• 제목/요약/키워드: No-Insulation

검색결과 302건 처리시간 0.026초

Numerical analysis on the critical current evaluation and the correction of no-insulation HTS coil

  • Bonghyun Cho;Jiho Lee
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권1호
    • /
    • pp.16-20
    • /
    • 2023
  • The International Electrotechnical Commission (IEC) 61788-26:2020 provides guidelines for measuring the critical current of Rare-earth barium copper oxide (REBCO) tapes using two methods: linear ramp and step-hold methods. The critical current measurement criterion, 1 or 0.1 μV/cm of electric field from IEC 61788-26 has been normally applied to REBCO coils or magnets. No-insulation (NI) winding technique has many advantages in aspects of electrical and thermal stability and mechanical integrity. However, the leak current from the NI REBCO coil can cause distortion in critical current measurement due to the characteristic resistance which causes the radial current flow paths. In this paper, we simulated the NI REBCO coil by applying both linear ramp and step-hold methods based on a simplified equivalent circuit model. Using the circuit analysis, we analyzed and evaluated both methods. By using the equivalent circuit model, we can evaluate the critical current of the NI REBCO coil, resulting in an estimation error within 0.1%. We also evaluate the accuracy of critical current measurement using both the linear ramp and step-hold methods. The accuracy of the linear ramp method is influenced by the inductive voltage, whereas the accuracy of the step-hold method depends on the duration of the hold-time. An adequate hold time, typically 5 to 10 times the time constant (τ), makes the step-hold method more accurate than the linear ramp method.

공동주택의 단열형태별 선형열관류율 평가 (An Evaluation of the Linear Thermal Transmittance for the Internal Insulation versus the External Insulation in Apartment Housings)

  • 이종성;이도헌;전명훈
    • 토지주택연구
    • /
    • 제5권4호
    • /
    • pp.315-323
    • /
    • 2014
  • 본 연구는 외단열시스템 성능평가의 주요인자인 선형열관류율을 국제규격(ISO)에서 제시하고 있는 평가방법에 의거, 내단열시스템 대비 외단열시스템의 열성능에 대한 우수성을 정량적으로 파악하고, 향후 외단열시스템의 열성능 평가를 위한 기초자료로의 활용을 목적으로 한다. 이를 위해 공동주택의 대표적 열교부위인 3개 부위를 내단열과 외단열 시스템으로 설계하고, 각 부위별 단열형태별로 선형열관류율을 평가하였다. 그 결과, 외벽-발코니 슬라브 부위는 열교차단재 설치가 필수적인 것으로 분석되었으며, 열교차단재를 설치할 경우 외단열시스템이 내단열시스템보다 선형열관류율이 1/2 이상 줄어드는 것으로 나타났다. 측벽-발코니 부위와 같이 슬라브가 외부로 돌출되지 않는 구조에서는 외단열시스템을 적용할 경우, 선형열관류율이 거의 0인 것으로 나타났다. 내단열로 설계된 외벽-경계벽의 경우, 선형열관류율은 0.451W/m 로 내단열로 설계된 외벽-발코니 슬라브 등 열교가 있는 부위와 비슷한 값을 보이며, 외단열로 설치될 경우 이 또한 거의 0인 것으로 나타났다. 향후, 공동주택의 외단열시스템 도입 및 성능평가를 위해서는 국제기준을 적용한 국내 평가기준의 제도화마련이 필요하며, 특히 제도화 마련과정에서 선형열관류율 계산 인자 중의 하나인 벽체길이의 계산방법은 국가차원의 결정이 필요할 것으로 판단된다.

100㎛급 글라스 버블 혼입 시멘트계 초경량 무기 단열재의 단열 및 난연특성 (Thermal Insulation and Flame Retardant Properties of Cement Based Super Light-weight Inorganic Thermal Insulation using 100㎛ Grade Glass Bubble)

  • 손배근;송훈
    • 한국건설순환자원학회논문집
    • /
    • 제9권4호
    • /
    • pp.642-649
    • /
    • 2021
  • 건축물의 에너지 절약기준이 강화되면서 외단열 공법의 적용과 단열재 두께가 증가하고 있다. 유기계 단열재는 시공성, 경제성 등 시공비용 절감 효과와 뛰어난 단열성능을 가지고 있다. 하지만, 유기계 단열재 특성상 열에 매우 취약하므로 화재 발생 시 급격한 화재확산과 유독가스 발생으로 심각한 피해가 발생한다. 무기계 단열재는 기본적으로 불연성능을 가지나 무겁고 유기계 단열재에 비해 단열성능이 떨어진다. 글라스 버블은 소다 라임 보로실리케이트 유리로 밀도가 매우 낮고, 내부가 비어 있는 구형의 입자로 볼베어링 효과로 유동성이 개선된다. 또한, 무기계 단열재에 혼입하여 사용할 경우 밀도와 단열성능이 개선된다. 본 연구는 시멘트계 재료와 글라스 버블을 혼합하여 무기 단열재를 제조하였고 단열, 난연 및 불연성능을 평가하였다. 연구 결과, 글라스 버블의 혼입률이 증가할수록 열린 기공을 형성하고 있으나, 기공 및 셀 벽에 분포됨에 따라 충분한 단열성능을 보인다. 또한, 글라스 버블의 혼입률은 10% 이하로 사용하는 것이 바람직하다.

A Study on Floor Impact Sound Insulation Performance of Cross-Laminated Timber (CLT): Focused on Joint Types, Species and Thicknesses

  • Yeon-Su HA;Hyo-Jin LEE;Sang-Joon LEE;Jin-Ae SHIN;Da-Bin SONG
    • Journal of the Korean Wood Science and Technology
    • /
    • 제51권5호
    • /
    • pp.419-430
    • /
    • 2023
  • In this study, the floor impact sound insulation performance of Korean domestic Cross-Laminated Timber (CLT) slabs was evaluated according to their joint types, species and thicknesses in laboratory experiments. The sound insulation performance of the CLT has not been investigated before, thus, this study was conducted to quantify basic data on floor impact sound insulation performance of CLT slabs. 5-ply and 150 mm thick CLT panels made of 2 species, Larix kaempferi and Pinus densiflora, were used for the study. The CLT panels were assembled by 3 types of inter-panel joints to form floor slabs: spline, butt and half-lap. And the 150 mm thick Larix CLT slabs were stacked to the thicknesses of 300 mm and 450 mm. The heavy-weight floor impact sound insulation performance of the 150 mm CLT slabs were evaluated to be 70 dB for the Larix slabs and 71.6 dB for the Pinus slabs, and the light-weight floor impact sound insulation performance, 78.3 dB and 79.6 dB, respectively. No significant difference in the sound insulation performance was found between the slabs of the 2 species or among the 3 types of joints. The reduction of 1 dB in the heavy-weight floor impact sound and 1.6 dB in the light-weight floor impact sound per 30 mm increase in thickness were confirmed through the experiments. This study can be viewed as the basic research for the evaluation of floor impact sound insulation performance of CLT.

이중버블시트를 이용한 단열보온양생공법의 한중매스콘크리트 현장적용 (Field Application of the Mass Concrete Using Insulation Curing Method with Double Bubble Sheets Subject to Cold Weather)

  • 이동규;김종;김기훈;황인성;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 춘계학술논문 발표대회
    • /
    • pp.1-4
    • /
    • 2007
  • This study investigated the applicability of insulation curing method with double layer bubble sheets to the man concrete subjected to cold weather. Temperature history of the mass concrete indicated that the highest temperature of center section was exhibited at $34^{\circ}C$ while the that of surface section was $25^{\circ}C$. Difference between center and surface was shown to be less $10^{\circ}C$ when the temperature of center section was peak section, and thereby associated temperature cracking index was calculated 1.5, and occurrence probability of temperature cracking was 5%, so there was no temperature cracking caused by internal restraint. No temperature crack was observed by naked eye. It was clear that early frost demage and temperature cracking could be restrained due to reducing temperature difference between inner part and outside in the case double bubble sheets applied to insulation curing method in cold weather. The maturity of mass concrete is higher than outside about $72\sim89^{\circ}$ DD, so it was demonstrated to prevent early frost demage and ensure strength excellently. Insulation curing method with double bubble sheets was more economic than heating curing method.

  • PDF

김치냉장고 내의 유동 및 열전달 특성에 관한 수치해석 (A Numerical Study on the Flow and Heat Transfer Characteristics in a Kimchi Refrigerator)

  • 윤준원
    • 설비공학논문집
    • /
    • 제15권12호
    • /
    • pp.1078-1087
    • /
    • 2003
  • Kimchi refrigerator is a household electric appliance developed with the wholly domestic technology for maturing and keeping kimchi. However, the principle of keeping is not yet revealed obviously. This numerical study has been conducted to investigate the flow and heat transfer characteristics in a kimchi refrigerator. The effects of arrangement variation of a evaporation tube are examined. Also, the heat transfer characteristics through the insulation material are discussed in detail. The flow and temperature field was simulated using the commercial code of CFX-5.3. A natural convection flow is formed through about 5/6 region from the bottom within the keeping space and accordingly, the 90% region of kimchi containers satisfies the temperature requirement with 0$\pm$0.5$^{\circ}C$. The stagnant flow exists in the upper 1/6 region of the keeping space and accordingly, the stratified high temperature distributions appear in the upper region of kimchi containers. The upward shift of the start location of a evaporation tube improves the temperature concentration toward $0^{\circ}C$ but the pitch variation is of no effect. The heat fluxes on the insulation surfaces show two-dimensional distributions with being higher toward the center. Through the variation of insulation thickness, 3.5% saving of insulation material is obtained under the same heat transfer rate.

알루미늄 용탕 운반용 고보온성 Ladle 설계 및 평가 (Design and Evaluation of High Insulation Ladle for Carrying Aluminum Molten Metal)

  • 박진영;최석환;윤필환;김억수
    • 한국주조공학회지
    • /
    • 제30권3호
    • /
    • pp.115-120
    • /
    • 2010
  • Recently, an advanced raw material supplying system in diecasting industry that molten metal produced by the raw material supplier can be directly delivered to the diecasting shops was proposed. It was known to have advantages of reducing melting process cost and improving working environment. However, for its successful mass production, the development of high insulation ladle is inevitable. In this study, the optimal mixing ratio of $SiO_2-Al_2O_3$ was investigated and the high insulation ladle with computer simulation result was built in a prototype and evaluated. The prototype which has refractory wall of $SiO_233%-Al_2O_3$ 35%-CaO 33% showed high insulation sufficient for carrying the Al molten metal for 138 minutes. Gas quantity result and SEM-EDS analysis on the melt poured in the ladle also showed extremely low level of 0.028 cc / 100 g and no penetration of Al molten metal into the refractory wall, satisfying the requirements for mass production.

수분 흡수가 단열재의 열전도계수에 미치는 영향에 관한 연구 (A Study on the Effects of Water Absorption on the Thermal Conductivity of Insulation Materials)

  • 유성연;김태호
    • 설비공학논문집
    • /
    • 제25권3호
    • /
    • pp.119-125
    • /
    • 2013
  • IInsulation material is generally used for preventing heat loss from heat transport fluids, and water absorption severely reduces the insulation property. The purpose of this study is to evaluate the amount of water absorption supplied by the pouring method and spraying method, to investigate the effects of water absorption on the thermal conductivity of an insulation material, and modeling the relation between water absorption and thermal conductivity. E-glass, a kind of glass fiber, and HYPERLITE, mainly composed of pearlite, are selected, to compare hygroscopic and insulation properties. E-glass is found to have much higher water absorptivity, compared to HYPERLITE. The thermal conductivity of the water-absorbed E-glass is increased by more than 150%, compared to that of no absorption, while variation of the thermal conductivity of HYPERLITE with water absorption is insignificant. A three-stage model of water absorption for thermal conductivity is developed, and the modeling results are found to be in good agreement with the experimental data.

의복 안감의 보온성에 관한 실험적 연구 (An Experimental Study on the Thermal Insulation of the Linin Fabrics)

  • 정영옥;최정화
    • 한국의류학회지
    • /
    • 제8권1호
    • /
    • pp.1-11
    • /
    • 1984
  • An attempt was made to determine individual thermal resistances of 2-lining fabrics ad 4-outer fabrics for Korean-styled clothes, and 4-lining fabrics ad 5-outer fabrics for Western-styled clothes at $19^{\circ}C$ and $24^{\circ}C$. The thermal insulation effects for different lining fabrics in Korean and Western-styled clothes were deduced in determining heart rate, rectal temperature, mean skin temperature and microclimates of subjects. The subjects were dressed experimental clothing which were made of lining and outer fabrics in question, and seated in an environmental chamber during the experiment. 1. Thermal resistances of lining fabrics : For Korean-styled clothes. nylon sheer is larger than unzosa. For Western-styled clothes, rayon, acetate, nylon(taffeta) and kalkali in that order. 2. Thermal resistances of lining fabrics combined : with outer fabrics: For Korean-styled clothes. the measured value is larger than the one of simple aggregate value. But in the case of Western-styled clothes, the measured value is smaller than simple aggregate value. 3. The effects of lining on the thermal insulation of the whole clothing: In case when subjects wore unlimited number of underwear, no matter what lining fabrics were used in Korean and Western-styled clothes less thermal insulation effects were indicated. For the case, however, if subjects wore only limited underwear, there are significant differences of thermal insulation between experimental clothings.

  • PDF

IMO Type C LNG 저장 탱크의 단열성능 및 구조적 건전성 평가 (Evaluation of Insulation Performance and Structural Integrity of an IMO Type C LNG Storage Tank)

  • 박희우;박진성;조종래
    • 한국기계가공학회지
    • /
    • 제20권7호
    • /
    • pp.1-7
    • /
    • 2021
  • Restrictions on the emissions of nitrogen oxides, sulfur oxides, carbon dioxide, and particulate matter from marine engines are being tightened. Each of these emissions requires different reduction technologies, which are costly and require many pieces of equipment to meet the requirements. Liquefied natural gas (LNG) fuel has a great advantage in reducing harmful emissions emitted from ships. Therefore, the marine engine application of LNG fuel is significantly increasing in new ship buildings. Accordingly, this study analyzed the internal support structure, insulation type, and fuel supply piping system of a 35 m3 International Maritime Organization C type pressurized storage tank of an LNG-fueled ship. Analysis of the heat transfer characteristics revealed that A304L stainless steel has a lower heat flux than A553 nickel steel, but the effect is not significant. The heat flux of pearlite insulation is much lower than that of vacuum insulation. Moreover, the analysis results of the constraint method of the support ring showed no significant difference. A553 steel containing 9% nickel has a higher strength and lower coefficient of thermal expansion than A304L, making it a suitable material for cryogenic containers.