• 제목/요약/키워드: No-Fire Test

검색결과 193건 처리시간 0.02초

선박용 미분무수 소화설비의 성능평가연구 (A Study on the performance test of Water mist system as a fire extinguish system for Ships)

  • 김성윤;안병호;김동석;김유택
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.155-156
    • /
    • 2006
  • Developed and conducted a performance test of the Water mist system that is satisfied with the requirement of a fire test requiring Class 3 Engine Mock-up exceeding net volume $3,000m^3$ as per IMO's MSC/Circ. 668 Appendix B(Test method for fire testing equivalent water-based fire-extinguishing systems for machinery spaces of category A and cargo pump rooms).Even though fuel atomizing was continued for 15 sec. after stopping of the system according to the test method relating to the atomizing fire type, no fire was reignited. This result shows the excellence of the system. There was no damage to the contents of the system after the test.

  • PDF

PE 이종강관의 소방용 배관 적용성에 관한 실험적 연구 (An Experimental Study on Piping Feasibility of PE Compound Pipe for Fire Protection Service)

  • 박정화;오천영;곽지현;손봉세
    • 한국화재소방학회논문지
    • /
    • 제30권3호
    • /
    • pp.55-61
    • /
    • 2016
  • 본 연구는 현재 사용하고 있는 소방용 배관의 부식으로 인하여 발생하는 수계소화설비의 문제를 해결하기 위하여 개발한 Polyethylene (PE) 이종강관을 수계소화설비배관으로 적용할 수 있는지를 파악하기 위한 실제 화재시험을 수행하였다. 개발된 이종배관에 대한 관련시험기준이 없어 국내외 기술자료 및 시험기준을 비교분석하여 적합한 화재시험기준을 선정하여 PE 이종강관의 성능을 분석하였다. 따라서 본 배관의 성능시험에 채택한 화재시험기준은 합성수지배관과 금속배관의 두 가지의 화재시험기준을 적용하였고 총 6차례의 화재실험을 실시하여 배관성능을 평가하였다. 소방용합성수지배관의 시험기준을 적용한 1, 2차의 화재시험결과 이음쇠와 배관에서 파손이나 변형이 없었으며 5분간 내압시험을 실시한 결과에서도 누수가 없었다. 금속배관시험기준을 적용한 화재실험은 총 4회를 실시하였으며 1, 2차 실험은 습식설비를 모사한 것으로 화재시험결과는 PE 이종강관에서 누설이나 파열이 발생하지 않았으며 또한 PE 재질의 이탈 등 손상이 발생되지 않음을 확인하였다. 단, 건식설비를 모사한 3, 4차의 화재시험결과 소화수가 방출되기 이전에 PE 이종강관에서 파열, 변형 등의 손상이 발생하였다. 따라서 실험결과 습식설비를 모사한 화재시험의 경우 PE 이종강관의 융착성, 변형, 파손 등 배관의 성능에 이상이 없음을 확인하였다.

룸 코너 콘 칼로리미터 시험(ISO 9705)과 비교를 통한 FDS 열분해 모델의 신뢰성 분석 (A Reliability Analysis on FDS Pyrolysis Model through Comparing the Room-Corner (ISO 9705) Test)

  • 양성진;이창덕;오지은;강찬용;김학범;이덕희
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.585-593
    • /
    • 2011
  • Actual fire test under a laboratory and fire simulation by using computer are considered into main methodology in order to estimate and predict fire size of railway train. Even if practical fire size could be obtained from the full-model railway car test such as a large scale cone-calorimeter test, it is not always possible and realistic due to that expensive cost and attendant dangers could in no way be negligible. In this point of view, fire simulation analysis method based on the computational fluid dynamics could be proposed as an alternative and it seems to be also efficient and reasonable. However, simulation results have to be verified and validated in accordance with the proper procedure including comparing analysis with the actual fire test. In this paper, fire load and growth aspect was investigated through the room corner test (ISO 9705) for the mock-up model of the actual railway car. Then, it was compared with the output data derived from the simulation by using Pyrolysis Model of the FDS (Fire Dynamics Simulator, by NIST) for the exact same domain and condition corresponding with pre-performed room-corner test. This preliminary verified and validated fire modeling method could enhance the reliability of output data derived from the fire simulation under the similar domain and condition.

  • PDF

방화용 실런트 성능 평가 방법 연구 (A study for the test method of fire resistance construction sealant)

  • 안명수;정진영;배기선
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.179-182
    • /
    • 2013
  • Many kinds of fire-stop sealants have been used for joint sealing, cable penetration part sealing and fireproof structure finishing etc in building sectors which need water-proofing and fire-stop properties. But, fire-stop sealant itself has no specific industry standards in Korea even though there are so many required properties for the application. So, in this study, for the evaluation, we adopted and applied UL standard 94(UL 94) which is commonly used for the fire retardant testing in inflammable materials like plastics and rubbers in electronics industry. In this study, we demonstrated fire resistance properties of each fire-stop sealants which varied with different formulation, thickness and origins available in Korea. Overall, fire stop sealant had better fire resistance performance than normal construction sealant. And the thicker the material, the better the fire resistance performance was. Because there is no national or industry guideline for fire stop sealant itself, each sealant products showed different level of performances under UL94 desigation. Even certain product had very poor fire proof propeties although it claims it can be used for the application.

  • PDF

무인기관실에 효과적인 자동소화장치개발 관한 연구 (A Study on the Development of Fire Extinguishing System for Machinery Spaces of a Small craft)

  • 이찬재;강대선;김동석;곽지현
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.127-128
    • /
    • 2006
  • A study developing the dry powder fire extinguishing system inside the simulated machinery spaces of small boats was performed. Fire tests were conducted inside the compartments having volumes 2.9, 4.5, $8m^3$ respectively. The openings and fans were established on the walls of the compartments. Diesel oil was used for the test fuel, In addition fire extinguishing nozzles using dry powder were installed downward at ceiling and horizontally at the wall or conner. All fires in the test were extinguished under system activation and there was no reignition.

  • PDF

실대형화재평가장치의 개발 및 안정화에 관한 연구 (The Study of Development and Calibration for the Real Scale Fire Test Facility)

  • 유용호;김흥열;신현준
    • 한국화재소방학회논문지
    • /
    • 제22권1호
    • /
    • pp.37-44
    • /
    • 2008
  • 최근 화재와 관련된 연구가 활발해지면서 축소모형실험 등을 통한 연구가 진행되어 왔다. 그러나 실물화재 실험과의 직접적인 상관관계를 설명하기에는 충분하지 못하기 때문에 실물화재에 대한 관심이 증가되어 왔다. 따라서 본 연구에서는 산소소모율법을 적용한 10 MW급 라지스케일로리미터를 개발하였으며, 헵탄 풀 화재를 이용한 발열량 보정을 수행하였다. 그 결과 신뢰성 높은 보정결과를 얻었으며, 보다 진보적인 실물화재연구에 적용할 수 있음을 확인할 수 있었다.

미분무 시스템이 장착된 화염방지장치의 화재 진화 특성에 관한 연구 (A Study on the Fire Suppression Characteristics of a Flame Arrester with Water Mist System)

  • 김해지;이경로
    • 한국기계가공학회지
    • /
    • 제15권5호
    • /
    • pp.117-124
    • /
    • 2016
  • In this paper, we developed a breather valve with a water mist system for use near an oil storage tank. Our process applied a water mist system to the flame arrester to evaluate the fire suppression characteristics. For the fire suppression evaluation of the water mist system, we evaluated the angle of the nozzle, fire suppression, spray particle size, flashback, fire suppression time, and fire suppression test of antifreeze. Through the fire suppression test, the best fire suppression nozzle used an angle of $140^{\circ}$, and the flashback phenomenon of flame arrester did not occur. The fire suppression time of water mist system time was within three seconds, and the antifreeze was no problem with the fire suppression.

질소와 노벡 혼합가스를 이용한 청정소화약제의 소화성능에 관한 연구 (A Study on Clean Agent Fire Extinguishing Ability Using Nitrogen and Novec Mixtures Gas)

  • 임우섭;정종진;남동군;사공성호;김종원;최근주
    • 한국안전학회지
    • /
    • 제23권6호
    • /
    • pp.76-83
    • /
    • 2008
  • In the course of increasing in human and material damage caused by fire, it is an important research field to develop clean extinguishing agent which does no harm to global environment as well as has a good extinguishing efficiency. This research is a basic step to develop a new clean extinguishing agent. In order to get a satisfactory result, we tested fire extinguishing ability using nitrogen and Novec mixtures gas which are inert gas and new clean extinguishing agent. We used Cup Burner Test made by international standard ISO-14520 regulations of gaseous extinguishing agent ability test, and the fuels used in the test are n-heptane, methanol, ethanol, iso-propanol and 1-butanol. The experimental results of flame extinguishing concentration are n-heptane 6.54%, methanol 8.47%, ethanol 6.98%, isopropanol 6.10% and butanol 6.54% by pure Novec agent. So the finding is that a new clean agent, Novec has an efficient extinguishing ability in a state of gas. Also, in a test as to mixtures gas of nitrogen and Novec, it has a good result for minimum oxygen concentration is under 16%.

소방펌프차의 고압방수를 위한 중계방수방식에 관한 실증적 연구 (An Empirical Study on the Relay Pumping Method for the High Pressure of Fire Engine Pump)

  • 민세홍;권용준;박종덕
    • 한국화재소방학회논문지
    • /
    • 제27권1호
    • /
    • pp.52-59
    • /
    • 2013
  • 본 연구에서는 초고층 건물 화재 등 고압방수가 필요한 상황에서 방수압력을 유지하기 위하여 소방펌프차의 중계방수방법과 활용방안을 정립하고자 시험을 실시하였다. 중계 방수압력의 변화에 대하여 시험결과 소방펌프차의 방수구를 개방하고 측정하였을 경우 방수구를 폐쇄한 상태에서 측정한 결과보다 약 20 %가 감소한 것으로 나타났다. 소방활동 현장에서 보다 더 효율적으로 활용하기 위하여 소방펌프차 2대의 압력을 각각 변화시키면서 시험한 결과에서도 비슷한 효율이 나타나는 것으로 확인되었다. 현재 고압 방수능력이 있는 소방펌프차가 소방서에 배치되어 있지 않고 소방펌프의 형식승인 및 검정기술기준에서도 고압 소방펌프에 대한 규정이 없기 때문에 현재 보유하고 있는 소방차를 활용하여 초고층 화재 등 고압방수의 필요성이 있는 화재현장에 효과적으로 대응하고자 본 연구 결과를 토대로 소방차량 운영 및 활용방안을 제안한다.