• Title/Summary/Keyword: Nitrogen recovery

Search Result 337, Processing Time 0.027 seconds

The Toxicity of Nitrogen Dioxide Gas on Fig Plant (이산화질소 가스에 의한 무화과 나무의 피해 양상)

  • Kim, Yoo-Hak;Choi, Byeong-Ryeol;Kim, Myung-Sook
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.6
    • /
    • pp.978-980
    • /
    • 2010
  • This study was conducted to observe the cause of injury of fig plant. Nitrogen dioxide gas can be evolved at low pH or reduced in soil. Fig plant cultivated with nutrient solution was wilted or withered. Injury symptom for nutrient solution containing nitrous acid was worse as pH of soil decreased. However, increase in pH of nutrient solution treated with increasing $Ca(OH)_2$ solution prevented nutrient solution from producing nitrogen dioxide gas. Recovery of the fig plant by pH increase indicated that the cause of injury was nitrogen dioxide gas.

Effects of Nitrogen Recovery of Satuma Mandarins with Different Nitrogen Rates and Application Methods (질소시비량과 시비방법에 따른 온주밀감의 질소회수율)

  • Kang, Young-Kil;U, Zang-Kual
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.31 no.4
    • /
    • pp.342-349
    • /
    • 1998
  • In order to evaluate the effects of nitrogen (N) rate and application method on the recovery of N fertilizer applied in spring and summer by Satsuma mandarins (cv. Miyakawa Wase), N as urea was surface-applied at the rates of 50 (applied with 20 mm water; 50% N application) and 100% (three treatments; applied as solid, with 5 or 20 mm water) of the recommended rate ($150kg\;ha^{-1}\;yr^{-1}$) on 25 March and 12 June with an application ratio of 50 and 20%. The labeled N was applied only once in spring or summer. There were no differences among the four treatments in fruit yield, fruit quality except acid content of juice, and N content of leaves. The recovery of fertilizer N applied in spring by a tree ranged from 7.8 to 8.3% and that of N applied in summer ranged from 11.3 to 14.2% at the three recommended N rates and was 18.0% for the 50% N application. The recovery of fertilizer N applied in spring in the upper 40 cm of soil ranged from 32.1 to 37.7% at the three recommended N rates and was 55.8% at the 50% N application. For N applied in summer, it was 69.8% for surface application of the recommended N rate and ranged from 80.7 to 84.4% for the three N applications with water. The total (tree+soil) recovery of N fertilizer applied in spring was highest (64.1%) for the 50% N application and ranged from 40.3 to 45.5% for the three recommended N rates. The total recovery of N fertilizer applied in summer was also highest (99.4%) for the 50% N application and tended to be higher for the application of N with water than surface application and to increase with increasing irrigation amount of N application.

  • PDF

A Study of the Metal Recovery from the Aluminium Scrap (Al 스크랩으로부터 금속회수에 관한 연구)

  • 김준수;임병모;윤의박
    • Resources Recycling
    • /
    • v.4 no.1
    • /
    • pp.25-30
    • /
    • 1995
  • In the preparatIon of reclaimed aluminium lllgot from alumimum scrap, the aluminium recovery was studied a as a function of the preliminary treatment of samples, addition of flux and melting atmosphere. AI dross is produced by an oxidation reaction at the surface of liquid metal. The recovery of AI metal increases u up to maximum 95% by adding salt up to 7%, The recovery of AI metal in the compacted chip bale without oil removal mcrease about 14% compared io non-compacted chip. In the case of the AI seed melting process, the recovery of Al metal of the crushed and compacted chip hale is 97%, In meltmg of alumimum scrap under the atmosphere of carbon and nitrogen gas, the recovery of AI metal increase, but it is decreased when the mixture of salt and carbon powder is added excessively.

  • PDF

Research on the Methane Recovery from Landfill Gas by Applying Nitrogen Gas Separator Membrane (질소 분리용 막을 이용한 매립가스내 메탄 회수 연구)

  • Chun, Seung-Kyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.8
    • /
    • pp.586-591
    • /
    • 2013
  • This experiment was performed to enhance $CH_4$ purity of landfill gas by applying gas separator membrane for purified nitrogen gas production. 1:6 area ratios of $1^{st}$ to $2^{nd}$ membrane module was suitable for $CH_4$ recovery. After separation membrane system was installed, 249 tries were performed. Average permeability for $CH_4$ was 28.4% and for $CO_2$ was 94.3%. This can explain nitrogen gas separator membrane can be applied to collect $CH_4$ from LFG. However, nitrogen permeability only reached up to 16.5%. Therefore, the final purified landfill gas concentration was rounded up to 69.7% for $CH_4$, 4.3% for $CO_2$ and 26.0% for $N_2$. For the high degree of $CH_4$ purity, $N_2$ should be kept at least under 2.0% by controlling air inflow to landfill.

Effect of Nitrogen-Load Condition on Hydrogen Production and Bacterial Community in Continuous Anaerobic Hydrogen Fermentation Process

  • Kawagoshi, Yasunori;Nakao, Masaharu;Hino, Naoe;Iwasa, Tomonori;Furukawa, Kenji
    • Journal of Wetlands Research
    • /
    • v.9 no.1
    • /
    • pp.123-131
    • /
    • 2007
  • Effect of nitrogen-load condition on hydrogen ($H_2$) production and bacterial community in a continuous anaerobic hydrogen fermentation were investigated. The slight $H_2$ production on extremely low nitrogen-load condition (C/N ratio: 180) at the start-up period. The highest $H_2$ production was obtained when the C/N ratio was 36, the $H_2$ production yield ($mol-H_2/mol-glucose$) reached to 1.7, and it was indicated that Clostridium pasteurianum mainly contributed to the $H_2$ production. The $H_2$ production was decreased on both the lower (C/N: 72) and higher (C/N: 18) nitrogen-load conditions. The excess nitrogen-load was not always suitable for the hydrogen production. The fluctuation of $H_2$ production seemed to be caused by a change in the bacterial community according to the nitrogen-load condition, while a recovery of $H_2$ productivity was possible by a control of nitrogen-load condition through the bacterial community change. When the nitrogen-load condition was not suitable for hydrogen production, the lactic acid concentration was increased and also lactic acid bacteria were definitely detected, which suggested that the competition between hydrogen fermentator and lactic acid producer was occurred. These results demonstrated that the nitrogen-load condition affect on the $H_2$ productivity through the change of bacterial community in anaerobic hydrogen fermentation.

  • PDF

Nitrogen-Oxygen Separation Characteristics by Polyimide Membrane System for Controlled Atmosphere Storage (CA저장을 위한 폴리이미드 막 시스템의 질소-산소 분리특성)

  • 이호원;현명택;고정삼
    • Food Science and Preservation
    • /
    • v.5 no.3
    • /
    • pp.239-246
    • /
    • 1998
  • Polyimide membrane system was designed for manufacturing nitrogen-enriched gas, and basic technical data was suggested for appling this system to controlled atmosphere storage. The permeability characteristics of pure oxygen and nitrogen could be explained by dual-mode sorption model. There was substantial decrease in the permeation rates of oxygen, which is the more permeable gas, through the polyimide membrane due to the presence of nitrogen in comparison with pure oxygen. However, the permeation rates of nitrogen was increased by the presence of oxygen. The ideal separation factor was in the range of 5 to 6 in the range of temperature and pressure difference studied, and the separation factor of air was lower than the ideal separation factor. The increase of ideal separation factor with increasing temperature is due to the fact that the activation energy for oxygen is larger than that for nitrogen. Nitrogen concentration decreased rapidly with increasing product recovery, and it was found that this is a major operating factor to obtain nitrogen concentration required for controlled atmosphere storage. A relation equation, by which nitrogen concentration in storehouse can be predicted, was suggested under the establishment of a hypothetical model for controlled atmosphere storage process using polyimide membrane system.

  • PDF

Quench and Recovery Characteristics of Non-Inductively Wound HTS Coils with Various Winding (권선방식에 따른 무유도 권선형 HTS 코일의 퀜치 및 회복 비교특성)

  • Jo, Hyun-Chul;Chang, Ki-Sung;Kim, Young-Jae;Choi, Suk-Jin;Hwang, Young-Jin;Kim, Won-Cheol;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.1
    • /
    • pp.37-41
    • /
    • 2010
  • To limit fault current in a power system, superconducting fault current limiters (SFCLs) using high temperature superconducting (HTS) coils have been developed by many research groups so far. Non-inductive winding of HTS coils used for SFCLs can be classified into solenoid winding and pancake winding. Each of winding is expected to have different quench and recovery characteristics because the structure of solenoid winding differs from pancake winding's. Therefore it is important to the SFCLs application to investigate characteristics of each winding. In this paper, we deal with quench and recovery characteristics of four kinds of winding : solenoid winding, pancake winding without spacers, and with spacers of 2 and 4 mm thickness. In order to obtain quench and recovery parameters of coils, short circuit tests were performed in liquid nitrogen.

Thermal diffusion experiment of impulsive heat in subcooled liquid nitrogen (과냉 액체질소 내에서 순간적 열확산 실험)

  • Choi, J.H.;Ha, J.C.;Byun, J.J.;Chang, H.M.;Kim, H.M.;Ko, T.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.1
    • /
    • pp.65-70
    • /
    • 2006
  • Transient heat transfer caused by an impulsive heating in subcooled liquid nitrogen is investigated experimentally. This study is part of out ongoing efforts directed to a stable cryogenic cooling system lot superconducting fault current limiters (SFCL). A thin heater attached by epoxy on one surface of a GFRP plate is immersed in liquid-nitrogen bath at temperatures between 77 K and 55 K. A strong heat flux up to $150W/cm^2$ is generated lot 100 ms, and the temperature of the heater sulfate is measured as a function of time. The behavior of bubbles on the heating surface can be explained by comparing the measured temperature history for vertical and two horizontal (up and down) orientations. It is concluded that the subcooling of liquid nitrogen below 70 K is very effective in suppressing bubbles, resulting in better thermal protection and faster recovery from an impulsive heat.

Influence of polymer coating on SFCL recovery under load

  • Gorbunova, D.A.;Kumarov, D.R.;Scherbakov, V.I.;Sim, Kideok;Hwang, Soon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.4
    • /
    • pp.44-47
    • /
    • 2019
  • This paper is a study of recovery under load process of superconducting fault current limiter (SFCL). SFCL consists of five parallel-connected high-temperature superconductor (HTS) tapes additionally stabilized by stainless tape. Previously, HTS was heated by current pulse to simulate a short circuit in a power grid. During the cooling period, the current amplitude decreased to 23% or less of HTS critical current value, which is the simulation of network re-switching. When HTS with a polymer coating is cooled, temperature gradient on thermal insulation layer occurs, that prevents a boiling crisis and improves the heat sink into liquid nitrogen. Two samples are coated with a 30 ㎛ and 50 ㎛ polylactide (PLA) layers, reference sample has no polymer coating on it. Samples with a polymer coating show 3-5 times faster cooling than the reference one.

Stability characteristics of DyBCO coated conductor stabilized with stainless steel

  • Dixit, Manglesh;Kim, Tae-Hyung;Oh, Sang-Soo;Song, Kyu-Jeong;Kim, Ho-Min;Park, Kwon-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.288-289
    • /
    • 2005
  • As high temperature superconductor applications became a reality due to increase in coated conductor performance, it is important to understand their stability behavior to design safe electrical power systems. We have experimentally studied the dependence of quench and recovery characteristics of coated conductors on the amplitude of current and duration time. The sample used in the present study is stabilized with stainless steel. Stability tests of 3 cm long sample were performed in a liquid nitrogen bath cooling condition by applying a short period over current pulses for 50 and 100 ms, with amplitude up to ~ 6 times of the critical current. The transport current that follows before and after the current pulse was fixed about ~85% the critical current. We analyzed the quench recovery using the current voltage characteristic.

  • PDF