• Title/Summary/Keyword: Nitrite accumulation

Search Result 75, Processing Time 0.035 seconds

Nitrite Accumulation Characteristics and Quantitative Analyses of Nitrifying and Denitrifying Bacteria in a Sequencing Batch Reactor (연속회분반응기의 아질산 축적 특성과 질산화 및 탈질 미생물의 정량적 분포 연구)

  • Kim, Dong-Jin;Kwon, Hyun-Jin;Yoon, Jung-Yee;Cha, Gi-Cheol
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.3
    • /
    • pp.383-390
    • /
    • 2008
  • Recently, the interests on economical nitrogen removal from wastewater are growing. As a method of the novel nitrogen removal technology, nitrogen removal via nitrite pathway by selective inhibition of free ammonia and free nitrous acid on nitrite oxidizing bacteria have been intensively studied. The inhibition effects of free ammonia and free nitrous acid are low when domestic wastewater is used, however, because of its relatively lower nitrogen concentration than the wastewater from industry and landfill, etc. In this study, a sequencing batch reactor (SBR) is proposed for nitrogen removal to investigate the effect of the low nitrogen concentration on nitrite accumulation. Nitrification efficiency reached almost 100% during the aerobic cycle and the maximum specific nitrification rate ($V_{max,nit}$) reached $17.8mg\;NH_4{^+}-N/g\;MLVSS{\bullet}h$. During the anoxic cycle, average denitrification efficiency reached 87% and the maximum specific denitrification rate ($V_{max,den}$) reached $9.8mg\;NO_3{^-}-N/g\;MLVSS{\bullet}h$. From the analysis the main reason of nitrite accumulation in the SBR was free nitrous acid rather than free ammonia. Nitrite accumulation increased with the decrease of organic content in the wastewater and the mechanism is not well understood yet. From the result of fluorescent in situ hybridization, the distribution of nitrite oxidizing bacteria was in equilibrium with ammonium oxidizing bacteria when nitrite accumulation did not occur.

Nitrite Accumulation of Anaerobic Treatment Effluent of Slurry-type Piggery Waste (슬러리상 돈사폐수의 혐기성 처리수의 아질산성 질소 축적)

  • Hwang, In-Su;Min, Kyung-Sok;Yun, Zuwhan
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.4
    • /
    • pp.711-719
    • /
    • 2006
  • The effluent from anaerobic digestion process of slurry-type piggery waste has a characteristic of very low C/N ratio. Because of high nitrogen content, it is necessary to evaluate nitrogen removal alternative rather than conventional nitrification-denitrification scheme. In this study, two parallel treatment schemes of SBR-like partial nitritation reactor coupled with anaerobic ammonium oxidation (ANAMMOX) reactor, and a nitritation reactor followed by nitrite denitrification process were evaluated with a slurry-type piggery waste. The feed to reactors adjusted with various $NH_4-N$ and organics concentration. The nitrite accumulation was successfully accomplished at the loading rate of about $1.0kgNH_4-N/m^3-day$. The $NO_2-N/NH_4-N$ ratio 1~2.6 in nitritated effluent that operated at HRT of 1 day indicated that SBR-like partial nitritation was applicable to ANAMMOX operation. Meanwhile, the nitrite accumulation of 87% was achieved at SBR operated with HRT of 3 days and $0.4mgO_2/L$ for denitritation. Experimental results further suggested that HRT (SRT) and free ammonia(FA) rather than DO are an effective control parameter for nitrite accumulation in piggery waste.

Parameters Affecting Nitrite Accumulation in Submerged Biofilm Reactor (생물막 반응기에서 아질산성 질소의 축척에 미치는 영향인자)

  • Hwang, Byung-Ho;Hwang, Kyung-Yub;Choi, Eui-So
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.10
    • /
    • pp.1789-1797
    • /
    • 2000
  • The objective of this study was to assess parameters affecting nitrite accumulation, which offers advantages in terms of less aeration energy and carbon consumption for denitrification. The influence of the alkalinity to $NH_4{^+}-N$ concentration ratio, pH, FA(free ammonia) concentration and temperature on nitrite accumulation was investigated. The experiment was performed with supernatant from dewatering process of anaerobic digested sludge using a submerged biofilm reactor. The influent contains high strength of ammonium nitrogen and the alkalinity was insufficient for complete nitrification. An increased nitrite accumulation was observed with increase in alkalinity to $NH_4{^+}-N$ concentration ratio. The increase in alkalinity to $NH_4{^+}-N$ concentration ratio has been a maior reason for the high pH value and FA concentration in the reactor. It can be considered that selective inhibition of Nitrobacter can be causes of nitrite accumulation. The nitrite accumulation increased with increment of temperature at fixed alkalinity to $NH_4{^+}-N$ concentration ratio.

  • PDF

Influence of Ammonia and Dissolved Oxygen Concentrations on Nitrite Accumulation in a MBR (MBR 반응조에서 아질산염 축적에 미치는 암모니아와 용존산소 농도의 영향 연구)

  • Choi, In-Su;Wiesmann, Udo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.8
    • /
    • pp.922-929
    • /
    • 2007
  • The complete oxidation of ammonia to nitrate is a distinctive two-step process divided into the oxidation of ammonia to nitrite(nitritation) by Nitrosomonas and the oxidation of nitrite to nitrate(nitratation) by Nitrobacter. The nitrogen removal via nitrite accumulation offers several advantages such as saving costs for aeration, saving carbon source and finally reduction of sludge discharge. In this work a suspended bioreactor coupled with membrane filtration(MBR) was used to find the process conditions of nitrite build-up. The MBR enables to reach sufficient nitrifying bacteria in the bioreactor, although the autotrophic bacteria can be easily washed out due to their lower growth rate. The dissolved oxygen concentration $c'_{O2}$ and ammonia concentration $c_{NH3}$ in the reactor were varied and investigated as parameters for nitrite accumulation. As a result the higher ammonia concentration in the reactor is very effective for starting nitrite build-up and the effect was strengthened in combination with lower dissolved oxygen concentration. With lower $c'_{O2}<0.3$ $mgL^{-1}$ $O_2$ and high $c_{NH3}=6.3\sim14.9$ $mgL^{-1}$ $NH_3N$ the 74% of the nitrite accumulation was achieved. Specially, it was found that the nitrite accumulation could occur not only in biofilm reactor as many references showed but also in the membrane bioreactor carried out in this study.

Experimental Intervention to Reverse Inhibition of Nitric Oxide Production by Cyclosporin A in Rat Aortic Smooth Muscle Cells (혈관평활근세포에서 Cyclosporin A에 의한 Nitric Oxide 생성억제를 길항하는 실험적 중재법)

  • Kim, In-Kyeom
    • The Korean Journal of Pharmacology
    • /
    • v.32 no.2
    • /
    • pp.211-219
    • /
    • 1996
  • The inhibitory effect of cyclosporin A (CsA) on nitric oxide production is not related to the immunosuppressive action of the drug, but to the renal toxicity and arterial hyper-tension. In this study the experimental interventions to reverse the inhibition of nitric oxide production by cyclosporin A in rat aortic smooth muscle cells were examined. CsA inhibited the accumulation of nitrite, the stable end product of nitric oxide, in culture media in a concentration $(0.1{\sim}100{\mu}g/ml)-dependent$ manner. The inhibitory effect of CsA on nitrite accumulation were not antagonized by arginine (10 mM), a substrate of nitric oxide synthase, nor by calcium ionophore A23187 $(7{\mu}M)$. Forskolin, an activator of adenylate cyclase, which enhanced iNOS induction at transcriptional level, completely reversed the inhibitory action of CsA on nitrite accumulation. However, PMA (2 nM) and PDB (50 nM), PKC activators, increased the inhibitory action of CsA on nitrite accumulalion. From these results, it is suggested that cyclic AMP-elevating agents may be candidates of therapeutic agents in prevention and treatment of renal toxicity and arterial hypertension induced by CsA. Among conventional antihypertensive drugs, calcium channel blockers and ${\alpha}-blockers$ are preferred to ${\beta}-blockers$.

  • PDF

Effect of Temperature and FA Concentration on the Conversion of Ammonium to Nitrite (온도와 FA 농도가 암모늄 이온의 아질산 전환에 미치는 영향)

  • Kim, Jung Hoon;Song, Young Chae;Park, Hung Suck
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4B
    • /
    • pp.427-432
    • /
    • 2006
  • The effects of free ammonia (FA) concentration and temperature on nitrite accumulation were studied. To estimate the most effective ammonium oxidation and nitrite build-up condition, nitrification tests were conducted in batch conditions at various FA concentrations, and at different ammonium concentration and temperature. The activation energies of ammonium oxidizer were 81.7 KJ/mol below $20^{\circ}C$, and 32.5 KJ/mol over $20^{\circ}C$, while that of nitrite oxidizer was 35.5 KJ/mol irrespective of temperature variations. The results of nitrification tests conducted at different FA concentrations and temperatures showed that temperature strongly affects nitrite accumulation, while effects due to FA concentrations were found negligible.

Influence of Operating Parameters on Nitrite Accumulation in a Biofilm Reactor and Supplement of External Carbon Source for Denitrification by Sewage Sludge Solubilization (생물막 반응조에서 아질산염 축적에 미치는 운전인자 영향과 하수슬러지 가용화에 의한 탈질반응의 외부탄소원 공급에 관한 연구)

  • Ahn, Hye Min;Lee, Dae Sung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.1
    • /
    • pp.57-63
    • /
    • 2013
  • A combined process consisted of a biofilm reactor and a continuously stirred-tank reactor (CSTR) was investigated for highly loaded ammonium wastewater treatment via nitrite accumulation. To enhance ammonium oxidizing bacteria over nitrite oxidizing bacteria on the surface of carriers, the biofilm reactor was operated at temperature of $35^{\circ}C$ for more than three months but the influent ammonium (500 mg-N/L) was partially oxidized to nitrite (240 mg-N/L). As pH was increased from 7.5 to 8.0, nitrite accumulation was fully achieved due to the inhibition of nitrite oxidizing bacteria under high free ammonia concentration. The biofilm reactor performance was severely deteriorated at the hydraulic retention time of 12 hr, at which incomplete nitrification of ammonia was observed. Various solubilization methods were applied to sewage sludge for enhancing its biodegradability and the combined method, alkaline followed by ultrasonic, gave the highest solubilization efficiency (58%); the solubilized solution was used as the external carbon source for denitrification reaction in CSTR. FISH analysis showed that the dominant microorganisms on the carriers were ammonium oxidizing bacteria such as Nitrosomonas spp. and Nitrospirar spp. but low amounts of nitrite oxidizing bacteria as Nitrobacter spp. was also detected.

BIOCHEMICAL MODEL AND MECHANISM FOR ACINETOBACTER NITRITE INHIBITION

  • Lee, Chan-Won;Weon, Seung-Yeon
    • Environmental Engineering Research
    • /
    • v.10 no.1
    • /
    • pp.22-30
    • /
    • 2005
  • Nitrite accumulation is not unusual in batch processes such as sequencing batch reactor (SBR) with high-strength of ammonium or nitrate wastewaters. A possible mechanism of nitrite inhibition on Acinetobacter was depicted in a biochemical model, which the protonated species, nitrous acid form of nitrite, affects proton relating transport at the proton-pumping site crossing the cell membrane under unlimited carbon and phosphorus conditions. This effect exerts inhibition of phosphorylation under aerobic condition and yields low APT/ADP ratio, consequently decrease poly-P synthesis and phosphorus uptake from outside the cell in the model.

Nitrogen Removal from ADEPT Effluent of Piggery Wastewater using Nitritation/Denitiritation System (ADEPT공정을 거친 돈사폐수의 아질산화-아탈질 공정을 이용한 질소제거)

  • Lee, Hwa-Sun;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.134-139
    • /
    • 2006
  • Partial nitirification and denitrification process has been reported to be technically feasible and economically favorable, especially for wastewater treatment with high ammonium concentration or low Carbon/Nitrogen ratio. This research was performed to survey nitrite accumulation by nitritation in treating ADEPT effluent of piggery wastewater, which contains highly concentrated ammonia. To estimate the possibility of nitrite accumulation, DO concentration and SRT were investigated as key operational parameters. This result proved that nitritation to nitrite was steadily obtained under short sludge retention time. Oxygen limitation was proved to be just a subsidiary parameter. Energy efficiency of nitritation-denitritation process was higher than complete nitrification-denitrification because external carbon requirement for denitritation could be saved. Though the influent contained significant nonbiodegradable organic substrate, total nitrogen removal efficiency was more than 51% in nitritation-denitritation system.

Community structure analysis of nitrifying biofilms by 16S rRNA targeted probe and fluorescence in situ hybridization (FISH)

  • Han, Dong-U;Kim, Dong-Jin
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.282-285
    • /
    • 2001
  • The microbial community structure and in situ spatial distribution of ammonia oxidizing and nitrite oxidizing bacteria in nitrifying biofilm of an upflow biological aerated filter system were investigated. The reactor had been continuously operated under high free ammonia concentration and low DO concentration for nitrite accumulation more than 2 years before the experiment. Fluorescence in situ hybridization

  • PDF