• Title/Summary/Keyword: No clean

Search Result 640, Processing Time 0.026 seconds

Application of Coliform Bacterial Plasmid as a Trophic Indicator (콜리형 세균 Plasmid의 영양단계 지표 활용에 관한 연구)

  • Cho, Hong Bum
    • The Korean Journal of Ecology
    • /
    • v.11 no.1
    • /
    • pp.29-36
    • /
    • 1988
  • This present study has been carried out to examine the correlation between the distribution of the coliform bacterial plasmids and the viability test against heavy metals in the upper stream of Han river(Gapyung; clean water) and the its basin (Anyang Cheon; polluted water). And the distribution of plasmids were examined to be used as trophic indicator for analysis between the clean and polluted waters. 1. A total of 110 isolates were analyzed for the presence of plasmids by means of the boiling method and agarose gel techniques. Plasmids were significantly more frequent in the strains which had been isolated from the clean water (14.3%). Also, there were much higher multiplicity of plasmids at the polluted water(41.0%), compared with the clean water (33.0%). By the comparision between molecular weight of bacterial plasmids in the clean water and those of polluted water, there were no significant differences of the clean water from the polluted water, to such extent as 30.0%, 28.6%, respectively, in frequency for occurrence of high molecular weight plasmids iver 35.8% Mdal. 2. Each isolate was carried out the resistance test for mercury(10-5M), nickel(10-3M) and arsenic (0.1%). At the polluted site, the survival ability of the plasmid-carrying straings(Hg, 31.0%l Ni, 5.7%; As, 65.7%) was higher than that of the non plasmid-carrying strains(Hg, 12.1%; Ni, 3.0%; As, 54.6%). This trend was more remarkable in the clean site (plasmid-carrying strains: 16.7%,-,-). As a result it is suggested that plasmids could be used as an indicator of a certain types of water pollution. In addition, heavy metals might have inflyenced, some extent, to the distribution of plasmids in the environment which has been surveyed in the present study.

  • PDF

Analysis of Gas Emissions and Power Generation for Co-firing Ratios of NG, NH3, and H2 Based on NGCC (NGCC 기반 천연가스, 암모니아, 수소 혼소 발전 비율에 따른 CO2와 NOx 배출량 및 전력 생산량 분석)

  • Inhye Kim;Jeongjae Oh;Taesung Kim;Minsuk Im;Sunghyun Cho
    • Korean Chemical Engineering Research
    • /
    • v.62 no.3
    • /
    • pp.225-232
    • /
    • 2024
  • The reduction of CO2 emissions in the energy production sector, which accounts for 86.8% of total greenhouse gas emissions, is important to achieve carbon-neutrality. At present, 60% of total power generation in South Korea is coal and natural gas. Replacing fossil fuel with renewable energy such as wind and solar has disadvantages of unstable energy supply and high costs. Therefore, this study was conducted through the co-firing of natural gas, ammonia and hydrogen utilizing the natural gas combined cycle process. The results demonstrated reduction in CO2 emissions and 34%~238% of the power production compared to using only natural gas. Case studies on mass fractions of natural gas, ammonia and hydrogen indicated that power production and NOx emissions were inversely proportional to the ammonia ratio and directly proportional to the hydrogen ratio. This study provides guidelines for the use of various fuel mixtures and economic analysis in co-firing power generation.

Development of Clean Water Supplying System for Greenhouse Cultivation and Convenience Water (II) - Assessment of the FDA System through a Site Application - (시설용수 및 영농편의용수 공급시스템 개발 (II) - FDA 시스템 현장적용성 평가 -)

  • Lee, Kwang-Ya;Choi, Kyung-Sook
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.5
    • /
    • pp.101-106
    • /
    • 2009
  • The previous study developed the Filter-Disinfection-Adsorption (FDA) system to provide clean irrigation water for greenhouse cultivation as well as convenience water to farmers. In this study, the field examination was undertaken to assess performance of the FDA system. The field application was made in the suburb of Daegu, one of the large city in Korea. The study area located near by down-stream of Gum-Ho river is suffering low irrigation water quality problems with no water supply service facilities. Four water quality parameters including Suspended Solid (SS), Biological Oxygen Demand (BOD), coliform, and turbidity were selected to test the purification performance of FDA system. Also in order to improve the system, this study investigated the defects of using the FDA system through field monitoring. As results, it was found that this system can be used to supply good quality of irrigation water for greenhouse cultivation and also provide convenience water to farmers in the field areas of no water supply services.

Development of Clean Water Supplying System for Greenhouse Cultivation and Convenience Water (I) - Development of the FDA System - (시설용수 및 영농편의용수 공급시스템 개발 (I) - FDA 시스템 개발 -)

  • Lee, Kwang-Ya;Choi, Kyung-Sook
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.5
    • /
    • pp.95-100
    • /
    • 2009
  • The water purification systems have been hardly used for agricultural purpose due to their complicated compositions and high costs for farmers, while only simple filtrations have been applied to irrigation systems in order to prevent the system from clogging problems. This study therefore developed a clean water supplying system, the Filter-Disinfection-Adsorption (FDA) system, especially for greenhouse cultivation of where low quality of water is available. This system has also been produced for providing convenience water to farmers in the areas of no water supply service systems for the purpose of washing their bodies or agricultural machineries after farm work. The FDA system consists of three stages of purification processes with an integral module, including disk and teflon filtrations and Ultraviolet (UV) sterilization processes. Indoor experiments were undertaken with a trial product of the FDA system to test its performance. The operation test of the process was performed as well as the condition check of each item including UV module, filters, control panel, pump, valves, etc. The results shows good performance of each test with no critical problems. The initial and maintenance costs were also analysed with other purification systems. From the comparisons, the FDA system found to be very economical and easy to use.

A Study on the Pattern for the Clean Room Garment of the Overall Type (오버롤(Overall)형 방진복의 패턴설계에 관한 연구)

  • Na, Mi-Hyang;Jang, Kyung-Jin;Lee, Yeun-Soon
    • Korean Journal of Human Ecology
    • /
    • v.6 no.2
    • /
    • pp.121-131
    • /
    • 1997
  • This study was to design the clean room garment which fits for a body and adjusts well to the action. We examined the body's changes in action through a body measurment and made a sample of the clean room garment to which had adapted the body's changes in action and evaluated the function and the appearance compared with the existing the clean room garment. The followings were summery of the results : 1. Back intersyce breadth decreased, trunk length increased and the other parts were not change. At a posture of raising hands($M_3$) in comparison with an upright posture($M_0$). Back intersyce breadth, hip length and knee length increased and the other parts were a little change. At a bowing posture($M_2$) in comparison with an upright posture($M_0$). Back hip girth, knee length, hip length and leg length increased and the other parts were not change. At a working posture on a chair($M_1$) in comparison with an upright posture($M_0$). 2. The overall clean room garment was made increasing on the changes of part of a body through measuring and body measurement. 3. From the test of the function, it became known that the devised clean room garment was superior to the existing one in the parts of neck, shoulder, armpit and elbow at a working posture on a chair($M_1$), in the parts of neck, shoulder, and armpit at a bowing posture($M_2$), and the armpit at a posture of raising hands($M_3$). The appearance was better on the whole. 4. From the examination of photographs, the waist line of the devised clean room garment was not so much pulled up as that of the existing one on moving. And when sitting down on a chair, the waist line of the existing one was pulled down while that of the devised one had no change. As above, we investigated the actual conditions of wearing the clean room garment and measured the body's changes according the various actions. So we applied these results to the devised clean room garment but we couldn't research the clean mom effect of it owing to not obtaining the measuring instrument. The aspect of ergonomics liked the feeling of wearing and fitted to the action must be given consideration to the clean room garment, and simultaneously the dust-resistant effect must be taken into consideration in order to improve the quality of the goods. Therefore, we think it should be continued the research on the dust-resistant effect, material, washing method, quality control, and size along with the aspect of ergonomics.

  • PDF

Development of a Duct Cleaning Robot and Technology Trends for Subway Stations (지하역사 덕트 청소로봇 기술동향 및 개발)

  • Jeong, Woo-Tae;Park, Duck-Shin
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1335-1341
    • /
    • 2011
  • Conserving clean air and removing contaminants and particular matters accumulated in the ventilation system of the subway stations are key issue for green railway environment. There is no national guideline or industrial regulations to sustain clean duct and ventilation system, which requires rapid reformation of cleaning procedure and system. In fact, accumulated various particular matters and dusts can occur secondary air contamination and become a primary health harm factor for subway passengers. This study investigates various duct cleaning technologies and trends. In additon, effective cleaning method with an automated robot device is proposed. In particular, current dust cleaning technologies and duct cleaning robots are analyzed based on their functions and feasibilities. The proposed design of automated device is expected to save the operating cost of subway HVAC system and sustain clean air environment.

  • PDF

A Study on Experiment of CNG as a Clean Fuel for Automobiles in Korea

  • Chauhan, Bhupendra Singh;Cho, Haeng-Muk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.5
    • /
    • pp.469-474
    • /
    • 2010
  • Gasoline engines have proven their utility in light, medium and heavy duty vehicles. Concern about long term availability of petroleum and the environment norms by the increased vehicular emission have mandated the search for safe fuel. CNG is an environmentally clean alternative to the existing spark ignition engines with the advantages of minimum change. A higher octane number and a higher self ignition temperature make it an attractive gaseous fuel. The thermal efficiency is better than gasoline for the same engine. The reduced carbon mono oxide, carbon di-oxide, hydrocarbon emissions is a favorable outcome along with a slight increase in $NO_x$ emission when compared with gasoline fuel to a dual fuel mode in the existing spark ignition engines. The result from the experiment shows that CNG could be a potential substitute fuel that maintains performance and emissions characteristics in gasoline engines.

NO and $SO_2$ Removal by Dielectric Barrier Discharge-Photocatalysts Hybrid Process (유전체 장벽 방전-광촉매 복합공정에 의한 NO와 $SO_2$ 제거)

  • Kim, Dong-Joo;Nasonova, Anna;Kim, Kyo-Seon
    • Clean Technology
    • /
    • v.13 no.2
    • /
    • pp.115-121
    • /
    • 2007
  • In this study, we analyzed experimently the NO and $SO_2$ removal by the dielectric barrier discharge-photocatalysts hybrid process. The glass spheres were used as a dielectric material for dielectric barrier discharge and the $TiO_2$ photocatalysts were coated onto those spheres by the dip-coating method. The $TiO_2$ particles were coated in the sponge-shape, which has the larger surface area. As the voltage applied to the plasma reactor, the pulse frequency of applied voltage, or the residence time increases, the NO and $SO_2$ removal efficiencies increase. The increase in the supplied concentrations of NO and $SO_2$ leads to the higher energy for NO and $SO_2$ removal and the NO and $SO_2$ removal efficiencies decrease. These experimental results can be used as a basis to design the dielectric barrier discharge-photocatalysts hybrid process to remove NO and $SO_2$.

  • PDF

Optimized Normalization for Unsupervised Learning-based Image Denoising (비지도 학습 기반 영상 노이즈 제거 기술을 위한 정규화 기법의 최적화)

  • Lee, Kanggeun;Jeong, Won-Ki
    • Journal of the Korea Computer Graphics Society
    • /
    • v.27 no.5
    • /
    • pp.45-54
    • /
    • 2021
  • Recently, deep learning-based denoising approaches have been actively studied. In particular, with the advances of blind denoising techniques, it become possible to train a deep learning-based denoising model only with noisy images in an image domain where it is impossible to obtain a clean image. We no longer require pairs of a clean image and a noisy image to obtain a restored clean image from the observation. However, it is difficult to recover the target using a deep learning-based denoising model trained by only noisy images if the distribution of the noisy image is far from the distribution of the clean image. To address this limitation, unpaired image denoising approaches have recently been studied that can learn the denoising model from unpaired data of the noisy image and the clean image. ISCL showed comparable performance close to that of supervised learning-based models based on pairs of clean and noisy images. In this study, we propose suitable normalization techniques for each purpose of architectures (e.g., generator, discriminator, and extractor) of ISCL. We demonstrate that the proposed method outperforms state-of-the-art unpaired image denoising approaches including ISCL.

A Study on the Comparison of Emission Factor Method and CEMS (Continuous Emission Monitoring System) (배출계수법과 연속자동측정법에 의한 배출량 비교 연구)

  • Jang, Kee-Won;Lee, Ju-Hyoung;Jung, Sung-Woon;Kang, Kyoung-Hee;Hong, Ji-Hyung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.5
    • /
    • pp.410-419
    • /
    • 2009
  • Generally, air pollutant emission at workplace is estimated by two methods: indirect methods using emission factors and direct methods based on CEMS (Continuous Emission Monitoring System). CAPSS (Clean Air Policy Support System) is a representative indirect method and the national air pollutant database of Korea. However, characteristics of some workplaces may create a gap between CAPSS and CEMS data. For improving of emission data accuracy, emission data of CEMS (named CleanSYS) equipped at 138 target workplaces were compared with those of CAPSS. As a result, $SO_x$ and $PM_{10}$ emission levels obtained by CAPSS were lower than those of CleanSYS. $SO_x$ and $PM_{10}$emission ratios were 61.5% and 71.2% lower respectively, showing the biggest gaps. On the other hand, $NO_x$ emission of CAPSS was higher by 10.4%. $SO_x$ showed the biggest difference in 'Energy industry combustion' and $NO_x$ did in 'Production Process' within the SCC category. $PM_{10}$ presented a large gap in 'Manufacturing industry combustion.' The differences in $SO_x$ between the two systems occurred because some large-size facilities lack pollution controllers or efficient pollution controllers. Based on this study, CAPSS emission database of Korea will improve accuracy through adopting CEMS emission system, which enables more efficient national atmospheric policies and workplace management.