• Title/Summary/Keyword: Noise-Induced

Search Result 1,119, Processing Time 0.03 seconds

Ranging Performance Evaluation of Relative Frequency Offset Compensation in High Rate UWB (고속 UWB의 상대주파수 차이 보상에 의한 거리추정 성능평가)

  • Nam, Yoon-Suk;Lim, Jae-Geol;Jang, Ik-Hyeon
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.7
    • /
    • pp.76-85
    • /
    • 2009
  • UWB signal with high resolution capability can be used to estimate ranging and positioning in wireless personal area network. The node works on its local clock and the frequency differences of nodes have serious affects on ranging algorithms estimating locations of mobile nodes. The low rate UWB, IEEE802.15.4a, describes asynchronous two way ranging methods such as TWR and SDS-TWR working without any additional network synchronization, but the algorithms can not eliminate the effect of clock frequency differences. Therefore, the mechanisms to characterize the crystal difference is essential in typical UWB PHY implementations. In high rate UWB, characterizing of crystal offset with tracking loop is not required. But, detection of the clock frequency offset between the local clock and remote clock can be performed if there is little noise induced jitter. In this paper, we complete related ranging equations of high rate UWB based on TWR with relative frequency offset, and analyze a residual error in the ideal equations. We also evaluate the performance of the relative frequency offset algorithm by simulation and analyze the ranging errors according to the number of TWR to compensate coarse clock resolution. The results show that the relative frequency offset compensation and many times of TWR enhance the performance to converge to a limited ranging errors even with coarse clock resolutions.

The Effect of Orally Administered Herbal Medicines in Collagen, LPS, CFA Induced Rheumatoid Like Arthritis Animal Model: A Systematic Review of Animal Study Articles Published in Korea after 2008 (Collagen, LPS, CFA로 유발된 류마티스 유사 관절염 동물실험 모델에서 한약제제 경구투여의 효과: 2008년 이후 발표된 국내 논문에 대한 체계적 문헌고찰)

  • Won, Jeong-Yoon;Jeon, Chae-Heun;Song, Ho-Joon;Jeong, Ji-Won;Kim, Tae-Gwang;Kim, Hyun-Ho;Leem, Jungtae
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.27 no.4
    • /
    • pp.33-53
    • /
    • 2017
  • Objectives This study was designed to review animal studies about the efficacy of herbal medicine for Rheumatoid arthritis animal model which was published in Korea after 2008. We also systematically investigated the reporting quality of the animal studies. Methods We systematically searched original articles in 8 databases since 2008. And manual searching was conducted through 10 Korean medicine journals from 2008. Studies were included if they used animal experimental model(s) with orally administered herbal medicine. Data were extracted regarding animal model, rheumatoid arthritis indicator and detail of intervention. Reporting quality of each study was also assessed by the STARA and ARRIVE guidelines. Results Nine hundred two articles were screened. Finally, 35 articles were included. 35 studies all showed that the herbal medicine used in the studies has significant effect on alleviating the macroscopic indicators, hematological indicators, histological indicators, genetic indicators, osteological indicator of Rheumatoid Arthritis and others. Species of animals was reported in 100% while ventilation and noise were reported in 0% in STRASA guidelines. Ethical statement was reported in 42.9%, experimental animals and sample size were reported in 24%, 29% and there was no study reporting funding. Conclusions These results suggest that herbal medicine might be effective treatment for Rheumatoid Arthritis. It should be improved by clinical studies. And there is a need for studying about efficacy and safety of each specific herbal medicine. And we should improve the Reporting quality of the animal studies published in Korea.

The Correlation between The Size and Location of Vocal Polyp and Voice Quality, Before and After Laryngeal Microsurgery (후두미세수술 전후 성대 용종의 크기 및 위치가 음성의 질의 변화에 미치는 영향)

  • Han, Won Gue;Kim, Min-Su;Oh, Kyung Ho;Woo, Jeung Soo;Jung, Kwang Yoon;Kwon, Soon Young
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.27 no.2
    • /
    • pp.102-107
    • /
    • 2016
  • Background and Objectives : Vocal polyps are caused by inflammation induced by stress or irritation. Many patients with vocal polyps complain voice discomfort. For vocal polyps, surgery such as laryngeal microsurgery has been the mainstay of management. We analyzed the clinical features of vocal polyps, and how the size and location of vocal polyps affect the outcomes of surgery. Methods : We retrospectively reviewed 42 patients from March 2014 to December 2015, who were diagnosed as unilateral single vocal polyp. When we operated on a vocal polyp with laryngeal microscopy, we measured their size and location. The quality of voice was evaluated by GRABS scale, jitter, shimmer, NHR (noise to harmonic ratio), MPT (maximum phonation time), and VHI (voice handicap index) before operation and 4 weeks after operation. Results : When we divided the patients into large-sized vocal polyp group (the longest length >3 mm) and small-sized vocal polyp group (the longest length ${\leq}3mm$), all parameter differences tend to be greater at large sized vocal polyp. However, these differences were not statistically significant (p>0.05). When we divided into two groups depending on the volume of vocal polyp, no distinct tendency was found. When we compared the location (anterior, mid and posterior) of vocal polyp with the improvement of voice quality, more change was found at mid portion vocal polyp, except the difference of VHI. However, these differences were also not statistically significant (p>0.05). Conclusion : All parameter differences tend to be greater at large vocal polyp and polyp of the mid location.

  • PDF

A Study on the Characteristics of Smartphone Camera as a Medical Radiation Detector (의료 방사선 검출기로써 스마트폰 카메라의 특성에 관한 연구)

  • Kang, Han Gyu;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.5
    • /
    • pp.143-151
    • /
    • 2016
  • The aim of this study is to investigate the optimal algorithm to extract medical radiation induced pixel signal from complementary metal-oxide semiconductor (CMOS) sensors of smartphones camera. The pixel intensity and pixel number of smartphone camera were measured as the X-ray dose was increased. The front camera of the smartphone camera has low noise property and excellent dose response as compared to the back camera of the smartphone. The indirect method which uses scintillation crystal in front of the smartphone camera, couldn't improve the X-ray detection efficiency as compared to the direct method which does not use any scintillator in front of the smartphone camera. When we used the algorithm which employing threshold level on the pixel intensity and pixel number, the dose linearity was more higher for the pixel intensity rather for the pixel number. The use of pixel intensity of Y color component which represents the grey scale, would be efficient in terms of the radiation detection efficiency and reducing the complexity of the image processing. We expect that the radiation dose monitoring can be managed effectively and systematically by using the proposed radiation detection algorithm, thus eventually will contribute to the public healthcare.

Tracking Control using Disturbance Observer and ZPETC on LonWorks/IP Virtual Device Network (LonWorks/IP 가상 디바이스 네트워크에서 외란관측기와 ZPETC를 이용한 추종제어)

  • Song, Ki-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.1
    • /
    • pp.33-39
    • /
    • 2007
  • LonWorks over IP (LonWorks/IP) virtual device network (VDN) is an integrated form of LonWorks device network and IP data network. LonWorks/IP VDN can offer ubiquitous access to the information on the factory floor and make it possible for the predictive and preventive maintenance on the factory floor. Timely response is inevitable for predictive and preventive maintenance on the factory floor under the real-time distributed control. The network induced uncertain time delay deteriorates the performance and stability of the real-time distributed control system on LonWorks/IP virtual device network. Therefore, in order to guarantee the stability and to improve the performance of the networked distributed control system the time-varying uncertain time delay needs to be compensated for. In this paper, under the real-time distributed control on LonWorks/IP VDN with uncertain time delay, a control scheme based on disturbance observer and ZPETC(Zero Phase Error Tracking Controller) phase lag compensator is proposed and tested through computer simulation. The result of the proposed control is compared with that of internal model controller (IMC) based on Smith predictor and disturbance observer. It is shown that the proposed control scheme is disturbance and noise tolerant and can significantly improve the stability and the tracking performance of the periodic reference. Therefore, the proposed control scheme is well suited for the distributed servo control for predictive maintenance on LonWorks/IP-based virtual device network with time-varying delay.

Flood Inflow Estimation at Large Multipurpose Dam using Distributed Model with Measured Flow Boundary Condition at Direct Upstream Channels (직상류 계측유량경계조건과 분포형모델을 이용한 대규모 다목적댐 홍수유입량 산정)

  • Hong, Sug-Hyeon;Kang, Boosik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.1039-1049
    • /
    • 2015
  • The inflow estimation at large multipurpose dam reservoir is carried out by considering the water balance among the discharge, the storage change during unit time interval obtained from the observed water level near dam structure and area-volume curve. This method can be ideal for level pool reservoir but include potential errors when the inflow is influenced by the water level slope due to backwater effects from upstream flood inflows and strong wind induced by typhoon. In addition, the other uncertainties arisen from the storage reduction due to sedimentation after the dam construction and water level noise due to mechanical vibration transmitted from the electric power generator. These uncertainties impedes the accurate hydraulic inflow measurement requiring exquisite hydrometric data arrangement for reservoir waterbody. In this study, the distributed hydrologic model using UBC-3P boundary setting was applied and its feasibility was evaluated. Finally, the modeling performance has been verified since the calculated determination coefficient has been in between 0.96 to 0.99 after comparing with observed peak inflow and total inflow at Namgang dam reservoir.

Medetomidine Sedation and Its Antagonism by Yohimbine in Dogs (개에서 Medetomidine 진정에 대한 Yohimbine의 길항작용)

  • Heo, Keong-Hee;Lee, Jae-Yeon;Choi, Kyeong-Ha;Cho, Jin-Haeng;Park, Chang-Sik;Kim, Myung-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.27 no.4
    • /
    • pp.343-347
    • /
    • 2010
  • The purpose of this study was to determine the antagonistic effects of yohimbine on sedation induced in dogs with medetomidine. Six mixed breed dogs were repeatedly used at a 2 weeks withdrawal time in this study. The dogs received $40\;{\mu}g/kg$ of medetomidine followed 15 minutes later by 0.2 ml/kg saline solution (group M) or 0.11 mg/kg yohimbine (group MY). All the dogs were examined before and 5, 15, 30, 45, 60, 75, 90, 120 and 150 minutes after the injection of medetomidine, and the induction and recovery times, vital signs, blood biochemistry and anesthetic quality were recorded. There were significant differences in the recovery of anesthesia between the groups. In both groups the heart rate decreased rapidly down to five minutes after the administration of medetomidine. The activity of ALT, AST and the protein concentration did not change significantly in either group and there was no significant difference between them at any time. Response to noise, muscle tone and analgesic score in the MY group at 30 minutes were significantly lower than those of the M group. When recovering from anesthesia, the dogs treated with yohimbine took less time to achieve sternal recumbency and less time to be able to stand and walk. It was concluded that yohimbine reversed effectively medetomidine sedation in dogs.

Static and Dynamic Behavior at Low-Frequency Range of Floating Slab Track Discretely Supported by Rubber Mounts in Real-Scale Laboratory Test (고무 마운트로 이산 지지되는 플로팅 슬래브 궤도의 실모형 실내 실험에서의 정적 및 저주파 대역 동적 거동)

  • Hwang, Sung Ho;Jang, Seung Yup;Kim, Eun;Park, Jin Chul
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.5
    • /
    • pp.485-497
    • /
    • 2012
  • Recently, with increasing social interests on noise and vibration induced by railway traffic, the application of floating slab track that can efficiently reduce the railway vibration is increasing. In this study, to more accurately understand the dynamic behavior of the floating slab track, a laboratory mock-up test has been performed, and the static and dynamic behaviors at frequency range near the system resonance frequency were explored. Based on the test results, the design of the floating slab track and the structural analysis model used in the design have been verified. The analytic and test results demonstrate that the dominant frequency of the floating slab track occurs at the frequencies between vertical rigid body mode natural frequency and bending mode natural frequency, and the dominant deformation mode is close to the bending mode. This suggests that in the design of the floating slab track, the bending rigidity of the slab and the boundary conditions at slab joints and slab ends should be taken into consideration. Also, the analytic results by the two-dimensional finite element analysis model using Kelvin-Voigt model, such as static and dynamic deflections and force transmissibility, are found in good agreement with the test results, and thus the model used in this study has shown the reliability suitable to be utilized in the design of the floating slab track.

Gaussian Noise Reduction Algorithm using Self-similarity (자기 유사성을 이용한 가우시안 노이즈 제거 알고리즘)

  • Jeon, Yougn-Eun;Eom, Min-Young;Choe, Yoon-Sik
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.5
    • /
    • pp.1-10
    • /
    • 2007
  • Most of natural images have a special property, what is called self-similarity, which is the basis of fractal image coding. Even though an image has local stationarity in several homogeneous regions, it is generally non-stationarysignal, especially in edge region. This is the main reason that poor results are induced in linear techniques. In order to overcome the difficulty we propose a non-linear technique using self-similarity in the image. In our work, an image is classified into stationary and non-stationary region with respect to sample variance. In case of stationary region, do-noising is performed as simply averaging of its neighborhoods. However, if the region is non-stationary region, stationalization is conducted as make a set of center pixels by similarity matching with respect to bMSE(block Mean Square Error). And then do-nosing is performed by Gaussian weighted averaging of center pixels of similar blocks, because the set of center pixels of similar blocks can be regarded as nearly stationary. The true image value is estimated by weighted average of the elements of the set. The experimental results show that our method has better performance and smaller variance than other methods as estimator.

Development of Signal Processing Modules for Double-sided Silicon Strip Detector of Gamma Vertex Imaging for Proton Beam Dose Verification (양성자 빔 선량 분포 검증을 위한 감마 꼭지점 영상 장치의 양면 실리콘 스트립 검출기 신호처리 모듈 개발)

  • Lee, Han Rim;Park, Jong Hoon;Kim, Jae Hyeon;Jung, Won Gyun;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.2
    • /
    • pp.81-88
    • /
    • 2014
  • Recently, a new imaging method, gamma vertex imaging (GVI), was proposed for the verification of in-vivo proton dose distribution. In GVI, the vertices of prompt gammas generated by proton induced nuclear interaction were determined by tracking the Compton-recoiled electrons. The GVI system is composed of a beryllium electron converter for converting gamma to electron, two double-sided silicon strip detectors (DSSDs) for the electron tracking, and a scintillation detector for the energy determination of the electron. In the present study, the modules of a charge sensitive preamplifier (CSP) and a shaping amplifier for the analog signal processing of DSSD were developed and the performances were evaluated by comparing the energy resolutions with those of the commercial products. Based on the results, it was confirmed that the energy resolution of the developed CSP module was a little lower than that of the CR-113 (Cremat, Inc., MA), and the resolution of the shaping amplifier was similar to that of the CR-200 (Cremat, Inc., MA). The value of $V_{rms}$ representing the magnitude of noise of the developed system was estimated as 6.48 keV and it was confirmed that the trajectory of the electron can be measured by the developed system considering the minimum energy deposition ( > ~51 keV) of Compton-recoiled electron in 145-${\mu}m$-thick DSSD.