• Title/Summary/Keyword: Noise regulation

Search Result 212, Processing Time 0.022 seconds

Analysis and Compensation of Current Measurement Error in Digitally Controlled AC Drives (디지털 제어 교류 전동기 구동시스템의 전류 측정 오차 해석 및 보상)

  • 송승호;최종우;설승기
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.5
    • /
    • pp.462-473
    • /
    • 1999
  • This paper addresses the current measurement issue of all digital field oriented control of ac motors. The p paper focuses on the effect of low-pass filter and also on the sampling of the fundamental component of the m motor current. The low-pass filter, which suppresses the switching noise of the motor current, introduces v variable phase delay according to the current ripple frequency. It is shown that the current sampling error c consists of the fundamental component and high frL'quency ripple components. In this paper, the dependency of t this current sampling e$\pi$or on the reference voltage vector is investigated analytically and a sampling technique i is proposed to minimize the error. The work is based on the three phase symmetry pulse width modulation l inverter driving an induction machine. With this technique, the bandwidth of current regulator can be extended t to the limit given by the switching frequency of the inverter and more precise torque regulation is possible.

  • PDF

Cooperative Spectrum Sensing with Ad-Hoc Network for Cognitive Radio (애드 혹 네트워크에서의 협력 센싱 기법의 성능 분석)

  • Lee, Kyung-Sun;Kim, Yoon-Hyun;Kim, Jin-Young
    • Journal of Satellite, Information and Communications
    • /
    • v.6 no.1
    • /
    • pp.75-79
    • /
    • 2011
  • Wireless devices can communicate between each other without existing infrastructure in mobile Ad-hod network. Ad hoc networks can be used under difficult conditions, where it is difficult to construct infrastructures, such as shadowing areas, disaster areas, war area, and so on. In order to support to considerable and various wireless services, more spectrum resources are needed. However, efficient utilization of the frequency resource is difficult because of spectrum scarcity and the conventional frequency regulation. Ad-hoc networks employing cognitive radio (CR) system that guarantee high spectrum utilization provide effective way to increase the network capacity. In this paper, we simulate and compare the performance of conventional single and cooperative spectrum sensing with CR system using ad-hoc networks in additive white Gaussian noise (AWGN) and Rayleigh channel model. And we demonstrate performance improvement by analyzing the system performance.

Study on Performance of an Fuel Pressure Regulator under Failure Condition in an Electric Control Diesel Engine (전자제어 디젤엔진의 연료압력 레귤레이터 고장에 따른 진단 및 성능 연구)

  • Kim, Tae-Jung;Cho, Hong-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.1677-1683
    • /
    • 2015
  • To cope with exhaust gas regulation, Diesel engine applied to electronic control system. As it accurately regulated the injected fuel mass and the fuel efficiency and the output are increased but the noise and the vibration are decreased. In order to keep the performance of Electronic Diesel Control System, it is important to accurately control the fuel pressure. However, when the regulator of fuel pressure is not controlled properly, the failure phenomenons(starting failure, staring delay, accelerated failure, engine mismatch et al.) occur because the fuel pressure is not stabilize. In this study, effects on a fuel pressure, engine rotating speed according to the control rate of fuel-pressure regulator are investigated in order to analyzed the performance variation with failure of fuel-pressure regulator. As a result, when the control rate of a fuel-pressure regulator is 4%~6% lower than that of standard condition, the variation of engine's rpm and return fuel flow is increased, and the abnormal condition was occurred. Besides, it is possible to diagnose the failures on fuel-pressure regulator under these conditions.

EMC Measurements above 1 GHz Using an Offset Parabola Antenna System (옵셋 파라볼라 안테나를 이용한 1 GHz 이상에서의 전자파 적합성 평가)

  • Chung, Yeon-Choon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.10
    • /
    • pp.1184-1193
    • /
    • 2010
  • The upper frequency of international EMC regulations is being expanded above 1 GHz. Radiated emissions above 1 GHz are different from those below 1 GHz that is existing upper regulation frequency, and which have lower field strength and sharper and tilted beam-width, relatively. In this paper, an effective evaluation method to be used above 1 GHz is studied using an offset parabola antenna system having a double-ridged horn antenna as a feed. First, simple model is proposed for calculating antenna factor and field uniformity of the parabola antenna system, and then real radiated emission and radiated susceptibility measurements are performed using a constant noise emitter and the suggested antenna system. The results show that the proposed antenna system has higher gain and power efficiency, and wider field uniformity relative to a conventional double-ridged horn antenna. Therefore, it is confirmed that the proposed system can be effectively used for EMC measurements above 1 GHz.

AC-DC Converter Control for Power Factor Correction of Inverter Air Conditioner System (인버터 에어컨 시스템의 역률보상을 위한 AC-DC 컨버터 제어)

  • Park, Gwi-Geun;Choi, Jae-Weon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.2
    • /
    • pp.154-162
    • /
    • 2007
  • In this paper, we propose a new AC-DC converter control method to comply with harmonics regulation(IEC 61000-3) effective for the inverter system of an air conditioner whose power consumption is less than 2,500W. There are many different ways of AC-DC converter control, but this paper focuses on the converter control method that is adopting an input reactor with low cost silicon steel core to strengthen cost competitiveness of the manufacturer. The proposed control method controls input current every half cycle of the line frequency to get unit power factor and at the same time to reduce switching loss of devices and acoustic noise from reactor. This kind of converter is known as a Partial Switching Converter(PSC). In this study, theoretical analysis of the PSC has been performed using Matlab/Simulink while a 16-bit micro-processor based converter has been used to perform the experimental analysis. In the theoretical analysis, electrical circuit models and equations of the PSC are derived and simulated. In the experiments, micro-processor controls input current to keep the power factor above 0.95 by reducing the phase difference between input voltage and current and at the same time to maintain a reference DC-link voltage against voltage drop which depends on DC-link load. Therefore it becomes possible to comply with harmonic regulations while the power factor is maximized by optimizing the time of current flow through the input reactor for every half cycle of line frequency.

Technical Trend Analysis of a Fault Monitoring System (단층감시시스템 기술현황 분석)

  • Lee, Hyun-Woo
    • The Journal of Engineering Geology
    • /
    • v.21 no.1
    • /
    • pp.87-95
    • /
    • 2011
  • To provide regulatory standards and technical guides that are likely to be required for the Fault Monitoring System (FMS), soon to be installed and operated at the Shin-Wolsong NPP #1, 2 site, technical trend analysis was performed for currently operating geodetic and/or earthquake monitoring systems and activities worldwide, resulting in the identification of several items of concern regarding the design, installation, and operation of FMS at Korean sites. The items are as follows: 1) characterization of site-specific properties (including local noise), 2) selection of measuring instruments/design of appropriate sensitivity for the tectonic behavior of the target, 3) data/electricity backup system, 4) cross-checking and/or cross-referencing system to enhance data quality and credibility, 5) transparent data operation and open-to-the-public policy, and 6) long-term operation in a stable environment.

Quantitative Profiling of Dual Phosphorylation of Fus3 MAP Kinase in Saccharomyces cerevisiae

  • Hur, Jae-Young;Kang, Gum-Yong;Choi, Min-Yeon;Jung, Jin Woo;Kim, Kwang-Pyo;Park, Sang-Hyun
    • Molecules and Cells
    • /
    • v.26 no.1
    • /
    • pp.41-47
    • /
    • 2008
  • Mitogen-activated protein kinase (MAPK) signaling is a crucial component of eukaryotic cells; it plays an important role in responses to extracelluar stimuli and in the regulation of various cellular activities. The signaling cascade is evolutionarily conserved in the eukaryotic kingdom from yeast to human. In response to a variety of extracellular signals, MAPK activity is known to be regulated via phosphorylation of a conserved $T{\times}Y$ motif at the activation loop in which both threonine and tyrosine residues are phosphorylated by the upstream kinase. However, the mechanism by which both residues are phosphorylated continues to remain elusive. In the budding yeast, Saccharomyces cerevisiae, Fus3 MAPK is involved in the mating signaling pathway. In order to elucidate the functional mechanism of MAPK activation, we quantitatively profiled phosphorylation of the $T{\times}Y$ motif in Fus3 using mass spectrometry (MS). We used synthetic heavy stable isotope-labeled phosphopeptides and nonphosphopeptides corresponding to the proteolytic $T{\times}Y$ motif of Fus3 and accompanying data-dependent tandem MS to quantitatively monitor dynamic changes in the phosphorylation events of MAPK. Phosphospecific immunoblotting and the MS data suggested that the tyrosine residue is dynamically phosphorylated upon stimulation and that this leads to dual phosphorylation. In contrast, the magnitude of threonine phosphorylation did not change significantly. However, the absence of a threonine residue leads to hyperphosphorylation of the tyrosine residue in the unstimulated condition, suggesting that the threonine residue contributes to the control of signaling noise.

Traffic Sign Recognition by the Variant-Compensation and Circular Tracing (변형 보정과 원형 추적법에 의한 교통 표지판 인식)

  • Lee, Woo-Beom
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.3
    • /
    • pp.188-194
    • /
    • 2008
  • We propose the new method for the traffic signs recognition that is one of the DAS(Driving assistance system) in the intelligent vehicle. Our approach estimates a varied degree by using a geometric method from the varied traffic signs in noise, rotation and size, and extracts the recognition symbol from the compensated traffic sign for a recognition by using the sequential color-based clustering. This proposed clustering method classify the traffic sign into the attention, regulation, indication, and auxiliary class. Also, The circular tracing method is used for the final traffic sign recognition. To evaluate the effectiveness of the proposed method, varied traffic signs were built. As a result, The proposed method show that the 95 % recognition rate for a single variation, and 93 % recognition rate for a mixed variation.

  • PDF

Analysis of the Exterior Spatial Organization and Residents\\\\` Satisfaction Degree to the Apartment Complex in Teagu (대구시 아파트 단지의 외부공간구성 및 만족도에 관하여)

  • 권태식;김영수
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.18 no.1
    • /
    • pp.53-68
    • /
    • 1990
  • The purpose of this study was to establish the more rational and practical basic theory for the landscape planning in the aparment complex. In this study, the actual conditions of exterior space, the residens' satisfaction degree and the correlation between exterior space and the residents' satisfaction defree were investigated and analyzed on the 13apartment complexes in Taegu City. Through the statistical analysis, the main results were obtained as fellows : It was found that the size of green area ratio in the apartment complexes were in the order of Jugong Apt. (Korean Housing Corporation), Siyoung Apt. (City Operation), Minyoung high-rise Apt. (Private Business) and Minyoung low-rise Apt. (Private Business) complex. The highest ratio of footway and Parking area were shown in Minyoung high-rise Apt. complex. The important factors at the exterior space of apartment complex were composed by 6 major factors, importance degrees of which are Visual, Practical, Convenient, Sentimental, Recreational and Spatial factors for teenagers in orders. The residents' satisfaction degrees to the exterior space were highly correlated with the spatil organization, size of green area and quantity of trees, view, management situation, defensibility of outside noise, rest place, water landscapings by turns. In order to get more than the average satisfaction degree 18 exterior space, the green area should be occupied by 35% of the apartment complex area and more than 76% of the green area (i. e. 16% of the apartment complex area) should be planted with trees. In the Taegu City regulation, the ratio of tree composition is proposed for only the number of tree. But it was shown that the satifaction degree are more correlated with the species and afforestation of trees than the nuts her of trees in this study. therefore, the species of tree and the afforestation of tree should be considered when the landscape planning of the apartment complex begins. It was found that the ratio of afforestation to make the more desirable exterior space In the apartment complex shoule be 8 to 2 in the ratio of arbor to shrub. It was also required that 30 species of arbor and 15 species of shrub should be planted for the more desirable landscape of the apartment complex.

  • PDF

Process and Results of Seoul Metropolitan Government's Environmental Health Policy Road Map (서울시 환경보건정책 로드맵 수립)

  • Lim, Ji-Ae;Kwon, Ho-Jang;Kim, Shinbum;Chou, Youngeun;Gu, Seulgi;Jeong, Hoi-Seong;Kim, Myung Han;Choi, Kyungho
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.5
    • /
    • pp.425-434
    • /
    • 2014
  • Objectives: The purpose of this study is to introduce the establishment process and results of the Seoul Metropolitan Government's road map on environmental health policy. Methods: The process consisted of expert group meetings, civic participation, research, and questionnaire survey for priority environmental health policy agenda items in Seoul. Results: The announced vision for the environmental health policy was "a healthy environment, safety in Seoul". This policy was established in order to define environment health policy initiatives for a period of five years with an aim to protect Seoul citizens' health from hazardous environmental factors. The resulting Seoul environmental health policy consisted of four areas and 16 key agenda items. The four areas were "Protection for children against hazardous materials", "Enhancement of health and safety of all", "Carcinogen-free and endocrine-disrupting chemical-free Seoul (reducing environmental exposure to hazardous materials), and "Establish the foundation of environmental health policy". Sixteen key agenda items include the enhancement of management of spaces for children, certification of environmental health status at schools, establishment of a unit responsible for the environmental health of children, strengthening environmental health management for susceptible populations (children, the aged, and the socioeconomically vulnerable), management of hazardous materials, physical hazardous factors (noise, radiation, etc.), indoor air quality, and the enhancement of monitoring, research, and regulation of environment health. Conclusion: The Seoul Metropolitan Government established an environmental health policy road map for a five-year period (2013-2017). To implement this environmental health policy, budget allocation, and detailed execution plans are required.