• 제목/요약/키워드: Noise type

검색결과 2,638건 처리시간 0.055초

Manufacturing Characteristics of Cement-Bonded Wood Composite Board as Sound Absorption Type-Noise Barrier

  • Suh, Jin-Suk;Kang, Eun-Chang;Park, Jong-Young
    • Journal of the Korean Wood Science and Technology
    • /
    • 제32권6호
    • /
    • pp.50-56
    • /
    • 2004
  • This study was conducted to investigate the performance of sound absorption type-noise barriers manufactured with a combination of wood particles used for particleboard, recycled waste newspaper, and cement. An average density of wood-combined cement board was in the range from 0.83 to 0.96 g/cm3, showing relatively low-density board. Regardless of types of cement bonded board or wooden board, the board with concave holes(凹)-formed surfaces showed greater sound absorption coefficient compared to those of flat surface boards. The board density was not related with those coefficients. Accordingly, it was concluded that concave or deep corrugated surface structure has played an important role in sound absorption for the application of sound absorption type-noise barrier.

잡음하에서의 적응관측자 및 적응식별기에 관한 연구 (A Study on the Adaptive Observer/Adaptive Identifier in the Presence of Noise)

  • 최종호;남석우
    • 대한전기학회논문지
    • /
    • 제39권1호
    • /
    • pp.83-91
    • /
    • 1990
  • An adaptive observer which is applicable to discrete linear time invariant systems of ARMA type in the presence of noise is proposed. It first estimates the system parameters of the MA type by applying only the system input to the observer. Then it estimates the output which corresponds to the output of the system without any noise. This is a special case of Suzuki's adaptive observer. This estimated output is applied to Suzuki's adaptive observer to estimate the system parameters of ARMA type and the states. The proposed method can make the estimate errors of the system parameters sufficiently small even in the presence of noise in the system. It can also make the estimate errors of the states of the system sufficiently small when there is no process noise. These properties of the proposed adaptive observer is certified by computer simulation.

  • PDF

스마트 폼을 이용한 덕트 내부의 능동 소음 제어 (Active Noise Control in a Duct Using Smart Foam)

  • 김표재;강연준;조영만
    • 소음진동
    • /
    • 제11권3호
    • /
    • pp.422-427
    • /
    • 2001
  • In this paper is presented passive-active noise control in a duct using a ring-type smart foam. The ring-type smart foam is comprised of a PVDF film embedded in elastic noise control foam of lining shape. The embeddedPVDF element acts as an actuator to reduce noise at lower frequencies and the foam absorbs noise at higher frequencies. By implementing an adaptive filtered-x LMS algorithm, experiments are performed to reduce both tonal and broadband noise in a duct with one end closed and the other end open.

  • PDF

RSBS(Radial type SBS)를 이용한 복층포장구조에 의해 도로교통소음을 저감하는 기술 (Traffic Noise Reducing Technology using RSBS(Radial type SBS) Modifiers Into Double Layer Pavement)

  • 김병채;박진수;황경태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.568-572
    • /
    • 2013
  • This is traffic noise reducing technology with higher porosity and durability by using small aggregate in upper layer and big aggregate in lower layer utilizing RSBS modifier. We can reduce average 9dB(A) of traffic noise compare to normal pavement by double layer structure with higher durability using small gap over bigger gap. Also, it increases a porosity more than 22% with more durability by RSBS modifier.

  • PDF

원형 덕트 내에서 스마트 폼을 이용한 능동 소음 제어 (Active Noise Control in a Circular Duct Using Smart Foam)

  • 한제헌;김표재;강연준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.641-645
    • /
    • 2001
  • In this paper, it is discussed that active noise control in a circular duct using smart foam. Firstly, it is demonstrated that the potential of the conventional smart foam, proposed by Fuller, for active noise control in a duct. Conventional smart foam is not applicable to active noise control in a duct having flow. Thus, this paper presents a ring-type smart foam as an alternative. The ring-type smart foam consists of polyurethane acoustic foam of lining shape and PVDF film embedded in the foam. The embedded PVDF element acts as an actuator to reduce noise at lower frequencies and the foam absorbs noise at higher frequencies. A filtered-x LMS controller is used to minimize the signal from the error microphone. Experiments are executed to reduce broadband and tonal noise.

  • PDF

냉장고 냉매 소음의 저감에 관한 연구 (A Study on Reduction of Refirigerant Noise in Household Refrigerator)

  • 최성원;황원걸;설승윤;임형은;김상수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.1062-1066
    • /
    • 2004
  • In this study, refrigerant noise at connection of capillary tube and evaporator is investigated. Mechanism of refrigerant noise generation is examined in side-by-side type home refrigerator with two evaporators. It is found that the refrigerant noise is generated during refrigeration room fan-off (R-fan of) for that type refrigerator. The reason is that mass flow rate gets down during R-fan of and flow pattern is changed at outlet of capillary tube. We suggest designs for reduction of refrigerant noise with horizontal double expansion device, muffler, and accumulator. To evaluate those improved designs, sound quality index is used.

  • PDF

소음지도를 활용한 방음시설별 도로교통소음 개선효과에 관한 연구 (A Study on The Improvement Effects of Road Traffic Noise by The Noise Barrier Facilities Using a Noise Map Simulation)

  • 정재훈;박진호;권우택;김형철
    • 환경영향평가
    • /
    • 제17권4호
    • /
    • pp.213-224
    • /
    • 2008
  • Since 1970's rapid urbanization and economic growth, the population was highly increased and residential type was changed from single detached house to high density and high-rise apartment. Recently more high-rise residential building generates more traffic volumes and it makes spatial concentration. The highly traffic volumed road and high residential building was constructed nearby, it occurs noise problem. The purpose of this study is comparing the performance of three type noise barrier between noise source and receiver using a noise map simulation. Three types were composed as road side planting trees, building side planting trees and noise barrier wall. Planting trees is less effective than noise barrier wall as a noise barrier. And they are all effective under 3 stories than over 5 stories, especially noise barrier function can't work over 5 stories.

한국형 고속철도의 소음 방사특성에 관한 연구 (A Study on Radiation Characteristics of Noise Sources for Korean Train Express)

  • 김재철;구동회;문경호;이재응
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.323-327
    • /
    • 2002
  • In order to control the railway noise, the radiation characteristic of the noise during the train passage should be analyzed. Generally, the major noise sources for Korean Train Express are the rolling noise and power unit noise up to 300km/h. In this paper, we describe on a train model that is considered to be a row of point sources to calculate the radiation characteristic. The calculation results are compared with short distance measurement. It is shown that the radiation characteristic of the rolling noise is dipole type. The noise generated by the power unit is radiated as the cosine type. The noise level at an observer is increased in the direction of motion and reduced in the direction opposite to the motion with increasing of the train speed. The calculation results including the moving effect of the noise source at 300km/h show in good agreement.

  • PDF

육상용 디젤엔진 발전플랜트의 환경소음 영향 평가 및 저감 대책 (Environmental Noise Prediction and Countermeasures for Packaged Power Station)

  • 송근복;김원현;김동해;배종국
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.6-11
    • /
    • 2007
  • Packaged power station (PPS) is a stationary diesel engine generator set and developed for the supply of electric power to small villages, islands and factories etc. Therefore, the PPS is closely installed to residence area and sometimes cause the environmental noise problems. In this paper, environmental noise analysis was performed for the power plant with 28 sets of PPS. The initial analysis results showed the some difference between the measurement and analysis because of the inaccurate noise source data. To improve the accuracy of analysis, main noise sources were inversely estimated using the in-situ measurement data in the vicinity of PPS and steam boiler. As the results of re-analysis, the good agreement was obtained and it was concluded that the noise levels exceed the specified noise limit in residence area. In order to reduce the noise, the several methods such as geometry alteration of inlet duct, application of hybrid-type silencer and noise protection barrier were suggested and verified with the confirmed analysis model.

  • PDF