• 제목/요약/키워드: Non-Isolation

검색결과 549건 처리시간 0.026초

Semi-active storey isolation system employing MRE isolator with parameter identification based on NSGA-II with DCD

  • Gu, Xiaoyu;Yu, Yang;Li, Jianchun;Li, Yancheng;Alamdari, Mehrisadat Makki
    • Earthquakes and Structures
    • /
    • 제11권6호
    • /
    • pp.1101-1121
    • /
    • 2016
  • Base isolation, one of the popular seismic protection approaches proven to be effective in practical applications, has been widely applied worldwide during the past few decades. As the techniques mature, it has been recognised that, the biggest issue faced in base isolation technique is the challenge of great base displacement demand, which leads to the potential of overturning of the structure, instability and permanent damage of the isolators. Meanwhile, drain, ventilation and regular maintenance at the base isolation level are quite difficult and rather time- and fund- consuming, especially in the highly populated areas. To address these challenges, a number of efforts have been dedicated to propose new isolation systems, including segmental building, additional storey isolation (ASI) and mid-storey isolation system, etc. However, such techniques have their own flaws, among which whipping effect is the most obvious one. Moreover, due to their inherent passive nature, all these techniques, including traditional base isolation system, show incapability to cope with the unpredictable and diverse nature of earthquakes. The solution for the aforementioned challenge is to develop an innovative vibration isolation system to realise variable structural stiffness to maximise the adaptability and controllability of the system. Recently, advances on the development of an adaptive magneto-rheological elastomer (MRE) vibration isolator has enlightened the development of adaptive base isolation systems due to its ability to alter stiffness by changing applied electrical current. In this study, an innovative semi-active storey isolation system inserting such novel MRE isolators between each floor is proposed. The stiffness of each level in the proposed isolation system can thus be changed according to characteristics of the MRE isolators. Non-dominated sorting genetic algorithm type II (NSGA-II) with dynamic crowding distance (DCD) is utilised for the optimisation of the parameters at isolation level in the system. Extensive comparative simulation studies have been conducted using 5-storey benchmark model to evaluate the performance of the proposed isolation system under different earthquake excitations. Simulation results compare the seismic responses of bare building, building with passive controlled MRE base isolation system, building with passive-controlled MRE storey isolation system and building with optimised storey isolation system.

등대구조물의 면진시스템 적용방안 연구 (Application of Isolation System to the Lighthouse Structure)

  • 허무원;천영수;김동영
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권1호
    • /
    • pp.27-36
    • /
    • 2013
  • 본 연구에서는 등대 구조물을 대상으로 한 면진기술 적용방안을 제시함으로써 지진에 대해 무방비상태에 놓여 있는 등대구조물의 지진안전도 확보방안을 제시하였다. 또한, 제안된 면진기술 적용방안을 활용하여 내진설계 이전에 지어진 등대를 대상으로 등대전체를 면진하였을 경우와 등대 렌즈만을 면진하였을 경우에 대하여 면진효과를 분석해 보았다. 해석결과, 등대 전체를 면진화하였을 경우 최대응답가속도와 층전단력 측면에서 충분한 면진효과를 얻은 반면, 등대 렌즈만을 면진화한 경우에는 렌즈부의 면진효과는 유효한 것으로 나타났으나 등대 자체의 안전이 확보되지 못한 상황에서는 등대의 파괴가 선행될 가능성이 있음에 주의할 필요가 있는 것으로 나타났다. 또한 등대전체와 렌즈를 동시에 면진화한 경우 비 면진구조 대비 유효한 면진효과는 나타내었지만, 최대응답가속도가 등대전체를 면진화한 경우보다 증가하는 경향을 나타내었으며, 렌즈의 면진화로 인한 층전단력의 감소가 미소함으로 이중면진의 적용으로 인한 실효성은 그 효과가 크지 않은 것으로 나타났다.

긴급치료격리병동의 평면유형 (A study on the Types of Urgent Isolation Ward)

  • 이현진;권순정
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제28권4호
    • /
    • pp.61-69
    • /
    • 2022
  • Purpose: In response to the rapid spread of COVID-19 in 2020, the government supported facilities and equipment through the 'Urgent Isolation Ward Expansion Project'. Design and remodeling of efficient negative pressure isolation facilities had to be done in a short period of time, and the performance gap between facilities was very large because the types of hospitals and wards of existing medical facilities were diverse. In order to secure the stability of isolation wards between medical facilities and reduce the facility gap, guidelines for planning isolation wards considering the diversity of each hospital should be appropriately presented. In consideration of these points, this study aims to provide basic data for future remodeling guidelines for each plan type of the negative pressure isolation ward first. Methods: We analyzed the plans before and after the change of 13 case hospitals that performed the urgent care bed expansion project for COVID-19 confirmed patients. Before the remodeling, the current status of the facility was analyzed according to the type of corridor, the location of the nursing station, and the location of the elevator. After remodeling, the flow of medical staff and patients, the flow of entry and exit of clean and contaminated items, and the space of negative pressure and non-negative pressure areas. Results: The ward type was divided into three types according to the corridor type and room arrangement: double loaded corridor type with two side wards, race track type with one side ward, and race track type with two side wards. Based on these three types, the standard floor plan type of the isolation ward was proposed in terms of the location of the elevator bank and Nurse station. Implications: When the existing general ward is converted into a negative pressure isolation ward, this study can be a basic data to present customized guidelines for each ward type.

면진층을 가지는 1/10 축소된 15층 무량판 아파트건물의 진동대 실험 (Shaking Table Test of a 1/10 Scale Isolated Fifteen-story Flat Plate Apartment Building)

  • 천영수
    • 토지주택연구
    • /
    • 제2권3호
    • /
    • pp.287-297
    • /
    • 2011
  • 본 논문은 적층고무형베어링을 갖는 15층 면진 무량판 아파트건물의 내진거동을 진동대실험을 통하여 검증한 결과를 제시하고 있다. 진동대실험은 중국의 CABR에서 1/10규모의 모형실험체를 대상으로 수행되었다. 실험의 진행은 4개의 지진파를 이용하여 X, Y, X+Y방향으로 다양한 크기의 지진동이 입력되었다. 실험결과, 비 면진건물은 중진레벨에서 진동주기가 현저히 감소하고, 비선형적인 거동을 보였으며, 가속도가 건물의 높이에 따라 현저하게 증가하고, 층간변위도 허용한계를 넘는 거동을 보였다. 반면, 면진건물은 중진레벨에서 거의 일정한 진동주기의 탄성적인 거동을 나타내었으며, 지진하중과 층 가속도가 현저하게 감소하는 응답을 나타내었다. 또한 면진층의 변위는 허용범위 내에서 거동하고, 층간변위는 무시할 수 있을 만큼 작은 강체거동을 나타내었다. 결론적으로 면진은 건물에 대한 지진의 영향을 감소시키는데 매우 효과적이며, 층 가속도의 감소를 통하여 사용성을 증가시키고, 건물 내 설비 등을 안전하게 보호할 수 있음이 입증되었다.

다목적 유전자 알고리즘을 이용한 퍼지제어기의 설계 (Design of Fuzzy Controller using Multi-objective Genetic Algorithm)

  • 김현수;;이동근
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.209-216
    • /
    • 2005
  • The controller that can control the smart base isolation system consisting of M damper and friction pendulum systems(FPS) is developed in this study. A fuzzy logic controller (FLC) is used to modulate the M damper force because the FLC has an inherent robustness and ability to handle non-linearities and uncertainties. A genetic algorithm (GA) is used for optimization of the FLC. When earthquake excitations are applied to the structures equipped with smart base isolation system, the relative displacement at the isolation level as well as the acceleration of the structure should be regulated under appropriate level. Thus, NSGA-II(Non-dominated Sorting Genetic Algorithm) is employed in this study as a multi-objective genetic algorithm to meet more than two control objectives, simultaneously. NSGA-II is used to determine appropriate fuzzy control rules as well to adjust parameters of the membership functions. Effectiveness of the proposed method for optimal design of the FLC is judged based on computed responses to several historical earthquakes. It has been shown that the proposed method can efficiently find Pareto optimal sets that can reduce both structural acceleration and base drift from numerical studies.

  • PDF

Stochastic responses of isolated bridge with triple concave friction pendulum bearing under spatially varying ground motion

  • Yurdakul, Muhammet;Ates, Sevket
    • Structural Engineering and Mechanics
    • /
    • 제65권6호
    • /
    • pp.771-784
    • /
    • 2018
  • This study aims to investigate the stochastic response of isolated and non-isolated highway bridges subjected to spatially varying earthquake ground motion model. This model includes wave passage, incoherence and site response effects. The wave passage effect is examined by using various wave velocities. The incoherency effect is investigated by considering the Harichandran and Vanmarcke coherency model. The site response effect is considered by selecting homogeneous firm, medium and soft soil types where the bridge supports are constructed. The ground motion is described by power spectral density function and applied to each support point. Triple concave friction pendulum (TCFP) bearing which is more effective than other seismic isolation systems is used for seismic isolation. To implement seismic isolation procedure, TCFP bearing devices are placed at each of the support points of the deck. In the analysis, the bridge selected is a five-span featuring cast-in-place concrete box girder superstructure supported on reinforced concrete columns. Foundation supported highway bridge is regarded as three regions and compared its different situation in the stochastic analysis. The stochastic analyses results show that spatially varying ground motion has important effects on the stochastic response of the isolated and non-isolated bridges as long span structures.

A Study on Characterization and Modeling of Shallow Trench Isolation in Oxide Chemical Mechanical Polishing

  • Kim, Sang-Yong;Chung, Hun-Sang
    • Transactions on Electrical and Electronic Materials
    • /
    • 제2권3호
    • /
    • pp.24-27
    • /
    • 2001
  • The end point of oxide chemical mechanical polishing (CMP) have determined by polishing time calculated from removal rate and target thickness of oxide. This study is about control of oxide removal amounts on the shallow trench isolation (STI) patterned wafers using removal rate and thickness of blanket (non-patterned) wafers. At first, it was investigated the removal properties of PETEOS blanket wafers, and then it was compared with the removal properties and the planarization (step height) as a function of polishing time of the specific STI patterned wafers. We found that there is a relationship between the oxide removal amounts of blanket and patterned wafers. We analyzed this relationship, and the post CMP thickness of patterned wafers could be controlled by removal rate and removal target thickness of blanket wafers. As the result of correlation analysis, we confirmed that there was the strong correlation between patterned and blanket wafer (correlation factor: 0.7109). So, we could confirm the repeatability as applying for STI CMP process from the obtained linear formula. As the result of repeatability test, the differences of calculated polishing time and actual polishing time was about 3.48 seconds. If this time is converted into the thickness, then it is from 104 $\AA$ to 167 $\AA$. It is possible to be ignored because process margin is about 1800 $\AA$.

  • PDF

Urinary Catecholamine and Cortisol Responses of Japanese Shorthorn Cows to Social Isolation

  • Higashiyama, Yumi;Nashiki, M.;Narita, H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제22권10호
    • /
    • pp.1437-1440
    • /
    • 2009
  • This study was performed to investigate the use of urinary catecholamines to monitor changes in the activity of the sympathetic nervous system and to determine the relationship of urinary cortisol and catecholamines in Japanese Shorthorn cows in response to social isolation. One cow was isolated from its group, which consisted of 14 cows (457 to 756 kg BW, 2 to 12 years old), for three days. The isolated cow was in contact with the other cows visually only at meal times. This isolation was repeated for 6 cows. Spontaneously voided urine samples were collected from the experimental animals once a day, before the treatment and on days 1, 2, and 3. Urinary cortisol and adrenaline levels were significantly increased compared with pre-isolation levels on the first day, and then declined to the basal levels during the next two days. Urinary noradrenaline levels changed in the same way as cortisol and adrenaline levels, but the difference was not significant. Urinary cortisol levels tended to be correlated with those of urinary adrenaline, but not noradrenaline. This study suggests that the urinary adrenaline levels can be a non-invasive indicator of stress and that the change of urinary adrenaline is similar to that of urinary cortisol.

복지회관 이용 노인의 사회적 고립감 예측요인 (Factors Associated with Social Isolation in Older Adults using Senior Welfare Centers)

  • 박연환;강희선
    • 대한간호학회지
    • /
    • 제38권5호
    • /
    • pp.712-719
    • /
    • 2008
  • Purpose: The purpose of this study was to investigate the factors associated with social isolation in older adults using a senior welfare center. Methods: This study was a cross-sectional survey. Data was collected from June to August 2006 using a questionnaire. A total of 248 older adults responded. Results: About one third (34.9%) of participants responded they felt socially isolated. There were statistically significant differences in living, religion, family and belongingness social support, loneliness, depression, family function, perceived health status, and number of chronic illnesses between socially isolated and non isolated groups. However, factors influencing social isolation were family function (OR=0.954, CI=0.926-0.982), loneliness (OR=1.042, CI=1.002-1.083), depression (OR=1.041, CI=1.002-1.081), and number of chronic illness (OR=1.657, CI=1.153-2.382). Conclusion: We found that some older adults were feeling socially isolated even though the senior welfare center was a good place to meet people. The findings of this study indicated that older adults suffering from social isolation need special attention and may benefit from interventions which promote health and social interactions. Further studies are needed to develop and evaluate an intervention program for this population.