• 제목/요약/키워드: Noise gating method

검색결과 11건 처리시간 0.024초

적응 디지털 필터 기반의 MRI Cardiac Gating을 위한 심전도 신호의 MR Gradient 잡음 최소화 방법 (Minimizing MR Gradient Artefacts on ECG Signals for Cardiac Gating based on an Adaptive Digital Filter)

  • 박호동;장봉렬;이경중
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.817-818
    • /
    • 2006
  • In Magnetic Resonance Imaging(MRI), the QRS complex of ECG is used as a trigger signal for MRI scan. But, gradient and RF(radio frequency) artifacts which are caused to static and dynamic field in MRI scanner cause interference in the ECG. Also, the signal shape of theses artifacts can be similar to the QRS-complex, causing possible misinterpretation during patient monitoring and false gating of the MRI. In case of using general FIR or IIR band-pass filters for minimizing the artifacts, artifact-reduction-ratio is not excellent. So, an adaptive real-time digital filter is proposed for reduction of noise by gradient and RF(radio frequency) artifacts. The proposed filter for MRI-Gating is based on the noise-canceller with NLMS(Normalized Least Mean Square) algorithm. The reference signals of the adaptive noise canceller are a combination of the noisy three channel ECG signals. In conclusions, the proposed method showed the acceptable quality of ECG signal with sufficient SNR for gating the MRI and possibility of real time implementation.

  • PDF

온라인 변압기 부분방전 측정기법 적용 (An Application of the On Line Partial Discharge Measurement Method in Transformer)

  • 권동진
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권8호
    • /
    • pp.394-400
    • /
    • 2001
  • This paper describes an application of the on line partial discharge measurement method in operating transformer. In the operating transformer, the partial discharge signal may be superimposed by radio intereference voltage(RIV) and pulse shaped noise signals generated by external corona. The partial discharge quantity showed about 3,800pC due to very high sinusoidal interferences at the measuring impedance terminal of the transformer bushing tap. In order to reject these noises, this paper applied RIV filter, band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,800pC to 160pC.

  • PDF

실험계획법에 의한 승강기용 구동부 주조품의 다이캐스팅 탕구방안 최적화 (Optimal Gating System Design of Escalator Step Die Casting Part by Using Taguchi Method)

  • 정원제;윤형표;홍순국;박익민
    • 한국주조공학회지
    • /
    • 제20권2호
    • /
    • pp.97-103
    • /
    • 2000
  • In this study, a design of experiment, Taguchi method, was applied to optimize gating system design of escalator step die casting parts. Six shape factors which affect filling sequence of melt are adopted and divided into two levels respectively. Initial feeding differences of melt which were calculated by using S/N(signal-to-noise) ratio in each condition were demonstrated with the simulation of Flow-3D software program. Variations of S/N ratio according to shape factors were obtained and the optimal condition of gating system could also be obtained. It could be found that width of gate, contact angle of gate, thickness of runner are more effective factors on the filling sequence of melt than the others in this case of escalator step die casting parts. It showed that the economical gating system and sound filling sequence of melt were obtained by using Taguchi method.

  • PDF

MRI 내에서의 생체신호 측정 시스템 설계 (Design of Bio-signal Acquisition System in MRI Environment)

  • 장봉렬;박호동;이경중
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.871-872
    • /
    • 2006
  • In this paper, we designed bio-signal acquisition system in Magnetic Resonance Imager(MRI) Environment. In MRI Environment, Strong RF Pulse and Gradient Field Switching Noise exist and can cause distortion of ECG. By this, ECG can lose their important information. So we proposed a bio-signal acquisition system with robust immunity to RF pulse and gradient switching noise. In conclusions, the proposed system showed the prevent saturation of measured biosignal and possibility of using cardiac gating and respiration gating method.

  • PDF

이중 에너지 전산화 단층촬영 ECG Gating High Pitch Chest Pain Protocol 모드를 이용한 방사선량과 영상 품질에 관한 연구 (A Study on Radiation Dose and Image Quality using Dual Energy Computed Tomography ECG Gating High Pitch Chest Pain Protocol Mode)

  • 김경립;성순기;김창현;곽종혁
    • 한국방사선학회논문지
    • /
    • 제16권1호
    • /
    • pp.7-13
    • /
    • 2022
  • 본 연구는 심전도 게이팅을 한 방법과 심전도 게이팅 없이 검사하는 방법으로 검사하여 대동맥 뿌리 영상을 비교하는 것이며 high pitch(flash) chest pain protocol 방법으로 검사한 영상들과 기존의 방식으로 심전도 게이팅 없이 검사한 환자의 대동맥 뿌리 영상의 질환 유무를 관찰하였다. High pitch(flash) chest pain protocol과 일반적인 chest pain protocol로 AAPM 팬텀을 스캔하였으며 이렇게 획득된 팬텀 영상을 가지고 동일한 영상 품질을 가지는 파라메타 값을 조절하고 방사선량, 즉 CTDI 값을 비교해 보았다. 심전도 게이팅을 함으로 해서 상행대동맥의 이미지 왜곡은 기존의 심전도 게이팅을 하지 않은 검사방법보다 월등하게 감소시킬 수 있었고 대동맥 뿌리의 영상 품질은 향상되었다. 영상 이미지 품질의 차이를 보이지 않는 파라메타 범위 내에서, high-pitch chest pain protocol로 검사하였을 때 CTDI 값이 더 낮게 나왔으므로 방사선량 감소에도 이점이 있음을 알 수 있었다. 심장과 관련된 분야에서 선량 감소 모드를 이용하여 대동맥 박리와 같은 진단 분야에 응용하여 적용한다면 획기적인 피폭선량 감소 효과뿐만 아니라 빠른 진단과 함께 신속한 치료가 필요한 환자들에게 매우 중요한 검사방법이 될 것으로 사료된다.

운전중인 변압기의 부분방전 측정기법 적용 (Application of the Partial Discharge Measuring Method in Operating Transformer)

  • 권동진;최인혁;정길조
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.94-98
    • /
    • 2000
  • This paper describes an application of the partial discharge measuring method in operating transformer. In the operating transformer, the useful PD signal may be superimposed by radio intereference voltage and impulse shaped noise signals generated by external corona or power electronics. In this paper, initial investigations after connecting the PD measuring system to the terminals of the measuring impedance showed a very high noise level of 3,700pC due to sinusoidal interferences. In order to reject these noises, this paper applied RIV and band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,700pC to 160pC.

  • PDF

온라인 변압기 부분방전 측정기법 (On Line Partial Discharge Measurement Method for Transformer)

  • 권동진;최인혁;송일근;박재준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.38-42
    • /
    • 2001
  • This paper describes an application of the on line partial discharge measurement method in operating transformer. In the operating transformer, the partial discharge signal may be superimposed by radio intereference voltage(RIV) and pulse shaped noise signals generated by external corona. The partial discharge quantity showed about 3,800pC due to very high sinusoidal interferences at the measuring impedance terminal of the transformer bushing tap. In order to reject these noises, this paper applied RIV filter, band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,800pC to 160pC.

  • PDF

Feasibility of Free-Breathing, Non-ECG-Gated, Black-Blood Cine Magnetic Resonance Images With Multitasking in Measuring Left Ventricular Function Indices

  • Pengfei Peng;Xun Yue;Lu Tang;Xi Wu;Qiao Deng;Tao Wu;Lei Cai;Qi Liu;Jian Xu;Xiaoqi Huang;Yucheng Chen;Kaiyue Diao;Jiayu Sun
    • Korean Journal of Radiology
    • /
    • 제24권12호
    • /
    • pp.1221-1231
    • /
    • 2023
  • Objective: To clinically validate the feasibility and accuracy of cine images acquired through the multitasking method, with no electrocardiogram gating and free-breathing, in measuring left ventricular (LV) function indices by comparing them with those acquired through the balanced steady-state free precession (bSSFP) method, with multiple breath-holds and electrocardiogram gating. Materials and Methods: Forty-three healthy volunteers (female:male, 30:13; mean age, 23.1 ± 2.3 years) and 36 patients requiring an assessment of LV function for various clinical indications (female:male, 22:14; 57.8 ± 11.3 years) were enrolled in this prospective study. Each participant underwent cardiac magnetic resonance imaging (MRI) using the multiple breath-hold bSSFP method and free-breathing multitasking method. LV function parameters were measured for both MRI methods. Image quality was assessed through subjective image quality scores (1 to 5) and calculation of the contrast-to-noise ratio (CNR) between the myocardium and blood pool. Differences between the two MRI methods were analyzed using the Bland-Altman plot, paired t-test, or Wilcoxon signed-rank test, as appropriate. Results: LV ejection fraction (LVEF) was not significantly different between the two MRI methods (P = 0.222 in healthy volunteers and P = 0.343 in patients). LV end-diastolic mass was slightly overestimated with multitasking in both healthy volunteers (multitasking vs. bSSFP, 60.5 ± 10.7 g vs. 58.0 ± 10.4 g, respectively; P < 0.001) and patients (69.4 ± 18.1 g vs. 66.8 ± 18.0 g, respectively; P = 0.003). Acceptable and comparable image quality was achieved for both MRI methods (multitasking vs. bSSFP, 4.5 ± 0.7 vs. 4.6 ± 0.6, respectively; P = 0.203). The CNR between the myocardium and blood pool showed no significant differences between the two MRI methods (18.89 ± 6.65 vs. 18.19 ± 5.83, respectively; P = 0.480). Conclusion: Multitasking-derived cine images obtained without electrocardiogram gating and breath-holding achieved similar image quality and accurate quantification of LVEF in healthy volunteers and patients.

자동 목표물 인식 시스템을 위한 클러스터 기반 투영기법과 혼합 전문가 구조 (Cluster-based Linear Projection and %ixture of Experts Model for ATR System)

  • 신호철;최재철;이진성;조주현;김성대
    • 대한전자공학회논문지SP
    • /
    • 제40권3호
    • /
    • pp.203-216
    • /
    • 2003
  • In this paper a new feature extraction and target classification method is proposed for the recognition part of FLIR(Forwar Looking Infrared)-image-based ATR system. Proposed feature extraction method is "cluster(=set of classes)-based"version of previous fisherfaces method that is known by its robustness to illumination changes in face recognition. Expecially introduced class clustering and cluster-based projection method maximizes the performance of fisherfaces method. Proposed target image classification method is based on the mixture of experts model which consists of RBF-type experts and MLP-type gating networks. Mixture of experts model is well-suited with ATR system because it should recognizee various targets in complexed feature space by variously mixed conditions. In proposed classification method, one expert takes charge of one cluster and the separated structure with experts reduces the complexity of feature space and achieves more accurate local discrimination between classes. Proposed feature extraction and classification method showed distinguished performances in recognition test with customized. FLIR-vehicle-image database. Expecially robustness to pixelwise sensor noise and un-wanted intensity variations was verified by simulation.

관상동맥 전산화단층촬영 조영검사에서 생리식염수 투여를 통한 임상 유용성 평가 (The Clinical Usefulness Evaluation of Normal Saline Injection in Coronary Artery Computed Tomography Angiography(Coronary CTA))

  • 정강교;이미화;조평곤
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권4호
    • /
    • pp.307-313
    • /
    • 2014
  • 본 연구는 bolus tracking method을 이용한 관상동맥전산화단층조영검사(coronary artery CT angiography, 이하 coronary CTA)에서 조영제 주입 전 생리식염수(normal saline) 투여를 통해 변화되는 심박동수(heart rate) 특성을 고려한 촬영방법 변환으로 영상의 질과 선량에 미치는 관계를 보고자 하였다. 연구대상자는 건강검진을 목적으로 건강검진센터에 내원하여 coronary CTA을 시행한 200명의 사람을 대상으로 평가하였다. 그 결과 선량평가에서는 전향적 동조화가 후향적 동조화보다 유효선량이 $6.0{\pm}1.0mSv$(54.1%) 감소되었다. 평균 심박동수는 심장혈관확장제 니트로글리세린(nitroglycerin, 이하 NTG) 섭취 후 변화된 평균 심박동수와 생리식염수 투여 후 변화된 평균 심박동수 비교에서 $4.8{\pm}0.3bpm$의 유의한 차이의 감소를 보였고 심박동수 변화의 폭(heart rate area)에서는 평균 $4.7{\pm}2.0bpm$의 감소를 보였다. 영상평가에서는 SNR과 CNR, 그리고 blurring 정도의 평가에서 모두 심박동수가 감소됨에 따라 유의한 차이를 보였다. 임상에서 coronary CTA에서 피폭선량 감소와 영상의 질 향상을 위해 조영제 주입 전에 생리식염수 투여를 통한 심박동수 특성관찰이 요구된다.