• Title/Summary/Keyword: Nitrogen Ion Implantation

Search Result 68, Processing Time 0.023 seconds

Optical Reactivity Modification of Titanium Oxide coatings on Ceramic filters by Nitrogen ion Implantation

  • Kim, Hyeong-Jin;Park, Jae-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.90-90
    • /
    • 2010
  • We investigated the modification of optical response properties of titanium dioxide (TiO2) coatings on the ceramic water-purification filters by using ultraviolet-visible absorption spectroscopy and X-ray diffraction. The TiO2 coatings were prepared on ceramic substrate by e-beam evaporation method. These amorphous TiO2 were turned into anatase phase by heat treatment at $700^{\circ}C$ for 2 hours. The doping of N atoms into the TiO2 coatings was done by using 70KeV of N+ ion implantation with the dose of $1.0{\times}1017$ ions/cm2, followed by post-irradiation heat treatment at $550^{\circ}C$ for 2 hours. Methylene blue test of TiO2 coatings to solar irradiation showed that the post-evaporation heated TiO2 was photocatalytic and N-doped TiO2 reacted to the visible part of solar irradiation.

  • PDF

Fabrication of Ion Mass Analyzer and its Operational Characteristics (이온질량분석기의 제작과 그 동작특성)

  • Kim, Guang-Hoon;Choi, Young-Wook;Lee, Hong-Sik;Rim, Geun-Hie;Nikiforov, S.A.
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.8
    • /
    • pp.401-408
    • /
    • 2001
  • The information of the ion composition in plasma applications is required to characterize a plasma. A better understanding of ion species composition ratio and its spacial distribution, etc. is thus necessary in plasma-related processes, such as thin film deposition, plasma-based ion implantation, semiconductor processing, and so on. In this research, a compact ion mass analyzer that is based on magnetic sector analyzer was developed and its operational characteristics were studied in nitrogen plasma.

  • PDF

keV and MeV Ion Beam Modification of Polyimide Films

  • Lee, Yeonhee;Seunghee Han;Song, Jong-Han;Hyuneui Lim;Moojin Suh
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.170-170
    • /
    • 2000
  • Synthetic polymers such as polyimide, polycarbonate, and poly(methyl methacrylate) are long chain molecules which consist of carbon, hydrogen, and heteroatom linked together chemically. Recently, polymer surface can be modified by using a high energy ion beam process. High energy ions are introduced into polymer structure with high velocity and provide a high degree of chemical bonding between molecular chains. In high energy beam process the modified polymers have the highly crosslinked three-dimensionally connected rigid network structure and they showed significant improvements in electrical conductivity, in hardness and in resistance to wear and chemicals. Polyimide films (Kapton, types HN) with thickness of 50~100${\mu}{\textrm}{m}$ were used for investigations. They were treated with two different surface modification techniques: Plasma Source Ion Implantation (PSII) and conventional Ion Implantation. Polyimide films were implanted with different ion species such as Ar+, N+, C+, He+, and O+ with dose from 1 x 1015 to 1 x 1017 ions/cm2. Ion energy was varied from 10keV to 60keV for PSII experiment. Polyimide samples were also implanted with 1 MeV hydrogen, oxygen, nitrogen ions with a dose of 1x1015ions/cm2. This work provides the possibility for inducing conductivity in polyimide films by ion beam bombardment in the keloelectronvolt to megaelectronvolt energy range. The electrical properties of implanted polyimide were determined by four-point probe measurement. Depending on ion energy, doses, and ion type, the surface resistivity of the film is reduced by several orders of magnitude. Ion bombarded layers were characterized by Time-of-Flight Secondary Ion Mass Spectrometry (TOF-SIMS), XPS, and SEM.

  • PDF

EFFECTS OF NITROGEN AND CARBON ION IMPLANTATION INTO AUSTENITIC STAINLESS STEEL ON HYDROGEN ABSORPTION

  • Terashima, K.;Minegishi, T.;Matsusaka, K.
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.5
    • /
    • pp.494-497
    • /
    • 1996
  • The effect of implanted nitrogen and carbon ion into SUS 304 on the absorption of hydrogen by cathodic chaging were studied. Implantations of $N^+$, $C^+$ were performed with doses of $3\times10^{17}$ ions $\textrm{cm}^2$ and $5\times10^{17}N^+cm^2$, and $5\times10^{17}C^+cm^2$, at an energy of 90 keV. Nitrides and carbide were investigatedby X-ray diffraction, Auger electron spectroscopy (AES) and scanning electron microscope (SEM). Formation of hydrides during cathodic charging were depressed by a modified surface layer. It is concluded that the both nitrides and carbides act as the barrier of hydrogen migration and the catalyst of desorption of cathodically charged hydrogen.

  • PDF

BIOCOMPATIBISITY OF ION BEAM PROCESSED FILMS DEPOSITED ON SURGICAL TI-6AI-4V

  • Lee, I-S;Song and I-j Yu
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.S1
    • /
    • pp.16-22
    • /
    • 1997
  • ion beam processing of materials for medical application has gained increasing interest in the last decade and the implantation of nitrogen into TI-6AI-4V to improve corrosive-wear performance is currently used for processing of total hip and knee joints. Oxides and nitrides of Ti, Zr, Al, Cr were deposited on TI-6AI-4V substrates by DC magnetron sputtering dual ion beam sputtering and ion beam assisted deposition. The cytotoxicity of these films were investigated by MTT method and showed comparable to untreated TI-6AI-4V Plasm-sprayed hydroxyapatite(HAp) coatings showed excellent cytotoxicity regardless of heat treatment. intermediate layer coatings of nitrides and oxides increased the bond strength of HAp to substrate by intrdducing chemical bond at interface. Heat treatment of HAp coatings also improved the chemical bond at interfaces and increased the bond strength of untreated TI-6AI-4V to 16.4 kg/$\textrm{cm}^2$ but still lower than 33.1 kg./$\textrm{cm}^2$ of ir oxide as a imtermediate layer caoting.

  • PDF

A Study on the friction and Wear Characteristics of C-N Coated SCM415 Steel (C-N코팅 SCM415강의 마찰$\cdot$마모 특성에 관한 연구)

  • Lyu Sung-ki;Lu Long;Jin Tai-yu;Lian Zhe-Man;Cao Xing-Jin;Cho Sung-Min
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.1 s.69
    • /
    • pp.18-23
    • /
    • 2005
  • This study deals with the friction and wear characteristics of C-N coated SCM415 steel. The PSII(plasma source ion implantation) apparatus was built and a SCM415 test piece with steel substrate was treated with carbon nitrogen by this apparatus. The composition and structure of the surface layer were analyzed and compared with that of PVD(physical vapor decomposition) coated TiN layer. It was found that both of friction coefficient of C-N coating and TiN coating decreased with increasing load, however, C-N coating showed relatively lower faction coefficient than that of TiN coating. The micro-vickers hardness of C-N film is 3200 Hv, which is $32\~43\%$ higher than that of TiN film. The critical load of C-N film is 52N, which is $25\%$ higher than that of TiN film. The hardness of C-N film fabricated by Plasma ion implantation is $61\~70\%$ higher than that of base material, and faction coefficient is $14\~50\%$ lower than that of base material. It is also interesting to note that the friction was changed from adhesive wear mode to light oxidizing wear mode.

Recrystallization of Al Thin Film and Formation of AlN by Nitrogen Ion Implantation (질소이온 주입에 의한 Al의 재결정화 및 AlN의 형성에 관한 연구)

  • 조성진;최점수
    • Journal of the Korean Vacuum Society
    • /
    • v.1 no.2
    • /
    • pp.298-301
    • /
    • 1992
  • 진공증착된 Al 다결정 박막에 질소이온을 25keV-50keV, 1 $\times$ 1014-2 $\times$ 1017ions/cm2로 주입하여 박막의 결정구조와 nitride의 형성을 TEM으로 측정하였다. N+2이 온을 에너지 25keV, dose 1 $\times$ 1014ions/cm2로 주입하면 fcc 구조의 Al 결정이 관찰되며, 40keV 이상의 에너지로 2 $\times$ 1017ions/cm2이상 주입하면 AlN이 형성됨을 확인하였다.

  • PDF

Ion composition analysis of plasma sources for PSII (플라즈마 소스 이온주입용 플라즈마원의 이온 분석)

  • Kim, G.H.;Nikiforov, S.A.;Lee, H.S.;Rim, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2044-2046
    • /
    • 2000
  • A system to monitor the ion mass and charge-state as well as plasma potential value during plasma source ion implantation (PSII) has been developed. It was tested with 30-kV PI3D setup using alternatively hot cathode do (HC) and inductively coupled RF (ICP) discharge sources. The design and performance of the system will be described, and experimental results in nitrogen and argon plasmas produced by modular HC-ICP source will be discussed.

  • PDF

Hard TiN Coating by Magnetron-ICP P $I^3$D

  • Nikiforov, S.A.;Kim, G.H.;Rim, G.H.;Urm, K.W.;Lee, S.H.
    • Journal of the Korean institute of surface engineering
    • /
    • v.34 no.5
    • /
    • pp.414-420
    • /
    • 2001
  • A 30-kV plasma immersion ion implantation setup (P $I^3$) has been equipped with a self-developed 6'-magnetron to perform hard coatings with enhanced adhesion by P $I^3$D(P $I^3$ assisted deposition) process. Using ICP source with immersed Ti antenna and reactive magnetron sputtering of Ti target in $N_2$/Ar ambient gas mixture, the TiN films were prepared on Si substrates at different pulse bias and ion-to-atom arrival ratio ( $J_{i}$ $J_{Me}$ ). Prior to TiN film formation the nitrogen implantation was performed followed by deposition of Ti buffer layer under A $r^{+}$ irradiation. Films grown at $J_{i}$ $J_{Me}$ =0.003 and $V_{pulse}$=-20kV showed columnar grain morphology and (200) preferred orientation while those prepared at $J_{i}$ $J_{Me}$ =0.08 and $V_{pulse}$=-5 kV had dense and eqiaxed structure with (111) and (220) main peaks. X-ray diffraction patterns revealed some amount of $Ti_{x}$ $N_{y}$ in the films. The maximum microhardness of $H_{v}$ =35 GN/ $M^2$ was at the pulse bias of -5 kV. The P $I^3$D technique was applied to enhance wear properties of commercial tools of HSS (SKH51) and WC-Co alloy (P30). The specimens were 25-kV PII nitrogen implanted to the dose 4.10$^{17}$ c $m^{-2}$ and then coated with 4-$\mu\textrm{m}$ TiN film on $Ti_{x}$ $N_{y}$ buffer layer. Wear resistance was compared by measuring weight loss under sliding test (6-mm $Al_2$ $O_3$ counter ball, 500-gf applied load). After 30000 cycles at 500 rpm the untreated P30 specimen lost 3.10$^{-4}$ g, and HSS specimens lost 9.10$^{-4}$ g after 40000 cycles while quite zero losses were demonstrated by TiN coated specimens.s.

  • PDF

The Study on the Micro Structure Change and Corrosion Resistance Improvement of AI Alloy by Nitrogen Ion Implantation (질소이온주입에 의한 AI 합금의 조직변화 및 내식성 향상에 관한 연구)

  • 엄기원;윤주선;한전건;연윤모
    • Journal of the Korean Vacuum Society
    • /
    • v.4 no.2
    • /
    • pp.183-188
    • /
    • 1995
  • 고에너지(50-200KeV)로 가속된 이온을 모재표면에 물리적으로 투입하므로써 표면의 조성 및 조직을 변화시키는 공정인 이온주입기술을 이용하여 경량고강도소재로 각광받고 있는 AI2218 합금의 재식성 향상을 연구하였다. 질소이온주입은 DuoPIGatron 이온원을 사용하여 가속전압 100KeV, 조사량 $1{\times}10^{17}ions/\textrm{cm}^2$~$5{\times}10^{17}ions/\textrm{cm}^2$의 조건으로 행하였으며 AI합금의 열화를 방지하기 위하여 시편온도를 $60^{\circ}C$이하로 유지하였다. 질소이온 주입재의 재식성 평가를 위하여 3.5% NaCI 용액에서 양극분극시험 및 5% NaCI 용액에서 염수분무시험을 행하였다. Auger Electron Spectroscopy와 Transmission Electron Microscopy을 이용하여 표면의 질화물형성 여부를 조사하였으며, Scanning Electron Microscopy을 이용하여 부식된 표면을 관찰하였다. AI2218합금에 질소이온을 주입한 결과 표면에 미세한 AIN 석출물을 형성하였으며 이러한 질화물형성에 의해 공식(pitting)발생을 억제하고 부식전류밀도를 감소시켜 내식성이 향상되었다.

  • PDF