• Title/Summary/Keyword: Noise Level

Search Result 3,732, Processing Time 0.033 seconds

A Study on Curving noise control by absorption treatment in Urban Rail Transit System (흡음에 의한 도시철도 곡선부 소음저감에 관한 연구)

  • 이재원;손진희;장서일
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.603-608
    • /
    • 2002
  • Sound absorbing materials are applied to the exposed surfaces of curved subway tunnel for the reduction of curving noise level. Before the treatment, acoustical engineering simulation is performed to predict the noise level reduction for different kinds and amounts of absorbing material. The principle of geometrical acoustics is utilized to Peform the simulation efficiently and accurately. The noise levels of the inside and outside of running car body are measured to find the noise level reduction. The average noise level reduction of 8 ㏈ has been attained. It has been shown that the simulated results are comparable to the measured ones.

  • PDF

Characteristics of Noise Exposure Level on Workers of Tunnel Construction Sites (일부 터널건설현장 근로자의 소음노출 수준에 대한 고찰)

  • Kim, Kab Bae;Jang, Jae-Kil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.739-744
    • /
    • 2013
  • The aim of this study is to evaluate the noise level from the machines used for tunnel construction and to analyze the noise exposure level of workers engaged in tunneling works. The sound level meter and noise dosimeters was used for the monitoring of noise in the tunneling work sites. The average noise from jumbo drill was 113.0 dE(A), the noise from pay loader was 92.4 dB(A), the noise from backhoe was 99.9 dB(A) and the noise from shotcrete machine was 94.3 dE(A). The tunneling workers were exposed to 66.9~94.9 dB(A) of noise and other workers exposed to less than 90 dB(A) of noise. Jumbo drill operators were exposed to to 82.5~84.2 dB(A) of noise, backhoe operators were exposed to 70.2~94.9 dB(A) of noise, shotcrete machine operators were exposed to 68.2~74.7 dB(A) of noise and pay loader operators were exposed to 59.2~81.3 dE(A) of noise.

  • PDF

A Study on the Noise Near the Butane-can Explosion Location (부탄 캔 폭발장소 주변의 소음에 관한 연구)

  • 임사환
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.11
    • /
    • pp.1166-1175
    • /
    • 2004
  • People in the advanced society have deep interest in such environmental problems as noise, air quality, water pollution, etc. This paper submits the result of the research on the noise In the surroundings of the butane can explosion location. First, the noise level measured in a residential area, 245 meters' away from the butane can explosion location, was 59.3 dB. Also, the noise level measured in the IGUP (International Graduate University of Peace), 300 meters' away from the explosion site, was 52.5 dB. Second, the above noise levels are lower than the level specified In the Environmental Standard (65 dB), which represented that the experiment was safe. Third, the noise level in a place away from the butane can explosion location varied in accordance with the direction of the wind. Consequently, the noise in all locations (the places where damage to people is expected) surrounding the experimental butane can explosion location was measured to identify the effect of the wind irection.

Comparison between Indoor Noise Level and Subjective Response for Transportation Noise - Focusing on the Aircraft, Road traffic and Railway Noise (교통소음으로 인한 실내소음레벨과 주관반응 분석 - 항공기, 도로교통 및 철도소음을 중심으로)

  • Park, Hyeon-Ku;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.5 s.122
    • /
    • pp.437-447
    • /
    • 2007
  • A series of research to seek for the relationship between subjective responses and noise level for transportation noise have been proceeded, and their results showed similar for some cases and different for some other cases as well, which is considered due to the various conditions such as the way of survey, different scale applied, and country etc. This study aimed to analyze the relationship between sound level and subjective response for the different kinds of transportation noise. The noises recorded in real situation were played to thirty subjects with fourty nine adjectives. The percentage of people annoyed(% PA) and the percentage of people highly annoyed(% HA) were calculated from the subjective results and compared how many percent of people are annoyed and highly annoyed for the same sound level. As a result of calculating the average, the aircraft noise was highest and the white noise lowest. The relationship between window TL and average point was well correlated except the aircraft noise which was scattered because of high sound level at specific frequency and low TL at corresponding frequency. This means that appropriate rating method for airborne sound transmission should be sought for to evaluate outdoor noise which has different frequency characteristics. The Boltzmann equation for % PA and % HA was applied to predict the sound level corresponding to the percentage. It is concluded that the aircraft noise and road traffic noise have almost same response and the railway noise was same with white noise, used for the reference noise, annoyed lower than other noises about by 3 dB.

Ship Radiated Noise Measurement Methods and Accuracy Analysis (선박 방사소음의 측정방법 및 정확도 해석)

  • Lee, Phil-Ho;Yoon, Jong-Rak
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.6 s.99
    • /
    • pp.738-748
    • /
    • 2005
  • The ship radiated noise level fluctuates by the difference of interference and reverberation according to measurement methods and environmental conditions. These phenomena cause error of the source level estimation even in the same environment conditions. This paper describes a quantitative analysis and a reduction method for an error value to the source level estimation in spatial and temporal interference environment. The design criteria of the radiated noise measurement array composed of omni-directional hydrophones and the source level accuracy in the deep water range are given. The source level accuracy in the shallow water range is also derived based on the statistical model of the multiple reflection paths. The results are verified using the water tank experiment and the sea trial.

Railway Noise Exposure-response Model based on Predicted Noise Level and Survey Results (예측소음도와 설문결과를 이용한 철도소음 노출-반응 모델)

  • Son, Jin-Hee;Lee, Kun;Chang, Seo-Il
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.5
    • /
    • pp.400-407
    • /
    • 2011
  • The suggested method of previous Son's study dichotomized subjective response data to modeling noise exposure-response. The method used maximum liklihood estimation instead of least square estimation and the noise exposure-response curve of the study was logistic regression analysis result. The method was originated to modeling community response rate such as %HA or %A. It can be useful when the subjective response was investigated based on predicted noise level. It is difficult to measure the single source emitting noise such as railway because various traffic noise sources combined in our life. The suggested method was adopted to model in this study and railway noise-exposure response curves were modeled because the noise level of this area was predicted data. The data of this study was used by previous Ko's paper but he dealt the area as combined noise area and divided the data by dominant noise source. But this study used all data of this area because the annoyance response to railway noise was higher than other noise according to the result of correlation analysis. The trend of the %HA and %A prediction model to train noise of this study is almost same as the model based on measured noise of previous Lim's study although the investigated areas and methods were different.

A Study on the Road Traffic Noise in Residential Area (주거지역 도로교통경음에 관한 조사연구)

  • 김종오
    • Journal of Environmental Health Sciences
    • /
    • v.8 no.1
    • /
    • pp.13-23
    • /
    • 1982
  • This Study was designed to investigate Traffic condition, Traffic Noise level, Traffic Noise Index (TNI) and Response for dissatisfactions of residents as part of assesment of Noise by 12 Sites in Seoul from July 1st to the end of August 1981. As the resut of this Study, the following Conclusion were obtained 1. The mean traffic Volume of Seoul was 3076/hour ranging 1440/hour to 5772/hour. 2. The range of Road Traffic Noise Level in Residential area was from 73.0dB (A) to 80.2dB (A). The highest level was 80.2dB (A) on Heugseog-dong and the lowest level was 73.0dB (A) on Suyu-dong. 3. Comparision of Road traffic noise level in the day and evening, the range of traffic noise level in day was from 73.9dB (A) to 80.2dB (A), and evening was ranging 73.0 to 79.9dB (A). 4. The range of TNI in Residential area was from 77.5 to 100.0. The highest TNI was 100.0 on Suyu-dong including Heugseog-dong, the lowest TNI was 77.5 on Hyuikyung-dong. 5. Respose of Noise by 360 householders has been examined in Residential Area: Sourse of Noise Causing bothersome to residents was 52.5% of traffic, the types of road traffic Cousing annoyance to residents residents were 84.8% of passing cars and 81.1% of horns, and 71.7% of reading interfered and 68.1% appeal dissatisfactions due to the sleeping disturbance by road traffic noise.

  • PDF

Analysis of Acoustic Noise Characteristics of Jindo-Cheju HVDC (진도-제주 HVDC 변환설비 소음특성 분석)

  • Kim, Jae-Han;Kim, Chan-Ki;Lee, Seong-Doo;Kim, Jin-Young
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.574-576
    • /
    • 2010
  • HVDC converter station consists of a number of noise sources such as converter transformer, ac filter, cooling system and so on. In this paper, we analyzed the simulation results of the outdoor acoustic noise characteristics for HVDC converter station. It shows that maximum noise level in boundary of HVDC converter station exceeds regulation value. The main factors in generating maximum noise level are ac filter and converter transformer. Then we applied some soundproof countermeasure in HVDC converter station. Shielding wall is enough to reduce transformer noise level but not enough to reduce ac filter noise level. In case of ac filter, soundproof building is effective in satisfying noise level regulation in boundary of HVDC converter station. In addition, we also studied effects of season, soundproof woods, ground.

  • PDF

Prediction of the Noise Level inside Metro Electric Cars (통근형 전동차의 객실 내 소음수준예측)

  • 서승일;최문길;김국현
    • Proceedings of the KSR Conference
    • /
    • 1999.05a
    • /
    • pp.185-191
    • /
    • 1999
  • This paper deals with a method to predict the noise level inside metro electric cars running a single-line tunnel at the speed of 80km per hour using ray tracing method, a kind of ray acoustics generally used for a high-frequency and air-born noise analysis. The interior of the car including a under-frame, seats, side doors, end doors, door-pockets, side panels, end panel, a roof panel and so on is modeled. And in order to describe the noise power coming inside, artificial noise sources are designated using sound transmission loss data of each section measured from simple tests and external noise level. The noise level inside the car is calculated and its properties are investigated. The results satisfy the criteria on noise level inside the car.

  • PDF

Analysis of the internal noise level according to the speed for the Korean High Speed Train (한국형 고속전철 개발열차의 차량별 속도에 따른 실내 소음 특성 분석)

  • Park Chun-Soo;Kim Ki-Hwan;Seo Sung-Il;Lee Tae-Hyung;Park Chan-Kyung
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.381-386
    • /
    • 2004
  • In order to develop a high speed train, various conditions have been considered. Internal noise level of cabins is an important one. In this study, The specification of the interior noise level for KHST(Korean High Speed Train) has been adopted the same level of KTX-spec. In this paper, the interior noise levels of KHST are measured and analysed through the speed and other conditions. According to the speed, the level of internal noise(driver's room(PC2), motorized trailer(TM1) and trailer car(TT2)) is compared. The results of measuring data show that the interior noise levels of KHST are good. And noise levels of this paper are useful in the decision of noise specification.

  • PDF