• Title/Summary/Keyword: Noise signal ratio

Search Result 3,073, Processing Time 0.035 seconds

Effect of Climate Factors on Tree-Ring Growth of Larix leptolepis Distributed in Korea (기후인자가 일본잎갈나무의 연륜생장에 미치는 영향 분석)

  • Lim, Jong Hwan;Sung, Joo Han;Chun, Jung Hwa;Shin, Man Yong
    • Journal of Korean Society of Forest Science
    • /
    • v.105 no.1
    • /
    • pp.122-131
    • /
    • 2016
  • This study was conducted to analyze the effect of climatic variables on tree-ring growth of Larix leptolepis distributed in Korea by dendroclimatological method. For this, annual tree-ring growth data of Larix leptolepis collected by the $5^{th}$ National Forest Inventory were first organized to analyze yearly growth patterns of the species. To explain the relationship between tree-ring growth of Larix leptolepis and climatic variables, monthly temperature and precipitation data from 1950 to 2010 were compared with tree-ring growth data for each county. When tree-ring growth data were analyzed through cluster analysis based on similarity of climatic conditions, six clusters were identified. In addition, index chronology of Larix leptolepis for each cluster was produced through cross-dating and standardization procedures. The adequacy of index chronologies was tested using basic statistics such as mean sensitivity, auto correlation, signal to noise ratio, and expressed population signal of annual tree-ring growth. Response function analysis was finally conducted to reveal the relationship between tree-ring growth and climatic variables for each cluster. The results of this study are expected to provide valuable information necessary for estimating local growth characteristics of Larix leptolepis and for predicting changes in tree growth patterns caused by climate change.

A Study on the Design of Functional Clothing for Vital sign Monitoring -Based on ECG Sensing Clothing- (생체신호 측정을 위한 기능성 의류의 디자인 연구 -심전도 센싱 의류를 중심으로-)

  • Cho, Ha-Kyung;Song, Ha-Young;Cho, Hyeon-Seong;Goo, Su-Min;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.13 no.3
    • /
    • pp.467-474
    • /
    • 2010
  • Recently, Study of functional clothing for Vital sensing is focused on reducing artifact by human motions, in order to enhance the electrocardiogram(ECG) sensing accuracy. In this study, considering the factors for each element found from the analysis, a 3-lead electrode inside textile embroidered with silver yarn was developed, and draft designs off our types of vital-signal sensing garments, which are 'chest-belt typed' garment, 'cross-typed' garment 'x-typed' garment and 'curved x-typed' garment, were prepared. The draft designs were implemented on a sleeveless male shirt made of an elastic material so that the garment and the electrodes can remain closely attached along the contour of the human body, and the acquired data was sent to the main computer over a wireless network. In order to evaluate the effects caused by body movements and the ECG-sensing capability for each type in static and dynamic states, displacements were measured from one and two dimensional perspectives. ECG measurement evaluation was also performed for Signal-to-noise ratio(SNR) analysis. Applying the experimental results, the draft garment designs were modified and complemented to produce two types of modular approaches 'continuous-attached' and 'insertion-detached' for the ECG-sensing smart clothing.

  • PDF

Optimizing Imaging Conditions in Digital Tomosynthesis for Image-Guided Radiation Therapy (영상유도 방사선 치료를 위한 디지털 단층영상합성법의 촬영조건 최적화에 관한 연구)

  • Youn, Han-Bean;Kim, Jin-Sung;Cho, Min-Kook;Jang, Sun-Young;Song, William Y.;Kim, Ho-Kyung
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.281-290
    • /
    • 2010
  • Cone-beam digital tomosynthesis (CBDT) has greatly been paid attention in the image-guided radiation therapy because of its attractive advantages such as low patient dose and less motion artifact. Image quality of tomograms is, however, dependent on the imaging conditions such as the scan angle (${\beta}_{scan}$) and the number of projection views. In this paper, we describe the principle of CBDT based on filtered-backprojection technique and investigate the optimization of imaging conditions. As a system performance, we have defined the figure-of-merit with a combination of signal difference-to-noise ratio, artifact spread function and floating-point operations which determine the computational load of image reconstruction procedures. From the measurements of disc phantom, which mimics an impulse signal and thus their analyses, it is concluded that the image quality of tomograms obtained from CBDT is improved as the scan angle is wider than 60 degrees with a larger step scan angle (${\Delta}{\beta}$). As a rule of thumb, the system performance is dependent on $\sqrt{{\Delta}{\beta}}{\times}{\beta}^{2.5}_{scan}$. If the exact weighting factors could be assigned to each image-quality metric, we would find the better quantitative imaging conditions.

Development of MRI Phantom for Assessing MR Image Quality (자기공명영상 화질 평가용 팬텀 개발에 관한 연구)

  • Ahn, Chang-Beom;Na, Dong-Gyu;Kim, Kwang-Gi;Kim, Dong-Sung;Kim, In-Su;Lee, Jung-Whee;Hong, Suk-Joo;Byun, Jae-Ho;Khang, Hyun-Soo;Jang, Gi-Won;Song, In-Chan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.89-97
    • /
    • 2006
  • Purpose : To evaluate MR image qualities we developed a new MRI phantom with the fixation structures necessary to position it into coil firmly. Materials and methods : We designed MRI phantom for eight evaluation items such as slice thickness accuracy, high contrast spatial resolution, low contrast object detectability, geometry accuracy, slice position accuracy, image intensity uniformity, percent signal ghosting and signal to noise ratio. For the positioning of phantom at coils, the fixation structures were set up on the surface of phantom. Six different MRI units were used for test the possibility for the clinical application and their image qualities were evaluated. Results : We acquired appropriate MR image qualities enough for the evaluation on all used MR units and confirmed that their evaluations were within reliable values compared to real ones for some items. The positioning of our phantom into head coils with fixation structures worked well for proper imaging. Conclusion : We found that our prototype of MRI phantom had the possibility of clinical application for MR image quality assessment.

  • PDF

Analysing the Relationship Between Tree-Ring Growth of Quercus acutissima and Climatic Variables by Dendroclimatological Method (연륜기후학적 방법에 의한 상수리나무의 연륜생장과 기후인자와의 관계분석)

  • Moon, Na Hyun;Sung, Joo Han;Lim, Jong Hwan;Park, Ko Eun;Shin, Man Yong
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.17 no.2
    • /
    • pp.93-101
    • /
    • 2015
  • This study was conducted to analyze the relationship between tree-ring growth of Quercus acutissima and climatic variables by dendroclimatological method. Annual tree-ring growth data of Quercus acutissima collected by the $5^{th}$ National Forest Inventory (NFI5) were organized to analyze the spatial distribution of the species growth pattern. To explain the relationship between tree-ring growth of Quercus acutissima and climatic variables, monthly temperature and precipitation data from 1950 to 2010 were compared with tree-ring growth data for each county. When tree-ring growth data were analyzed through cluster analysis based on similarity of climatic conditions, four clusters were identified. In addition, index chronology of Quercus acutissima for each cluster was produced through cross-dating and standardization procedures. The adequacy of index chronologies was tested using basic statistics such as mean sensitivity, auto correlation, signal to noise ratio, and expressed population signal of annual tree-ring growth. Response function analysis was conducted to reveal the relationship between tree-ring growth and climatic variables for each cluster. The results of this study are expected to provide valuable information necessary for estimating local growth characteristics of Quercus acutissima and for predicting changes in tree growth patterns caused by climate change.

Multi-Cell Search Scheme for Heterogeneous Networks (이기종 네트워크를 위한 다중 셀 검출 기법)

  • Cho, Yong-Ho;Ko, Hak-lim;Im, Tae-ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.4
    • /
    • pp.395-403
    • /
    • 2016
  • This paper introduces a multi-cell search method for heterogeneous networks (HetNet), in which user equipments need to search multiple cells in its vicinity simultaneously. Due to the difficulty of acquiring channel informations for multiple cells, a non-coherent approach is preferred. In this paper, a non-coherent single-cell search scheme using a weighted vector is proposed, and the successive interference cancellation based multi-cell search algorithm is devised. In order to improve cell search performance, the weighted vector is designed in a way to exploit the general characteristic of wireless channel. Based on the fact that the performance of the proposed single-cell search scheme deviates slowly from the one using the optimal weighted vector, a universal weighted vector is also proposed, which shows the performance close to the optimal ones for various channel environments and signal-to-noise ratio regimes. Simulation results confirm that the proposed multi-cell search algorithm is capable of identifying cells more accurately with the help of the proposed single-cell search scheme, and can detect the remaining cells more effectively by removing the signals of the identified cells from the received signal.

Atmospheric correction by Spectral Shape Matching Method (SSMM): Accounting for horizontal inhomogeneity of the atmosphere

  • Shanmugam Palanisamy;Ahn Yu-Hwan
    • Proceedings of the KSRS Conference
    • /
    • 2006.03a
    • /
    • pp.341-343
    • /
    • 2006
  • The current spectral shape matching method (SSMM), developed by Ahn and Shanmugam (2004), relies on the assumption that the path radiance resulting from scattered photons due to air molecules and aerosols and possibly direct-reflected light from the air-sea interface is spatially homogeneous over the sub-scene of interest, enabling the retrieval of water-leaving radiances ($L_w$) from the satellite ocean color image data. This assumption remains valid for the clear atmospheric conditions, but when the distribution of aerosol loadings varies dramatically the above postulation of spatial homogeneity will be violated. In this study, we present the second version of SSMM which will take into account the horizontal variations of aerosol loading in the correction of atmospheric effects in SeaWiFS ocean color image data. The new version includes models for the correction of the effects of aerosols and Raleigh particles and a method fur computation of diffuse transmittance ($t_{os}$) as similar to SeaWiFS. We tested this method over the different optical environments and compared its effectiveness with the results of standard atmospheric correction (SAC) algorithm (Gordon and Wang, 1994) and those from in-situ observations. Findings revealed that the SAC algorithm appeared to distort the spectral shape of water-leaving radiance spectra in suspended sediments (SS) and algal bloom dominated-areas and frequently yielded underestimated or often negative values in the lower green and blue part of the electromagnetic spectrum. Retrieval of water-leaving radiances in coastal waters with very high sediments, for instance = > 8g $m^{-3}$, was not possible with the SAC algorithm. As the current SAC algorithm does not include models for the Asian aerosols, the water-leaving radiances over the aerosol-dominated areas could not be retrieved from the image and large errors often resulted from an inappropriate extrapolation of the estimated aerosol radiance from two IR bands to visible spectrum. In contrast to the above results, the new SSMM enabled accurate retrieval of water-leaving radiances in a various range of turbid waters with SS concentrations from 1 to 100 g $m^{-3}$ that closely matched with those from the in-situ observations. Regardless of the spectral band, the RMS error deviation was minimum of 0.003 and maximum of 0.46, in contrast with those of 0.26 and 0.81, respectively, for SAC algorithm. The new SSMM also remove all aerosol effects excluding areas for which the signal-to-noise ratio is much lower than the water signal.

  • PDF

Performance analysis and operation simulation of the beamforming antenna applied to cellular CDMA basestation (셀룰러 CDMA 기지국에 beamforming 안테나를 적용하기 위한 동작 시뮬레이션 및 성능해석에 관한 연구)

  • Park, Jae-Jun;Bae, Byeong-Jae;Jang, Tae-Gyu
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.2
    • /
    • pp.32-45
    • /
    • 2000
  • This paper presents the analytic derivation of the SINR, when a linear array antenna is accommodated into the cellular CDMA basestation receiver, in relation to the two major performance effecting factors in beamforming(BF) applications, i. e., the direction selectivity, which refers to the narrowness of the mainbeam width, and the direction-of-arrival(DOA) estimation accuracy. The analytically derived results are compared with the operation simulation of the receiver realized with the several BF algorithms and their agreements are confirmed, consequently verifying the correctness of the analysis and the operation simulation. In order to investigate separately the effects of the errors occurring in the direction estimation and in the interference suppression, which are the two major functional components of general BF algorithms, both the algorithms of steering BF and the minimum- variance- distortionless-response(MVDR) BF are applied to the analysis. A signal model to reflect the spatially scattering phenomenon of the RF waves entering into the .:nay antenna, which directly affects on the accuracy of the BF algorithm's direction estimation, is also suggested in this paper and applied to the analysis and the operation simulation. It is confirmed from the results that the enhancement of the direction selectivity of the away antenna is not desirable in view of both the implementation economy and the BF algorithm's robustness to the erroneous factors. Such a trade-off characteristics is significant in the sense that it can be capitalized to obtain an economic means of BF implementation that does not severely deteriorate its performance while ensuring the robustness to the erroneous effects, consequently manifesting the significance of the analysis results of this paper that can be used as a design reference in developing BF algorithms to the cellular CDMA system.

  • PDF

Estimation of Medical Ultrasound Attenuation using Adaptive Bandpass Filters (적응 대역필터를 이용한 의료 초음파 감쇠 예측)

  • Heo, Seo-Weon;Yi, Joon-Hwan;Kim, Hyung-Suk
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.5
    • /
    • pp.43-51
    • /
    • 2010
  • Attenuation coefficients of medical ultrasound not only reflect the pathological information of tissues scanned but also provide the quantitative information to compensate the decay of backscattered signals for other medical ultrasound parameters. Based on the frequency-selective attenuation property of human tissues, attenuation estimation methods in spectral domain have difficulties for real-time implementation due to the complexicity while estimation methods in time domain do not achieve the compensation for the diffraction effect effectively. In this paper, we propose the modified VSA method, which compensates the diffraction with reference phantom in time domain, using adaptive bandpass filters with decreasing center frequencies along depths. The adaptive bandpass filtering technique minimizes the distortion of relative echogenicity of wideband transmit pulses and maximizes the signal-to-noise ratio due to the random scattering, especially at deeper depths. Since the filtering center frequencies change according to the accumulated attenuation, the proposed algorithm improves estimation accuracy and precision comparing to the fixed filtering method. Computer simulation and experimental results using tissue-mimicking phantoms demonstrate that the distortion of relative echogenicity is decreased at deeper depths, and the accuracy of attenuation estimation is improved by 5.1% and the standard deviation is decreased by 46.9% for the entire scan depth.

Development of OSL Dosimetry Reader (선량 판독용 OSL 측정장치의 개발)

  • Park, Chang-Young;Chung, Ki-Soo;Lee, Jong-Duk;Chang, In-Su;Lee, Jung-Il;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.10-15
    • /
    • 2012
  • Design and performance test results of a newly developed optically stimulated luminescence (OSL) measurement system are presented in this paper. Generally, different types of optical filters are used in OSL reader system to minimize the interference of the stimulation light in the OSL signal. For optically stimulation of $Al_2O_3:C$, we have arrived at an optimal combination of the filters, i.e., GG420 filter for filtering the stimulating light source, and a combined UG11 and BG39 filter at the detecting window (PMT). By using a high luminance blue LED (Luxeon V), sufficient luminous intensity could be obtained for optically stimulation. By using various control boards, the OSL reader device was successfully interfaced with a personal computer. A software was developed to deliver required commands to operate the OSL reader by using the LabView program (National Instruments, Inc.). In order to evaluate the reliability and the reproducibility of newly designed-OSL reader. Performance testing of the OSL reader was carried out for OSL efficiency, OSL decay curve and signal to noise ratio of the standard $Al_2O_3:C$ OSL material. It was found to be comparable with that of commercial Riso reader system.