDE) technique for detecting the water absorption rate by evaluating the dielectric properties of glass fiber and epoxy resin composite pipes subjected to internal hydrostatic pressure at room temperature. The variation in the dielectric signatures is employed to design an electrical capacitance sensor (ECS) with high sensitivity to detect such defects. ECS consists of twelve electrodes mounted on the outer surface of the pipe. Radius-electrode ratio is defined as the ratio of inner and outer radius of pipe. A finite element (FE) simulation model is developed to measure the capacitance values and node potential distribution of ECS electrodes on the basis of water absorption rate in the pipe material as a function of absorption time. The arrangements for positioning12-electrode sensor parameters such as capacitance, capacitance change and change rate of capacitance are analyzed by ANSYS and MATLAB to plot the mass of water absorption curve against absorption time (t). An analytical model based on a Fickian diffusion model is conducted to predict the saturation level of water absorption ($M_S$) from the obtained mass of water absorption curve. The FE results are in excellent agreement with the analytical results and experimental results available in the literature, thus, validating the accuracy and reliability of the proposed expert system.

Analysis of activated colloidal crud in advanced and modular reactor under pump coastdown with kinetic corrosion

  • Khurram Mehboob;Yahya A. Al-Zahrani
    • Nuclear Engineering and Technology
    • /
    • 제54권12호
    • /
    • pp.4571-4584
    • /
    • 2022
  • The analysis of rapid flow transients in Reactor Coolant Pumps (RCP) is essential for a reactor safety study. An accurate and precise analysis of the RCP coastdown is necessary for the reactor design. The coastdown of RCP affects the coolant temperature and the colloidal crud in the primary coolant. A realistic and kinetic model has been used to investigate the behavior of activated colloidal crud in the primary coolant and steam generator that solves the pump speed analytically. The analytic solution of the non-dimensional flow rate has been determined by the energy ratio β. The kinetic energy of the coolant fluid and the kinetic energy stored in the rotating parts of a pump are two essential parameters in the form of β. Under normal operation, the pump's speed and moment of inertia are constant. However, in a coastdown situation, kinetic damping in the interval has been implemented. A dynamic model ACCP-SMART has been developed for System Integrated Modular and Advanced Reactor (SMART) to investigate the corrosion due to activated colloidal crud. The Fickian diffusion model has been implemented as the reference corrosion model for the constituent component of the primary loop of the SMART reactor. The activated colloidal crud activity in the primary coolant and steam generator of the SMART reactor has been studied for different equilibrium corrosion rates, linear increase in corrosion rate, and dynamic RCP coastdown situation energy ratio b. The coolant specific activity of SMART reactor equilibrium corrosion (4.0 mg s-1) has been found 9.63×10-3 µCi cm-3, 3.53×10-3 µC cm-3, 2.39×10-2 µC cm-3, 8.10×10-3 µC cm-3, 6.77× 10-3 µC cm-3, 4.95×10-4 µC cm-3, 1.19×10-3 µC cm-3, and 7.87×10-4 µC cm-3 for 24Na, 54Mn, 56Mn, 59Fe, 58Co, 60Co, 99Mo, and 51Cr which are 14.95%, 5.48%, 37.08%, 12.57%, 10.51%, 0.77%, 18.50%, and 0.12% respectively. For linear and exponential coastdown with a constant corrosion rate, the total coolant and steam generator activity approaches a higher saturation value than the normal values. The coolant and steam generator activity changes considerably with kinetic corrosion rate, equilibrium corrosion, growth of corrosion rate (ΔC/Δt), and RCP coastdown situations. The effect of the RCP coastdown on the specific activity of the steam generators is smeared by linearly rising corrosion rates, equilibrium corrosion, and rapid coasting down of the RCP. However, the time taken to reach the saturation activity is also influenced by the slope of corrosion rate, coastdown situation, equilibrium corrosion rate, and energy ratio β.