• Title/Summary/Keyword: No-plane

Search Result 1,045, Processing Time 0.031 seconds

An experimental study on the load transfer machanism of shallow 2-arch tunnel excavation sequence with vertical discontinuity planes in sandy ground (연직 불연속면이 존재하는 얕은 심도의 사질토 지반에서 2-arch 터널 단계별 굴착에 따른 하중전이에 관한 실험적연구)

  • Oh, Bum-Jin;Lee, Sang-Duk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.3
    • /
    • pp.215-231
    • /
    • 2011
  • In this study, the behavior of a shallow 2-arch tunnel during the excavation in the sandy ground containing vertical discontinuity plane was experimentally studied. Load transfer mechanism in the pillar caused by a 2-arch tunnel excavation was observed. The position of the vertical discontinuity plane was varied. Model tests were carried out in the normal construction sequence of 2-arch tunnel. Test results-showed that the load transfer caused by the 2-arch tunnel excavation was concentrated in the discontinuity plane, and was cut by the discontinuity plane, so no load transfer took place above the discontinuity plane. It was also shown that the effect of adjacent tunnel excavation on the pillar load and the ground deformation was greater when excavating the upper half-face of the main tunnel, more than when excavating the lower half-face.

Changes in longitudinal craniofacial growth in subjects with normal occlusions using the Ricketts analysis

  • Bae, Eun-Ju;Kwon, Hye-Jin;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.44 no.2
    • /
    • pp.77-87
    • /
    • 2014
  • Objectives: This study was designed to define the Korean norm values for the Ricketts analysis. Methods: In this longitudinal study, lateral cephalograms of 31 subjects with normal occlusion were taken biennially from ages 9-19 years. Cephalometric measurements were performed. Parameters for which the 10-year change did not exceed one standard deviation were defined as unchanged. The means and standard deviations for the measured parameters were determined for each age group. Results: No significant changes in growth were observed in the molar relationship, incisor overjet, incisor overbite, mandibular incisor extrusion, interincisor angle, lower incisor tip (B1) to A point-Pogonion (A-PO) plane, upper incisor tip (A1) to A-PO plane, B1 inclination to A-PO, A1 inclination to A-PO, B1 inclination to Frankfurt plane (FH), convexity, lower facial height, facial axis, maxillary depth, maxillary height, palatal plane to FH, cranial deflection, ramus Xi position, or porion location. Continual changes over the 10 years of growth were observed in the maxillary first molar distal position to pterygoid true vertical plane, facial depth, mandibular plane to FH, anterior cranial length, mandibular arc, and corpus length. Conclusions: Clinicians can apply the Korean norms at age 9 as determined in this study when using the Ricketts analysis. The patient's age at the beginning of treatment and their sex should be taken into consideration when drawing visual treatment objectives.

Emission and Structural Properties of Titanium Oxide Nanoparticles-coated a-plane (11-20) GaN by Spin Coating Method

  • Kim, Ji-Hoon;Son, Ji-Su;Baik, Kwang-Hyeon;Park, Jung-Ho;Hwang, Sung-Min
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.146-146
    • /
    • 2011
  • The blue light emitting diode (LED) structure based on non-polar a-plane (11-20) GaN which was coated TiO2 nanoparticles using spin coating method was grown on r-plane (1-102) sapphire substrates to improve light extraction efficiency. We report on the emission and structural properties with temperature dependence of photoluminescence (PL) and x-ray rocking curves (XRC). From PL results at 13 K of undoped GaN samples, basal plane stacking fault (BSF) and near band edge (NBE) emission peak were observed at 3.434 eV and 3.484 eV, respectively. We also found the temperature-induced band-gap shrinkage, which was fitted well with empirical Varshini's equation. The PL intensity of TiO2 nanoparticles ?coated multiple quantum well (MQW) sample is decayed slower than that of no coating sample with increasing temperature. The anisotrophic strain and azimuth angle dependence in the films were shown from XRC results. The full width at half maximum (FWHM) along the GaN [11-20] and [1-100] directions were 564.9 arcsec and 490.8 arcsec, respectively. A small deviation of FWHM values at in-plane direction is attributed to uniform in-plane strain.

  • PDF

Some explicit solutions to plane equilibrium problem for no-tension bodies

  • Lucchesi, Massimiliano;Zani, Nicola
    • Structural Engineering and Mechanics
    • /
    • v.16 no.3
    • /
    • pp.295-316
    • /
    • 2003
  • A method is presented to integrate explicitly certain equilibrium problems for no-tension bodies, in absence of body forces and under the assumption that two of the principal stresses are everywhere null. The method is exemplified in the case of rectangular panels, clamped at their bottoms and loaded at their tops.

Magnetic Circular Dichroism Study of co Thin Films on Pd(111) Surface

  • Kim, Wookje;Kim, Wondong;Kim, Hyunjo;Kim, Jae-Young;Hoon Kho;Park, J.H.;Oh, S.J.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.169-169
    • /
    • 1999
  • We studied magnetic properties of co thin films deposited on Pd (111) surface, which attracted much attention recently due to the perpendicular magnetic anisotropy, using magnetic circular dichroism(MCD). Special attention was paid on the effect of Pd capping and interface roughness on the direction of magnetic easy axis, and for that purpose MCD signals for all Co thicknesses were measured with two different ways : in-plane and out-of-plane geometry. In case of bare Co films deposited on smooth Pd(111) surface, no MCD signal was observed under 4$\AA$ co thickness. At 4$\AA$ Co thickness, MCD signal at the out-of-plane geometry was observed, and for thicker Co films, only in-plane MCD signal was measured. This type of magnetic easy axis transition has been reported for other cases like Co/Pt system. The effect of 5$\AA$ Pd capping on these bare Co films made an remarkable change on the transition of magnetic easy axis. Out-of-plane MCD signals exists up to 20$\AA$ Co thickness, and disappears at 24$\AA$ Co thickness. In-plane MCD signals first appears at 10$\AA$ Co thickness and gradually increases up to 24$\AA$ Co thickness. Between 10$\AA$ and 20$\AA$ Co thickness, in-plane and out-of-plane MCD signal coexist. The formation of multi-domain structure or the existence of tilted magnetic easy axis is an possible scenario for such an interesting coexistence. The effect of interface roughness was also tested by measuring MCD signal on Co films deposited on un-annealed Pd(111) surface. Out-of-plane MCD signal was observed up to 8$\AA$ Co thickness and the anisotropy of MCD signal at 4$\AA$ Co thickness was very large with respect to that of Co film deposited on the smooth substrate. Above 8$\AA$ thickness, there exists only in-plane MCD signal. From above results, it was concluded that both Pd capping and interface roughness induce and reenforce the perpendicular magnetic anisotropy. The large perpendicular magnetic anisotropy of Co/Pd multilayer system made by sputtering method can be well understood from our results.

  • PDF

A Study of Prosthetic Prescriptions sent to the Laboratories for Removable Partial Denture Framework (국부의치 제작을 위한 보철의뢰 서식의 기록에 관한 임상적 연구)

  • Chang, Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.18 no.1
    • /
    • pp.7-13
    • /
    • 1980
  • The purpose of this study was to evaluate the removable partial denture prescriptions including surveyed crowns and design of component parts sent to the laboratory technician. A total of 351 casess with prescription forms and master cast in maxillary and mandibular semi-edentulous situations collected from dental laboratory by random sampling were selected for this study. The evaluation and study observed here involved the classification of edentulous situations, status of abutment splinting, form of rest seats and guiding plane of surveyed crows, location of maxillary major connectors and tripodig marks on the master casts. Removable partial denture prescriptions contained (1) general request (upper and lower cast framework), (2) types of metal, (3) location of retainer(retention, lingual bracing, rest area, guiding plane surface), (4) location and type of major connector, (5) relief area and amount, (6) and other specific instructions. The following informations based on the classified groups such as Group I was those cases sent with no real prescriptions. They say 'make a partial.' No prescriptions, no thought beforehand, Group II was those cases sent with a minimal prescriptions. They say 'make a partial with clasps on May be some preparations, usually inadequate. Group III was those cases sent with a moderately good prescription. Adequate but could be much better. No tripoding but it tell what clasps go where. Still not good prescriptions. Group IV was good cases, tripoded with adequate prescriptions and a prescription which exactly describes what is expected from the laboratory. The analyzed results were as follows: 1. The normal form of rest seats and guiding plane of surveyed crowns in Class. I and Class. II edentulous situations on the maxillary cast were observed 31.9% and 27.89%, respectively. The abutment teeth and retainer without occlusal rests of Class. I and Class. II were showed 11.58% and 8.86%, respectively. In mandibular cases, the normal form of rest seats and guiding plane of surveyed crowns showed 27.54% and 8.82% in Class. I and Class. II situation. The abutment teeth and retainer without rest seats were showed 15.19%, respectively. 2. The splinted surveyed crowns of Class. I and Class. II maxillary edentulous situations in distal extension cases were showed 34.51% and 28.85%, but 28.52% and 10.29%, respectively. 3. The location and type of maxillary major connector delineated on the master cast were 66 cases (44.89%). 4. The results of 351 cases were classified as Group I 146(41.59%), Group II 115 (32.76%), Group III 57 (16.23%), and Group IV 33 (9.48%). 5. The delineation of abutment tooth for clasping were 176 cases (50.14%) among total of 351 cases. 6. The delineation of height of contour line were showed 45 cases (12.8%) in Group II, 14 cases (3.98%) in Group III and 33 cases (9.40%) in Group IV with total 92 cases (26.21%). 7. In surveying procedure, the delineation of tripoding marks and reference line were showed 17 cases (4.84%).

  • PDF

Dilemma of gonial angle measurement: Panoramic radiograph or lateral cephalogram

  • Radhakrishnan, Pillai Devu;Varma, Nilambur Kovilakam Sapna;Ajith, Vallikat Velath
    • Imaging Science in Dentistry
    • /
    • v.47 no.2
    • /
    • pp.93-97
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the accuracy of panoramic imaging in measuring the right and left gonial angles by comparing the measured angles with the angles determined using a lateral cephalogram of adult patients with class I malocclusion. Materials and Methods: The gonial angles of 50 class I malocclusion patients (25 males and 25 females; mean age: 23 years) were measured using both a lateral cephalogram and a panoramic radiograph. In the lateral cephalograms, the gonial angle was measured at the point of intersection of the ramus plane and the mandibular plane. In the panoramic radiographs, the gonial angle was measured by drawing a line tangent to the lower border of the mandible and another line tangent to the distal border of the ascending ramus and the condyle on both sides. The data obtained from both radiographs were statistically compared. Results: No statistically significant difference was observed between the gonial angle measured using the lateral cephalograms and that determined using the panoramic radiographs. Further, there was no statistically significant difference in the measured gonial angle with respect to gender. The results also showed a statistically insignificant difference in the mean of the right and the left gonial angles measured using the panoramic radiographs. Conclusion: As the gonial angle measurements using panoramic radiographs and lateral cephalograms showed no statistically significant difference, panoramic radiography can be considered in orthodontics for measuring the gonial angle without any interference due to superimposed images.

Effects of Different Shoe Heel Heights on the Kinematic Variables of the Lower Extremities during Walking on Slopes by healthy adult women

  • Yang, Yong-pil
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.14 no.3
    • /
    • pp.21-27
    • /
    • 2019
  • PURPOSE: This study examined the changes in the kinematic variables during walking on a downhill ramp according to the shoe heel height. METHODS: The subjects were 10 adult women with no history of musculoskeletal disorders who agreed to participate in the study. Data were collected using a motion analysis system (VICON) consisting of six infrared cameras. The slope was 120 cm in width, 200 cm in length, and 15 in inclination. To confirm the change in gait parameters (stride length, gait speed) and lower extremity joint angle according to the heel heights of the shoes, flat, 5 cm, and 10 cm heel shoes were prepared and walked alternately. RESULTS: As a result, both the stride length and walking speed showed significant differences according to the heel height between flat and 10 cm (p<.05). In the sagittal plane, there was no significant difference in the hip joint and knee joint, but a significant difference was observed in all events in the ankle joint on all heel heights (p<.05). In particular, the heel strike and mid stance events showed significant differences among all height conditions (p<.05). No significant difference was observed in any of the joint angle changes in the frontal plane (p>.05). CONCLUSION: As the shoe heel height increased, the instability increased and efforts to secure the stability were made, leading to a shortened stride length, walking speed, and angle of the ankle joint.

PID Control of a flexible robot rotating in vertical plane (수직면에서 회전운동을 하는 탄성로봇의 PID 제어)

  • Kang, Junwon;Oh, Chaeyoun;Kim, Kiho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.11
    • /
    • pp.34-41
    • /
    • 1997
  • This paper presents a technique to control a very flexible robot moving in a vertical plane. The flexible robot is modeled as an Euler-Bernoulli beam. Elastic deformation is approximated using the assmed modes method. A comparison function which satisfies all geometric and natural boundary conditions of a cantilever beam with an end mass is used as an assumed mode shape. Lagrange's equation is utilized for the development of a discretized model. A control algorithm is developed using a simple PID cnotrol tech- nique. The proportional, integral and deivative control gains are determined based on the dominant pole placement method and tuned to show no overshoot and no steady state error, and short settling time. The effectiveness of the developed control scheme is showed in the hub angular diaplacement control experiment. Three different end masses are uned in the experiment. The experimental results show that developed control algorithm is very effective showing little overshoot, no steady state error, and less than 2.5 second settl- ing time in case of having an end mass which is equivalent to 45% of the manipulator mass. Also the experimental results show that the residual vibration fo the end point is effectively controlled.

  • PDF

LED Source Optimization for the LED Chip Array of the LED Luminaires (LED 조명기구에서 LED 칩 배치에 따른 광원 최적화)

  • Yoon, Seok-Beom;Chang, Eun-Young
    • Journal of Digital Convergence
    • /
    • v.14 no.4
    • /
    • pp.419-424
    • /
    • 2016
  • In this paper, we studied a light distribution for the LED chips arrangement using an optical design software. The structures of the edge type LED luminaires are reflector plane, LGP(lighting guide plane) and diffuse plane. The reflector plane is on the middle of the overall structure. We had simulation that placing LED chips on the reflector center of the reflector edge by changing the position of LED chips above the reflector center at 1mm, 2mm, and 3mm respectively. In the case, when LED chips are on the center of the reflector, it shows the light distribution of the general diffuse illumination, the semi-direct distribution with 0.56 efficiency and the direct distribution with 0.31 efficiency. And the wedge type LGP shows more efficiency than the flat type. Gradually increasing shape of semi-spherical type by 0.015mm has power of 1.02W, efficiency of 0.25, and maximum luminous intensity of 0.104W/sr, it also and shows the better optical characteristics than the reflector plane that have no patterns. This semi-spherical type shows the better optical characteristics than the reflector plane that have no patterns.