• Title/Summary/Keyword: Non-Heat Treatment

Search Result 518, Processing Time 0.029 seconds

Casting of Ductile Cast Iron using Metal Mold and Improvement of Impact Toughness by Direct Tempering (금형주조법에 의한 구상흑연주철의 제조 및 직접 템퍼링에 의한 충격인성 향상)

  • Choi, Sung Bae;Lee, Won Sik;Hong, Young Hwan
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.10 no.3
    • /
    • pp.159-164
    • /
    • 1997
  • Non-alloyed and 1.0%Ni alloyed ductile cast iron were cast into the sand mold and metal mold, and finer graphite size was obtained in case of metal mold casting. Direct tempering after casting showed the slight increase of absorbed energy, which is largely due to the relieving of residual stress that is developed during casting. After austempering heat treatment, higher impact energy was obtained in case of metal mold casting than sand mold casting, which is due to the finer graphite size.

  • PDF

Performance Analysis and Testing of a Cross-Flow Aluminum Heat Exchanger for Kitchen Ventilation (주방환기용 직교류 알루미늄 열교환기의 성능해석 및 시험)

  • Kim N.H.;Cho J.P.;Han S.P.;Choi J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.193-201
    • /
    • 2006
  • Thermal performance model was developed for a cross-flow aluminum heat exchanger with relatively short passage. Appropriate heat transfer coefficient and friction factor equations for laminar channel flow were obtained considering developing regions. The heat exchanger was analyzed using the unmixed cross-flow ${\epsilon}$-NTU relationship considering leak-age between streams. Thermal contact between corrugations and plates was also considered. Tests were separately conducted for two samples - one made of non-treated aluminum sheets, and the other made of varnish-treated ones. The samples were made by stacking corrugations and plates one after another. The model adequately predicted the thermal performance and pressure drop of the non-treated heat exchanger. The thermal performance of the varnish-treated one was $7{\sim}12%$ overpredicted, and the pressure drop of the varnished-treated heat exchanger was $5{\sim}15%$ underpredicted. The air leakage ratio of the non-treated heat exchanger was $23{\sim}26%$. The ratio decreased to less than $10%$ with the varnish treatment.

Enhancement of Wear Resistance by Low Heat Treatment and the Plasma Source Ion Implantation of Tungsten Carbide Tool (초경 엔드밀의 플라즈마 이온 주입과 저온 열처리를 통한 내마멸성 향상)

  • Kang, Seong-Ki;Wang, Duck-Hyun;Kim, Won-Il
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.2
    • /
    • pp.162-168
    • /
    • 2011
  • In this research, nitrogen plasma source ion implantation(PSII) of non-coated tungsten carbide endmill tools was conducted with low heat treatment for increasing wear resistance. After the low heat treatment of PSIIed tools to give a homogeneity of wear resistance, the surface modification of tools was analyzed by hardness test, surface roughness and cutting forces. As for the resultant cutting forces, low heat treatment in temperature of $400^{\circ}C$ and $500^{\circ}C$ is stable because of low cutting resistance. The 20-minutes heat treated tool at spindle speed 25000rpm has superiority of surface roughness, Ra of $0.420{\mu}m$ and was found to have good wear resistance. The higher hardness value was obtained by increasing temperature from $300^{\circ}C$ to $600^{\circ}C$ for PSIIed tools with low heat treatment. As the PSIIed tools under 10minutes at temperature of $600^{\circ}C$ have the highest hardness as Hv of 2349.8, It was analyzed that temperature processing give much influences on hardness.

Changes in Microstructure and Mechanical Properties due to Heat Treatment of Mg-1.0Al-1.0Zn-0.2Mn-0.5Ca Alloy Sheet Manufactured via Normal Casting and Twin Roll Casting Process (일반주조 및 쌍롤주조 공정으로 제조된 Mg-1.0Al-1.0Zn-0.2Mn-0.5Ca 합금 판재의 열처리에 따른 미세조직 및 기계적 특성 변화)

  • Dong Hwan Eom;No Jin Park
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.36 no.6
    • /
    • pp.359-366
    • /
    • 2023
  • Changes in microstructure and mechanical properties of Mg-1.0Al-1.0Zn-0.2Mn-0.5Ca (AZMX1100) alloy sheet manufactured by normal casting and twin roll casting process, were studied according to process and heat treatment. Non-uniform microstructure was observed in the initial sheet produced through both processes, and in particular, tilted dendrites and shifted central segregation were observed in the twin roll casting sheet. It was homogenized through hot rolling and heat treatment, and heat treated at 350℃ and 400℃ to compare the effect of heat treatment temperature. Both sheets were homogenized by the hot rolling process, and the grain size increased as the heat treatment temperature and time increased. It was confirmed that the grain size, deviation, and distribution of the second phase were finer and more homogenized in the TRC sheet. Accordingly, mechanical properties such as hardness, formability, and tensile strength also showed better values. However, unlike other previously reported AZMX alloy systems, it showed low formability (Erichsen value), which was judged by the influence of Al2Ca present in the microstructure.

A Study on the Machining Characteristics of Prototype of Roller Gear Cams (롤러 기어 캠의 시제품 가공특성에 관한 연구)

  • Kim, Jin-Su;Kang, Seong-Ki;Lee, Dong-Seop
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.5
    • /
    • pp.60-67
    • /
    • 2012
  • In the study, the effect grinding condition on the workpiece arithmetical average roughness(Ra) to 10 steps leading to cutting each section with the spindle rotational speed 8000rpm and feed rate 150mm/min of grinding in GC(green silicon carbide) grinding processing after heat treatment and non heat treatment of SCM415 material. Also the following conclusions were obtained analysis of stress distribution displacement and finite elements method(FEM) on assemble parts with 3+2 axis simultaneous control through grinding and gave a load 11kg on ATC arm both sides gave a load of 11kg. For the centerline average roughness(Ra) in the heat and non-heat treatment work pieces, which were appeared the most favorable in the fifth section were $0.511{\mu}m$ and $0.514{\mu}m$, that were shown in the near the straight line section was the smallest deformation of curve. In addition, the bad surface roughness appeared on the path is too long by changing angle, the more inclined depth of cut, because the chip discharging is not smoothly.

Evaluation of Non-Thermal Decontamination Processes to Have the Equivalence of Thermal Process in Raw Ground Chicken

  • Park, Eunyoung;Park, Sangeun;Hwang, Jeong Hyeon;Jung, Ah Hyun;Park, Sung Hee;Yoon, Yohan
    • Food Science of Animal Resources
    • /
    • v.42 no.1
    • /
    • pp.142-152
    • /
    • 2022
  • The present study was aimed at examining the antibacterial effects of nonthermal decontamination processes, which are equivalent to thermal treatment, to ensure microbiological safety of raw ground chicken. Escherichia coli or Salmonella were inoculated into 25 g of raw ground chicken samples. The raw ground chicken samples were non-treated or treated with high hydrostatic pressure (HHP) at 500 MPa (1-7 min), light-emitting diode (LED) irradiation at 405 nm wavelength (30-120 min), and heat at 70℃, 90℃ (1-60 min), and 121℃ (1-15 min). E. coli and Salmonella cell counts were enumerated after treatments. Moreover, the color parameters of treated raw ground chicken were analyzed. HHP treatment reduced E. coli and Salmonella cell counts by more than 5 Log CFU/g and more than 6 Log CFU/g after 7 min and 1 min, respectively; these effects were equivalent to those of thermal treatment. However, LED irradiation reduced Salmonella cell counts by only 0.9 Log CFU/g after 90 min of treatment, and it did not reduce E. coli cell counts for 90 min. Compared with those of the non-treated samples, the ΔE (total color difference) values of the samples treated with HHP were high, whereas the ΔE values of the samples treated with LED irradiation were low (1.93-2.98). These results indicate that despite color change by HHP treatment, HHP treatment at 500 MPa could be used as a non-thermal decontamination process equivalent to thermal treatment.

Clinical Characteristics and Prognosis of Heat Stroke (열사병의 임상적 특징 및 예후에 관한 연구)

  • Park, Noh Han;Ryoo, Hyun Wook;Seo, Kang Suk;Park, Jung Bae;Chung, Jae Mung
    • Journal of Trauma and Injury
    • /
    • v.19 no.2
    • /
    • pp.113-120
    • /
    • 2006
  • Purpose: The aim of this study was to evaluate the clinical characteristics of classic heat stroke in Korea and to identify factors of prognosis for heat stroke by comparing a survival group with a non-survival group. Methods: We retrospectively analyzed 27 patients with heat stroke who visited the Emergency Department of Kyungpook National University Hospital from March 2001 to February 2005. First, we divided the patients into two groups, the classic heat stroke group and the exertional heat stroke group, and compared them. Second, we compared the survival group with the non-survival group. Age, sex, cause, place where patients were found, underlying diseases, cooling time, performance of endotracheal intubation, initial Glasgow Coma Scale, initial vital sign, and laboratory findings were reviewed. Results: Five of 27 patients in heat stroke died. The classic heat stroke group had 20 patients. They were old and had more patients in the bathroom than the exertional heat stroke group had. The non-survival group showed lower blood pressure, lower initial GCS score, and higher respiratory rate than the survival group. In laboratory findings, the non-survival group also showed lower$HCO_3-$ level, lower albumin level, lower glucose level, more prolonged PT, and higher CK-MB level than the survival group. Delay in recognition of heat stroke and cooling were poor prognostic factors in heat stroke. Conclusion: The classic heat stroke group had patients who were old and found in the bathroom. Early recognition and treatment of heat stroke is important to reduce mortality. Cooling time, initial GCS score, mean arterial pressure, resipratory rate, $HCO_3-$, PT, CK-MB, and albumin seem to be meaningful when forming a prognosis for heat stroke patients.

A Study on Nitridation and Oxidation Reaction of Titanium Powder (금속티타늄분말의 질화반응과 산화반응에 관한 연구)

  • Lee, Young-Ki;Sohn, Yong-Un;Cho, Young-Soo;Kim, Yong Seog;Kim, Suk-Yoon
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.8 no.2
    • /
    • pp.137-148
    • /
    • 1995
  • The nitridation kinetics of titanium powder were studied by isothermal and non-isothermal (dynamic) methods in high purity nitrogen under I atm pressure. For the comparison with nitridation, the oxidation kinetics of titanium powder were also studied in dry oxygen at I atm pressure. An automatic recording electrobalance was used to measure the weight gain as a function of time and temperature. For the reaction with nitrogen, the nitride was formed at over $700^{\circ}C$. The reaction with nitrogen followed the parabolic rate law, and the activation energy was calculated to be 31 kcal/mol in the isothermal method (above $900^{\circ}C$). The non-stoichiometric TiNx has been synthesized by the nitridation at a proper temperature and time, followed by the homogenizing treatment above $1100^{\circ}C$. In comparison with the stoichiometric $TiN_{1.0}$ and the non-stoichiometric TiNx ($TiN_{0.5}$ and $TiN_{0.65}$), the hot oxidation characteristics of the former is superior to that of the latter. However, both non-stoichiometric nitrides make little difference in the hot oxidation characteristics.

  • PDF

Effects of Combustion Characteristics of the Burners for Non-Oxidizing Direct Fired Furnaces on the Oxidization of the Surface of Steel Plate (무산화 직화로 버너의 연소특성이 강재표면의 산화에 미치는 영향)

  • Park, Heung Soo;Riu, Kap Jong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.3
    • /
    • pp.330-341
    • /
    • 1999
  • An experimental study for the two types of burners used in the non-oxidizing direct fired furnaces of the heat treatment process for the cold rolled plate has been carried out to investigate the combustion characteristics and the oxidization of the surface of steel plate. A steep temperature gradient and entrainment of residual oxygen were found near the heating surface in the flame of the nozzle mixing burner which has strong swirl velocity component. It was concluded that the elimination of the residual oxygen and the increase of the temperature of combustion gas on the heating surface are needed to enhance the performance of the burners for application to the non-oxidizing direct fired furnaces.

Effect of heat treatment in $HfO_2$ as charge trap with engineered tunnel barrier for nonvolatile memory (비휘발성 메모리 적용을 위한 $SiO_2/Si_3N_4/SiO_2$ 다층 유전막과 $HfO_2$ 전하저장층 구조에서의 열처리 효과)

  • Park, Goon-Ho;Kim, Kwan-Su;Jung, Myung-Ho;Jung, Jong-Wan;Chung, Hong-Bay;Cho, Won-Ju
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.24-25
    • /
    • 2008
  • The effect of heat treatment in $HfO_2$ as charge trap with $SiO_2/Si_3N_4/SiO_2$ as tunnel oxide layer in capacitors has been investigated. Rapid thermal annealing (RTA) were carried out at the temperature range of 600 - $900^{\circ}C$. It is found that all devices carried out heat treatment have large threshold voltage shift Especially, device performed heat treatment at $900^{\circ}C$ has been confirmed the largest memory window. Also, Threshold voltage shift of device used conventional $SiO_2$ as tunnel oxide layer was smaller than that with $SiO_2/Si_3N_4/SiO_2$.

  • PDF