• Title/Summary/Keyword: Noise protection

Search Result 337, Processing Time 0.032 seconds

ENVIRONMENTAL NOISE POLICIES AND NOISE CONTROL PRACTICE IN CHINA

  • Tian, Jing
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.25-32
    • /
    • 2005
  • In China, environmental noise policies are composed of correlated laws adopted by the Standing Committee of the National People's Congress and promulgated by the President of the country, regulations promulgated by the State Council and/or local government, standards issued by the Standardization Administration Committee (SAC) under the State Council. The laws mainly include the 'Environmental Protection Law' and the 'Law on Prevention and Control of Pollution From Environmental Noise' Regulations are often applied to a special noise pollution phenomenon of wide influence. They are generally only effective in a given area and/or a specific period. Tens of correlated standards specify the noise level limits of different functional zones of land use and of different equipment, machines, devices, appliances etc., and the measurement methods. In this presentation, a brief introduction to these policies and their operations is given and discussed. The conclusion is that the policies supply an effective legislative basis for environmental noise prevention and control in China, but still a lot of work should be conducted and completed to strive for a quiet society.

  • PDF

A Study on the Countermeasure and Trouble-Examples by Noise in Control Equipment System (제어설비 계통의 노이즈장해 사례 및 대척에 관한 연구)

  • Yoo, Sang-Bong;Kim, Hong-Ju;Lee, Ho-Sung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.325-330
    • /
    • 2005
  • Recently an increase of sensor and power trandusers in control equipment system has caused many kinds of noise. These kinds of noise came out the mis-operation equipment and demage program memories of control circuits. In this paper, the noise generation of control equipment system han been measured and analyzed. Additionally, the effective protection equipments to reduce noise like as Noise Cut Transformer, Equipotential Bonding, Power Noise Rejector, Noise Filter has been applied and proposed the measured results.

  • PDF

Analytical Procedures for Designing an Optimal Noise Hazard Prevention Program

  • Asawarungsaengkul, Krisada;Nanthavanij, Suebsak
    • Industrial Engineering and Management Systems
    • /
    • v.4 no.2
    • /
    • pp.165-175
    • /
    • 2005
  • Two extreme and one mixed procedures for designing a noise hazard prevention program are discussed in this paper. The two extreme design procedures (engineering-based and HPD-based) yield upper and lower bounds of the total noise control cost, respectively; while the mixed design procedure provides an optimal noise hazard prevention program within a given total budget. The upper bound of the workforce size for job rotation is approximated using a heuristic procedure. Six optimization models are developed and utilized by the mixed procedure to eliminate or reduce excessive noise levels (or noise exposures) in an industrial workplace. The mixed procedure also follows the OSHA’s hierarchy of noise control. A numerical example is given to demonstrate the application of the proposed design procedures.

A Study on Noise in Waste Facilities (폐기물 소각시설 내부 소음에 관한 연구)

  • Seo, Byung-Suk;Park, Ro-Gook;Jeon, Yong-Han
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.2
    • /
    • pp.15-21
    • /
    • 2020
  • Industrial facilities need design to predict and reduce noise from design to prevent and reduce noise. The purpose of this study is to predict worker's environment and evaluate safety by analyzing noise inside underground blower room and air compressor room with fluid machinery in waste facility. This waste incineration facility was analyzed based on the ground floor, ground floor blower chamber, and air compressor chamber. The results of SPL(Sound Pressure Level) analysis at 1.5m away, which are frequently used to measure the SPL as a noise source, are as follows. SPL of basement level: 46.80[dB], SPL of ground layer: 48.57[dB]. As a result, it was expected that the noise level would be considerably lower than the 8 hours 50[dB] noise exposure per day.

Task-specific Noise Exposure Assessment of Firefighters

  • Kang, Taesun
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.6
    • /
    • pp.569-576
    • /
    • 2019
  • Objectives: The main purpose of this study was to assess firefighters' daily personal noise exposure and explore noise levels related to specific tasks and their contributions to total noise exposure using 24-hour full-shift noise exposure measurements with task-based data. Methods: Noise exposure was assessed for eight firefighters (two rescuers, two drivers, and four suppressors) using time-activity diaries. We collected a total of 24 full-shift personal noise sample sets (three samples per a firefighter). The 24-hour shift-adjusted daily personal noise exposure level (Lep,d), eight weekly personal noise exposures (Leq,w), and 40 task-specific Leq values (Leq activity) were calculated via the ISO/NIOSH method. Results: The firefighter noise-sample datasets showed that most firefighters are exposed to noise levels above EU recommended levels at a low-action value. The highest noise exposure was for rescuers, followed by drivers and suppressors. Noise measurements with time-at-task information revealed that 82.3% of noise exposure occurred when checking equipment and responding to fire or emergency calls. Conclusions: The results indicate that firefighters are at risk of noise-induced hearing loss. Therefore, efforts at noise-control are necessary for their protection. This task-specific noise exposure assessment also shows that protective measures should be focused on certain tasks, such as checking and testing equipment.

Individual Fit Testing of Hearing Protection Devices Based on Microphone in Real Ear

  • Biabani, Azam;Aliabadi, Mohsen;Golmohammadi, Rostam;Farhadian, Maryam
    • Safety and Health at Work
    • /
    • v.8 no.4
    • /
    • pp.364-370
    • /
    • 2017
  • Background: Labeled noise reduction (NR) data presented by manufacturers are considered one of the main challenging issues for occupational experts in employing hearing protection devices (HPDs). This study aimed to determine the actual NR data of typical HPDs using the objective fit testing method with a microphone in real ear (MIRE) method. Methods: Five available commercially earmuff protectors were investigated in 30 workers exposed to reference noise source according to the standard method, ISO 11904-1. Personal attenuation rating (PAR) of the earmuffs was measured based on the MIRE method using a noise dosimeter (SVANTEK, model SV102). Results: The results showed that means of PAR of the earmuffs are from 49% to 86% of the nominal NR rating. The PAR values of earmuffs when a typical eyewear was worn differed statistically (p < 0.05). It is revealed that a typical safety eyewear can reduce the mean of the PAR value by approximately 2.5 dB. The results also showed that measurements based on the MIRE method resulted in low variability. The variability in NR values between individuals, within individuals, and within earmuffs was not the statistically significant (p > 0.05). Conclusion: This study could provide local individual fit data. Ergonomic aspects of the earmuffs and different levels of users experience and awareness can be considered the main factors affecting individual fitting compared with the laboratory condition for acquiring the labeled NR data. Based on the obtained fit testing results, the field application of MIRE can be employed for complementary studies in real workstations while workers perform their regular work duties.

A Study on Abnormal Noise Reduction of Scroll Compressor (Scroll Compressor의 이상 소음 저감에 관한 연구)

  • Ahn, B.H.;Kim, Y.S.
    • Journal of Power System Engineering
    • /
    • v.3 no.4
    • /
    • pp.28-35
    • /
    • 1999
  • An application of scroll compressor to the residential air conditioning and heat pump markets has generated many reliability problem, especially abnormal noise. Most of these noise problems is due to the check valve and compliance between FS(Fixed Scroll) and OS(Orbiting Scroll). FS and OS are the main parts of scroll compressor and are the main pumping part. But check valve has the role of protection of reverse rotation of OS when power is off. Check valve have several noise problems. Among them, shut down noise and valve movement noise is more than severe than any other problem. In this paper covers with these two noise problem.

  • PDF

Study of Muffler for Rotary Compressor by Taguchi Method Viewpoint (회전형 압축기용 머플러의 연구 (1) : 다꾸찌 기법 관점에서)

  • 박성근
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.542-547
    • /
    • 1998
  • As the concern for a global energy conservation and environmental protection are increasing, it has been more important thing to correspond with CFC depletion. Alternate refrigerants have merit such as lower global warming effect, but also have demerits such as lower efficiency, miscibility, increasing noise and poor reliability problems. Then we have to develop more efficient, silent and robust compressors to satisfying world-wide demand. In this paper, parametric study on rotary compressor muffler for a room air-conditioner was carried out to investigate the effect of important design variables on noise by using Taguchi robust design method with signal-to-noise(S/N) ratio. Taguchi method seems to be helpful for finding optimum value of design variables for noise level. We also applied neural network to find optimal value of design variables.

  • PDF