A study on the standard for determining airborne sound insulation performance of sound barrier panels (방음판의 음향투과손실 측정규격에 관한 연구)

  • Oh, Yang Ki
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.3
    • /
    • pp.302-311
    • /
    • 2022
  • Sound barrier walls are one of the most effective alternatives for reducing environmental noise on roads and railways in the city center. The insertion loss of the sound barrier against road traffic noise is the sum of the sound transmission loss, sound absorption loss, and sound energy reduction due to the diffraction attenuation of the sound barrier. The sound transmission loss of the sound barrier is one of the important factors that determine the insertion loss of the sound barrier and is a basic indicator that determines the performance of the sound barrier. Nevertheless, there is not a separate standard in Korea for measuring the acoustic transmission loss of sound barrier panels. There are only a few conditions in KS F 4770 series that stipulates on the general material of sound barrier panels. This thesis examines the necessity of the acoustic transmission loss measurement and evaluation standards of sound barrier walls, and seeks a measurement method in a free sound field (anechoic chamber) sound receiving room considering the characteristics of sound barrier walls installed in external spaces, unlike indoor building materials. In addition, a single number evaluation method using a reference spectrum was proposed so that the sound insulation effect according to various installation places such as roadside or railroad side can be easily displayed.

A Study on the Working Clothes in the Changwon National Industrial Complex -Considering Clothing Performance and Motion Factors in Work Places- (창원국가산업공단 근로자들 작업복 착용실태에 관한 연구 -작업분야별 작업복 기능성 및 동작요인 중심으로-)

  • Park, Gin-Ah;Bae, Hyun-Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.10
    • /
    • pp.1571-1583
    • /
    • 2008
  • The study aimed to investigate the actual condition of working clothes in the Changwon National Industrial Complex and to analyze the industrial workers' satisfaction with and preference to the working clothes in terms of the clothing performance and work motion factors. 1 major companies in machinery, automotive, industrial engineering, shipbuilding and rolling stock industries located in the industrial complex were selected as the subject firms. Approximately 900 workers responded to the questionnaire designed for the research and the results derived from the research were as follows. (1) The subject employees were divided into 4 work groups, i.e. the $1^{st}$ work group: managerial, general affairs, sales, production planning; the $2^{nd}$ group: quality assurance, material planning and distribution, product inspection; the $3^{rd}$ group: electric, facilities, machinery, vehicles; and the $4^{th}$ group: cutting, pressing, rolling, welding and coating. (2) The significant work environmental factors considered by all work groups were air ventilation, noise and dust factors and in particular, the most dissatisfied factors evaluated by manufacture workers were insulation, noise, dust and vibration. (3) According to the employees' work motion evaluation, the work motion diversity and frequency increased in proportion to the degree of work intensity. Besides, manufacture workers more frequently wore the working clothes even during the off-duty hours comparing to the evaluation of the other work groups. (4) The most important clothing performance factors considered by manufacture work groups were perspiration absorption, stretch, air permeability, tactile sense softness, soil proof in order.

Partial Discharge Detection of High Voltage Switchgear Using a Ultra High Frequency Sensor

  • Shin, Jong-Yeol;Lee, Young-Sang;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.4
    • /
    • pp.211-215
    • /
    • 2013
  • Partial discharge diagnosis techniques using ultra high frequencies do not affect load movement, because there is no interruption of power. Consequently, these techniques are popular among the prevention diagnosis methods. For the first time, this measurement technique has been applied to the GIS, and has been tested by applying an extra high voltage switchboard. This particular technique makes it easy to measure in the live state, and is not affected by the noise generated by analyzing the causes of faults ? thereby making risk analysis possible. It is reported that the analysis data and the evaluation of the risk level are improved, especially for poor location, and that the measurement of Ultra high frequency (UHF) partial discharge of the real live wire in industrial switchgear is spectacular. Partial discharge diagnosis techniques by using the Ultra High Frequency sensor have been recently highlighted, and it is verified by applying them to the GIS. This has become one of the new and various power equipment techniques. Diagnosis using a UHF sensor is easy to measure, and waveform analysis is already standardized, due to numerous past case experiments. This technique is currently active in research and development, and commercialization is becoming a reality. Another aspect of this technique is that it can determine the occurrences and types of partial discharge, by the application diagnosis for live wire of ultra high voltage switchgear. Measured data by using the UHF partial discharge techniques for ultra high voltage switchgear was obtained from 200 places in Gumi, Yeosu, Taiwan and China's semiconductor plants, and also the partial discharge signals at 15 other places were found. It was confirmed that the partial discharge signal was destroyed by improving the work of junction bolt tightening check, and the cable head reinforcement insulation at 8 places with a possibility for preventing the interruption of service. Also, it was confirmed that the UHF partial discharge measurement techniques are also a prevention diagnosis method in actual industrial sites. The measured field data and the usage of the research for risk assessment techniques of the live wire status of power equipment make a valuable database for future improvements.

Acoustic Loads Reduction of Composite Plates for Nose Fairing Structure (노즈 페어링 구조용 복합재 평판의 음향 하중 저감 특성)

  • 박순홍;공철원;장영순;이영무
    • Composites Research
    • /
    • v.17 no.3
    • /
    • pp.15-22
    • /
    • 2004
  • Acoustic load generated by rocket propulsion system is one of major dynamic loads during lift-off phase so that it causes the structural failure and electronic malfunction of payloads. Acoustic loads can be greatly reduced by an appropriate acoustical design of nose faring structures. This paper deals with the acoustical design of the nose fairing structure for launch vehicle. It is well known that a honeycomb sandwich structure is a poor sound insulator because of its high specific stiffness. In this paper, the sound transmission characteristics of four kinds of honeycomb structures for noise fairing were investigated by means of numerical and experimental ways. In order to estimate transmission loss, infinite plate theory by Moore and Lyon and statistical energy analysis (SEA) method were used. The predicted results showed a good agreement with measured ones. These enabled us to determine a proper core material for nose fairing, which shows good sound insulation performance per weight.

A Study on the Application of Finishing Materials According to the Locational Function of the Chapel in Church Space (교회공간 예배실의 위치적 기능에 따른 마감재 적용 연구)

  • Yeo, Mi;Lee, Chang No
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.1
    • /
    • pp.178-188
    • /
    • 2015
  • This study has the main objective of being of help as a reference data for the application of the finishing materials when designing the interior of the chapel of the church space through analysis of the finishing materials against the chapels of church space which has complex function. As precedent studies for this, the composition of the function and concept of the church space was surveyed and the complex function of the church space was surveyed. The theoretical surveyed was performed according to the casual composition, behavior of the community and role and location of the duties of the church members. The case objects were 10 chapels constructed by 5 professional interior design companies. The content of the analysis was the finishing materials in the chapels and their application characteristics. The detailed considerations to be referred to when designing the interior of the chapels of church space in the future were proposed. The analysis result of the application of the finishing materials according to the locational function of the chapels of church space can be explained as follows. First, the platform area was the characteristic of applying finishing materials which induce visual immersion. As for the floor materials in the platform, in order to minimize the floor sound and vibration phenomenon occurring during movements, noise insulation and dust protection rubber sheet was place and on top of it the floor or the carpet was placed. Second, the Choir area had the difficult problem of having to consider the appropriate sound absorption occurring due to the proliferation of sound and performance of classical instruments at the same time. However, in the case, this problem was solved through the sculptures of convex shape. Third, since the scheelite is a space where many people move around, the finishing material which absorbs sound was mainly used. Fourth, the entrance area was composed of thick wall materials compared to other walls, and the sound absorption character was most significantly considered when applying the finishing material. Fifth, the broadcasting room was composed either in independent type or an open type and performed its function and the main finishing materials was transparent glass which was highest use frequency.