• Title/Summary/Keyword: No improved

Search Result 6,462, Processing Time 0.039 seconds

A Study on the Development of Solar Heat Proof Hat for Summer Field Work (하절기 방서용 농작업모 개발에 관한 연구)

  • Choi Jeong Wha;Jeong Young Ok
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.14 no.4 s.36
    • /
    • pp.281-291
    • /
    • 1990
  • Experiment I and II had done to develop the solar heat proof hat for field work in the summer. In the experiment I physical characteristics of several fabrics was tested to determine which one Is proper to make the solar heat proof hat. On the base of above results in the experiment II three improved solar heat proof hat was deviced and tested solar heat proof effect and compared the existing summer working hat by wearing trials in the environmental chamber. The results obtained were as follows. 1. In the view of the physical characteristics of six fabrics (Blue T/C, White poplin, Vapor transfer silver coating nylon taffeta, No vapor trans(or silver coating nylon taffeta, Aluminum coating T/C, Microporous fabric), the light color T/C and no vapor transfer silver coating nylon ta(feta is proper to make improved solar heat proof working hat. 2. Three improved hats that are made of white T/C, grey T/C and no vapor transfer silver coating nylon taffeta have more solar heat proof effect than the existing summer working hat. 3. Among the three improved hats, the improved hat that is made of no vapor transfer silver coating nylon taffeta is most effective to proof the solar heat.

  • PDF

Design of Improved Detection Instrumentation for the Annulus Gas System for Wolsong 2

  • Kim, Seog-Nam;Koo, Jun-Mo;Chang, Ik-Ho;Jung, Ho-Chang;Han, Sang-Joon
    • Nuclear Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.423-430
    • /
    • 1996
  • The improved and advanced Annulus Gas System(AGS) has been developed for Wolsong 2 to satisfy the requirements of the regulatory body. The Atomic Energy Control Board(AECB) required a shorter detection time following a small leak from a pressure tube and/or calandria tube. This paper describes licensing requirements, functional requirements and detail design description for the AGS. The Wolsong unit No. 1 AGS was designed to operate as a stagnant system normally requiring only pressure regulation and having provisions for purging. no improved AGS involves the adoption of gas recirculation in AGS, duplication of dew point indicators with additional instrumentation and sampling provisions to prompt operator action. The improved system operates in the recirculation mode with continuous dew point measurement for leak detection. An AGS with improved detection instrumentation is provided.

  • PDF

Feasibility study of improved median filtering in PET/MR fusion images with parallel imaging using generalized autocalibrating partially parallel acquisition

  • Chanrok Park;Jae-Young Kim;Chang-Hyeon An;Youngjin Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.222-228
    • /
    • 2023
  • This study aimed to analyze the applicability of the improved median filter in positron emission tomography (PET)/magnetic resonance (MR) fusion images based on parallel imaging using generalized autocalibrating partially parallel acquisition (GRAPPA). In this study, a PET/MR fusion imaging system based on a 3.0T magnetic field and 18F radioisotope were used. An improved median filter that can set a mask of the median value more efficiently than before was modeled and applied to the acquired image. As quantitative evaluation parameters of the noise level, the contrast to noise ratio (CNR) and coefficient of variation (COV) were calculated. Additionally, no-reference-based evaluation parameters were used to analyze the overall image quality. We confirmed that the CNR and COV values of the PET/MR fusion images to which the improved median filter was applied improved by approximately 3.32 and 2.19 times on average, respectively, compared to the noisy image. In addition, the no-reference-based evaluation results showed a similar trend for the noise-level results. In conclusion, we demonstrated that it can be supplemented by using an improved median filter, which suggests the problem of image quality degradation of PET/MR fusion images that shortens scan time using GRAPPA.

Improved Sensitivity of an NO Gas Sensor by Chemical Activation of Electrospun Carbon Fibers

  • Kang, Seok-Chang;Im, Ji-Sun;Lee, Young-Seak
    • Carbon letters
    • /
    • v.12 no.1
    • /
    • pp.21-25
    • /
    • 2011
  • A novel electrode for an NO gas sensor was fabricated from electrospun polyacrylonitrile fibers by thermal treatment to obtain carbon fibers followed by chemical activation to enhance the activity of gas adsorption sites. The activation process improved the porous structure, increasing the specific surface area and allowing for efficient gas adsorption. The gas sensing ability and response time were improved by the increased surface area and micropore fraction. High performance gas sensing was then demonstrated by following a proposed mechanism based on the activation effects. Initially, the pore structure developed by activation significantly increased the amount of adsorbed gas, as shown by the high sensitivity of the gas sensor. Additionally, the increased micropore fraction enabled a rapid sensor response time due to improve the adsorption speed. Overall, the sensitivity for NO gas was improved approximately six-fold, and the response time was reduced by approximately 83% due to the effects of chemical activation.

Performance analysis of improved hybrid median filter applied to X-ray computed tomography images obtained with high-resolution photon-counting CZT detector: A pilot study

  • Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3380-3389
    • /
    • 2022
  • We evaluated the performance of an improved hybrid median filter (IHMF) applied to X-ray computed tomography (CT) images obtained using a high-resolution photon-counting cadmium zinc telluride (CZT) detector. To study how the proposed approach improves the image quality, we measured the noise levels and the overall CT-image quality. We established a CZT imaging system with a detector length of 5.12 cm and thickness of 0.3 cm and acquired phantom images. To evaluate the efficacy of the proposed filter, we first modeled two conventional median filters. Subsequently, we were able to achieve a normalized noise power spectrum result of ~10-8 mm2, and furthermore, the proposed method improved the contrast-to-noise ratio by a factor of ~1.51 and the coefficient of variation by 1.55 relative to the counterpart values of the no-filter image. In addition, the IHMF exhibited the best performance among the three filters considered as regards the peak signal-to-noise ratio and no-reference-based image-quality evaluation parameters. Thus, our results demonstrate that the IHMF approach provides a superior image performance over conventional median filtering methods when applied to actual CZT X-ray CT images.

ACCURACY OF IMPROVED STONE CASTS FROM ELASTOMERIC IMPRESSION MATERIALS (탄성고무인상재에 따른 초경석고 모형의 정밀도에 관한 연구)

  • Kim, Kee-Hong;Chang, Ik-Tae;Yim, Soon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.3
    • /
    • pp.301-312
    • /
    • 1999
  • The purpose of this study was to compare the accuracy of currently used elastomeric impression materials for complete arch impression taking. Five elastomers (Impregum, Permlastic, Express, Extrude, Examix) and one Irreversible hydrocolloid (Aroma-fine) were tested. For each material, 5 impressions were made of stainless steel model to which five tapered posts were attached. Custom trays were used for polyether and polysulfide impression materials, and putty/wash two step technique was used for addition polyvinylsiloxane impression materials. Improved stone mod els were poured to all impressions. Accuracy of the materials was assessed by measuring ten distances on stone dies poured from impressions of the master model. All measurements for master and improved stone models were made with three dimensional measuring machine. The results were as follows 1. The dimensional accuracy of polyether, extrude, and examix were significantly superior to poly-sulfide, exress, and alginate in reproducing full arch mode (p<0.05) 2. There were no statistical differences in dimensional accuracy for full arch impression between polyether extrude and examix (p>0.05). 3. there were no statistical differences in dimensional accuracy between polysulfide, express, and alginate(p>0.05). 4. There were no statistical differences between addition polyvinyl siloxane materials (p>0.05) 5. There were no statistical differences between anterior-posterior and lateral dimensional changes of all impression materials (p>0.05).

  • PDF

Calculation of dynamic stress intensity factors and T-stress using an improved SBFEM

  • Tian, Xinran;Du, Chengbin;Dai, Shangqiu;Chen, Denghong
    • Structural Engineering and Mechanics
    • /
    • v.66 no.5
    • /
    • pp.649-663
    • /
    • 2018
  • The scaled boundary finite element method is extended to evaluate the dynamic stress intensity factors and T-stress with a numerical procedure based on the improved continued-fraction. The improved continued-fraction approach for the dynamic stiffness matrix is introduced to represent the inertial effect at high frequencies, which leads to numerically better conditioned matrices. After separating the singular stress term from other high order terms, the internal displacements can be obtained by numerical integration and no mesh refinement is needed around the crack tip. The condition numbers of coefficient matrix of the improved method are much smaller than that of the original method, which shows that the improved algorithm can obtain well-conditioned coefficient matrices, and the efficiency of the solution process and its stability can be significantly improved. Several numerical examples are presented to demonstrate the increased robustness and efficiency of the proposed method in both homogeneous and bimaterial crack problems.

A Clinical Study of Gagamsipungtang(GGSP) - in view of treatment for fever in children- (가감시평탕(加減柴平湯) 효능(效能)에 대한 임상적(臨床的) 연구(硏究) - 소아(小兒)의 발열(發熱)에 대한 효과(效果)를 위주(爲主)로 -)

  • Chang Gyu-Tae;Kim Jang-Hyun
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.12 no.1
    • /
    • pp.41-53
    • /
    • 1998
  • The purpose of this study was on effect of Gagamsipungtang(GGSP) which removal of fever, side effect etc. During 4months between September and December 1998 , GGSP water extract administered to the patients coming to Dept. of Pediatrics, Dongguk university Pundang Oriental Hospital on account of the symptom of fever with common cold in acute stage, and this study was conducted for 97 children (male 55, female 42). GGSP was used in children both men and women. There were 13 kinds of complications including cough, nasal obstruction, headache, nausea, anorexia, chilling and sweat etc. The distributions of remedial value were improved(62.9%) and no improved(37.6%) patients. 'Improved' standed for no fever over 2 days after GGSP used to patients. GGSP was affected in remedial values by only used without antipyretics. Side effect were diarrhea, anorexia, vomiting and so on.

  • PDF

Improved Model of the Iron Loss for the Permanent Magnet Synchronous Motors

  • Junaid, Ikram;Nasrullah, Khan;Kwon, Byung-Il
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.2
    • /
    • pp.10-17
    • /
    • 2012
  • This paper presents an improved iron loss model, for the computation of the no load iron loss in the stator core of the in-wheel permanent magnet synchronous motors (PMSM), for the cases of with and without stator skew. 2-D analytical model is used for the computation of tooth and yoke flux densities of the in-wheel PMSM. The no load iron loss computed by the improved iron loss model, for the cases of with and without skew is compared with the finite element method (FEM) and the results show good consistency.

The Effect of Oxygenated Crystalloid Cardioplegia for Myocardial Protection (심정지액의 oxygenation이 심근보호에 미치는 영향)

  • 강면식
    • Journal of Chest Surgery
    • /
    • v.25 no.11
    • /
    • pp.1203-1208
    • /
    • 1992
  • Current methods of myocardial protection has been improved with cardioplegia and hypothermia. We compared St. Thomas hospital cardiopleic solution without oxygenation[Group I], with oxygenation[Group II] and with oxygenation with filter[Group III] under isolated working heart model. Heart rate recovery was more significantly improved in Group II than Group I after 15 minutes of recovery time [p<0.05]. Maximal systolic pressure shows no difference as it increases with time. Cardiac ouputs were not diffrent between groups. Recovery time was shorter significantly in group II and group III than group I [p<0.05] Use of filter showed no difference. As a conclusion, oxygenated cardioplegic solutions improves ability to protect the heart against ischemia and it is manifested by improved recovery time and heart rate.

  • PDF