• Title/Summary/Keyword: Noise Power Spectrum

Search Result 448, Processing Time 0.024 seconds

The Improvement in Signal Integrity of FT-ICR MS (FT-ICR 질량분석기의 신호 충실성 향상)

  • Kim, Seung-Yong;Kim, Seok-Yoon;Kim, Hyun Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.201-204
    • /
    • 2011
  • For efficient noise reduction in a Fourier transform ion cyclotron resonance (FT-ICR) mass spectrum, a new algorithm was proposed. The suggested algorithm reduces white and electrical noise, and it improves signal-to-noise ratio. This algorithm has been optimized to reduce the noise more efficiently using the traces of signal level. The algorithm has been efficiently combined with derivative window to improve the resolution as well S/N. Time domain data was corrected for DC voltage interference. $t^n$ window was applied in time domain data to improved the resolution. However, $t^n$ window can improve the signal resolution, it will also increase the noise level in frequency domain. Therefore, newly developed noise reduction algorithm will be applied to make a balance between resolving power and S/N ratio for magnitude mode. The trace algorithm can determine the current data point with several data points (mean, past data, calculated past data). In the current calculations, we assumed data points with S/N ratio more than 3 were considered as signal data points. After the windowing and noise reduction, both resolution and signal-to-noise ratio were improved. This algorithm is applicable more efficiently to frequency dependent noise and large size data.

GPS Output Signal Processing considering both Correlated/White Measurement Noise for Optimal Navigation Filtering

  • Kim, Do-Myung;Suk, Jinyoung
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.13 no.4
    • /
    • pp.499-506
    • /
    • 2012
  • In this paper, a dynamic modeling for the velocity and position information of a single frequency stand-alone GPS(Global Positioning System) receiver is described. In static condition, the position error dynamic model is identified as a first/second order transfer function, and the velocity error model is identified as a band-limited Gaussian white noise via non-parametric method of a PSD(Power Spectrum Density) estimation in continuous time domain. A Kalman filter is proposed considering both correlated/white measurements noise based on identified GPS error model. The performance of the proposed Kalman filtering method is verified via numerical simulation.

Subtraction of excess noise in a gyroscope employing a high-power erbium-doped fiber source (고출력 Erbium 첨가 광섬유 광원을 사용하는 자이로스코프에서 광원 과잉잡음의 소거)

  • 진영준;박태용;박희갑
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.5
    • /
    • pp.396-400
    • /
    • 1999
  • In the fiber-optic gyroscope employing a high-power erbium-doped fiber source, the source excess noise was subtracted from the gyro output through a single processing to improve the gyroscope sensitivity. As the result, we obtained the reduction of noise by 13.5 dB (electrical) which was measured from the noise floor spectrum when the gyro was modulated with the depth of 1.8 rad. In addition, the random walk coefficient of the gyro output was reduced by a factor of 4~5.

  • PDF

Application of Bispectral Analysis to Estimate Nonlinear Acoustic Parameter (음향 비선형 파라미터의 추정을 위한 바이스펙트럼 해석법의 적용)

  • Kim, K.C.;Jhang, K.Y.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.2
    • /
    • pp.85-92
    • /
    • 1999
  • The fact that material degradation can be evaluated by measuring nonlinear acoustic effect has been proposed by previous studies. The most conventional method to measure nonlinear acoustic effect is to measure the absolute magnitude of fundamental and $2^{nd}$ order harmonic frequency component in the propagated ultrasonic wave. For this aim, power spectral analysis technique has been used widely. However, the power spectral analysis has fatal disadvantage that the gaussian additive noise superimposed in the wave signal remains in the power spectrum domain. Moreover, the magnitude of $2^{nd}$ order harmonic frequency component generated by nonlinear effect is so small that it may be suppressed by the noise remained in the power spectrum. In order to overcome this problem, this paper proposes an alternative method using bispectrum analysis, which can reduce the effect of addictive gaussian noise and. the nonlinear parameter can be obtained more stably. Simulations showed that the proposed method can obtain the value of nonlinear parameter near to the true value in the case of low SNR signal. Also, in order to confirm the usefulness of our method in actual case, we compared the nonlinear parameter obtained by using both of power spectral and bispectral analysis for several specimen intentionally degraded by fatigue load.

  • PDF

Speech Enhancement Based on Modified IMCRA Using Spectral Minima Tracking with Weighted Subband Selection (서브밴드 가중치를 적용한 스펙트럼 최소값 추적을 이용하는 수정된 IMCRA 기반의 음성 향상 기법)

  • Park, Yun-Sik;Park, Gyu-Seok;Lee, Sang-Min
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.49 no.3
    • /
    • pp.89-97
    • /
    • 2012
  • In this paper, we propose a novel approach to noise power estimation for speech enhancement in noisy environments. The method based on IMCRA (improved minima controlled recursive averaging) which is widely used in speech enhancement utilizes a rough VAD (voice activity detection) algorithm which excludes speech components during speech periods in order to improves the performance of the noise power estimation by reducing the speech distortion caused by the conventional algorithm based on the minimum power spectrum derived from the noisy speech. However, since the VAD algorithm is not sufficient to distinguish speech from noise at non-stationary noise and low SNRs (signal-to-noise ratios), the speech distortion resulted from the minimum tracking during speech periods still remained. In the proposed method, minimum power estimate obtained by IMCRA is modified by SMT (spectral minima tracking) to reduce the speech distortion derived from the bias of the estimated minimum power. In addition, in order to effectively estimate minimum power by considering the distribution characteristic of the speech and noise spectrum, the presented method combines the minimum estimates provided by IMCRA and SMT depending on the weighting factor based on the subband. Performance of the proposed algorithm is evaluated by subjective and objective quality tests under various environments and better results compared with the conventional method are obtained.

Fan Noise Prediction Method of Air Conditioning and Cooling System (공기조화 및 냉각시스템의 팬 소음예측 기법)

  • Lee, Jin-Young;Lee, Chan;Kil, Hyun-Gwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1318-1320
    • /
    • 2007
  • Fan noise prediction method is presented for air conditioning and/or cooling system applications where fan acts as an internal equipment having very complicated flow interaction with other various system components. The internal flow paths and distribution in the fan-applied systems such as computer or air conditioner are analyzed by using the FNM(Flow Network Modeling) with the flow resistances for flow elements of the system. Based on the fan operation point predicted from the FNM analysis results, the present fan noise model predicts overall sound power, pressure levels and spectrum. The predictions of the flow distribution, the fan operation and the noise level in electronic system by the present method are well agreed with 3-D CFD and actual noise test results.

  • PDF

Characterization of Erbium-Doped Fiber Amplifier (에르븀 첨가 광섬유증폭기의 특성측정)

  • 한정희;이재승;주무정;심창섭
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.5
    • /
    • pp.45-51
    • /
    • 1993
  • An erbium doped fiber amplifier(EDFA) pumped by aingle 1.48$\mu$m LD was fabricated, and its gain and noise characteristics were measured. As a signal source, 1548 nm wavelength DFB LD was used. The small signal net gain of the EDFA module was 21.8 dB with maximum gain coefficient 0.7dB/mW for the erbium fiber length of 17.6 m, the pump power of 58 mW, and an input signal power of -25 dBm, respectively. The saturation power of the EDFA was 1 dBm for the input signal power of -5 dBm and the noise figure, measured by using an optical spectrum analyzer, was 5.8 dB for the input signal power of -40 dBm.

  • PDF

Binary Nonlinear Joint Transform Correlator with Sinusoidal Iterative Filter in Spectrum Domain

  • Jeong, Man-Ho
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.357-362
    • /
    • 2010
  • The joint transform correlator (JTC) has been the best known technique for pattern recognition and identification. This paper proposes a new technique of fringe adjustment by adopting a sinusoidal amplitude-modulated iterative filter convolved with an interference fringe pattern in the joint power spectrum (JPS) domain. The comparison of our new technique and other techniques is presented to show that the newly proposed technique can successfully improve both the correlation peaks and the peak signal-to-noise ratio (PSNR). Simulated results of enhanced interference fringes are also presented.

Investigation of Radiation Effects on the Signal and Noise Characteristics in Digital Radiography (디지털 래디오그라피의 신호 및 잡음 특성에 대한 방사선 영향에 관한 연구)

  • Kim, Ho-Kyung;Cho, Min-Kook;Graeve, Thorsten
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.756-767
    • /
    • 2007
  • For the combination of phosphor screens having various thicknesses and a photodiode array manufactured by complementary metal-oxide-semiconductor (CMOS) process, we report the observation of image-quality degradation under the irradiation of 45-kVp spectrum x rays. The image quality was assessed in terms of dark pixel signal, dynamic range, modulation-transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). For the accumulation of the absorbed dose, the radiation-induced increase both in dark signal and noise resulted in the gradual reduction in dynamic range. While the MTF was only slightly affected by the total ionizing dose, the noise power in the case of $Min-R^{TM}$ screen, which is the thinnest one among the considered screens in this study, became larger as the total dose was increased. This is caused by incomplete correction of the dark current fixed-pattern noise. In addition, the increase tendency in NPS was independent of the spatial frequency. For the cascaded model analysis, the additional noise source is from direct absorption of x-ray photons. The change in NPS with respect to the total dose degrades the DQE. However, with carefully updated and applied correction, we can overcome the detrimental effects of increased dark current on NPS and DQE. This study gives an initial motivation that the periodic monitoring of the image-quality degradation is an important issue for the long-term and healthy use of digital x-ray imaging detectors.

A Study on the Scatter X-ray Signal and Noise Characteristics of Indirect Conversion-Type Detector for Radiography (산란선이 간접변환방식 엑스선 검출기의 신호 및 노이즈 특성에 미치는 영향에 관한 연구)

  • Kim, Junwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.345-353
    • /
    • 2021
  • Digital radiography imaging systems can also help diagnose lesions in patients, but if x-rays that enter the human body cause scatter x-ray due to interaction with substances, they affect the signal and noise characteristics of digital x-ray images. To regard the human body as polymethyl methacrylate (PMMA) and observe the properties of scattered x-ray generated from PMMA on x-ray images, we analyze signal and noise in the spatial domain as well as noise-power spectrum (NPS), and detective quantum efficiency (DQE) at zero frequency. As PMMA thickness increased, signals decreased, the noise increased, and NPS degradation was identified in overall spatial frequencies. Based on these characteristics, zero-frequency performance was also shown to be degraded. Comparative analysis with Monte-carlo simulations will need to be made to analyze the zero-frequency performance by scattered x-ray of indirect conversion-type x-ray detectors more quantitatively.