• Title/Summary/Keyword: No-Core Cut

Search Result 18, Processing Time 0.025 seconds

MARGINAL FIT RELATED TO MARGIN TYPES OF GLASS INFILTRATED ALUMINA CORE FABRICATED FROM AQUEOUS-BASED ALUMINA TAPE

  • Oh, Nam-Sik;Yu, Byeung-Su;Kim, Il-Kyu;Choi, Jin-Ho;Kim, Dae-Joon;Park, Il-Seok;Lee, Myung-Hyun;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.3
    • /
    • pp.262-268
    • /
    • 2002
  • Statement of problem. In-Ceram system is one of the all-ceramic crowns that can be used in anterior 3 unit fixed partial dentures and posterior single crowns. The alumina core used in In-Ceram system is manufactured using slip-casting technique. The slip-casting technique is difficult and technique sensitive. To improve this problem, tape-casting method was introduced into dentistry. There were no studies to examine the effect of margin design on the margin fitness of all-ceramic crowns fabricated from alumina tape. Purpose. The purpose of this study was to compare the marginal fitness of glass infiltrated alumina core fabricated from aqueous-based alumina tape according to different margin types ($90^{\circ},\;110^{\circ},\;135^{\circ}$ shoulder margin). Material and method. Three upper central resin incisors were prepared with $90^{\circ},\;110^{\circ}$, and $135^{\circ}$ shoulder margins for all-ceramic crowns, respectively. The resin teeth were duplicated and master die and special plaster die were made as usual. After alumina cores were fabricated from aqueous-based alumina tape, cores were cemented to each 15 epoxy dies replicated from three resin teeth with resin cement. These cemented cores were embedded in epoxy resin. Specimens were cut mesiodistally and buccolingually. Marginal gap and discrepancy were measured under microscope. Results. The marginal gap and discrepancy of $90^{\circ}$ marginal angle was $75.1{\mu}m,\;86.6{\mu}m,\;110^{\circ}$ marginal angle was $41.5{\mu}m,\;50.7{\mu}m$ and $135^{\circ}$ marginal angle was $51.7{\mu}m,\;54.2{\mu}m$, respectively. The smallest value was seen in 110 (angle, which was statistically significant compared to that of $90^{\circ}$ angle (p<0.05). Conclusion. Marginal fitness of alumina cores made of alumina tape with $110^{\circ}$ shoulder margin was best and others were clinically acceptable.

Development of High Efficiency Self Diagnosis Type Neon Transformer using Groin Direction of Non-Oriented Silicon Steel Strip (압연 방향을 적용한 자체 진단형 고효율 네온관용 변압기)

  • 변재영;김윤호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.1
    • /
    • pp.17-24
    • /
    • 2003
  • In this paper, a high efficiency leakage transformer for neon tube is developed to improve its power factor, to reduce its core loss and weight by using a technique of shape optimization and grain direction of non-oriented silicon steel strip. A protection circuit is designed for all types of neon transformer loaded with one or more neon tubes. Whenever the neon tube fails to be started up or comes to the life end, or encounters faults with open-circuits at the output terminals of the neon transformer, the electronic type protection circuit will be initiated to avoid more critical hazards. These neon transformers need a electronic type protection circuit to prevent from current stresses on circuit components by neon tube fail. The input of the transformer is automatically cut on when the abnormal condition occurs, preventing waste of no-load power.

Management to Prepare Fast Green Suitable for International Golf Tournament in Korea - A Case Study of the Lakeside Country Club - (한국에서 국제 골프 토너먼트 규격에 맞는 빠른 그린 관리 방법 - 레이크사이드 컨트리 클럽을 사례로 -)

  • 장유비;김진관;박장혁;심경구
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.31 no.1
    • /
    • pp.66-77
    • /
    • 2003
  • The purpose of this study is to propose a standard putting green management program to prepare fast green suitable for international golf tournaments, and to conform whether the reported green speed model can be applied to the real field situations. The west course of Lakeside Country Club was selected for the case study. This study was initiated on August 1st, 2001 and continued through October 4th, 2001. The results are summarized as follows: 1. Following the long-term schedule, 'penncross' creeping bentgrass turf was mowed at 5.0mm(37days), 4.5mm(8days), 4.0mm(4days), 3.5mm(2days), 3.2mm(2days), 3.0mm(2days), 2.8mm(2days) and the mowing direction was changed daily. Variation of mowing height was reduced to a minimum range. Core aerification with deep tines was applied 19 days prior to the first practice round. Dry sand maintenance was top-dressed 2 times at 1.5mm/$m^2$ on the 17th day and 1.0mm/$m^2$ on the 10th day. Minimum irrigation was applied to keep the turf alive. During the tournament preparation week, dew on the putting greens was removed by using a sponge roller. Following the dew removal, the greens were cut once each morning at a height of 2.8mm. The mower used was the 21 inch working behind mower equipped with a tournament bedknife and 11 reel blades. Following the mowing, the peens were rolled with a light-weight roller in one direction in the morning. Rolling was used as a finishing technique to ensure that the surface was as smooth as possible, and to provide true ball roll and maximum green speed. In conclusion these management practices satisfied the daily green stimpmeter readings required for USGA championship play. 2. During the period of tournament preparation, no damage was observed on the green, but scalping in green edge appeared in about 0.39% of the total area of 18 greens in the west course.

The effects of non-thermal plasma and conventional treatments on the bond strength of fiber posts to resin cement

  • do Prado, Maira;da Silva, Eduardo Moreira;Marques, Juliana das Neves;Gonzalez, Caroline Brum;Simao, Renata Antoun
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.2
    • /
    • pp.125-133
    • /
    • 2017
  • Objectives: This study compared the effect of hexamethyldisiloxane (HMDSO) and ammonia ($NH_3$) plasmas on the bond strength of resin cement to fiber posts with conventional treatments. Materials and Methods: Sixty-five fiber posts were divided into 5 groups: Control (no surface treatment); $H_2O_2$ (24% hydrogen peroxide for 1 min); Blasting (blasting with aluminum oxide for 30 sec); $NH_3$ ($NH_3$ plasma treatment for 3 min); HMDSO (HMDSO plasma treatment for 15 min). After the treatments, the Ambar adhesive (FGM Dental Products) was applied to the post surface (n = 10). The fiber post was inserted into a silicon matrix that was filled with the conventional resin cement Allcem Core (FGM). Afterwards, the post/cement specimens were cut into discs and subjected to a push-out bond strength (POBS) test. Additionally, 3 posts in each group were evaluated using scanning electron microscopy. The POBS data were analyzed by one-way analysis of variance and the Tukey's honest significant difference post hoc test (${\alpha}=0.05$). Results: The Blasting and $NH_3$ groups showed the highest POBS values. The HMDSO group showed intermediate POBS values, whereas the Control and $H_2O_2$ groups showed the lowest POBS values. Conclusion: Blasting and $NH_3$ plasma treatments were associated with stronger bonding of the conventional resin cement Allcem to fiber posts, in a procedure in which the Ambar adhesive was used.

The Influence of AH-26 and Zinc Oxide-Eugenol Root Canal Sealer on the Shear Bond Strength of Composite Resin to Dentin (AH-26 및 산화아연유지놀 근관실러가 상아질에 대한 복합레진의 전단결합강도에 미치는 영향)

  • Cho, Ju-Yeon;Jin, Myoung-Uk;Kim, Young-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.3
    • /
    • pp.147-152
    • /
    • 2006
  • The purpose of this study was to evaluate the influence of the AH-26 root canal sealer on the shear bond strength of composite resin to dentin. One hundred and forty four (144) extracted, sound human molars were used. After embedding in a cylindrical mold, the occlusal part of the anatomical crown was cut away and trimmed in order to create a flat dentin surface. The teeth were randomly divided into three groups; the AH-26 sealer was applied to the AH-26 group, and zinc-oxide eugenol (ZOE) paste was applied to the ZOE group. The dentin surface of the control group did not receive any sealer. A mount jig was placed against the surface of the teeth and the One-step dentin bonding agent was applied after acid etching. Charisma composite resin was packed into the mold and light cured. After polymerization, the alignment tube and mold were removed and the specimens were placed in distilled water at $37^{\circ}C$ for twenty four hours. The shear bond strength was measured by an Instron testing machine. The data for each group were subjected to one-way ANOVA and Tukey's studentized rank test so as to make comparisons between the groups. The AH-26 group and the control group showed significantly higher shear bond strength than the ZOE group (p<0.05). There were no significant differences between the AH-26 group and the control one (p>0.05). Under the conditions of this study, the AH-26 root canal sealer did not seem to affect the shear bond strength of the composite resin to dentin while the ZOE sealer did. Therefore, there may be no decrease in bond strength when the composite resin core is built up immediately after a canal filling with AH-26 as a root canal sealer.

THE MEASUREMENT OF THE IONOSPHERIC TOTAL ELECTRON CONTENT USING P-CODE OF GPS (GPS의 P 코드를 이용한 이온층의 총전자수 측정)

  • 서윤경;박필호;박종욱;이동훈
    • Journal of Astronomy and Space Sciences
    • /
    • v.11 no.1
    • /
    • pp.71-80
    • /
    • 1994
  • It is generally known that the measurement of the ionospheric total electron content(TEC) by GPS can more accurately monitor the broader area of the ionosphere than other current methods. \Ve measured the TEC along a slant path considering the arrival time differences of P-code which is transmitted from GPS satellites with the modulation on two L-band carrier frequencies, L1 (1574.42MHz) and L2 (1227.60MHz). Under the assumptions that the ionosphere is uniformly distributed and its average height is 350km, we transformed the slant TEC to the vertical TEC at the point that the line-of-sight direction to GPS satellite cut across the average height of the ionosphere. Because there is no dual frequency P-code GPS receiver in Korea, we used the data observed at the TAIW GPS station ($N25^{\circ},E121.5^{\circ}$) in Taiwan which is one of the core stations in International GPS and Geodynamics Services (IGS). The TEC values obtained in this work showed a typical daily variation of the ionosphere which is high in the daytime and low in the nighttime. Our results are found to be consistent with the SOLAR-DAILY data of NOAA and the Klobuchar's model for the ionospheric correction of GPS. In addition, in the cornparision with SOLAR-DAILY data, we estimated the precision of our TEC measurement as 2 TEC.

  • PDF

Christian Teachers in Tense Situation: Performative Dialogue Stimulating Normative Professionalism (긴장의 시대 속에서 규범적 전문주의를 촉진하는 기독교교사의 수행적 대화에 관한 연구)

  • Avest, K.H. (Ina) ter
    • Journal of Christian Education in Korea
    • /
    • v.61
    • /
    • pp.9-35
    • /
    • 2020
  • In the second half of the previous century the composition of the teacher population - and the composition of the pupil and parent population - in the Netherlands gives rise to the name change 'age of secularisation' to 'age of pluralisation'. In previous centuries the (religious or secular) worldview identity of the parents and the educational philosophy of the school were attuned to each other, and merged into a mono-cultural perspective on the identity development of pupils. The basis for both - the upbringing by the parents and the socialisation in the family on the one hand, and the teachers' efforts to enculturate the students at the school on the other - was a similar life orientation. The school choice of the parents was predetermined by their commitment to a particular (religious) worldview, very often inspired by Christianity. The religious identity of their children developed in a clear-cut context. However, in contemporary society plurality dominates, at home and at the school, both in case of the parents and the teachers. A direct relationship with a community of like-minded believers is no longer decisive for parents with varying cultural and religious backgrounds. Instead, a good feeling upon entering the schoolyard or the school building is a convincing argument in the process of school choice. The professional identity development of teachers and the religious identity development of children takes place in a plural context. Our question is: what does this mean for the normative professionalism of the teacher? To answer this research question we make use of the resources of the Dialogical Self Theory (DST) with its core concepts of 'voice' and 'positioning'. After presenting the Dutch dual education system (with public and denominational schools) we provide a lively description of a Dutch classroom situation occurring in a public school, as viewed from the perspective of the teacher. The focus in this description is on performative dialogue as a 'disruptive moment' and on its potential for the hyphenated religious identity development of teachers, which makes up a part of their normative professionalism.

  • PDF

Head to Head Comparison of the Chun Nomogram, Percentage Free PSA and Primary Circulating Prostate Cells to Predict the Presence of Prostate Cancer at Repeat Biopsy

  • Murray, Nigel P;Reyes, Eduardo;Orellana, Nelson;Fuentealba, Cynthia;Jacob, Omar
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.6
    • /
    • pp.2941-2946
    • /
    • 2016
  • Background: The limitations of total serum PSA values remain problematic, especially after an initial negative prostate biopsy. In this prospective study of Chilean men with a continued suspicion of prostate cancer due to a persistently elevated total serum PSA, abnormal digital rectal examination and initial negative prostate biopsy were compared with the use of the on-line Chun nomagram, detection of primary malignant circulating prostate cells (CPCs) and free percent PSA to predict a positive second prostate biopsy. We hypothesized that men negative for circulating prostate cells have a small risk of clinically significant prostate cancer and thus may be conservatively observed. Men positive for circulating prostate cells should undergo biopsy to confirm prostate cancer. Materials and Methods: Consecutive men with a continued suspicion of prostate cancer underwent 12 core TRUS prostate biopsy; age, total serum PSA and percentage free PSA and Chun nomagram scores were registered. Immediately before biopsy an 8ml blood simple was taken to detect primary mCPCs. Mononuclear cells were obtained by differential gel centrifugation and identified using double immunostaining with anti-PSA and anti-P504S. Biopsies were classifed as cancer/no-cancer, mCPC detecton test as negative/positive and the total number of cells/8ml registered. Areas under the curve (AUC) for percentage free PSA, Chun score and CPCs were calculated and compared. Diagnostic yields were calculated with reference to the number of possible biopsies that could be avoided and the number of clinically significant cancers that would be missed. Results: A total of 164 men underwent a second biopsy; 41 (25%) had cancer; the AUCs were 0.65 for free PSA, 0.76 for the Chun score and 0.87 for CPC detection, the last having a significantly superior prediction value (p=0.01). Using cut off values of free PSA <10%, Chun score >50% and ${\geq}1$ CPC detected, CPC detection had a higher diagnostic yield. Some 4/41 cancers complied with the criteria for active surveillance, free PSA and the Chun score missed a higher number of significant cancers when compared with CPC detection. Conclusions: Primary CPC detection outperformed the use of free PSA and the Chun nomagram in predicting clinically significant prostate cancer at repeat prostate biopsy.