• 제목/요약/키워드: No Connection

검색결과 935건 처리시간 0.029초

A study on rotational behaviour of a new industrialised building system connection

  • Moghadasi, Mostafa;Marsono, Abdul Kadir;Mohammadyan-Yasouj, Seyed Esmaeil
    • Steel and Composite Structures
    • /
    • 제25권2호
    • /
    • pp.245-255
    • /
    • 2017
  • The performance of an Industrialised Building System (IBS) consists of prefabricated reinforced concrete components, is greatly affected by the behaviour of the connection between beam and columns. The structural characteristics parameters of a beam-to-column connection like rotational stiffness, strength and ductility can be explained by load-rotation relationship of a full scale H-subframe under gravitational load. Furthermore, the connection's degree of rigidity directly influences the behaviour of the whole frame. In this research, rotational behaviour of a patented innovative beam-to-column connection with unique benefits like easy installation, no wet work, no welding work at assembly site, using a hybrid behaviour of steel and concrete, easy replacement ability, and compatibility with architecture was investigated. The proposed IBS beam-to-column connection includes precast concrete components with embedded steel end connectors. Two full-scale H-subframes constructed with a new IBS and conventional cast in-situ reinforced concrete system beam-to-column connections were tested under incremental static loading. In this paper, load-rotation relationship and ratio of the rigidity of IBS beam-to-column connection are studied and compared with conventional monolithic reinforced concrete connection. It is concluded that this new IBS beam-to-column connection benefits from more rotational ductility than the conventional reinforced concrete connection. Furthermore, the semi-rigid IBS connection rigidity ratio is about 44% of a full rigid connection.

플라스틱 온실의 강관 이음부 휨성능 분석 (Evaluation of Steel-Pipe Connections in Plastic Greenhouse Using Bending Test)

  • 최만권;류희룡;조명환;유인호
    • 생물환경조절학회지
    • /
    • 제27권4호
    • /
    • pp.391-399
    • /
    • 2018
  • 본 연구에서는 현장에서 사용되는 온실 강관의 이음 방법에 대해 휨성능을 평가하고 그 결과를 바탕으로 가장 휨성능이 우수한 이음 방법을 알아보았다. 실험 결과, 모든 실험체는 이음이 없는 실험체 보다 휨성능이 작았다. 그러나 모든 실험체의 최대 휨모멘트는 이음이 없는 실험체 소성모멘트의 1.07~1.3정도로 나타났다. 또한 연결방법에 따른 결과는 연결핀 보다 인발 실험체가 상대적으로 큰 휨성능을 보였다. 현장 이음 방법의 파괴 모드는 연결핀과 강관 끝부분의 응력집중에 의한 국부좌굴이 지배적이었다. 현장시공 시 강관을 절단 후 연결할 경우, 이음 없이 사용하는 것이 가장 우수한 휨성능을 발휘하지만 부득이 강관을 절단할 경우는 연결핀보다는 인발 강관에 직결나사로 고정한 이음 방법(SPJ-F)으로 시공하는 것이 유리할 것으로 판단된다.

Dual-Domain Connection Scheme for HE-AAC and MPEG Surround

  • Pang, Hee-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • 제28권1E호
    • /
    • pp.29-34
    • /
    • 2009
  • MPEG4 High Efficiency Advanced Audio Coding (HE-AAC) and MPEG Surround are one of the most efficient combinations for low bit rate multi-channel audio coding. Based on the fact that these two codecs have identical quadrature mirror filter (QMF) analysis and synthesis structures, we propose a dual-domain connection scheme for the codecs. Specifically two time-domain connection methods are analyzed and compared to the QMF subband-domain connection method. Experimental results show that both the time-domain connection methods cause no subjective sound quality degradation compared to the QMF subband-domain connection method, which verifies that one can select either of them depending on application scenarios.

임플랜트 지대주에 따른 나사 풀림의 연구 (THE INFLUENCE OF IMPLANT FIXTURE-ABUTMENT CONNECTION DESIGN ON SCREW LOOSENING)

  • 문양숙;박상원;방몽숙;양홍서;박하옥
    • 대한치과보철학회지
    • /
    • 제44권2호
    • /
    • pp.174-184
    • /
    • 2006
  • Purpose: Current trend in implant dentistry is changing from external connection to internal connection. To evaluate the splinting of external and internal connection implant on screw loosening, 2-units prosthesis was fabricated with BioPlant $System^(R)$ of external connection type and Lifecore STAGE-1 Single Stage Implant $System^(R)$ of internal connection type. Material and Method: Experimental group is classified into three groups. 1) $G_1-EE$: 2-units prosthesis was fabricated with two Bioplant $System^(R)$ of external connection type. 2) $G_1-EI$: 2-units prosthesis was fabricated with one BioPlant $System^(R)$ of external connection type and one Lifecore STAGE-1 Single Stage Implant $System^(R)$ of internal connection type. 3) $G_1-II$: 2-units prosthesis was fabricated with two Lifecore STAGE-1 Single Stage Implant $System^(R)$ of internal connection type. In fabricating 2-units prosthesis, two hexed abutments are recommended when two implants are installed parallel, otherwise one hexed abutment is used on major occlusal force area and one nonhexed abutment is used on the other area. Since it is rare to find two implants being parallel, it is hard to fabricate prosthesis with passive adaptation using two hexed abutments. It is much more difficult to acquire passive adaptation when using hex abutment compared to nonhex abutment. To evaluate the influence of hexed and nonhexed abutment on screw loosening, 2-units prosthesis was fabricated with hexed and nonhexed abutment. Experimental group is classified into three groups. 1) $G_2-HH$: 2-units prosthesis was fabricated with two hexed abutments. 2) $G_2-HN$: 2-units prosthesis was fabricated with one hexed abutment and one nonhexed abutment. 3) $G_2-NN$: 2-units prosthesis was fabricated with two nonhexed abutments. Result: The results of comparing the detorque value after loading on a each prosthesis periodically are as follows. 1. In splinting group of external and internal connection implant, $G_1-II$ group demonstrated the biggest detorque value, followed by $G_1-EI$ group and $G_1-EE$ group. 2. There is no notable significance between external connection implant of $G_1-EI$ group and $G_1-EE$ group and also no significance between internal connection implant of $G_1-EI$ group and $G_1-II$ group. 3. $G_2-HH$ group showed higher detorque value than $G_2-HN\;and\;G_2-NN$ group. From the results, we can concluded that using both external connection and internal connection implant together is clinically acceptable and in order to acquire a good passive adaptation in fabricating 2-units implant prosthesis we can use two nonhexed abutments.

주요 신경과의 연결이 없이 발생한 긴손바닥근의 신경초종 (Neurilemoma Localized in the Palmaris Longus Tendon with no Connection to the Major Nerve Trunk)

  • 박정용;정성노;손원일;권호
    • Archives of Plastic Surgery
    • /
    • 제38권4호
    • /
    • pp.498-500
    • /
    • 2011
  • Purpose: Neurilemoma is benign tumor of the nerve sheath which arises from Schwann cells. It is usually formed along the path of a peripheral nerve but is rarely separate from normal nerve fascicles. We experienced a patient with an isolated neurilemoma localized in the palmaris longus tendon with no connection to the major nerve trunk, which was in an unusual location and has never been reported. We report our case with the review of the literature. Methods: A 23-year-old female visited our clinic with mild pain on the mass at the flexor area of the right wrist which had been present for about one year. The physical examination revealed a $1{\times}1cm$ sized subcutaneous mass at the flexor area of the right wrist. Sonography and computed tomography showed an ovoid, superficial solid mass on the palmaris longus tendon. Upon surgical excision, a $1{\times}0.5cm$ sized mass attached to the palmaris longus tendon was found. The tumor had no connection with the median nerve and was detached easily from the palmaris longus tendon. Results: Histological examination demonstrated the mass to be a neurilemoma, which consists of spindle shaped cells with oval elongated nuclei arranged fascicles. No sensory dysfunction or evidence of recurrence was found during the 12 months of postoperative follow-up. Conclusion: We experienced a rare case of neurilemoma attached to the palmaris longus tendon with no connection to the major nerve trunk. We wish to emphasize its unusual location through our case and hope to expand our spectrum in exploring the upper extremity mass.

Seismic and progressive collapse assessment of SidePlate moment connection system

  • Faridmehr, Iman;Osman, Mohd Hanim;Tahir, Mahmood Bin Md.;Nejad, Ali Farokhi;Hodjati, Reza
    • Structural Engineering and Mechanics
    • /
    • 제54권1호
    • /
    • pp.35-54
    • /
    • 2015
  • The performance of a newly generated steel connection known as SidePlateTM moment connection for seismic loading and progressive collapse phenomenon has been investigated in this paper. The seismic evaluation portion of the study included a thorough study on of interstory drift angles and flexural strengths based on 2010 AISC Seismic Provisions while the acceptance criteria provided in UFC 4-023-03 guideline to resist progressive collapse must be satisfied by the rotational capacity of the connections. The results showed that the SidePlate moment connection was capable of attaining adequate rotational capacity and developing full inelastic capacity of the connecting beam. Moreover, the proposed connection demonstrated an exceptional performance for keeping away the plastic hinges from the connection and exceeding interstory drift angle of 0.06 rad with no fracture developments in beam flange groove-welded joints. The test results indicated that this type of connection had strength, stiffness and ductility to be categorized as a rigid, full-strength and ductile connection.

Analogical Transfer: Sequence and Connection

  • LIM, Mi-Ra
    • Educational Technology International
    • /
    • 제9권1호
    • /
    • pp.79-96
    • /
    • 2008
  • The issue of connection between entities has a lengthy history in educational research, especially since it provides the necessary bridge between base and target in analogical transfer. Recently, the connection has been viewed through the application of technology to bridge between sequences in order to be cognitively useful. This study reports the effect of sequence type (AT vs. TA) and connection type (fading vs. popping) on the achievement and analogical transfer in a multimedia application. In the current research, 10th -grade and 11th -grade biology students in Korea were randomly assigned to five groups to test the effects of presentation sequence and entity connection type on analogical transfer. Consistent with previous studies, sequence type has a significant effect: analogical transfer performance was better when base representations were presented first followed by target representations rather than the reverse order. This is probably because presenting a familiar base first helps in understanding a less familiar target. However, no fully significant differences were found with the entity connection types (fading vs. popping) in analogical transfer. According to the Markman and Gentner's (2005) spatial model, analogy in a space is influenced only by the differences between concepts, not by distance in space. Thus connection types fail on the basis of this spatial model in analogical transfer test. The findings and their implications for sequence and connection research and practice are discussed. Leveraging on the analogical learning process, specific implications for scaffolding learning processes and the development of adaptive expertise are drawn.

연성적인 접합부를 가진 프리캐스트 콘크리트 골조건물의 변형수요 (Deformation Demand of the Precast Concrete Frame Buildings with Ductile Connection in Moderate Seismic Regions)

  • 서수연;이리형
    • 콘크리트학회논문집
    • /
    • 제11권5호
    • /
    • pp.89-98
    • /
    • 1999
  • This paper evaluates nonlinear response characteristics of precast concrete frame buildings. where plastics hinging occurs in the precast connection. Designs were developed for buildings of 5, 10 and 15 stories in hight for moderate seismic risk regions of the U. S. The responses of the buildings were analyzed using DRAIN-2DX and following Nonlinear static analysis procedure of ATC 19. The main variables of the analyses were the strength and stiffness of the connection. Also, for the analysis, the bi-linear response model, developed and inserted into the DRAIN-2DX program by Shan Shi and D. Fouch, was used. With the results of analysis, the deformation demands of the connection of precast concrete frame buildings are proposed by using equal-dissipated energy capacity. It was shown that the strength of the buildings as well as their displacement capacities decreased with the decrease of either the strength or stiffness in the connections. Therefore such changes also require reductions in the response modification factors for such buildings. However, if the precast concrete frame building has plastic hinging in the connection, and has a more ductile connection than the monolithic frame building, then no reduction in R may be necessary. The deformation demand required of the connection to achieve that condition is evaluated and a simple relation is suggested in the paper.

Central angle effect on connection behavior of steel box beam-to-circular column

  • Hwang, Won-Sup;Kim, Young-Pil;Yoon, Tae-Yang
    • Structural Engineering and Mechanics
    • /
    • 제32권4호
    • /
    • pp.531-547
    • /
    • 2009
  • This paper presents the experimental results on the strength behavior and failure modes of box beam-to-circular column connections in steel piers. Previous research introduced parameters such as joint central angles, extension of horizontal stiffeners, and use of equivalent web depth, which ignored strength behavior and failure modes of box beam-to-circular column connections. The use of equivalent web depth $d_2$ is not reasonable when central angle ${\alpha}$ is closer to $90^{\circ}$; therefore, a monotonic loading test has been performed for eight connection specimens. From the test, it is identified that the connection with the circular column is stronger than the connection with the box-sectioned substitution column. Also, the strength of the beam-to-column connections with horizontal stiffeners is higher than the one of the no column stiffeners. The concrete-filled effect of box beam-to-circular column connection is also investigated, and the experimental yield strength of the connection is compared with the theoretical one. Also, more a reasonable equivalent web depth is suggested. The failure modes of connection are clearly defined.

Effect of vertical reinforcement connection level on seismic behavior of precast RC shear walls: Experimental study

  • Yun-Lin Liu;Sushil Kumar;Dong-Hua Wang;Dong Guo
    • Earthquakes and Structures
    • /
    • 제26권6호
    • /
    • pp.449-461
    • /
    • 2024
  • The vertical reinforcement connection between the precast reinforced concrete shear wall and the cast-in-place reinforced concrete member is vital to the performance of shear walls under seismic loading. This paper investigated the structural behavior of three precast reinforced concrete shear walls, with different levels of connection (i.e., full connection, partial connection, and no connection), subjected to quasi-static lateral loading. The specimens were subjected to a constant vertical load, resulting in an axial load ratio of 0.4. The crack pattern, failure modes, load-displacement relationships, ductility, and energy dissipation characteristics are presented and discussed. The resultant seismic performances of the three tested specimens were compared in terms of skeleton curve, load-bearing capacity, stiffness, ductility, energy dissipation capacity, and viscous damping. The seismic performance of the partially connected shear wall was found to be comparable to that of the fully connected shear wall, exhibiting 1.7% and 3.5% higher yield and peak load capacities, 9.2% higher deformability, and similar variation in stiffness, energy dissipation capacity and viscous damping at increasing load levels. In comparison, the seismic performance of the non-connected shear wall was inferior, exhibiting 12.8% and 16.4% lower loads at the yield and peak load stages, 3.6% lower deformability, and significantly lower energy dissipation capacity at lower displacement and lower viscous damping.