• Title/Summary/Keyword: Noise-Level Measurement

Search Result 553, Processing Time 0.024 seconds

Sound Source Level Error on Element Spacing and Depth of Hydrophone Array (수중청음기 배열의 간격 및 깊이 변화에 따른 측정 소음준위 오차)

  • 윤종락
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1997.06a
    • /
    • pp.68-74
    • /
    • 1997
  • Ship radiated noise is an infortant parameter which dtermines Anti Submarine Warfare(ASW) countermeansure or passive Sonar detection and classification performance. Its measurement should be performed under controlled ocean acoustic environment. In data reduction of the measured data from hydrophone array, theeffect fo ambient noise, surface reflection and bottom reflection etc. should be compensated to obtain the source level of the ship radiated noise. This study describes the measurement hydrophone array design criteria based on the analysis of transimission anomaly due to the surface reflection.

  • PDF

A Study on the Characteristic of Driving Sound Noise for Various Optical Disk Drives (광디스크 드라이브의 종류별 구동소음 특성에 관한 연구)

  • Oh, Se-Won;Kim, Yu-Sung;Kim, Dong-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.580-586
    • /
    • 2005
  • In this study, experimental tests for driving noise of various optical disk drives (ODD) have been performed using 1/2' microphone noise measurement system. Several new and old ODD models by different manufacturers are practically considered and compared far realistic driving conditions. Sound insulation case with absorbing material fur the present experimental tests is designed and constructed using CATIA system. It is found that average data transfer rate, operating RPM, and sound noise level seems to be different for the same opposed speed ODD by different manufacturers. Moreover, driving sound noise level can be largely affected by both tray shape and driving speed even for the same apparent data transfer rate.

  • PDF

A Study on the Characteristic of Driving Sound Noise for Various Optical Disk Drives (광디스크 드라이브의 종류별 구동소음 특성에 관한 연구)

  • Oh, Se-Won;Kim, Yu-Sung;Kim, Dong-Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.10 s.103
    • /
    • pp.1169-1176
    • /
    • 2005
  • In this study, experimental tests for driving noise of various optical disk drives (ODD) have been performed using 1/2' microphone noise measurement system. Several new and old ODD models by different manufacturers are practically considered and compared for realistic driving conditions. Sound insulation case with absorbing material for the present experimental tests is designed and constructed using CATIA system. It is found that average data transfer rate, operating RPM, and sound noise level seem to be different for the ODD models with same denoted speed by different manufacturers. Moreover, driving sound noise level can be largely affected by both tray shape and driving speed even for the condition of the same apparent data transfer rate.

Methods of A-weighted Sound Pressure Level Measurement for Fans and Blowers (KS B 6361, Focus on Revised Content made in 2000) (송풍기의 소음레벨 측정방법 (KS B6361, 2000년 개정내용을 중심으로))

  • Kim, Kyoung-Ho;Lee, Seung-Bae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.424-432
    • /
    • 2000
  • The revision was provided for the method of A-weighted sound pressure measurement for fans and blowers, in which the newly developed measurement techniques were applied to KS B 6361. This revision includes the sound power methods for radiated sound from the body, the in-duct measurement method, and the correction method for flow noise upon measuring microphone, etc.

  • PDF

A Method on the Improvement of the Minimum Detection Distance of the Remote Measurement Level Meter (원격 측정 레벨계의 최소 탐지거리 성능 개선 방법)

  • Park, Dongkun;Lee, Kijun
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.3
    • /
    • pp.535-543
    • /
    • 2018
  • Recently, level meters have been associated with the safety and maintenance of industrial sites and require a wide measurement range. Generally, to ensure the measurement range of the level meter, the measurement environment is improved to reduce the noise or to compensate the distortion of the signal through signal processing. The noise of FMCW (Frequency Modulated Continuous Wave) radar level meter or the distortion of the signal affects the near region characteristics of the level gauge, resulting in a reduction of the minimum detection distance. In this paper, an equalizer filter considering characteristics of window function and bit spectrum is applied to remove the noise in the near region of the level meter to improve the minimum detection distance performance and to improve the measurement reliability in the vicinity of the level meter, which is relatively difficult to detect, we want to improve the detection range.

Effects of the Facade of the Buildings on the Sound Characteristics in an Apartment Complex (공동주택 입면 변화에 따른 단지 내 소음특성)

  • Kim, Yong-Hee;Lee, Pyoung-Jik;Jeon, Jin-Yong;Lee, Byung-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.367-370
    • /
    • 2005
  • This paper investigated the sound characteristics in an apartment complex. The field measurement was conducted in order to examine the acoustical characteristics of the apartment complex in situ. As a result, it shows that there are around 3 sec. reverberation time and the additional sound reinforcements at the area of high height due to the surrounded buildings. Thus, 1:50 Scale model measurement and Raynoise computer simulation were carried out with insertion of the parapet and the canopy on the balcony. In case of a single building, the parapet was effective to reduce noise level at low floor levels, and the canopy was effective to reduce noise level at high floor levels. But it also shows that both the parapet and the canopy were not effective to reduce noise level at middle floor levels. In case of an apartment complex, the canopy was less effective to reduce noise level at each floor in comparison with case of the single building.

  • PDF

Sound Power Level of Electric Home Appliances according to Measurement Method (측정방법별 가전제품의 음향파워레벨)

  • Kang, Dae-Joon;Gu, Jin-Hoi;Lee, Jae-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.4
    • /
    • pp.335-346
    • /
    • 2009
  • As the economy has grown and the main industry in Korea has been changed from secondary industry to tertiary industry, the importance of indoor environment has been a matter of common concern, in which one of the main concerns is to improve the indoor acoustic conditions. However, even though this is required more than before, there are no measures to protect the human being from the noise of electric home appliances. This is owing to the absence of the data about sound power level of electric home appliances. So, we investigate the sound power level of them and analyze the acoustical characteristics of each one. First, we tried to investigate the sound power measurement method of each electric home appliance. After it we test the sound power level of them. From the survey, we can know that the vacuum cleaner is the most noisy electric home appliance, and the refrigerator is the least noisy one. This results will help us predict the indoor noise level using the basic data of sound power level.

Study on Adequate Positioning of Environmental Noise Automatic Measuring System in Busan (부산시 환경소음 자동측정망 설치위치의 적정성에 관한 연구)

  • Kim, Hwa-Il;Han, Kyoung-Min
    • Journal of Environmental Policy
    • /
    • v.8 no.1
    • /
    • pp.31-48
    • /
    • 2009
  • To install and operate the Automatic Noise Monitoring Networks reasonably, which able to monitoring environmental noise continually, is an important issue for making decision to urban environment. Noise level is determined by regional environmental factors, that affected by complex urban environment. Therefore, accurate measurement of environmental noise level has top priority to establish and promote appropriate environmental policies. Currently, Automatic Noise Monitoring System is installed for grasping the environmental noise level and preparing basic data for constructing noise-reduction policies. However, this measurement data is recognized not to be able to reflect a sensory noise. The main reason is the lack of reliable measurement data and unreasonable installation site. The main point of this research ought to be the analysis of installed site of noise monitoring system in Busan.

  • PDF

A Study of Traffic Noise Characteristics on the National Highways (일반국도의 교통소음특성에 관한 연구)

  • Son, Hyeon Jang;An, Deok-Soon;Baek, Cheolmin;Kwon, Soo-Ahn;Lee, Jaejun
    • International Journal of Highway Engineering
    • /
    • v.15 no.2
    • /
    • pp.11-18
    • /
    • 2013
  • PURPOSES : This study presents the noise level and frequency characteristics investigated in the national highways with the consideration of various measuring conditions and/or methods. METHODS : The noise levels on the asphalt concrete pavement(ACP) and the jointed plain concrete pavement(JPCP) of the national highway were measured and analysed with respect to three variables, i.e., pavement type, surface condition, and measurement distance. The PASS-By method is utilized for the noise measurement and then using CPB spectrum analysis method with 1/3 octave bandwidth, the noise levels and frequency characteristics were calculated for two-second periods before and after the peak noise. RESULTS : Depending on the pavement type, the noise level was changed as the average noise levels are 73.3dB(A) and 78.3dB(A) for ACP and JPCP, respectively. With respect to the effect of surface condition, the average noise levels for crack H(high), M(medium), and L (low) sections are 77.4dB(A), 77.4dB(A), and 78.1dB(A), respectively. Regarding the measurement distance, 1.2meter difference in measuring location reduces 1.6dB(A) of noise level; the average noise levels at 5.3m and 7.5m from the centerline of outer lane are 72.8dB(A) and 71.2dB(A), respectively. It should be noted that the noise levels are slightly different as a function of vehicle speed and type. However, the overall trends for each case was similar. It was found that the domain frequency bands for ACP and JPCP were 400Hz~2000Hz and 500Hz~2000Hz, respectively. CONCLUSIONS : Based on the analysis with the measured noise date from national highway, it was concluded that the noise level and frequency band vary depending on the various conditions. It was also found that some variables significantly affect the noise level while others do not. With further systematic investigation, the comprehensive noise characteristics on the national highway can be achieved. Using such database, it is possible to develop the fundamental noise reduction technology.

The measurement and analysis of Regenerative Pump Noise (재생펌프 소음특성의 측정 및 해석에 관한 연구)

  • Kim, Tae-Hoon;Seo, Young-Soo;Jeong, Weui-Bong;Jeong, Ho-Kyeong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1067-1071
    • /
    • 2004
  • In this paper, the characteristic of the regenerative pump is reviewed by the measurement and the analysis. The dominant noise sources are harmonic components of the rotating impeller frequency. The acoustic characteristics and the noise source position at the dump are identified. In order to reduce the high-level peak noise, the interior flow of the pump chamber is analyzed by CFD (Computational Fluid Dynamics). Acoustic pressure is calculated with Ffowscs Williams and Hawkings equation. As the result of the analysis new design of the pump chamber is recommended. The recommended pump is compared with original pump by evaluating the RMS value of a interior static pressure and the sound pressure level. The new pump chamber recommended by analysis results is proved by a process of the measurement. The overall SPL of a recommended pump is reduced about 3 dBA.

  • PDF