• 제목/요약/키워드: No Failure Test Time

검색결과 100건 처리시간 0.032초

저장조건(貯藏條件)이 들깨유(油) 및 참깨유(油)의 산패도(酸敗度)에 미치는 영향(影響) (Effects of Storage Conditions on Rancidity of Perilla and Sesame Seed Oils)

  • 김혜경;이양자;이기열
    • Journal of Nutrition and Health
    • /
    • 제12권1호
    • /
    • pp.51-58
    • /
    • 1979
  • It is a general trend everywhere that the uses of vegetable oils are increasing due to the fact that they are effective in curing and preventing symptoms of high blood pressure and various heart failure conditions. At the same time the concept that oxidative rancidity is caused by the oxidation of unsaturated fatty acid moieties whose subsequent decomposition gives rise to various undesirable, sometimes toxic compounds is now well accepted. Linolenic acid (C, 18:3) is one of highly unsaturated and readily oxidizable fatty acid. The content of this essential polyunsaturated fatty acid in perilla seed oil (PSO) was found to be as high as 48% while only 1.5% in sesame seed oil (SSO). In this experiment the oxidative stability of PSO was compared with that of SSO. The experimental test group were as follows: A) Stored at different temperatures, namely $4^{\circ}C,\;30^{\circ}C,$ and $60^{\circ}C,$ B) Stored at room temperature $(20{\pm}5^{\circ}C)$ ; a. protected from sunlight and air, b. exposed to air without sunlight c. exposed to sunlight but protected front air, d. completely exposed to both air and sunlight. The following results were obtained; 1) It was found to be most stable against oxidation to store both PSO and SSO under the low temperature $(4^{\circ}C)$ condition. According to P.V. measurements it was found to be safe to keep both oils up to $30^{\circ}C$ for at least 8 weeks. When exposed to air, sunlight and high temperature $(60^{\circ}C)$, P.V. of PSO reached there peak values, which were much higher than those of SSO. This explains much of its instability as compared to SSO against oxidation. 2) The effect of high temperature $(60^{\circ}C)$ on A.V. was found to be more striking than those of all the other storage conditions. The condition of refrigeration was most effective in keeping A.V. low for both oils as was the case in P.V. 3) For both oils, I.V. decreased throughout the experimental period (8 weeks). The range of decrement was larger for PSO than SSO. 4) There was no significant change in the compositions of fatty acids of SSO caused by various experimental storage conditions. But for PSO the compositions of stearic, oleic and linoleic acid were decreased, whereas linolenic acid was increased proportionally.

  • PDF

음향방출법에 의한 용사코팅 피막부식재의 파손 해석 (Failure Analysis of Corroded Coating Materials by Acoustic Emission)

  • 김귀식;현창해;홍용의;손창환
    • 한국해양공학회지
    • /
    • 제19권5호
    • /
    • pp.43-49
    • /
    • 2005
  • This paper is to investigate the effect of corrosion by acoustic emission method in tensile loading and the adhesiveness between substrate and coating layer. The powders used are Zn and Amdry625, respectively. They are coated on brass alloy substrate. AE signals of Zn and Amdry625 coating layer increase drastically in strain $2\%$. However, those of Zn specimen have more than those of Amdry625 specimen. When the specimens executed the corrosion test under $3.5\%$ NaCl solution for 500, 1000 hours, the salt solution penetrated into the surface of the substrate through the pores of the coating layer. As a result, corrosion production formed on the surface of the substrate. The adhesiveness between coating layers is weakened by the polarization and corrosion itself. The AE event, count, and energy of corroded coating specimens decrease, compared to specimens without corrosion. The results are summarized as follows : 1. In the tensile tests, the time that it took to start and develop the cracks and exfoliations between the surface of the substrates and the plasma spray coatings were different according to the type of plasma sprayed material, which are Zn and Amdry625. These phenomena were obvious at the strain rate 1 to $5\%$, and few available data were found after that stage. 2. The specimens with Zn coating showed the characteristics of crack, according to the changes of the tensile strength applied on the substrates while those with Amdry625 showed exfoliation as a result of low adaptation to the tensile strength. 3. The anti-corrosion specimens showed that the adhesive properties between the substrate and the plasma spray coating were strong in the order of Zn, Amdry. It showed that Corroded specimens cracked or exfoliated easily, even with the small energy, because those had a comparatively weakened adhesive property, due to corrosion. 4. Zn specimen showed no corrosion phenomena on the surface of the substrates, because they had the function of sacrifice anode however, Amdry625 specimen showed the corrosion, because it did not have that function.

폐결핵 환자의 수술전 항결핵제 투여기간에 따른 수술후 임상경과 (Postoperative Clinical Courses According to the Length of Preoperative Drug Therapy in Pulmonary Tuberculosis)

  • 권은수;김대연;박승규
    • Tuberculosis and Respiratory Diseases
    • /
    • 제47권6호
    • /
    • pp.775-785
    • /
    • 1999
  • 연구배경: 내성결핵의 발현으로 인하여 수술요법이 활성화되면서 폐결핵에서 절제술에 대한 표준화된 적응증과 언제 수술을 시행할 것인가 하는 문제가 대두되게 되었다. 그러나, 수술의 이상적 시기는 보고자에 따라 다양하다. 이에 본 연구는 폐결핵 환자에서 폐절제술전 투약 기간과 술후 결과를 서로 비교 분석하여 폐결핵의 수술의 시기를 결정하는데 지표가 되고자 하였다. 방 법: 국립마산결핵병원에서 1993년 1월부터 1997년 12월까지 입원 치료를 받은 환자 중 폐절제술을 시행 받은 69예를 진료기록을 중심으로 조사하였다. 전체 환자군 69 예를 술전 투약 기간에 따라 1개월, 2개월, 3개월, 4개월, 5개월, 6개월, 7개월, 8개월, 9개월, 10개월, 11개월, 12개월의 간격으로 환자군을 분류하고 각군의 술후 합병증 발생율, 술후 치료실패율, 치료종결후 재발율을 $x^2$-test를 이용하여 서로 비교하였고, 수술 직전 객담 AFB 배양 양성이었던 28예를 술전 투약 기간에 따라 상기와 같이 분류하고 각군의 술후 합병증 발생율, 술후 치료실패율, 치료종결후 재발율을 비교하였다. 결 과: 전체 69예 중 남자가 56예, 여자가 13예 이었고 16세에서 63세의 연령분포를 보였다(중앙값 33 세). 술전 내성 약제수는 평균 3.1제였다. 내성의 분포는 다제 내성결핵이 전체의 54%, 약제 내성결핵이 19%, 모든 약제에 감수성인 경우가 7%, 내성검사를 하지 않은 경우와 그 결과를 알 수 없는 경우가 20% 였다. 결핵 치료의 과거력이 한 번도 없었던 예에서 최다 6회의 치료력을 보였고, 술전, 술후 평균 사용약제수는 각각 4.6제, 4.4제였다. 술전 투약 기간은 0.1개월에서 24.8개월까지 다양하게 나타났고, 술후 투약기간은 2.7개월에서 30.2개월까지 나타났고 평균 13개월의 투약기간이 있었다. 수술날짜를 기준으로 술후 추적관찰기간은 평균 30.8개월이었다. 전체 69예 중 술후 치료실패한 경우가 8예로 치료실패율이 11.6%였다. 추적관찰이 가능하였던 59예 중 4예가 재발되어 재발율은 6.8%였다. 전체 환자군을 술전 투약 기간에 따라 나누어 각각의 분류군 마다 치료실패율, 재발율, 합병증 발생율을 비교하였으나 유의한 차이는 없었다. 수술직전 객담 AFB 배양 양성군과 음성군간에 술후 치료실패율, 재발율, 합병증 발생율 등에 차이가 있을 것으로 기대되어 비교해 보았는데, 재발율과 합병증 발생율은 수술직전 객담 배양 양성군과 음성군간에 통계적으로 유의한 차이는 없었으나, 양성군 28예 중 7예(25.0%, p<0.01)의 술후 치료 실패가 있었고, 음성군에서는 41예 중 1예(2.4%)의 치료실패가 발생하여 치료실패율에서 통계적으로 유의한 차이가 나타났다. 이에 수술직전 객담 AFB 배양 양성군에서 술전 투약 기간에 따라 상기와 같이 각각의 분류군 마다 치료실패율을 통계적으로 비교하였으나 술전 투약 기간에 따른 술후 결과의 유의한 차이는 없었다. 결 론: 상기의 결과를 바탕으로 폐결핵에서 절제술을 시행함에 있어 술전 투약 기간은 술후 치료실패, 재발, 합병증 발생 등의 술후 결과에 크게 영향을 미치지 않는 것으로 보인다. 그러나, 상기 결론을 좀더 명확하게 하기 위하여는 더욱더 많은 연구가 필요하리라 생각된다. 또한 술전 환자의 과거 치료력, 내성 약제수, 수술의 적응, 술후 약제의 조합, 술후 투약기간 등에 관하여 앞으로 활발한 연구가 있어야 하겠다.

  • PDF

급성대동맥해리에 대한 혈압강하요법으로서의 Nicardipine.HCI 주사액(Perdipine$^{circledR}$)의 유효성 및 안전성을 검토하기 위한 다기관 공동, 공개 제4상 임상시험 (Nicardipine Hydrochloride Injectable Phase IV Clinical Trial-Study on the antihypertensive effect and safely of nicardipine for acute aortic dissection)

  • 김경환;문인성;박장상;고용복;안혁
    • Journal of Chest Surgery
    • /
    • 제35권4호
    • /
    • pp.267-273
    • /
    • 2002
  • 배경: 저자들은 한국인에 있어서의 급성대동맥박리에 대한 nicardipine의 혈압강하요법에 대한 임상적 유용성을 검토하고자 국내 제4상 임상시험을 실시하였다. 대상 및 방법: 31명의 대동맥 질환 환자에서 시험약의 투여 전후의 수축기 및 이완기 혈압, 심박수 등을 시간변화에 따라 비교 관찰하였다. 시험약식 투여기간은 원칙적으로 3일 이상 14일 이하로 하였으며, 투여 3일째의 평균혈압강하도를 평가하였다. 시험약 사용전 다른 강압제를 사용하고 있었던 경우는 기존 사용약제의 용량을 줄이면서 시험약으로 대체하여 결국 기존 사용약제를 사용하지 않는 것을 원칙으로 하였다. 결과: 연구의 대상이 된 환자는 급성 대동맥 박리가 28명, 대동맥궁류 파열이 2명, 외상성 대동맥 파열이 1명이었다. 연령은 53.9$\pm$14.9(29~89)세였고, 남자가 21명 (67.7%)이었다. 대동맥질환에 기인한 합병증은 대동맥판 폐쇄부전이 7례, 혈성심낭 6례, 급성 신부전 1례, 하지마비 1례, 하지허혈 1례 등이었다. 목표혈압 도달은 15분이내가 16례로 가장 많았고, 15분이상 30분이내가 10명, 30분이상 45분이내가 3명, 45분이상 60분 이내에 도달한 경우가 2명이었다. 관찰기 혈압은 수축기혈압, 이완기혈안, 평균혈압이 각각 147$\pm$23mmHg, 82.3$\pm$18.6mmHg, 104$\pm$18mmHg이었고, 3일째 측정하였을 때 119$\pm$12mrnHg, 69$\pm$grnmHg, 86$\pm$BmmHg로 의미있게 감소하였음을 확인하였다. Nicardipine 투여 종료 시에측정한 수축기 혈압, 이완기혈압, 평균혈압은 각각 119$\pm$ 15mmHg, 70$\pm$ 14mmHg, 86$\pm$ 13mmHg로 3일째 측정한 혈압과 비교하였을 때 의미있는 상승 혹은 하강현상은 관찰되지 않았고 비교적 혈압 하강 상태가 잘 유지되고 있음을 알 수 있었다. 지속적 정맥 투여 중 부작용은 뚜렷하게 관찰할 수 없었다. 결론: 대동맥 박리에 동반된 고혈압에서 nicardipine을 사용하여 만족할만한 혈압하강 효과를 얻었으며, 뚜렷한 부작용이 없이 안전하게 사용할 수 있다는 결론을 내렸다.

소규모 기업에 있어서 지식소싱 전략이 기업성과에 미치는 영향 고찰 (An Examination of Knowledge Sourcing Strategies Effects on Corporate Performance in Small Enterprises)

  • 최병구
    • Asia pacific journal of information systems
    • /
    • 제18권4호
    • /
    • pp.57-81
    • /
    • 2008
  • Knowledge is an essential strategic weapon for sustaining competitive advantage and is the key determinant for organizational growth. When knowledge is shared and disseminated throughout the organization, it increases an organization's value by providing the ability to respond to new and unusual situations. The growing importance of knowledge as a critical resource has forced executives to pay attention to their organizational knowledge. Organizations are increasingly undertaking knowledge management initiatives and making significant investments. Knowledge sourcing is considered as the first important step in effective knowledge management. Most firms continue to make an effort to realize the benefits of knowledge management by using various knowledge sources effectively. Appropriate knowledge sourcing strategies enable organizations to create, acquire, and access knowledge in a timely manner by reducing search and transfer costs, which result in better firm performance. In response, the knowledge management literature has devoted substantial attention to the analysis of knowledge sourcing strategies. Many studies have categorized knowledge sourcing strategies into intemal- and external-oriented. Internal-oriented sourcing strategy attempts to increase firm performance by integrating knowledge within the boundary of the firm. On the contrary, external-oriented strategy attempts to bring knowledge in from outside sources via either acquisition or imitation, and then to transfer that knowledge across to the organization. However, the extant literature on knowledge sourcing strategies focuses primarily on large organizations. Although many studies have clearly highlighted major differences between large and small firms and the need to adopt different strategies for different firm sizes, scant attention has been given to analyzing how knowledge sourcing strategies affect firm performance in small firms and what are the differences between small and large firms in the patterns of knowledge sourcing strategies adoption. This study attempts to advance the current literature by examining the impact of knowledge sourcing strategies on small firm performance from a holistic perspective. By drawing on knowledge based theory from organization science and complementarity theory from the economics literature, this paper is motivated by the following questions: (1) what are the adoption patterns of different knowledge sourcing strategies in small firms (i,e., what sourcing strategies should be adopted and which sourcing strategies work well together in small firms)?; and (2) what are the performance implications of these adoption patterns? In order to answer the questions, this study developed three hypotheses. First hypothesis based on knowledge based theory is that internal-oriented knowledge sourcing is positively associated with small firm performance. Second hypothesis developed on the basis of knowledge based theory is that external-oriented knowledge sourcing is positively associated with small firm performance. The third one based on complementarity theory is that pursuing both internal- and external-oriented knowledge sourcing simultaneously is negatively or less positively associated with small firm performance. As a sampling frame, 700 firms were identified from the Annual Corporation Report in Korea. Survey questionnaires were mailed to owners or executives who were most erudite about the firm s knowledge sourcing strategies and performance. A total of 188 companies replied, yielding a response rate of 26.8%. Due to incomplete data, 12 responses were eliminated, leaving 176 responses for the final analysis. Since all independent variables were measured using continuous variables, supermodularity function was used to test the hypotheses based on the cross partial derivative of payoff function. The results indicated no significant impact of internal-oriented sourcing strategies while positive impact of external-oriented sourcing strategy on small firm performance. This intriguing result could be explained on the basis of various resource and capital constraints of small firms. Small firms typically have restricted financial and human resources. They do not have enough assets to always develop knowledge internally. Another possible explanation is competency traps or core rigidities. Building up a knowledge base based on internal knowledge creates core competences, but at the same time, excessive internal focused knowledge exploration leads to behaviors blind to other knowledge. Interestingly, this study found that Internal- and external-oriented knowledge sourcing strategies had a substitutive relationship, which was inconsistent with previous studies that suggested complementary relationship between them. This result might be explained using organizational identification theory. Internal organizational members may perceive external knowledge as a threat, and tend to ignore knowledge from external sources because they prefer to maintain their own knowledge, legitimacy, and homogeneous attitudes. Therefore, integrating knowledge from internal and external sources might not be effective, resulting in failure of improvements of firm performance. Another possible explanation is small firms resource and capital constraints and lack of management expertise and absorptive capacity. Although the integration of different knowledge sources is critical, high levels of knowledge sourcing in many areas are quite expensive and so are often unrealistic for small enterprises. This study provides several implications for research as well as practice. First this study extends the existing knowledge by examining the substitutability (and complementarity) of knowledge sourcing strategies. Most prior studies have tended to investigate the independent effects of these strategies on performance without considering their combined impacts. Furthermore, this study tests complementarity based on the productivity approach that has been considered as a definitive test method for complementarity. Second, this study sheds new light on knowledge management research by identifying the relationship between knowledge sourcing strategies and small firm performance. Most current literature has insisted complementary relationship between knowledge sourcing strategies on the basis of data from large firms. Contrary to the conventional wisdom, this study identifies substitutive relationship between knowledge sourcing strategies using data from small firms. Third, implications for practice highlight that managers of small firms should focus on knowledge sourcing from external-oriented strategies. Moreover, adoption of both sourcing strategies simultaneousiy impedes small firm performance.

국가원수 경호적 측면에서의 EMP(Electro Magnetic Pulse) 방호 시스템에 대한 고찰 (Aspect of the chief of state guard EMP (Electro Magnetic Pulse) protection system for the consideration)

  • 정주섭
    • 시큐리티연구
    • /
    • 제41호
    • /
    • pp.37-66
    • /
    • 2014
  • 최근 전자공학의 급격한 발달로 컴퓨터와 전자 통신 기술에 의존도가 높아지고 있으며 각 부분이 상호 연계되어 모든 전자 장비를 무용지물로 만드는 EMP에 의한 직접적 또는 간접적인 피해가 발생하고 있다. 대한민국과 긴박한 대치 상황에 놓여 있는 북한은 상당한 수준의 EMP 관련 기술을 가지고 있으며, EMP 무기를 이미 보유했거나 수년 내 EMP 무기의 개발을 완료할 것으로 전망하고 있다. 북한은 장거리 미사일발사 직후에 여러 차례 핵실험을 실시하였으며 노골적인 핵 협박 공세가 강화되었음을 보았을 때, 고고도 핵실험을 언제라도 할 수 있는 능력을 보유하였다고 보아야 하며, 이는 EMP 무기의 실전적인 공격능력이 갖추어 졌다는 것을 의미한다고 할 것이다. 이러한 시점에서 피해상황을 예측하여 대한민국의 안보현실에 부합되는 EMP 방호시스템의 구축은 무엇보다도 필요한 과제이다. 그 피해의 규모는 예측 불가하지만 크게 군사적 피해와 사회 경제적 피해 그리고 인명피해상황으로 구분해 보았을 때 통신 시스템 및 위성장비의 마비를 시작으로 군사안보시스템과 수송, 금융, 국가비상체계 등 여러 부문으로 피해가 나타난다. 일반적으로 EMP는 직접적인 인명피해는 없다고 보고되지만 의료기기에 의존하는 사람들에게는 치명적인 피해가 나타날 수 있다. 또한, 국가전력체계 마비로 인한 전력공급중단이 가져다주는 피해만 생각 할 것이 아니라 주 전력발전 중 원자력발전소 의존도가 높은 국내는 블랙아웃현상발생 시 심각한 원전사고로 이어질 수 있는 발전소 내부의 문제점도 예측해 보아야 한다. 우선 특별 전문 위원회를 구성하여 EMP 방호시설 및 장비에 대한 수요조사를 실시하고, 그에 맞는 소요예산을 구성하여 엄격한 기준 아래 시공업체를 선별하여야 한다. 그 후 EMP 방호성능검증을 위한 기관을 만들어 성능을 검증 한 후 유지 보수 안전 및 설계 시공회사 보안 관리를 하는 조직적이고 체계적인 과정을 거쳐 경호시설물이나 경호통신장비 기동장비 등에 대한 완벽한 EMP 방호시스템을 갖추어 놓아야 할 것이다.

  • PDF

복막 투석 환자에서 도관 관련 감염 및 복막염에 대한 Mupirocin과 도관 전환술(Catheter revision)의 효과 (The Effects of Catheter Revision and Mupirocin on Exit Site Infection/Peritonitis in CAPD Patients)

  • 박준범;김정미;최준혁;조규향;정항재;김영진;도준영;윤경우
    • Journal of Yeungnam Medical Science
    • /
    • 제16권2호
    • /
    • pp.347-356
    • /
    • 1999
  • 복막 투석은 혈액 투석 및 신 이식과 함께 말기 신 질환의 중요한 치료 방법의 하나로 성공적인 복막 투석을 위해서는 복막 투석에 따른 여러 합병증을 줄이는 것이 필수적이다. 그러나 도관 출구 감염이나 복막염 등 투석 관련 감염은 여전히 도관 제거로 인한 복막 투석의 중단을 유발하는 중요한 원인이 되고 있다. 영남대학 의과대학 부속병원에서 1993년 10월부터 1999년 2월까지 복막 투석을 시행 후 추적 가능한 139명의 환자를 대상으로 도관 출구 감염과 복막염의 발생 빈도 및 원인 균주, 도관 제거의 빈도 및 원인 균주, 도관 전환술의 성적, 그리고 mupirocin ointment 사용 전과 사용 후의 도관 출구 감염의 빈도 차이 등을 후향 분석하였다. 복막 투석을 시행한 총 환자-투석기간은 2,401개월이었고 도관 출구 감염은 36명의 환자에서 105례 발생하여 발생 빈도는 1/22.8 환자-개월이었고 복막염은 67명의 환자에서 112례 발생하여 그 빈도는 1/21.4 환자-개윌로 나타났다. 대다수 출구 감염의 경우 일반적인 투약에 잘 반응하였으나 치료에 불응하여 도관 전환술을 시행한 7명 중 5명은 메티실린 저항성 포도상 구균(Methicillin Resistant, Staphylococcus aureus, MRSA), 2명은 Pseudomonas aeruginosa에 의한 감염이었다. revision후 3명에서 감염이 재발하였으나 한 명은 항생제에 바로 치유되었고 또 한 명은 second revision으로 치료하였으며 나머지 한 명은 MRSA에 의한 반복 감염이 지속되어 결국 도관 제거와 동시에 도관 재삽입을 시행하였다. 재발에 대한 치료 후 평균 추적기간 14.0개월 동안 더 이상의 출구 감염은 없었다. 1998년 10월부터 1999년 2월까지 mupirocin을 국소 도포 한 34명의 환자를 살펴보면, pre-mupirocin 기간의 총 투석기간은 687개월이었고 그 기간동안 도관 출구 감염이 54례 발생하여 발생 빈도는 1/12.7 환자-개월로 나타났으나 mupirocin 기간의 경우 총 투석기간 136개월 동안 4례 발생하여 그 빈도가 1/34.0 환자-개월로 유의하게(P<0.01) 감소하였다. 도관 출구 감염의 72.2%가 SA에 의한 것으로 조기에 적절한 항생제 치료를 함으로써 대부분 완치되었고 일부 약제에 잘 반응하지 않고 반복 감염되어 도관 탈락의 위험이 있는 경우에도 도관 전환술을 통하여 비교적 안전하고 효과적으로 난치성 출구 감염을 치유할 수 있었다. 그리고 도관 출구 부위에 mupirocin을 간헐적으로 국소 도포 함으로써 포도상 구균(Staphylococcus aureus)에 의한 출구 감염을 예방할 수 있었다. 그러나 이러한 도관 전환술과 mupirocin의 장기적인 효과 및 부작용에 대해서는 보다 많은 환자군을 대상으로 하는 전향적 연구가 있어야 할 것으로 생각된다.

  • PDF

산부식 전처리에 따른 2단계 자가부식 접착제의 연마 법랑질에 대한 미세인장결합강도 (The micro-tensile bond strength of two-step self-etch adhesive to ground enamel with and without prior acid-etching)

  • 김유리;김지환;심준성;김광만;이근우
    • 대한치과보철학회지
    • /
    • 제46권2호
    • /
    • pp.148-156
    • /
    • 2008
  • 자가부식 접착제는 사용하기 쉽고, 술식 민감성이 적은 장점이 있으나 특히 산도가 약한 자가부식 접착제의 법랑질에 대한 결합력은 논란이 되고 있다. 본 연구에서는 2단계 자가부식 접착제인 Clearfil SE Bond (Kuraray, Okayama, Japan)의 연마 법랑질에 대한 미세인장 결합강도를 측정하여 3단계 산부식수세 접착제인 Scotchbond Multi-Purpose (3M ESPE, St. Paul, MN, USA) 및 1단계 자가부식 접착제인 iBond (Heraeus Kulzer Gmbh, Hanau, Germany)의 결합강도와 비교하고자 하였고, 2단계 자가부식 접착제에 산부식 전처리를 시행하는 것이 법랑질에 대한 결합강도를 높일 수 있는지 알아 보고자 하였다. 실험군은 2단계 자가부식 접착제인 Clearfil SE Bond만 사용한 비산부식 군과 35% 인산 (Scotchbond Etchant, 3M ESPE)으로 산부식 후 Clearfil SE Bond를 사용한 산부식 군, 그리고 1단계 자가부식 접착제인 iBond를 사용한 군으로 나누었다. 대조군은 3단계 산부식수세 접착제인 Scotchbond Multi-Purpose를 사용한 군으로 정하였다. Bovine 전치의 순면을 십자가형으로 4등분하여 각 군으로 무작위로 배분하였다. 각 치아의 순면을 800-grit 실리콘 카바이드 지로 연마한 후 삭제된 법랑질면에 제조사의 설명서에 따라 각 군의 접착제를 적용하고 Light-Core (Bisco)로 적층 충전하였다. 시편은 $37i{\acute{E}}$, 증류수에 일주일 동안 보관한 후 low speed precicion diamond saw (TOPMENT Metsaw-LS, R&B, Daejeon, Korea)를 이용하여 약 $0.8{\times}0.8mm$ 단면이 되도록 시편을 절단하여 미세시편을 제작하였다. 일주일마다 증류수를 교환하면서 한 달, 세 달 동안 $37i{\acute{E}}$, 증류수에 미세시 편을 보관한 후 각각의 미세인장결합강도를 측정하였다. 미세인장결합강도 (MPa)는 파절 시에 가해진 힘 (N)을 접착면적 ($mm^2$)으로 나누어 계산하였다. 접착계면에서의 파절 양상은 실물현미경 (Microscope-B nocular, Nikon)을 이용하여 분류하였다. 미세인장결합강도에 대한 통계분석은 one-way ANOVA를 이용하여 유의수준 5%에서 검정하였고, 사후감정은 Least Significant Difference 방법을 이용하였다. 중합 후 1개월 뒤 측정된 각각의 접착제의 평균 미세인장결합강도는 유의수준 5%에서 모든 접착제 간에 유의한 차이가 없었다. 3개월 뒤 측정된 각각의 접착제의 평균 미세인장결합강도는 유의수준 5%에서 iBond 와 Clearfil SE Bond 비산부식 군과 Scotchbond Multi- Purpose 간에는 각각 유의한 차이가 없었다. 본 연구에서는 2단계 자가부식 접착제인 Clearfil SE Bond의 연마 법랑질에 대한 미세인장결합강도가 3단계 산부식수세 접착제인 Scotchbond Multi-Purpose 와 비교하여 유의한 차이가 없었으며 (P>0.05), 3개월 후의 결과에서 Clearfil SE Bond 비산부식 군의 미세인장결합강도가 Clearfil SE Bond 산부식 군보다 유의하게 낮았다 (P<0.05). 즉 35% 인산으로 산부식 전처리를 시행한결과 Clearfil SE Bond 의 법랑질에 대한 결합강도가 증가하였다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF