• Title/Summary/Keyword: Non-Heating Type

Search Result 77, Processing Time 0.023 seconds

Application Effect of Heating Energy Saving Package on Venlo Type Glasshouse of Paprika Cultivation (파프리카 재배 벤로형 유리온실에서 난방에너지 절감 패키지 기술 적용효과)

  • Kwon, Jin Kyung;Jeon, Jong Gil;Kim, Seung Hee;Kim, Hyung Gweon
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.225-231
    • /
    • 2016
  • Glasshouse heating package technologies to improve energy usage efficiency in winter were developed. Heating package was composed of the ground water source heat pump with heating capacity of 105kW, the aluminum multi-layer thermal curtain with six layers of different materials and the root zone local heater with XL pipes of ${\phi}20mm$. Venlo type glasshouse($461m^2$) with the heating package was compared with the same type and area control glasshouse with the light oil boiler, the usual non-woven fabric thermal curtain with respect to the glasshouse inside temperature, relative humidity, crop growth, and heating energy consumption. The results of test in paprika cultivation glasshouses showed that the air temperature inside glasshouse with aluminum multi-layer thermal curtain was maintained $2.2^{\circ}C$ higher than that of control glasshouse in un-heating night time and the temperature in bed with root zone local heating was $4.7^{\circ}C$ higher than that in bed without local heating. Average heating coefficient of performance(COP) of the ground water source heat pump used in paprika cultivation was 3.7 and the glasshouse inside temperature was maintained at $21^{\circ}C$ of heating set up temperature. The heating energy consumptions per 10a were measured at 14,071L of light oil and 364kWh of electric power for the control glasshouse and 35,082kWh for the glasshouse applied heating package. As results, the heating cost of the glasshouse applied heating package was 87 percent lower than that of control glasshouse. The growths of paprika in glasshouses of control and applied heating package did not show any significant difference.

Effect of Operating Conditions of a Fan-Coil Unit with an Oval Tube Type Heat Exchanger on Non-Dimensional Performance Coefficient (타원관 열교환기를 적용한 팬코일 유닛의 운전 조건이 무차원 성능계수에 미치는 영향)

  • Yoon, Jaedong;Lee, Younghoon;Sung, Jaeyong
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2019
  • In this study, the effect of operating conditions of fan-coil unit with an oval tube type heat exchanger on its non-dimensional performance coefficient has been investigated. Pressure drops and heat transfer rates were measured under heating condition for various water flow rates, inlet temperatures and wind speeds. As a non-dimensional performance coefficient, Colburn j-factor was evaluated. The results show that the most sensitive parameter on heat flux is the inlet temperature, which affects the heat flux 4.7 and 7.2 times more than the wind speed and water flow rate, respectively. On the other hand, the Colburn j-factor as a non-dimensionalized index decreases with the wind speed, and has an maximum when the wind speed is about 1 m/s. the Colburn j-factor increases slowly with the water flow rate and inlet temperature but at a certain range of inlet temperature, the opposite phenomenon is found.

Estimation of Surplus Solar Energy in Greenhouse (I) - Case Study Based on 1-2W Type - (온실내 잉여 태양에너지 산정 (I) - 1-2W형을 중심으로 -)

  • Suh, Won-Myung;Bae, Yong-Han;Ryou, Young-Sun;Lee, Sung-Hyoun;Yoon, Yong-Cheol
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.5
    • /
    • pp.79-86
    • /
    • 2009
  • This research performed to analyze surplus solar energy, which is generated from a greenhouse during daytime, and to make the basic materials for designing thermal energy storage system for surplus solar energy. For this goal, it analyzed the surplus solar energy coming from two types of greenhouse. The results of this research are as per the below: In the case of 1-2W-type greenhouse, this research gave the same temperature and ventilation condition regardless of regions, but it was judged that the quantity of surplus solar energy could be greatly changed, depending on the energy consumed for the photosynthesis and evapotranspiration of crops in the greenhouse, on the heating temperature during daytime and night, on the existence/non-existence of a curtain and its warming effect, and on the ventilation temperature suitable for the overcoming of high temperature troubles or for the optimum cultivation temperature. In the case of a single-span greenhouse, there was a big difference in energy incoming and outgoing by month, but throughout seasons, 85.0 % of the total energy put into the greenhouse was solar energy and the energy input by heating was just 15.0 % of the total. 26.4 % of the total energy input for the greenhouse was used for photosynthesis and evapotranspiration of crops, and 44.2 % of the remaining 73.6 % went out in the form of radiant heat through the surface of the greenhouse. That is, 25.2 % of the total energy loss was just the surplus solar energy. 67.6 % of the total heating energy was concentrically used for 3 months from December to February next year, but the surplus solar energy during the same period was just 19.4 % of the total annual quantity so it was found that the given condition was more restrictive in directly converting the surplus heat into greenhouse heating. Under the disadvantageous circumstance of 3 months from December to February next year, it was possible to supplement 28 % (December) $\sim$ 85 % (February) of heating energy with surplus solar energy.

Analysis on Heating Effects of the Vertical Type Geothermal Heat Pump System

  • Kang, Youn Ku;Ryou, Young Sun;Jang, Jae Kyung;Kim, Young Hwa
    • Journal of Biosystems Engineering
    • /
    • v.39 no.2
    • /
    • pp.69-75
    • /
    • 2014
  • Purpose: This paper is aimed at analyzing the heating performance of the vertical closed loop type Geothermal Heat Pump System (GHPS) distributing the farm site and providing basic data of the GHPS. Method: Seedling greenhouse heating was made from October 2012 to May 2013. The seedling greenhouse was divided into 4 sectors (A, B, C and D zone, total $3,300m^2$) with different temperatures. It was heated from 5PM to 8AM, and during the night the greenhouse was covered by non-woven fabric thermal curtains along the upper 2m of the greenhouse for temperature maintenance. In order to analyze the heating performance of the GHPS, power consumption and operating time of the GHPS, inlet and outlet water temperature of the condenser, temperatures of each zone of the greenhouse, and ambient temperature were measured. Results: When operating only one heat pump unit, heat generated in the condenser decreased as the experiment progressed and power consumption increased correspondingly. However, the heating coefficient of performance decreased from 3.3 to 2.0 rapidly. Also, when operating two heat pump units, heat generated in the condenser decreased and power consumption increased. Heating coefficient of performance decreased from 4.5 to 3.7 rapidly. When the set temperature of the greenhouse was $13.7{\sim}20.1^{\circ}C$ and minimum ambient temperature was $-20.8{\sim}4.8^{\circ}C$, the annually accumulated heat and power consumption were 520,623 kW, 142,304 kW, respectively. Conclusion: When the set temperature of the greenhouse was $13.7{\sim}20.1^{\circ}C$ and the minimum ambient temperature was $20.8{\sim}4.8^{\circ}C$, the annually accumulated heat and power consumption were 520,623 kW, 142,304 kW, respectively. When operating only one heat pump unit, the heating COP was 2.0~3.3, and when operating 2 heat pump units, it was 3.7~4.5. If several heat pumps are installed in one GHPS, it is suggested that all heat pumps be operated except in special cases. Because the scale of the water pumps are set to the scale of when all heat pump units are operating, if even one unit is not operating, the power consumption will increase. That becomes the cause of COP decrease.

An Analysis on Thermal Performance and Economic of Heat Recovery Ventilation System Integrated with Window (창호통합형 배열회수 환기시스템의 열성능 및 경제성 평가)

  • Sung, Uk-Joo;Cho, Soo;Song, Kyoo-Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.8
    • /
    • pp.646-655
    • /
    • 2012
  • This study is intended to analyze the thermal performance and evaluate the applicability about non-duct type heat recovery ventilation system integrated with window. Eventually, economic analysis of the system is conducted according to building energy saving ratio of it. As results of the thermal performance, the U-factor of the window conducted on the basis of KS F 2278 appears to $1.8W/m^2K$, and the effective heat exchange efficiency of the ventilator conducted on the basis of KS B 6879 appears 49.95% for cooling, 66.89% for heating. In the applicability evaluated by TRNSYS 16, the caes of applying the heat recovery ventilator integrated with window is found to reduce the cooling or heating load by 2.9% or 13.5% than the non-ventilator case. The results of economic analysis taking a side of consumer is verified as the payback is 3 years, and the accumulated earning is 1,408,133 won in terms of '600,000 won/unit' for initial cost, 10 years for useful life of the system.

Recent Studies on the Chemical Constituents of Korean Ginseng (Panax ginseng C. A. Meyer) (고려인삼의 화학성분에 관한 고찰)

  • 박종대
    • Journal of Ginseng Research
    • /
    • v.20 no.4
    • /
    • pp.389-415
    • /
    • 1996
  • Panax ginseng C.A. Meyer(Araliaceae) has been traditionally used as an expensive and precious medicine in oriental countries for more than 5, 000 years. Ginseng saponin isolated from the root of Panax ginseng have been regarded as the main effective components responsible for the pharmacological and biological activities. Such as antiaging effects. antidiabetic effects anticancer effects. Protection against physical and chemical stress. Analgesic and antipyretic effects. Effects on the central nervous system, tranquilizing action and others. Thirty kinds of ginsenosides have been so far isolated from ginseng saponin and their chemical structures have been elucidated since 1960's. Among which protopanaxadiol type is 19 kinds. protopanaxatriol type. 10 kinds and oleanane type, one. Since ginsenosides are generally labile under acidic conditions ordinary acid hydrolysis is always accompanied by many side reactions, such as epimerization. hydroxylation and cyclization of side chain of the sapogenins Especially. it is well known that C-20 glycosyl linkage of ginsenoside was hydrolysed on heating with acetic acid to give an equilibrated mixture of 20(S) and 20(R) epimers. And also, the chemical transformations of the secondary metabolites have appeared during the steaming process to prepare red ginseng. Indicating demalonylation of malonyl ginsenosides, elimination of glycosyl residue at C-20 and isomerization of hydroxyl configuration at C-20. But these studies have not provided a comprehensive picture in explaning how these ginsenosides showed val'iotas pharmacological activities of ginseng. Though some of them have been involved in the mechanism of pharmacological actions. Recently, non-saponin components have received a great deal of attention for their antioxidant, anticancer antidiabetic, immunomodulating. anticomplementary activities and so on. To meet the demand for such wide applications, studies on the non-saponin components play an important role in providing a good evidence of pharmacological and biol ogical activities. Among the non-saponin constituents of Korean ginseng, polyacetylenes, phenols. Sesquiterpenes, alkaloids. polysaccharides oligosaccharides, oligopeptides and aminoglycosides together with ginsenosides of terrestrial part are mainly described.

  • PDF

DECOMPOSITION OF HIGHER ORGANIC COMPOUND IN AN ATMOSPHERIC PRESSURE NON-EQUILIBRIUM PLASMA

  • Kitokawa, Kazutoshi;Itou, Akihito;Sugiyama, Kazuo
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.5
    • /
    • pp.593-598
    • /
    • 1996
  • Previously, in trying to prepare perovskite type oxide powders by microwave heating, we found out a non-equilibrium argon plasma is generated around the powders and discharge continues stable at atmospheric pressure. In this study, we tried the plasma decomposition of heat-stable higher organic compound such as palmitic acid which is the principal constituent of the fimger fats. It was proved that suitable amount of coexistence of oxygen radicals into the argon flow accelerates the decomposition of palmitic acid. The argon-oxygen mixed gas plasma was able to perform a complete elimination of higher organic compound.

  • PDF

Synthesis and Liquid Crystalline Properties of the Compounds Consisting of a Schiff Base Type Mesogen and a Dyad Type Aromatic Ester Structure Interconnected Through the Central Hexamethylene Spacer

  • Jung-Il Jin;Hyo-Seok Kim;Jin-Wook Shin;Bong Young Chung;Byung-Wook Jo
    • Bulletin of the Korean Chemical Society
    • /
    • v.11 no.3
    • /
    • pp.209-214
    • /
    • 1990
  • A series of compounds consisting of 4'-oxybenzylidene-4-n-butylaniline, a mesogen, and a p-substituted phenoxyterephthaloyl structure a non-mesogen, interconnected through a central hexamethylene spacer were synthesized and their thermal behavior and liquid crystallinity were studied. p-Substituents included in this study are H, Cl, CN, $NO_2,\;n-C_4H_9O$ and phenyl groups. The compounds having phenyl and $n-C_4H_9O$ substituents are enantiotropic and form smectic-A(SA) and nematic (N) phases. The compound with $NO_2$ substituent is monotropic and forms only a nematic phase on heating the solid, whereas it forms nematic as well as $S_A$ phases on cooling the isotropic liquid. The rest compounds were found to be non-liquid crystalline. This is in great contrast to the fact that the monomesogenic model compound 4'-n-hexyloxybenzylidine-4-n-butylaniline forms $S_B,\;S_C,\;S_A$ and N phases enantiotropically.

Thermal environment analysis of greenhouse using Thermo-tracer (Thermo-tracer를 이용한 온실의 열환경 분석)

  • 이석건;이종원;이현우;김란숙
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.230-236
    • /
    • 1998
  • Thermal environment of greenhouse was investigated by thermo-tracer in this study. The Thermo-tracer is a high-sensitivity infrared thermometer of non-contact type. The infrared energy emitted from the measured object is converted into an electrical signal by the detector(HgCdTe) and display as a color or black & white thermal image by way of optical scanning, The experiment was conducted for Venlo-type greenhouse with pad & fan system. The temperature difference between measured by Thermo-trace and measured by HOBO sensor is maximum 0.8$^{\circ}C$. Thermo-trace is possible to use for the thermal environment analysis and diagnosis of a cooling and heating system of greenhouse.

  • PDF

On the Study of Intraseasonal and Interannual Oscillations Simulation by using Coupled Model (접합모형을 이용한 경년 및 계절안 진동 모사실험 연구)

  • Ahn Joong-Bae
    • Journal of Environmental Science International
    • /
    • v.8 no.6
    • /
    • pp.645-652
    • /
    • 1999
  • In order to simulate and investigate the major characteristics of El Nino/Southern Oscillation(ENSO) and Madden Jullian Oscillation(MJO), an intermediate type atmosphere-ocean coupled model is developed and their results are examined. The atmosphere model is a time-dependent non-linear perturbation moist model which can determine the internal heating for itself. The counterpart of the atmosphere model is GCM-type tropical ocean model which has fine horizontal and vertical grid resolutions. In the coupled experiment, warm SST anomaly and increased precipitation and eastward wind and current anomalies associated with ENSO and MJO are properly simulated in Pacific and Indian Oceans. In spite of some discrepancies in simulation MJO, the observed atmospheric and oceanic low-frequency characteristics in the tropics are successfully identified. Among them, positive SST anomalies centered at the 100m-depth of tropical eastern-central Pacific due to the eastward advection of warm water and reduced equatorial upwelling, and negative anomalies in the Indian and western Pacific seem to be the fundamental features of tropical low-frequency oscillations.

  • PDF