• Title/Summary/Keyword: Non-conformity

Search Result 108, Processing Time 0.024 seconds

Selection of radiation treatment plan technique at breast cancer operating technique (유방암 수술기법에 따른 방사선치료계획 기법의 선택)

  • Kim, Jeong-Ho;Bae, Seok-Hwan;Kim, Ki-Jin;Yoo, Se-Jong
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.1
    • /
    • pp.125-130
    • /
    • 2015
  • Techniques, using physical wedge filter and using dynamic wedge filter and FIF(Field in Field) and ISCT(Irregular Surface Compensating Technique), have been developed according to progress of radiation therapy of breast cancer. Measurement of dose was done to judge the usefulness of technique using three cases, non tissue loss after breast conserving operating and tissue loss after breast conserving operating and mastectomy. Dose indexes of breast tissue, CI (Conformity Index), HI (Homogeneity Index) and QOC (Quality of Coverage), dose index of skin, or dose indexes of lung, volume of 50 percent dose and 20 percent dose were estimated and compared. Using dynamic wedge filter is useful plan at non tissue loss allowing for high dose of lung. FIF and ISCT are useful plan at tissue loss. ISCT is useful plan at mastectomy. Henceforth, we need to apply to valid plan and body type and thorax size.

Finite element simulation of sheet metal forming by using non-parametric tool description with locally refined patches (국소 분할된 패치를 갖는 비매개변수 금형묘사법을 이용한 3차원 박판성형공정해석)

  • 윤정환;양동열;유동진
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1995.03a
    • /
    • pp.162-169
    • /
    • 1995
  • An improved nonparametric tool description based on successive refined monparametric patches is proposed and therlated criterion for refinement is also discussed . In the proposed sheme, any required order of tool surface conformity can be achieved by employing successive refinements accoring to the suggested criterion. By using the suggested adaptive tool refinement technique based on the nonparametric patch tool description, the locally refined nonparametric tool surface with economic memory size and sufficient accuracy as well as with favorable charateristics for contact treatment can be obtained directly form the parametric patch related with commerical CAD system. Computation is carried out for a chosen complex sheet forming example of an actual autobody panel in order to verify the validity and the efficiency of the developed tool surface description.

  • PDF

The Study of Symbolic Images in Modern Fashion Design adopting the Dualistic Meanings of Uniform (유니폼의 양면성을 도입한 현대 패션디자인의 상징적 이미지에 대한 연구)

  • Kwon, Gi-Young
    • Fashion & Textile Research Journal
    • /
    • v.13 no.4
    • /
    • pp.478-486
    • /
    • 2011
  • This study is to analyze the symbolic images appeared in modern fashion design adopted dualistic meanings in uniforms. Uniforms signify order, conformity and discipline in public life. The dualistic meanings in uniforms appeared modern times are as follows: public authority vs individual non-authority, heterosexual identity vs homosexual identity, time-space uniformity vs mixed diversity. The symbolic images appeared in modern fashion design adopted dualistic meanings in uniforms such as military uniforms, school uniforms, nurses' uniforms, sports uniforms and etc. are erotic image, hybrid image, and kitsch image.

The development of a variable capacitive pressure sensor for TPMS(tire pressure monitoring system) (TPMS 적용을 위한 가변 정전 용량형 압력센서 개발)

  • Choi, Bum-Koo;Kim, Do-Hyung;Oh, Jae-Geun
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.265-271
    • /
    • 2005
  • In this study, a variable capacitive pressure sensor is fabricated for TPMS (Tire Pressure Monitoring System). This study is for developing sensors which consecutively measure the tire pressure given as 30 psi from the industrial standard. For improving non-linearity of the prior capacitive pressure sensors, it is suggested that touch mode capacitive pressure sensor be applied. In addition, initial capacitance is designed as small as possible for the conformity to the wireless sensor. ANSYS, commercial FEA package, is used for designing and simulating the sensor. The device is progressed by MEMS (Micro Electro Mechanical Systems) fabrication and packaged with PDMS. The result is obtained sensitivity, 1 pF/psi, through a pressure test. The simulation result is discrepant from experiment one. Wafer's uniformity is presumed as the main reason of discrepancy.

Finite Element Simulation of Sheet Metal Forming by Using Non-parametric Tool Description with Locally Refined Patches (국소 분할된 패치를 갖는 비매개변수 금형묘사법을 이용한 3차원 박판성형공정 시뮬 레이션)

  • 윤정환;양동열;유동진
    • Transactions of Materials Processing
    • /
    • v.5 no.1
    • /
    • pp.47-54
    • /
    • 1996
  • An improved nonparametric tool description based on successive refined nonparametric patches is proposed and the related criterion for refinement is also discussed. In the proposed scheme any required order of tool surface conformity can be achieved by employing successive refinements according to the suggested criterion. By using the suggested adaptive tool refinement technique based on the nonparametric patch tool description the locally refined nonparametric tool surface with economic memory size and sufficient accuracy as well as with favorable characteristics for contact treatment can be obtained directly from the parametric patch related with commercial CAD system. Computation is carried out for a chosen complex sheet forming example of an actual autobody panel in order to verify the validity and the efficiency of the developed tool surface description.

  • PDF

Dosimetric comparison of coplanar and non-coplanar volumetric-modulated arc therapy in head and neck cancer treated with radiotherapy

  • Gayen, Sanjib;Kombathula, Sri Harsha;Manna, Sumanta;Varshney, Sonal;Pareek, Puneet
    • Radiation Oncology Journal
    • /
    • v.38 no.2
    • /
    • pp.138-147
    • /
    • 2020
  • Purpose: To evaluate the dosimetric variations in patients of head and neck cancer treated with definitive or adjuvant radiotherapy using optimized non-coplanar (ncVMAT) beams with coplanar (cVMAT) beams using volumetric arc therapy. Materials and Methods: Twenty-two patients of head and neck cancer that had received radiotherapy using VMAT in our department were retrospectively analyzed. Each of the patients was planned using coplanar and non-coplanar orientations using an optimized couch angle and fluences. We analyzed the Conformity Index (CIRTOG), Dose Homogeneity Index (DHI), Heterogeneity Index (HIRTOG), low dose volume, target and organs-at-risk coverage in both the plans without changing planning optimization parameters. Results: The prescription dose ranged from 60 Gy to 70 Gy. Using ncVMAT, CIRTOG, DHI and HIRTOG, and tumor coverage (ID95%) had improved, low dose spillage volume in the body V5Gy was increased and V10Gy was reduced. Integral dose and intensity-modulated radiation therapy factor had increased in ncVMAT. In the case of non-coplanar beam arrangements, maximum dose (Dmax) of right and left humeral head were reduced significantly whereas apex of the right and left lung mean dose were increased. Conclusion: The use of ncVMAT produced better target coverage and sparing of the shoulder and soft tissue of the neck as well as the critical organ compared with the cVMAT in patients of head and neck malignancy.

Efficacy of ISO 9001 : 2000 Quality Management System in Human Assisted Reproductive Technology Center (보조생식술 센터에서 ISO 9001 : 2000 품질경영시스템의 도입 및 시행의 효용성)

  • Jun, Jin-Hyun;Park, Yong-Seog;Lee, Hyoung-Song;Kim, Soon-Duk;Hwang, Son-Hee;Han, Su-Kyoung;Kim, Jae-Ho;Song, In-Ok;Kang, Inn-Soo;Koong, Mi-Kyoung
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.34 no.2
    • /
    • pp.107-115
    • /
    • 2007
  • Objective: A quality management system of international standardization organization (ISO) 9001:2000 has been proposed to properly evaluate and improve the quality of productions and services. The purpose of this article was to describe on successful introduction and application of the ISO system to human assisted reproductive technology (ART) center. Methods: Center for reproductive medicine and infertility of Cheil General Hospital started the action for ISO 9001:2000 certification at January-2004. The ISO system of our center was monitored by measuring the customer satisfaction index and periodical internal and external audit. Reports of non-conformity described corrective and preventive actions for problems and occurrences that were not consistent with the standard process and operation of our center. Continuous management and improvement were performed on the project of customer dissatisfaction. Results: Our center has got the certification of ISO 9001:2000 for "Research and development of IVF-ET program for infertility treatment" from Korean Foundation for Quality at June-2004. The policy of ISO was "To establish the best center of reproductive medicine and infertility" and "To establish the best quality management system". We found 140 cases and 7 cases of non-conformity in internal and external audit for three years, respectively, and performed corrective action. Conclusion: Improvement of customer satisfaction, systemic documentation and transparency and efficacy of working procedure were achieved by application and operation of the ISO system to our center. This ISO system could be used as a basic institutional management system for the national guideline to the human ART center.

The Effect of Power Type within Supply Chain on the Information Capability: Perspective of CSV Value Creation (공급사슬 내의 파워유형이 정보역량에 미치는 영향: CSV 가치창출 관점)

  • Park, Kwang-O;Chang, Hwal-Sik;Jung, Dae-Hyun
    • The Journal of Information Systems
    • /
    • v.27 no.3
    • /
    • pp.1-24
    • /
    • 2018
  • Purpose The purpose of this study is to attempt to incorporate power theory to evaluate information capability of SCM adopters. Therefore, this study focuses on the relationship of information sharing, partnership quality, and information capacity according to the power intensity of the variables of SCM. and CSV value creation. Design/methodology/approach The questionnaire of SCM builder was conducted and 302 samples were analyzed. Based on the theoretical background of power and information capacity, we set up a structural equation model. Hypothesis testing and statistical analysis were done through AMOS and SPSS. Findings First, it shows that the compensation power among the constrained power has a positive effect on the partnership quality, and the legitimacy power has the positive influence only on the information sharing. Compulsive power, compensation, and legitimacy, which are generally restrictive powers, may reduce the quality of information sharing and partnership, but the results of this study are rather higher. Second, both non-binding power expertise and criterion have a positive effect on information sharing and partnership quality. Third, information sharing has a positive effect on partnership quality. Supporting a number of research results, it is well reflected in SCM attributes where interdependence is important. Fourth, information sharing and partnership quality have a positive effect on information capacity. Information literacy has become an essential element in modern management. Fifth, the enhancement of CSV value creation plays a role of a controlling variable to further strengthen information sharing through non - binding power attribute, expertise and conformity. In addition, the strengthening of CSV value creation has been shown to play a role as a controlling variable to further strengthen the quality of partnership through the non-binding power attribution, but expertise has been rejected.

Radiotherapy for gastric mucosa-associated lymphoid tissue lymphoma: dosimetric comparison and risk assessment of solid secondary cancer

  • Bae, Sun Hyun;Kim, Dong Wook;Kim, Mi-Sook;Shin, Myung-Hee;Park, Hee Chul;Lim, Do Hoon
    • Radiation Oncology Journal
    • /
    • v.35 no.1
    • /
    • pp.78-89
    • /
    • 2017
  • Purpose: To determine the optimal radiotherapy technique for gastric mucosa-associated lymphoid tissue lymphoma (MALToma), we compared the dosimetric parameters and the risk of solid secondary cancer from scattered doses among anterior-posterior/ posterior-anterior parallel-opposed fields (AP/PA), anterior, posterior, right, and left lateral fields (4_field), 3-dimensional conformal radiotherapy (3D-CRT) using noncoplanar beams, and intensity-modulated radiotherapy composed of 7 coplanar beams (IMRT_co) and 7 coplanar and noncoplanar beams (IMRT_non). Materials and Methods: We retrospectively generated 5 planning techniques for 5 patients with gastric MALToma. Homogeneity index (HI), conformity index (CI), and mean doses of the kidney and liver were calculated from the dose-volume histograms. Applied the Biological Effects of Ionizing Radiation VII report to scattered doses, the lifetime attributable risk (LAR) was calculated to estimate the risk of solid secondary cancer. Results: The best value of CI was obtained with IMRT, although the HI varied among patients. The mean kidney dose was the highest with AP/PA, followed by 4_field, 3D-CRT, IMRT_co, and IMRT_non. On the other hand, the mean liver dose was the highest with 4_field and the lowest with AP/PA. Compared with 4_field, the LAR for 3D-CRT decreased except the lungs, and the LAR for IMRT_co and IMRT_non increased except the lungs. However, the absolute differences were much lower than <1%. Conclusion: Tailored RT techniques seem to be beneficial because it could achieve adjacent organ sparing with very small and clinically irrelevant increase of secondary solid cancer risk compared to the conventional techniques.

Fire resistance evaluation of fiber-reinforced cement composites using cellulose nanocrystals

  • Lee, Hyung-Joo;Kim, Seung-Ki;Lee, Heon-Seok;Kang, Yong-Hak;Kim, Woosuk;Kang, Thomas H.K.
    • Advances in concrete construction
    • /
    • v.8 no.4
    • /
    • pp.311-320
    • /
    • 2019
  • In this study, the effect of cellulose nanocrystals (CNCs) on the fire resistance properties of fiber-reinforced cement composites was investigated. The main variables were CNCs content (0.4, 0.8 and 1.2vol.% compared with cement), steel fiber ratio, and exposure temperature (100, 200, 400, 600 and 800℃). The fire resistance properties, i.e., residual compressive strength, flexural strength, and porosity, were evaluated in relation with the exposure temperature of the specimens. The CNCs suspensions were prepared to composited dispersion method of magnetic stirring and ultra-sonication. CNCs are effective for increasing the compressive strength at high temperatures but CNCs do not seem to have a significant effect on flexural reinforcement. Porosity test result showed CNCs reduce the non-hydration area inside the cement and promote hydration.