• Title/Summary/Keyword: Non-contact Method

Search Result 837, Processing Time 0.028 seconds

Implementation of Non-contact Plant Growth Measurement System based on USN Technologies (USN 기술 기반의 비접촉 식물 생장 측정 시스템 구현)

  • Suk, Jin-Weon;Ryoo, In-Tae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.10
    • /
    • pp.137-145
    • /
    • 2010
  • This paper is proposed non-contact plant growth measurement system using infrared sensor based on USN(Ubiquitous Sensor Network) technologies. The proposed system has used noncontact sensors to reduce any potential damage when it measures the growth of the plant. In this system, plant growth parameters such as diameter, cross-sectional area and thickening form are measured in real-time non-contact method. The measured data are transmitted to remote server by using sensor network technologies, stored and analyzed at the server, and the analyzed data are finally provided for users. In this paper, the proposed plant growth measurement system has been designed and implemented using non-contact infrared sensor based measurement methods and devices, and its performances have been verified by actual measurement experiments at the fields.

The study of non-contact/non-invasive pulse analyzing system using Optical Coherence Tomography (OCT) for oriental pulse diagnosis (비접촉식 광생체단층촬영 기술을 이용한 맥진 연구 -맥의 빠르기, 크기 및 맥력을 중심으로-)

  • Na, Chang-Su;Youn, Dae-Hwan;Kim, Young-Sun;Lee, Chang-Ho;Jung, Woon-Sang;Kim, Jee-Hyun;Choi, Chan-Hun
    • Korean Journal of Acupuncture
    • /
    • v.26 no.2
    • /
    • pp.1-13
    • /
    • 2009
  • Objective: Optical Coherence Tomography (OCT) has emerged as an important optical imaging modality in non-invasive medical diagnostics. Hence, the aim of this study is to measure the similarity of the diagnosis by a traditional method using doctor's hand for feeling of pulse and by the non-contact/non-invasive pulse analyzing system using OCT on Chon(寸), Kwan(關), Chuk(尺). Method: Four korean medical doctors and the non-contact/non-invasive pulse analyzing system using OCT have measured the rapidity, the dimension, and the power of pulse waves of 25 volunteers. First, four korean medical doctors measured pulse waves of volunteers. During measuring, four doctors were separated from each other and so were volunteers. And then, the pulse waves of volunteers were measured by OCT. This was performed on the right Chon(寸), Kwan(關), Chuk(尺). Results: The study showed that the traditional method and the OCT based method had the 88% matches on the values of the slow and rapid pulse condition (遲數), 64% matches on the values of the small and big pulse condition(微細弱緩大[洪]), and 72% matches on the values of the weak and strong pulse condition(虛實). Conclusions: Based on the high similarities of the measurements of two approaches, we suggest that the OCT based pulse diagnosis method is useful for compensating the traditional method for the pulse diagnosis.

  • PDF

A Study on the Measurement of the 3-D Object Shapes by Using Optical Ring Method (광링식 3차원 형상 측정법에 관한 연구)

  • Kang, Young-June;Park, Jeong-Hwan;Kim, Dong-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.9
    • /
    • pp.38-45
    • /
    • 1996
  • The optical triangulation method has been used as a non-contact measuring method of three dimensional object whape. But this measuring method has narrow measuring range, non-linearity on steep slope surface and shadow effect. In this study, we discussed a new optical measurement method to overcome these kinds of demerits. The advantage of this new method is that it is possible to measure precisely the object shape having the steep slope surface without shadow effect. As exper- imental results, maximum displacement error was 200 .mu. m over the whole measuring when the incident angle on the object surface was within 60 degree.

  • PDF

A Study on the Development of Measuring System for Extra Long Roller Using Non-contact Sensor (비접촉식 센서를 이용한 초장축 롤러 측정 장치 개발에 관한 연구)

  • Kim, Woong;Lee, Choon-Man;Lee, Mun-Jae;Park, Sung-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.4
    • /
    • pp.33-39
    • /
    • 2010
  • Manufacturing accuracy of a precision instrument was essential to stability and efficiency of the product. Accordingly, geometrically accuracy management of precision instrument was very becoming the technique in order to design and manufacturing for machine. In this study, Measuring System is developed for extra long roller using non-contact sensor. Futhermore, It's studied by Geometric Tolerance. Exact roundness is obtained to Least Squares method from the reference circle of measured data. Measuring System is analyzed point of measurement and straightness of extra long roller is evaluated by FEM.

The Strain Measurement of Pure Aluminum Welded Zone by the Laser System (레이저 계측에 의한 순알루미늄 용접부의 스트레인 측정)

  • 성백섭;차용훈;이연신
    • Journal of Welding and Joining
    • /
    • v.20 no.2
    • /
    • pp.71-76
    • /
    • 2002
  • Currently knowledge of strain in welds has mainly been obtained from strain gage method; that is directly attaching the gage to the most of the material. The very flew non-contact methods are still in the early stage. One of the non-contact methods is by the use of the laser that has high-level of the accuracy for the measurement, and this laser also has excellent characteristics on which many studies for its applications are focused throughout the many fields. The paper is on the measurement of the strain caused by the characteristics and the temperature changes of the GTA welded zone employed with 3D ESPI system that is functionally modified through the laser ESPI system. This system may be applied the steel plate such as for the electronics, chemistry, flood instrument and electronic appliances.

Non-Contact Measurement of Elastic Waves Propagating in a Rotating Shaft using Magnetostrictive Effects (자왜 현상을 이용한 회전축 내부의 비접촉 탄성파 측정)

  • 한순우;이호철;김윤영
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.365-370
    • /
    • 2001
  • The purpose of this work is to suggest a new non-contact measurement method applicable to the diagnosis of rotating shafts. Longitudinal elastic waves propagating along the shafts are measured by magnetostrictive sensors that make use of the coupling phenomena between strains and magnetic induction in ferromagnetic shafts. These sensors have been successfully applied in pipes and others, but it appears that the present application of them to rotating shafts is made here for the first time. Several isssues appearing in the present application are carefully investigated and several experimental results are presented to address the usefulness of the present method.

  • PDF

Experimental Evaluation of HDD's Non-Contact Start/Stop Motion Using Shape Memory Alloy Actuator (SMA 작동기를 이용한 HDD의 비접촉 시동 및 정지 기구의 실험적 성능 고찰)

  • 임수철;박종성;최승복;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.1122-1129
    • /
    • 2001
  • In this work, we propose a new type of HDD suspension featuring shape memory ally (SMA) actuator in order to prevent the contact between the slider and disk. The principal design parameters are obtained from the modal analysis using finite element analysis, and then the dynamic model is established to formulate the control scheme for Non-Contact Start/Stop mode drive. Subsequently, a robust Η$_{\infty}$, control algorithm is designed by integrating experimentally-obtained SMA actuator dynamics to the proposed suspension system. The controller is empirically realized and control results for different load/unload profiles are presented in time domain. In addition, the contact signal between the slider and disk is measured by the electrical resistance method.istance method.

  • PDF

Contactless feed-back control method through power stage transformer in non-contact battery charger (무접점 충전기의 전력단 변압기를 통한 무접점 피드백 제어방식)

  • 김창균
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.258-261
    • /
    • 2000
  • A non-contact battery charger which transfers energy using magnetic field has a difficulty with a feed-back control due to the interaction between the power and signal processing This paper proposes an effective method which uses auxiliary windings of transformer as signal path and copes with cross-talk using the MOSFET ringing phenomenon and ceramic filter. The power stage is half-bridge series resonant converter. Design procedure and experimental verification are presented.

  • PDF

Facile preparation of superhydrophobic thin films using non-aligned carbon nanotubes

  • Goh, Yee-Miin;Han, Kok Deng;Tan, Lling-Lling;Chai, Siang-Piao
    • Advances in nano research
    • /
    • v.2 no.4
    • /
    • pp.219-225
    • /
    • 2014
  • A simple preparation method on creating superhydrophobic surface using non-aligned carbon nanotubes (CNTs) was demonstrated. Superhydrophobic CNT thin films were prepared by doping a sonicated mixture of CNTs and chloroform onto a glass slide. Water contact angles of the CNT thin films were measured using a contact angle goniometer. The thin films were characterized using laser microscope and scanning electron microscope. Experimental results revealed that the highest average contact angle of $162{\pm}2^{\circ}$ was achieved when the films' thickness was $1.628{\mu}m$. The superhydrophobic surface was stable as the contact angle only receded from $162{\pm}2$ to $157{\pm}2^{\circ}$ after 10 min under normal atmospheric condition.

Research on the Non-Contact Detection of Internal Defects in a Rail Using Ultrasonic Waves (비접촉 초음파 방식의 철도레일 내부결함 검출에 관한 연구)

  • Han, Soon-Woo;Cho, Seung-Hyun;Kim, Joon-Woo;Heo, Tae-Hoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.10
    • /
    • pp.1010-1019
    • /
    • 2012
  • Non-contact detection of internal defects in a rail using ultrasonic waves is discussed in this paper. Cracks in a rail may be the cause of a serious railway accident such as derailment if left undetected. Concurrent rail inspection method based on ultrasonic testing using piezoelectric transducers has several limitations as it should keep physical contact with the rail. This work suggests a non-contact detection of internal defects in a rail using ElectroMagnetic Acoustic Transducers (EMAT) which can produce and measure ultrasonic waves in a rail without any couplant. The EMATs for rail inspection are designed and fabricated and their working performance is verified through a series of experiments on various types of internal defects in test rails. The effect of lift-off between the transducers and the rail on the generated signals is also discussed.