• Title/Summary/Keyword: Noise type

Search Result 2,635, Processing Time 0.031 seconds

Adaptive Bandwidth Algorithm for Optimal Signal Tracking of DGPS Reference Receivers

  • Park, Sang-Hyun;Cho, Deuk-Jae;Seo, Ki-Yeol;Suh, Sang-Hyun
    • Journal of Navigation and Port Research
    • /
    • v.31 no.9
    • /
    • pp.763-769
    • /
    • 2007
  • A narrow loop noise bandwidth method is desirable to reduce the error of raw measurements due to the thermal noise. However, it degrades the performance of GPS initial synchronization such as mean acquisition time. And it restricts the loop noise bandwidth to a fixed value determined by the lower bound of the allowable range of carrier-to-noise power ratio, so that it is difficult to optimally track GPS signal. In order to make up for the weak points of the fixed-type narrow loop noise bandwidth method and simultaneously minimize the error of code and carrier measurements, this paper proposes a stepwise-type adaptive bandwidth algorithm for DGPS reference receivers. In this paper, it is shown that the proposed adaptive bandwidth algorithm can provide more accurate measurements than those of the fixed-type narrow loop noise bandwidth method, in view of analyzing the simulation results between two signal tracking algorithms. This paper also carries out sensitivity analysis of the proposed adaptive bandwidth algorithm due to the estimation uncertainty of carrier-to-noise power ratio. Finally the analysis results are verified by the experiment using GPS simulator.

About Quiet Pavement Technologies in Korean Highway (국내 고속도로의 저소음포장 기술 동향)

  • Mun, Sung-Ho;Hong, Seung-Ho;Cho, Dea-Seung;Kim, Chul-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.491-495
    • /
    • 2008
  • The effects of vehicles and pavement surface types on noise have been investigated at the Korea Expressway Corporation's Test Road along the southbound side of the Jungbu Inland Expressway, South Korea. The study was conducted in 2005 and 2006 through field measurements at nine surface sections of asphalt concrete and Portland cement concrete pavements using eleven vehicles. For the road noise analysis, the sound power levels (PWLs) of combined noise (e.g., tire/pavement interaction noise and power-train noise together) and tire/pavement interaction noise using various vehicles were calculated based on the novel close proximity (NCPX) and pass-by methods. Then, the characteristics of the PWLs were evaluated according to surface type, vehicle type, and vehicle speed. The results show that the PWLs of vehicles are diversely affected by vehicle speed and the condition of the road surface.

  • PDF

A Study on the Prediction and Evaluation of Road Traffic Noise at the Apartment Housing Complex depending on the Types of Adjacent Roads (인접도로의 유형에 따른 공동주택 주거단지의 도로교통소음 전달영향 및 평가)

  • Baek, Geon-Jong;Jang, Gil-Soo;Baek, Eun-Sun
    • KIEAE Journal
    • /
    • v.9 no.1
    • /
    • pp.61-68
    • /
    • 2009
  • In this study, computer simulation program was using to identify the effects of road traffic noise propagation depending on the road types which are very variable in dense city. To achieve this goal, the roads should adjacent to housing complex were categorized into 7 types and propagation noise level should predicted then after simulation of noise exposure population calculation are carried out. Followings the results. First, the road types producing the higher noise level are R1, R2, R3 and R7. The lowest one is R6. And R4, R5 showed that some amount of noise level reduction. Second. the R6 road type which is tunnel shaped showed the highest noise level reduction in vertical distance gap. Last, the order of noise exposure population ratio is R1>R2>R7 and R6 showed the lowest.

Effect of the Properties of Sound Source and Transmission for the Evaluation of Subjective Response by the Exposure Time of Transportation Noise (교통소음의 노출시간에 따른 주관반응 평가시 음원 및 전달 특성의 효과 분석)

  • Kim, Sun-Woo;Kim, Won-Sik;Song, Guk-Gon;Kang, Jong-Ku;Park, Hyeon-Ku
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.3
    • /
    • pp.264-274
    • /
    • 2012
  • Evaluation on the environmental noise is carried out by surveying subjective response of residents with physical measurement of noise during long period in field. Particularly field survey is used to make regulations from the analysis on how many people are annoyed for specific noise level, and laboratory test used to analyze the relationship between physical parameters of noise and subjective responses. In the laboratory controlling the variables is easy but the results could be biased because the condition in room would be different with field. Most of all noise exposure time is considered to be different with real situation, and this study aimed to evaluate the subjective response by exposure time of transportation noise, by applying three kinds of variable how much they give effects on the annoyance as the exposure time is operating condition, windows type and sound level. As a result there was somewhat difference between operating type and annoyance, which is caused by the sound characteristics operated in different condition. However the window type didn't give much effect to the annoyance as much as sound type. This means that the subjective response could give similar result by exposure time even for different window types. Most of all, the main factor affecting subjective response is considered to be the sound level and the exposure time.

The Analysis on the Present Condition of Noise of the Residents Subjective Responses in One-Room Type Multi-Family Housing around Campus (대학주변 원룸형 다가구주택에 있어서 거주자 평가에 의한 소음실태분석)

  • Choi Yoon-Jung
    • Journal of the Korean Home Economics Association
    • /
    • v.41 no.10 s.188
    • /
    • pp.1-13
    • /
    • 2003
  • The purpose of this study is to make clear the present condition and the reason of noise in one-room ape multi-family housing around the campus by residents' subjective responses. The respondents are 104 residents living in one-room ape multi-family housing around the campus. The results are as follows. 1) The residents show relatively non-positive responses at evening and night on the present condition of noise in outdoor and indoor of building or indoor of house unit. 2) The types of outdoor noise of building are checked frequently are 'talking loudness' and 'traffic noise'. 'Walking and talking sounds in stairs and corridors' among the types of indoor noise of building shows highest percentage. They answer 'living equipment noise' and 'water hammer' as major types of indoor noise of house unit.

Study on Acoustic Resonance of Air-Conditioner Fan BLDC Motor (에어컨 팬 BLDC 전동기의 음향공진에 관한 연구)

  • Lee, Hong-Joo;Kim, Kwang-Suk;Kwon, Joong-Hak;Bang, Ki-Chang;Hwang, Sang-Moon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.212-217
    • /
    • 2008
  • Acoustic noises generated during motor operation in mechanical system are from electromagnetic, mechanical, aerodynamic, and electrical sources. For identification of mechanical noise origins, misalignment, unbalance, fan shape, resonance, and vibration modes have been extensively considered to describe noise behavior. An experiment-based approach as well as a mathematical approach needs to be adopted for a realistic study into noise and vibration of the motor, because motor noise characteristics differ from type to type due to various noise sources. In this paper, a brushless DC motor for air-conditioner fan is analyzed by finite element method to identify noise source, and the analysis results are verified by experiments, and sensitivity analysis is performed by design of experiments.

  • PDF

A Study on Radiation Characteristic for Railway Noise (철도소음의 방사특성에 관한 연구)

  • Kim, Jae-Chul;Moon, Kyeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.4
    • /
    • pp.531-536
    • /
    • 2003
  • In order to control the railway noise. we should know the radiation characteristic of the noise during the train passage Generally, the railway noise sources for conventional trains are classified by the rolling noise and power unit noise in tangent track. In this Paper. we describe on a train model that is considered to be a row of point sources to calculate the radiation characteristic The calculation results are compared with short distance measurement of three kinds of trains (EMU, Mookungwha, Saemaul). It is shown that the radiation characteristic of the rolling noise that is major noise source of electric multiple unit is dipole type. We know that characteristic of the engine noise is radiated as the cosine type.

Prediction of Highway Traffic Noise - Estimation of Sound Power Level Emitted by Vehicles (고속도로 교통소음 예측-자동차 주행소음의 음향파워레벨 평가)

  • 조대승;오정한;김진형;김성훈;최태묵;장태순;강희만;이성환
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.8
    • /
    • pp.581-588
    • /
    • 2002
  • Precise highway traffic noise simulation and reduction require the accurate data for sound power levels omitted by vehicles, varied to road surface, traffic speed, vehicle types and makers, different from countries to countries. In this study, we have elaboratively measured Korea highway traffic noise and parameters affecting noise levels at the nearside carriageway edge. From numerical simulation using the measured results for highway traffic noise, we propose not only two correction factors to enhance the accuracy of Korea highway traffic sound power estimation using ASJ Model-1998 but also its typical power spectrum according to road surface type. The measured and predicted highway traffic noise levels using the proposed sound power show little difference within 1 dB.

Development of a Low Noisy Type of Air-line Mask (저소음형 송기마스크 개발)

  • Paik, Eun-Gyu;Kim, Bong-Nyun;Kim, Kwang-Jong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.277-281
    • /
    • 2005
  • Air-line mask is an important personal protective equipment for workers working under hazardous surroundings in which a fixed ventilation system is difficult to be installed. If the air-line mask make loud noise, works wearing the mask may be faced with health problems such as noise induced hearing loss(NIHL). The purpose of this study is to introduce a low noisy technology for workers using air-line mask. A traditional type air-line has been improved to an advanced air-line mask with lesser noise. In the mask, air suppling conduits consists of multi tubes are placed inside of the front of the safety helmet. The noise level reduced from 80dB(A) to less than 80dB(A) when measured by KS A 0701 method at Center for Safety Inspection, Testing and Certification for KOSHA. It is suitable for related regulation[Article 35 of the Industrial Safety and Health Act(Test of Personal Protective Equipment)]. While workers working in noise level of over 90dB(A), they may expose to 82dB(A) or less when they wear the advanced masks. This type masks can be an alternative for works suffering from loud noise generated by traditional air-line masks.

A Study for Comparing Road Noise by Surface Types using NCPX (NCPX를 이용한 도로 표층 유형별 노면 소음 비교 연구)

  • Kang, Won Pyoung;Moon, Hak Ryong
    • International Journal of Highway Engineering
    • /
    • v.15 no.6
    • /
    • pp.61-68
    • /
    • 2013
  • PURPOSES : The purpose of this study is to study the noise reducing effect of Micro Surfacing by comparing general asphalt, longitudinal tining and Slurry Seal. METHODS : This study measures vehicles' noise of each section by the NCPX method that can measure noise between the road surface and the tire at the field. Total sound pressure and sound pressure level by the 1/3 octave band frequency are calculated through the field data of each section. Total sound pressure level is compared by ANOVA test statistically. After ANOVA test, post-hoc test is conducted to know mean difference of surface type by Tukey. RESULTS : As the result of CPB analysis to confirm sound pressure levels by frequency, it was shown that sound pressure levels by frequency are totally similar except for those of frequency bands between 100Hz and 500Hz. The result of ANOVA test and post-hoc test, it was shown that sections of surface type have a difference. The result of Micro Surfacing was lower 2~5dB(A) than other surface type. CONCLUSIONS : It is found that the noise reduction performance of Micro Surfacing was better than other surface type.