Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings

  • Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.280-285
    • /
    • 2014
  • In order to evaluate the insulation deterioration in the stator windings of five gas turbine generators(137 MVA, 13.8 kV) which has been operated for more than 13 years, diagnostic test and AC dielectric breakdown test were performed at phases A, B and C. These tests included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B and C) of No. 1 generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable and bad level to the insulation condition. Overall analysis of the results suggested that the generator stator windings were indicated serious insulation deterioration and patterns of the PD in all three phases were analyzed to be internal, slot and spark discharges. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. The breakdown voltage at phases A, B and C of No. 1 generator stator windings failed at 28.0 kV, 17.9 kV, and 21.3 kV, respectively. The breakdown voltage was lower than that expected for good-quality windings (28.6 kV) in a 13.8kV class generator. In the AC dielectric breakdown and diagnostic tests, there was a strong correlation between the breakdown voltage and the voltage at which charging current increases abruptly ($P_{i1}$, $P_{i2}$).

마우스 말초혈액 망상적혈구를 이용한 Mitomycin C의 소핵생성효과 (The micronucleus formation in peripheral blood of mitomycin C-treated mice using supravital staining with acridine orange)

  • 허문영;류재천
    • 한국환경성돌연변이발암원학회지
    • /
    • 제16권1호
    • /
    • pp.24-29
    • /
    • 1996
  • In this study, the micronucleus test with peripheral blood using acridine orange coated slides was evaluated in mice treated with mitomycin C(MMC) at doses of 0.5, 1.0 and 1.5 mg/kg body weight. The peripheral bloods were obtained at 0, 24, 48 and 72h after treatment. The frequencies of micronucleated reficulocytes(MNRET) in the MMC-treated groups increased dose-dependently, and showed a peak time at 48h after treatment. We also performed the sex differences of MNRET frequency in 0.5 mg/kg MMC treated group, and we observed no sex differences in this experiment. And we evaluated the usefulness of a direct acting clastogen, N-methyl-N-nitrosourea and a indirect acting clastogen, benzo(a) pyrene as the positive control in this supravital micronucleus test. They also caused a significant increase in MNRET frequencies. These results suggest that the supravital staining micronucleus test using MNRET can be useful tool to evalulate the quantitative and qualitative assessment of genotoxicity in vivo compared to classical in vivo micronucleus test using bone-marrow cells.

  • PDF

리팜피신 제제의 생물학적 동등성시험(제2보) (Bioequivalence Test of Rifampicin Preparations(II))

  • 장일효;범진필;최준식
    • Journal of Pharmaceutical Investigation
    • /
    • 제24권2호
    • /
    • pp.49-55
    • /
    • 1994
  • Bioequivalence test of commercially available rifampicin capsules was performed. Sixteen volunteers were divided into 2 groups and the reference and test drug were given orally (450 mg) by cross-over design. Statistical evaluation of AUC, $C_{max}\;and\;T_{max}$ involved an analysis of variance (ANOVA). The differences of mean value in AUC, $C_{max}\;and\;T_{max}$ between the reference and test drug were within 20% with reference drug. ANOVA showed no significant differences for ‘between group’, ‘drug’ and ‘period’, but not for ‘between subjects’. The power of test $(1-{\beta})\;of\;AUC\;and\;$C_{max}$ was larger than 0.8 and the confidence of bioavailability was $within\;{\pm}20%$. From these results, it was concluded that the two preparations were bioequivalent for AUC and $C_{max}$, but was not for $T_{max}$.

  • PDF

섬유혼입공법을 적용한 고강도콘크리트 기둥의 재하 내화시험 (Fire Test of Fiber Cocktail Reinforced High Strength Concrete Columns with Loading)

  • 염광수;전현규;김흥열
    • 콘크리트학회논문집
    • /
    • 제21권4호
    • /
    • pp.473-480
    • /
    • 2009
  • 폴리프로필렌섬유와 강섬유를 혼입한 고강도콘크리트 기둥의 재하하중비에 따른 내화성능을 검증하기 위하 여 3기의 동일한 기둥시험체를 제작하여 각 시험체에 40%, 50%, 그리고 61%의 설계하중에 해당하는 고정압축하중을 재하한 후 ISO-834 표준내화곡선에 따라 180분간 내화시험을 실시하였다. 폭렬은 발생하지 않았으며, 표면부의 색은 분 홍색을 띤 회색으로 변했다. 시험체의 최대 연직방향 처짐은 1.5~2.2 mm로, 내화시험 중 화재로 인한 시험체의 강도손 실이 발생하지 않았으며, 설계하중의 61%이내에서 시험체의 내화성능은 영향을 받지 않았다. 깊이별 내부 콘크리트의 온도분포, 콘크리트 내부 수분 증발로 인한 온도상승이 변한 점 등 전반적으로 비재하 내화시험 결과와 매우 유사하였다. 180분 내화시험 후의 최종온도는 모서리철근이 491.4oC, 중앙철근이 329.0oC이며, 철근의 총 평균온도는 409.8oC이다. 전 반적인 온도분포의 경향은 비재하 내화시험과 매우 유사하였다. 모서리철근의 열에너지 유입량이 많기 때문에 중앙철 근과의 온도차(153.7oC)가 나타났으며, 가열 후 30~50분 사이에 온도상승추세가 변하였다. 이는 강섬유와 폴리프로필렌 섬유를 혼입한 콘크리트의 온도구배가 낮고, 철근으로의 수분이동과 내부 수분의 막힘현상, 그리고 수분의 기화열 때문이다.

Feasibility of utilizing oven-drying test to estimate the durability performance of concrete

  • Chen, How-Ji;Tang, Chao-Wei;Peng, Hsien-Sheng
    • Computers and Concrete
    • /
    • 제8권4호
    • /
    • pp.389-399
    • /
    • 2011
  • The increasing concern for reinforced concrete structure durability has been justifying in many ways in the last few decades. However, there is no perfect durability test method till now. In this research an alternative method, which is based on the cumulative moisture loss percent of the concrete specimens after oven-drying, was proposed to estimate the durability performance of the concrete. Two temperatures were considered for the oven-drying tests: $100^{\circ}C$ and $200^{\circ}C$. Test results showed that oven-drying at $200^{\circ}C$ was obviously an unsuitable procedure to preserve the fragile microstructure of cement-based materials. By contrast, experimental results through oven-drying at $100^{\circ}C$ allowed estimating the moisture loss percent of cement-based materials in a more rational manner. Moreover, the magnitudes of the cumulative moisture loss percent obtained from oven-drying tests at $100^{\circ}C$ for 48 hours have good correlations with the data of other well-known methods, namely, electrical resistance test, water permeability test, and mercury intrusion porosimetry test. This investigation established that regarding the oven-drying test as one of the tests for evaluating the potential durability of concrete is considerably practicable.

Ceriodaphnia dubia의 먹이섭생 기작과 온도조절에 근거한 급성독성조사법의 비교 (Comparison of Short-Term Toxicity Tests Based on Feeding Behavior and Temperature Control by Ceriodaphnia dubia)

  • 박종호;이상일;조영옥
    • 한국물환경학회지
    • /
    • 제20권1호
    • /
    • pp.48-54
    • /
    • 2004
  • Two methods, a Ceriodaphnia algal uptake suppression test (CAUST) and a new toxicity test based on temperature control (TTBTC) which are based on feeding behaviour and temperature control, respectively, were developed and compared for the adoption as the better methodology for short-term toxicity screening. As previously published by Lee et aI., (1997), the CAUST method is based on the feeding behaviour of C. dubia and requires as little as 1 hour of contact time between C. dubia neonates and toxicant. However, even though CAUST requires only 1 hour of contact time, this method still take many hours for the preparation and measurement. Before the test starts, neonate digestive tracts were cleared by feeding yeast to the daphnids, Neonates were then exposed to toxicant, followed by addition of Scenedesmus subspiatus into the bioassay vessels. Daphnids were examined under the bright-field microscope with the presence of algae (indicated by a green colored digestive tract) or the absence of algae. Uptake indicated no toxic effect, whereas, absence of uptake indicated toxic inhibition. Unlike CAUST, the newly developed method (TTBTC) is based on just temperature control for the toxicity test of C. dubia. Initially, neonates are exposed to toxicants while the temperature of water bath containing media increased to $35.5^{\circ}C$. After 1.25 hour of contact time, the number of the daphnids, either live (no toxic effect) or dead (toxic effect), is counted without the aid of any instrument. In both methods, median effective concentrations ($EC_{50}$ values) were computed based on the results over a range of dosed toxicant concentrations. It showed that TTBTC was as sensitive as the standard 48-hour acute bioassay and CAUST. TTBTC and CAUST were much more sensitive than the I-hour I.Q. test and 30-minute Microtox. This study indicates that TTBTC is an easier and more rapid toxicity test than the standard 48-hour acute bioassay and even CAUST.

토끼의 대동맥 및 폐동맥 판막 동종이식편의 냉장 및 냉동 보존후 생육성 평가(I) (Viability Assay after $4^{\circ}C$ Cold Preservation & Cryopreservation of Aortic & Pulmonic Allograft Valves in Rabbits)

  • 홍종면
    • Journal of Chest Surgery
    • /
    • 제28권8호
    • /
    • pp.731-741
    • /
    • 1995
  • Cardiac valve allografts have been used as replacements for diseased valves and right ventricular outflow tract reconstruction, the long term follow-up of which has been reported satisfactory. For a good long-term result, it is essential that the allograft be viable at implantation. In this study, we aimed at preparing the cardiac valve allografts aseptically, preserving them at cold- and cryo-conditions, and testing the viability of the allografts after preservation by four methods. We tested the viability of the cardiac valve allografts preserved in cold refrigerated state[4$^{\circ}$C in nutrient media & in liquid nitrogen tank[cryopreservation under -149$^{\circ}$C for pre-planned time periods. The testing methods were 1 glucose utility test 2 tissue culture 3 thymidine uptake test and 4 histologic evidence by light microscopy. We observed no differences in the viability between cold- & cryo-groups and similar results among the methods for testing the viability. In conclusion, there was no difference in the viability between cold- and cryopreserved-allografts at least for 14 days of preservation. And glucose utility test and thymidine uptake test were satisfactory in the evaluation of the allograft viability, since they were easy and rapid with relatively quantitative results.

  • PDF

Post-earthquake capacity evaluation of R/C buildings based on pseudo-dynamic tests

  • Kang, Dae-Eon;Yi, Waon-Ho
    • Structural Engineering and Mechanics
    • /
    • 제24권1호
    • /
    • pp.91-105
    • /
    • 2006
  • In this paper, post-earthquake capacity evaluation method of reinforced concrete buildings was studied. Substructure pseudo-dynamic test and static loading test of first story column in a four-story R/C building was carried out in order to investigate the validity of the evaluation method proposed in the Damage Assessment Guideline (JBDPA 2001). In pseudo-dynamic test, different levels of damage were induced in the specimens by pre-loading, and input levels of seismic motion, at which the specimens reached to the ultimate stage, were examined. From the experimental result, no significant difference in damage levels such as residual crack width between the specimens under static and pseudo-dynamic loading was found. It is shown that the seismic capacity reduction factors ${\eta}$ can provide a reasonable estimation of post-earthquake seismic capacity of R/C buildings suffered earthquakes.