• Title/Summary/Keyword: Non-contact Sensor

Search Result 294, Processing Time 0.022 seconds

Evaluation of Micro End-Milling Characteristics of AlN-hBN Composites Sintered by Hot-Pressing (열간가압소결에 의해 제조된 AlN-hBN 복합재료의 마이크로 엔드밀링 가공특성 평가)

  • Baek, Si-Young;Cho, Myeong-Woo;Seo, Tae-Il
    • Korean Journal of Metals and Materials
    • /
    • v.46 no.6
    • /
    • pp.390-401
    • /
    • 2008
  • The objective of this study is to evaluate various machining characteristics of AlN-hBN machinable ceramics in micro end-milling process for its further application. First, AlN based machinable ceramics with hBN contents in the range of 10 to 20vol% were prepared by hot-pressing. Material properties of the composites, such as relative density, Vickers hardness, flexural strength, Young's modulus and fracture toughness were measured and compared. Then, micro end-milling experiments were performed to fabricate micro channels using prepared system. During the process, cutting forces, vibrations and AE signals were measured and analyzed using applied sensor system. Machined micro channel shapes and surface roughness were measured using 3D non-contact type surface profiler. From the experimental results, it can be observed that the cutting forces, vibrations and AE signal amplitudes decreased with increasing hBN contents. Also, measured surface roughness and profiles were improved with increasing hBN contents. As a result of this study, optimum machining conditions can be determined to fabricate desired products with AlN-hBN machinable ceramics based on the experimental results of this research.

In situ Stress Measurements with Submonolayer Sensitivity As a Probe of Coherent-to-incoherent Matching at an Interface in Ultrathin Magnetic Films

  • Jeong, Jong-Ryul;Kim, Young-Seok;Shin, Sung-Chul
    • Journal of Magnetics
    • /
    • v.7 no.4
    • /
    • pp.151-155
    • /
    • 2002
  • In situ stress changes at interfaces of ultrathin magnetic films were measured by means of a non-contact optical fiber bundle displacement detector. A bending of the substrate due to stress of a deposited film was detected in cantilever geometry. The highest sensitivity of 134 mV/$\mu$m for the displacement detector was realized with a help of computer simulation. The detector was applied to in situ stress measurements of Co/Pt and Ni/Pd magnetic multilayer films prepared on the glass substrates by dc magnetron sputtering. The detector turned out to have a submonolayer sensitivity that enables to observe coherent-to-incoherent transition in these mismatched multilayers and even detect the stress changes within the monoatomic coverage. This highly sensitive detector paves new way to probe the stress relaxation at an interface in ultrathin films.

Development of Multi-DoF Automatic Nasopharyngeal Swab Sampling Robot (다자유도 비강 자동 검체 채취 로봇 메커니즘 개발)

  • Jongbok Lee;Hobin Kim;Sunwoo Kim;Sangdo Kim;Hoseok Lee;Yong-Jae Kim;Shinsuk Park;Jongwon Lee
    • The Journal of Korea Robotics Society
    • /
    • v.18 no.2
    • /
    • pp.164-171
    • /
    • 2023
  • To control the spread of COVID-19, it is important to identify the infection in its incipient stages so that the infected persons can be dealt with accordingly. The currently used face to face sampling method may increase the risk of infection for medical professionals as it exposes them to the asymptomatic yet infectious patients. This can result in further increases in the load on the medical system and workload of the medical staff. As a solution to this problem, in this paper, we present a robotic system for rapid non-face-to-face automatic nasopharyngeal swab sample collection. The system consists of a custom designed 7-DoF manipulator equipped with a specially developed safety mechanism for restricting the maximum force applied by the tip of the swab. During the swab sampling process, the force applied by the tip of the swab is continuously monitored in real-time by a 3-axis force sensor in order to detect contact with the nasopharynx. The possibility of using this system for automaticnasopharyngeal swab sample collection is proven through experimentation with a phantom model.

Development of the Power Monitoring System for the Planetary Geared Motor using Hall Effect Sensor (홀 이펙트 센서를 이용한 유성기어 감속기모터의 동력 모니터링 시스템 개발)

  • Jang, In-Hun;Sim, Kwee-Bo;Oh, Se-Hoon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.14 no.7
    • /
    • pp.914-919
    • /
    • 2004
  • When the motor is rotating, the torque and rpm are varying as the loads or the driving status connecting through reduction units are changing. On the contrary, one can monitor the changes of the loads or the driving status in the manner of measuring motor torque and rpm. There is a torque measuring method using the strain gauge and bridge circuit. But, because this is the contact method, it has the life time which is dependent on rotating velocity and used time. So this system demands on replacement of some Parts or whole system itself for maintenance. And this system is also relatively big and expensive, requiring preceding annoying process. In this paper, we are going to suppose non-contact method to measure torque and rpm using the Hall effects sensor For this we have made the planetary geared reduction motor with Hall sensors and with the monitoring system. The monitoring system displays the sensing data(torque, rpm) and calculated data( power) and also has the network capability with Bluetooth protocol. Our solution is much more inexpensive ;md simple method to measure torque and rpm than before.

Measurement of two-dimensional vibration and calibration using the low-cost machine vision camera (저가의 머신 비전 카메라를 이용한 2차원 진동의 측정 및 교정)

  • Kim, Seo Woo;Ih, Jeong-Guon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.2
    • /
    • pp.99-109
    • /
    • 2018
  • The precision of the vibration-sensors, contact or non-contact types, is usually satisfactory for the practical measurement applications, but a sensor is confined to the measurement of a point or a direction. Although the precision and frequency span of the low-cost camera are inferior to these sensors, it has the merits in the cost and in the capability of simultaneous measurement of a large vibrating area. Furthermore, a camera can measure multi-degrees-of-freedom of a vibrating object simultaneously. In this study, the calibration method and the dynamic characteristics of the low-cost machine vision camera as a sensor are studied with a demonstrating example of the two-dimensional vibration of a cantilever beam. The planar image of the camera shot reveals two rectilinear and one rotational motion. The rectilinear vibration motion of a single point is first measured using a camera and the camera is experimentally calibrated by calculating error referencing the LDV (Laser Doppler Vibrometer) measurement. Then, by measuring the motion of multiple points at once, the rotational vibration motion and the whole vibration motion of the cantilever beam are measured. The whole vibration motion of the cantilever beam is analyzed both in time and frequency domain.

Using Air-coupled Sensors (ASC) for Non-contact Non-destructive Evaluation of Concrete in Structures (Air-coupled 센서를 이용한 비접촉 콘크리트 비파괴 검사법)

  • Kee, Seong Hoon
    • Magazine of the Korea Institute for Structural Maintenance and Inspection
    • /
    • v.17 no.1
    • /
    • pp.48-59
    • /
    • 2013
  • 응력파의 기반한 비파괴 검사법은 비교적 실험 절차 및 실험에 필요한 장비가 단순하고, 인체에 해가 없으며, 비용이 저렴한 특성을 갖고있다. 따라서 건축/토목 구조물의 비파괴 검사에 매우 효과적인 방법으로 알려져 있다. 하지만 기존의 가속도계, 변위계, 지오폰과 같은 부착 센서를 사용할 경우 표면 처리, 센서의 부착 및 이동에 따른 추가적인 시간이 소요되고, 센서와 구조물의 불완전한 커플링으로 인한 측정 결과의 신뢰성 및 일관성을 유지하지 어렵다는 문제를 발생시킨다. 최근 이러한 문제의 해결책으로 Air-coupled sensor (ACS)의 사용이 각광받고 있으며, 여러 연구자들에 의해 ACS의 가능성 및 실용성이 증명되고 있다. 기존의 접촉센서와 비교하여 ACS를 사용했을 때 얻을 수 있는 가장 큰 장점은 센서의 커플링 문제를 근본적으로 해결하여 신뢰도가 높고 일관적인 측정이 가능하고, 대형 건축/토목 구조물의 표면을 음향스캔하여 결과를 신속하게 처리하여 실시간으로 시각화 할 수 있다는 점이다. 이론적으로 ACS를 이용하여 측정하는 물리값은 콘크리트 내부에서 발생된 응력파의 일부가 공기중으로 전파된 누설파 (Leaky wave)이다. 콘크리트 비파괴 검사에 주로 사용하는 100 kHz이하의 저주파를 측정할 경우 일반적으로 콘텐서마이크가 ACS로 사용될 수 있다. 기존 연구자들은 실험 및 이론적 연구를 통하여 응력파에 기반한 비파괴 방법에서 ACS가 기존의 접촉 센서를 대체할 수 있다는 점을 보여주고 있다. 현재 미국에서는 연방 도로청 (FHWA) 및 국가표준기술연구소 (NIST)의 연구비 지원으로 ACS의 실용성을 높이기 위하여 최적화된 음향반사판의 설계를 통한 ACS 의 민감도를 높이기 위한 연구, 다채널 센서 배열 및 데이터 통합을 위한 새로운 알로리즘 개발, 자동화 및 로봇 기술과 융합과 같은 연구가 활발히 진행되고 있다. 멀지 않은 미래에는 ACS를 장착한 무인 로봇이 다양한 종류의 건축/토목 구조물의 건전도를 평가하기 위하여 종횡무진 활약하는 모습을 현실 속에서 볼 수 있을 것이라 기대한다.

  • PDF

Online correction of drift in structural identification using artificial white noise observations and an unscented Kalman Filter

  • Chatzi, Eleni N.;Fuggini, Clemente
    • Smart Structures and Systems
    • /
    • v.16 no.2
    • /
    • pp.295-328
    • /
    • 2015
  • In recent years the monitoring of structural behavior through acquisition of vibrational data has become common practice. In addition, recent advances in sensor development have made the collection of diverse dynamic information feasible. Other than the commonly collected acceleration information, Global Position System (GPS) receivers and non-contact, optical techniques have also allowed for the synchronous collection of highly accurate displacement data. The fusion of this heterogeneous information is crucial for the successful monitoring and control of structural systems especially when aiming at real-time estimation. This task is not a straightforward one as measurements are inevitably corrupted with some percentage of noise, often leading to imprecise estimation. Quite commonly, the presence of noise in acceleration signals results in drifting estimates of displacement states, as a result of numerical integration. In this study, a new approach based on a time domain identification method, namely the Unscented Kalman Filter (UKF), is proposed for correcting the "drift effect" in displacement or rotation estimates in an online manner, i.e., on the fly as data is attained. The method relies on the introduction of artificial white noise (WN) observations into the filter equations, which is shown to achieve an online correction of the drift issue, thus yielding highly accurate motion data. The proposed approach is demonstrated for two cases; firstly, the illustrative example of a single degree of freedom linear oscillator is examined, where availability of acceleration measurements is exclusively assumed. Secondly, a field inspired implementation is presented for the torsional identification of a tall tower structure, where acceleration measurements are obtained at a high sampling rate and non-collocated GPS displacement measurements are assumed available at a lower sampling rate. A multi-rate Kalman Filter is incorporated into the analysis in order to successfully fuse data sampled at different rates.

Estimation of Moisture Content in Comminuted Miscanthus based on the Intensity of Reflected Light

  • Cho, Yongjin;Lee, Dong Hoon
    • Journal of Biosystems Engineering
    • /
    • v.40 no.3
    • /
    • pp.296-304
    • /
    • 2015
  • Purpose: The balance between miscanthus production and its cost effectiveness depends greatly on its moisture content during post processing. The objective of this research was to measure the moisture content using a non-destructive and non-contact methodology for in situ applications. Methods: The moisture content of comminuted miscanthus was controlled using a closed chamber, a humidifier, a precision weigher, and a real-time monitoring software developed in this research. A CMOS sensor equipped with $50{\times}$ magnifier lens was used to capture magnified images of the conditioned materials with moisture content level from 5 to 30%. The hypothesis is that when light is incident on the comminuted particles in an inclined manner, higher moisture content results in light being reflected with a higher intensity. Results: A linear regression analysis for an initiative hypothesis based on general histogram analysis yielded insufficient correlations with low significance level (<0.31) for the determination coefficient. A significant relationship (94% confidence level) was determined at level 108 in a reverse accumulative histogram proposed based on a revised hypothesis. A linear regression model with the value at level 108 in the reverse accumulative histogram for a magnified image as the independent variable and the moisture content of comminuted miscanthus as the dependent variable was proposed as the estimation model. The calibrated linear regression model with a slope of 92.054 and an offset of 32.752 yielded 0.94 for the determination coefficient (RMSE = 0.2%). The validation test showed a significant relationship at the 74% confidence level with RMSE 6.4% (n = 36). Conclusions: To compensate the inconsistent significance between calibration and validation, an estimation model robust against various systematic interferences is necessary. The economic efficiency of miscanthus, which is a promising energy resource, can be improved by the real-time measurement of its crucial material properties.

Development of Automatic Peach Grading System using NIR Spectroscopy

  • Lee, Kang-J.;Choi, Kyu H.;Choi, Dong S.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1267-1267
    • /
    • 2001
  • The existing fruit sorter has the method of tilting tray and extracting fruits by the action of solenoid or springs. In peaches, the most sort processing is supported by man because the sorter make fatal damage to peaches. In order to sustain commodity and quality of peach non-destructive, non-contact and real time based sorter was needed. This study was performed to develop peach sorter using near-infrared spectroscopy in real time and nondestructively. The prototype was developed to decrease internal and external damage of peach caused by the sorter, which had a way of extracting tray with it. To decrease positioning error of measuring sugar contents in peaches, fiber optic with two direction diverged was developed and attached to the prototype. The program for sorting and operating the prototype was developed using visual basic 6.0 language to measure several quality index such as chlorophyll, some defect, sugar contents. The all sorting result was saved to return farmers for being index of good quality production. Using the prototype, program and MLR(multiple linear regression) model, it was possible to estimate sugar content of peaches with the determination coefficient of 0.71 and SEC of 0.42bx using 16 wavelengths. The developed MLR model had determination coefficient of 0.69, and SEP of 0.49bx, it was better result than single point measurement of 1999's. The peach sweetness grading system based on NIR reflectance method, which consists of photodiode-array sensor, quartz-halogen lamp and fiber optic diverged two bundles for transmitting the light and detecting the reflected light, was developed and evaluated. It was possible to predict the soluble solid contents of peaches in real time and nondestructively using the system which had the accuracy of 91 percentage and the capacity of 7,200 peaches per an hour for grading 2 classes by sugar contents. Draining is one of important factors for production peaches having good qualities. The reason why one farm's product belows others could be estimated for bad draining, over-much nitrogen fertilizer, soil characteristics, etc. After this, the report saved by the peach grading system will have to be good materials to farmers for production high quality peaches. They could share the result or compare with others and diagnose their cultural practice.

  • PDF

Effect of Simulator Sickness Caused by Head-mounted Display on the Stability of the Pupillary Rhythm (머리착용 디스플레이에 의해 유발된 멀미 증상이 동공 리듬의 안정성에 미치는 영향)

  • Park, Sangin;Lee, Don Won;Mun, Sungchul;Kim, Hong-Ik;Whang, Mincheol
    • Science of Emotion and Sensibility
    • /
    • v.21 no.4
    • /
    • pp.43-54
    • /
    • 2018
  • The aim of this study is to determine the effect of motion sickness on pupil rhythm. Sixteen volunteers of both genders (8 male, 8 female, mean age $25.67{\pm}2.43$ years) experienced VR contents in both 2D and HMD versions for 15 minutes, and their pupillary rhythms were compared. The irregular pattern of the pupillary rhythms, as demonstrated by increasing mean pupil diameter (mPD) and standard deviation of the pupil diameter (sPD), revealed motion sickness after experiencing HMD condition. The pupillary response is strongly related to the cognitive load, and the motion sickness can be interpreted as a change in the cognitive load caused by the increasing volume of visual information that must be processed and the conflict or inconsistency between different sensory modalities. The method proposed in this study could be a non-contact measurement method for the monitoring of motion sickness using a web-camera rather than previous sensor-based methods.