• Title/Summary/Keyword: No-Load Test

Search Result 690, Processing Time 0.024 seconds

Experience for development and capacity certification of safely relief valves (안전방출밸브 개발과 용량인증 사례)

  • Kim, Chil-Seong;No, Hui-Seon;Kim, Gang-Tae;Kim, Ji-Heon;Kim, Jong-Su
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.492-500
    • /
    • 2004
  • The purpose of this study is localization of safety relief valves fur Nuclear Service through technical development with overall design, fabrication, inspection, capacity certification test and functional qualification test of safety relief valves in accordance with KEPIC MN Code(or ASME Sec.III ). The safely relief valve is the important equipment used to protect the pressure vessel, the steam generator and the other pressure facility from overpressure by discharging the operating medium when the pressure of system is reaching the design pressure of the system. But we're depending on technology of the other country up to the present time. Because we don't have our own technologies, we have been spent the great time and money on installing and repairing safety relief valve at nuclear power plant. Therefore we have to achieve the development of safety relief valves for Nuclear Service with our own technologies.

  • PDF

Dynamic Characteristics Analysis of Linear Induction Motor (유도형 리니어모터의 동특성 해석)

  • Jang, S.M.;Chang, K.W.;Lee, S.H.;Jung, S.S.;Park, Y.T.;Kim, B.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.626-628
    • /
    • 2000
  • This paper treats the dynamic analysis and test results of Linear Induction Motor. The dynamic analysis is performed by the d,q axis equivalent-circuit model. Equivalent-circut parameters are obtained with no-load, lock test and field analysis. As a results, simulation results are compared with that of dynamic test.

  • PDF

Comparison of Loss Characteristics of High-Efficiency Induction Motor by Parameter Measurement Test (정수 측정 시험에 의한 고효율 유도 전동기의 손실 특성 비교)

  • Pyon, H.S.;Kim, S.C.;Yang, S.H.;Hahn, S.C.;Joo, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.318-320
    • /
    • 1999
  • Electric motor transforms electric power into mechanical power. It is important to increase efficiency of motor to save energy and to decrease operating cost. In this paper, some parameters and losses of high-efficiency induction motor and standard induction motor are measured by blocked-rotor test and no-load test. Operational parameters of high-efficiency induction motor that are compared with those of standard motor.

  • PDF

Development of a Real-Time Steady State Detector of a Heat Pump System to Develop Fault Detection and Diagnosis System (열펌프의 고장진단시스템 구축을 위한 정상상태 진단기 개발)

  • Kim, Min-Sung;Yoon, Seok-Ho;Kim, Min-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2070-2075
    • /
    • 2008
  • Identification of steady-state is the first step in developing a fault detection and diagnosis (FDD) system. In a complete FDD system, the steady-state detector will be included as a module in a self-learning algorithm which enables the working system's reference model to "tune" itself to its particular installation. In this study, a steady-state detector of a residential air conditioner based on moving windows was designed. Seven representing measurements were selected as key features for steady-state detection. The optimized moving window size and the feature thresholds was suggested through startup transient test and no-fault steady-state test. Performance of the steady-state detector was verified during indoor load change test. From the research, the general methodology to design a moving window steady-state detector was provided for vapor compression applications.

  • PDF

EQUIVALENT CIRCUIT AND CHARACTERSTICS CALCULATION OF LIM BY THE LOCK TEST (구속 시험에 의한 선형 유도 전동기의 등가회로 및 특성계산)

  • Kim, Gyu-Tak;Kang, Gyu-Hong;Choi, Tae-Hee;Lee, Jung-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.6-8
    • /
    • 1993
  • In this paper, we proposed a new method which does not need no load test for the characteristics analysis of linear induction motor. A new equivalent circuit of LIM is chosen and a method of determining its constants from results of the lock test is discussed. The calculated results were satisfactorily agreed with experimental results and conventional method.

  • PDF

EQUIVALENT CIRCUIT AND CHARACTERISTICS CALCULATION OF LIM BY THE LOCK TEST (구속 시험에 의한 선형 유도 전동기의 등가회로 및 특성계산)

  • Kim, Gyu-Tak;Kang, Gyu-Hong;Choi, Tae-Hee;Lee, Jung-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.540-542
    • /
    • 1993
  • In this paper, we proposed a new method which does not need no load test for the characteristics analysis of linear induction motor. A new equivalent circuit of LIM is chosen and a method of determining its constants from results of the lock test is discussed. The calculated results were satisfactorily agreed with experimental results and conventional method.

  • PDF

A Study on the Behavior Characteristics of a New-Type FRP-Concrete Composite Deck (신개념 FRP-콘크리트 합성 바닥판의 거동 특성 고찰)

  • Cho Keunhee;Chin Won Jong;Kim Sung Tae;Cho Jeong-Rae;Kim Byung-Suk
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.746-749
    • /
    • 2004
  • A new-type of FRP-concrete composite bridge deck system is proposed and its behaviors are experimentally studied. The new-typedeck consists of FRP as a permanent form and main tension resisting member and concrete as a compression resisting member. A suitable bonding method such as silica coating is applied to the interface between FRP and concrete to ensure composite behavior. The proposed deck system uses the box-shape FRP member, while a typical FRP-concrete composite deck uses the I-shape FRP member. Theproposed deck system has inherent advantages of a FRP-concrete composite deck like corrosion free and easy construction. The new-type deck shows the equal performances compared to a previous one, and has the advantage of reducing self-weight. In this study, the static tests on 3-span FRP-concrete decks in full scale are carried out, so that load-displacement relation, stress distribution, failure mode and design criteria are analyzed. The test results show that the deflection design criterion (L/800, L: span length) is satisfied at the service load state. No concrete tensile crack occurs in the negative moment region above the main girder, regardless of no tensile reinforcement at upper concrete portion.

  • PDF

An Experiment of Flexural Behavior for the Prestressed Concrete Beams with Partially Bonded External Tendons (외부 부분 부착 PSC 보의 휨거동 실험)

  • Yoo, Sung-Won;Lee, Sang-Jun
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.5
    • /
    • pp.141-147
    • /
    • 2012
  • Recently, the external prestressed concrete structures are increasingly being built. The mechanical behavior of prestressed concrete beams with external tendon is different from that of normal bonded PSC beams in that the increment of tendon stress was derived by whole member behavior. By this reason, the ultimate stress of external tendon is smaller than that of bonded tendon or internal unbonded tendon. The purposes of the present paper are therefore to improve the mechanical behavior of external unbonded tendon by using partially bonded external tendon and to evaluate the flexural behavior of partially bonded external tendon by the flexural member experiment. From the experimental results, before flexural cracking, there was no difference between external unbonded, partially bonded and bonded tendons. However, after cracking, yielding load of reinforcement, ultimate load, and tendon stress were increased in the sequence of external unbonded, partially bonded and bonded tendon members. The equation of ACI-318 and AASHTO 1994 were not matched with test results and had no correlations. So the newly proposed equation will be needed including the consideration of tendon profile, tendon bonded type, and so on. The proposed partially bonded external tendon in this paper will be a effective basis for the evaluation of external tendons in construction and design.

Change of electroencephalograph during 3-dimensional image load (입체 TV 영상(3D) 주시시의 유발전위)

  • Cho, Am
    • Journal of the Ergonomics Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.29-35
    • /
    • 1990
  • To investigate and analyze of the human brain-wave changes during 3-dimenslonal image load were expected to take not only an important basic information of 3-dimensional TV usage but also 3-dimensional image design. In this experiment, to analyze the difference of visual analyze handing system for which we present the 2- dimensional image having no parallex and 3-dimensional image by visual evoked potentials(VEP). 2-dimensional image and 3-dimensional image displayed on the screen through video. In the test, the time interval was one sec for presentation of stimulus considering united time of visual information of right eye and left eye during watching the 3-dimensional image also display time interval was 200 mesc for each stimulus image. Results are as follow, (1) N190 appears faster 16msec-20msec in the point of Fz, Cz, Pz, Oz when loaded 3D4 angle than 2D3 angle. (2) About of the P300, 3D4 angle(Otherwise, Oz point was reverse) and in the case of no equipment of liquid crystal shutter, there appeared PEAK near the P250. (3) There were 5% significant difference when the liquid crystal shutter was equiped and didn't, Therefore, this phenomenon show the possibility that Liquid crystal shutter influences on Visual Evoked Potentials.

  • PDF

A New Approach for Corrective and Preventive Control to Unsolvable Case in Power Networks having DERs

  • Dinh, Hung Nguyen;Nguyen, Minh Y.;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.411-420
    • /
    • 2013
  • Recently, Korean system operating conditions have gradually approached an upper limit. When a contingency occurs, the power system may have no solutions. Different from the cases of bad initial guesses or the solutions are too close to the solvability boundary in which numerical methods can be applied, for unsolvable cases, the only way to restore solvability would be structure modifications. In this paper, a new approach for corrective and preventive control to such cases is proposed in two steps: (i) finding any solution regardless its feasibility; (ii) for the infeasible solution, make it feasible with additional modifications at load buses having Distributed Energy Resources. The test case built based on the peak load profile of 2008 by KEPCO including 1336 buses is analyzed. Since reactive power compensation is optimized to restore solvability, all demands are met, therefore no blackouts happen. The proposed method was integrated in the LP program designed by power21 Corporation.