• Title/Summary/Keyword: Noise-Induced

Search Result 1,113, Processing Time 0.033 seconds

Analysis of relative contribution of machinery-induced vibration/flow-induced vibration to noise radiation from compressor discharging piping system in air-conditioner outdoor unit (에어컨 실외기 압축기 배기 배관계의 기기 기인 진동/유동 기인 진동의 방사소음에 대한 상대적 기여도 분석)

  • Sangheon Lee;Cheolung Cheong;Jinhyung Park;Jangwoo Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.1
    • /
    • pp.122-130
    • /
    • 2024
  • Vibration of compressor in the air-conditioner outdoor unit have known to be main noise source radiated from outdoor unit. However, as the operating speed of compressor increase, the relative contribution of flow induced vibration and noise is also increase. In this paper, the numerical method was established to predict fluid-borne noise from compressor discharging pipe of air-conditioner outdoor unit. In this step, numerical result was compared to experimental one to verify numerical method. Additionally, the effects of pressure pulsation of compressor and compressor vibration into radiated noise were investigated in frequency domain. It was confirmed that the compressor vibration contributed to the low frequency band, while the pressure pulsation dose to the high frequency band.

Ergonomic Evaluation and Safety Countermeasures of Personal Cassette Player Noise (휴대용 카세트 소음의 인간공학적 평가 및 안전대책)

  • Park, Min-Yong;Hong, Seong-Wan
    • Journal of the Ergonomics Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.47-55
    • /
    • 1999
  • Recently, noise from personal cassette players (PCP) poses growing concerns together with occupational noise-induced hearing loss. Eighteen male and female volunteer subjects participated to determine preferred noise levels for PCP usage before, during, and after 2-hour subway riding according to sources (types) of PCP listening (language/news, soft music, and hard music). Audiometric tests were conducted before and after the 2-hour exposure of PCP noise under subway riding. Statistical analyses showed some significant hearing losses with the greatest loss of more than 6 dB at 4000 Hz for both ears, indicating that serious noise-induced hearing loss would potentially occurred due to prolonged use of PCPs. Practical safety countermeasures against PCP noise are further discussed.

  • PDF

A Prediction of Airflow-Induced Noise in DVD Drive using Acoustic Analogy (음향상사이론을 이용한 DVD Drive 내에서의 유동소음 예측)

  • Yoo, Seung-Won;Lee, Jong-Soo;Min, Oak-Key
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.502-507
    • /
    • 2000
  • This paper presents the numerical prediction of airflow-induced sound in DVD drives. Computational fluid dynamics (CFD) is first conducted to evaluate flow field characteristics due to the high-speed disk rotation, and to support the acoustic analysis. The acoustic analogy based on Ffowcs Williams-Hawkings (FW-H) equation is adopted to predict aeroacoustic noise patterns. The integral solution for quadrupole volume source is included to identify the turbulence noise generated inside the DVD tray. Near-field noise is strongly affected by the flow field characteristic, which is caused by the complex shape of the tray. For a mid-field, the quadrupole noise play as a counterpart of thickness noise or loading noise, resulting in a different pattern compared with those in the near field.

  • PDF

Modified Hadamard Codes for Spectral-Amplitude-Coding Optical CDMA (Spectral-Amplitude-Coding Optical CDMA를 위한 Modified Hadamard Code)

  • Jhee, Yoon-Kyoo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.8
    • /
    • pp.5-9
    • /
    • 2011
  • Spectral-amplitude-coding optical CDMA systems using codes based upon Hadamard matrices have very restrictive code lengths of $2^n$ and high phase-induced intensity noise(PIIN). In this paper a new code family, namely modified Hadamard code, is proposed to relax the code length restriction and the number of simultaneous users. The improved performance of the proposed system is analysed with the consideration of noise.

Experimental Analysis of the Effect of Phase Change at the Entrance of a Capillary Tube by Sub-cooling Control on Refrigerant-induced Noise (과냉도에 따른 모세관 입구단에서의 냉매 상태 변화가 냉장고 냉매 소음에 미치는 영향의 실험적 분석)

  • Oh, Young-Hoo;Kim, Min-Seong;Han, Hyung-Suk;Kim, Tae-Hoon;Jeong, Weui-Bong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.12
    • /
    • pp.1184-1190
    • /
    • 2012
  • This study is focused on the experimental analysis of the noise induced by phase change of refrigerant at the entrance of capillary tube. The refrigerant is usually two-phase condition when it flowed into the capillary tube. At the entrance of capillary tube, the phase condition of refrigerant is formed by sub-cool control. If it has sufficient sub-cool temperature, all of the vapor refrigerants turned to liquid, which means there is only liquid. Otherwise, the gas is coexisted. Based on this theory, we experiment on each case by changing sub-cool temperature using refrigerant-supplying equipment. The noise level is measured for each case and compared.

Compressor BPF noise reduction for an automotive turbocharger (차량용 터보차져의 컴프레서 BPF 소음 저감)

  • Park, Ho-Il;Eom, Sang-Bong;Seo, Ju-Bong;Lee, Seung-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.851-856
    • /
    • 2012
  • Automotive turbochargers have become common in gasoline engines as well as diesel engines. They are excellent devices to effectively increase fuel efficiency and power of the engines, but they unfortunately cause several noise problems. The noises are classified into mechanical noises induced from movement of a rotating shaft and aerodynamic noises by air flow in turbochargers. The mechanical noises are whine and howling noises, and the aerodynamic noises are BPF (blade-passing frequency), pulsation, surge, some special frequency noises. These noises are bothering passengers because their levels are higher or their frequencies are clearly separated from engine or vehicle noises. The noise investigated in this paper is a BPF noise induced by compressor wheels, whose frequency is the multiplication of the number of compressor wheel blades and its rotational speed. The noise is strongly dependent upon the geometry of wheels and the number of blades. This study tried to apply a groove close to the inlet side of compressor wheels in order to reduce the BPF noise. The groove has successfully reduced the noise of narrow band frequency of a turbocharger. It shows that the groove could reduce the wide band frequency noise, the compressor BPF noise with a best shape of the groove.

  • PDF

A Numerical Study on the Characteristic of Airflow and Aeroacoustic Noise in DVD Drive (DVD 드라이브 내에서의 유동 및 유동소음 특성에 관한 수치적 연구)

  • Yoo, Seung-Won;Lee, Jong-Soo;Min, Oak-Key;Kim, Soo-Kyung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.759-764
    • /
    • 2000
  • The accurate prediction of aeroacoustic analysis is necessary for designers to control and reduce airflow-induced sound pressure levels in high speed rotating DVD drives. This paper focuses on the numerical prediction of airflow-induced sound in DVD drives. Computational fluid dynamics(CFD) is first conducted to evaluate flow field characteristics due to the high-speed disk rotation, and to support the acoustic analysis. The acoustic analogy based on Ffowcs Williams-Hawkings(FW-H) equation is adopted to predict aeroacoustic noise patterns. The integral solution for quadrupole volume source is included to identify the turbulence noise generated inside the DVD tray. The strength of sound pressure level with respect to rotating speed is discussed to meet upfront demand on the high fidelity product development. The present study also focuses on the noise directivity and examines how much the sound noise is sensitive to change in rotating speed. Near-field noise is strongly affected by the flow field characteristic, which is caused by the complex shape of the tray. For a mid-field, the quadrupole noise play as a counterpart of thickness noise or loading noise, so it generates different sound noise patterns compared with those in the near field.

  • PDF

Study for the prediction of ground-borne vibration induced by subway (지하철에 의한 지반 진동 예측에 관한 연구)

  • 이재원;김득성;장서일
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1287-1292
    • /
    • 2001
  • Subway train-induced ground-borne vibration is studied. Previously used vibration level prediction equations are reviewed. Measured vibration levels are compared with the predicted results and numerically computed results. The results show that vibration level does not decrease proportionally with the distance.

  • PDF

Acoustic emission source location and noise cancellation for crack detection in rail head

  • Kuanga, K.S.C.;Li, D.;Koh, C.G.
    • Smart Structures and Systems
    • /
    • v.18 no.5
    • /
    • pp.1063-1085
    • /
    • 2016
  • Taking advantage of the high sensitivity and long-distance detection capability of acoustic emission (AE) technique, this paper focuses on the crack detection in rail head, which is one of the most vulnerable parts of rail track. The AE source location and noise cancellation were studied on the basis of practical rail profile, material and operational noise. In order to simulate the actual AE events of rail head cracks, field tests were carried out to acquire the AE waves induced by pencil lead break (PLB) and operational noise of the railway system. Wavelet transform (WT) was first utilized to investigate the time-frequency characteristics and dispersion phenomena of AE waves. Here, the optimal mother wavelet was selected by minimizing the Shannon entropy of wavelet coefficients. Regarding the obvious dispersion of AE waves propagating along the rail head and the high operational noise, the wavelet transform-based modal analysis location (WTMAL) method was then proposed to locate the AE sources (i.e. simulated cracks) respectively for the PLB-induced AE signals with and without operational noise. For those AE signals inundated with operational noise, the Hilbert transform (HT)-based noise cancellation method was employed to improve the signal-to-noise ratio (SNR). Finally, the experimental results demonstrated that the proposed crack detection strategy could locate PLB-simulated AE sources effectively in the rail head even at high operational noise level, highlighting its potential for field application.

The Survey for the Maximum Noise Level of Portable Audio Equipments and Its Assessment (휴대용 음향기기 소음실태 및 소음도 평가)

  • Lee, Jaewon;Gu, J.H.;Park, H.G.;Lee, W.S.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.1
    • /
    • pp.3-8
    • /
    • 2013
  • Recently, the impact on hearing induced by using of portable audio equipment have been actively studied. In general, Because they turn the volume up with loud background noise, they may expose to louder noise. In this study, we investigated the maximum noise level of 20 the domestic potable audio equipment and estimated the impact of the hearing induced by portable audio equipment in according to exposure time. As a result, the use of portable audio equipment is assumed to be more three hours when the level of more than 50 % of volume is most likely to affect the hearing.